<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://wiki.nanofab.ucsb.edu/w/index.php?action=history&amp;feed=atom&amp;title=Photolithography_-_Improving_Adhesion_Photoresist_Adhesion</id>
	<title>Photolithography - Improving Adhesion Photoresist Adhesion - Revision history</title>
	<link rel="self" type="application/atom+xml" href="https://wiki.nanofab.ucsb.edu/w/index.php?action=history&amp;feed=atom&amp;title=Photolithography_-_Improving_Adhesion_Photoresist_Adhesion"/>
	<link rel="alternate" type="text/html" href="https://wiki.nanofab.ucsb.edu/w/index.php?title=Photolithography_-_Improving_Adhesion_Photoresist_Adhesion&amp;action=history"/>
	<updated>2026-10-19T08:39:17Z</updated>
	<subtitle>Revision history for this page on the wiki</subtitle>
	<generator>MediaWiki 1.43.9</generator>
	<entry>
		<id>https://wiki.nanofab.ucsb.edu/w/index.php?title=Photolithography_-_Improving_Adhesion_Photoresist_Adhesion&amp;diff=163940&amp;oldid=prev</id>
		<title>John d: Updated underlayer process and tips</title>
		<link rel="alternate" type="text/html" href="https://wiki.nanofab.ucsb.edu/w/index.php?title=Photolithography_-_Improving_Adhesion_Photoresist_Adhesion&amp;diff=163940&amp;oldid=prev"/>
		<updated>2026-09-10T19:33:38Z</updated>

		<summary type="html">&lt;p&gt;Updated underlayer process and tips&lt;/p&gt;
&lt;table style=&quot;background-color: #fff; color: #202122;&quot; data-mw=&quot;interface&quot;&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;tr class=&quot;diff-title&quot; lang=&quot;en&quot;&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;Revision as of 19:33, 10 September 2026&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 1:&lt;/td&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 1:&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;a class=&quot;mw-diff-movedpara-left&quot; title=&quot;Paragraph was moved. Click to jump to new location.&quot; href=&quot;#movedpara_4_3_rhs&quot;&gt;&amp;#x26AB;&lt;/a&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;a name=&quot;movedpara_0_0_lhs&quot;&gt;&lt;/a&gt;Don&#039;t forget that, for [[Lithography Recipes#Lift-Off Recipes|lift-off processes]], the Imaging (top) Photoresist will lift-off as well if you undercut it too much during develop!&lt;/div&gt;&lt;/td&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-empty diff-side-added&quot;&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br /&gt;&lt;/td&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-empty diff-side-added&quot;&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;==Underlayers for improving PR adhesion==&lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;==Underlayers for improving PR adhesion==&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;High-temperature (&amp;gt;150°C) underlayers, such as LOL1000/2000, BARC layers tend to improve adhesion of the imaging resist.&lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;High-temperature (&amp;gt;150°C) underlayers, such as LOL1000/2000, BARC layers tend to improve adhesion of the imaging resist.&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 7:&lt;/td&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 5:&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*Apply high-temp underlayer, eg. LOL1000/2000, PMGI, DSK101 (DUV), DSK42P (DUV)&lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*Apply high-temp underlayer, eg. LOL1000/2000, PMGI, DSK101 (DUV), DSK42P (DUV)&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;**Beware of underlayers that have a develop-rate - undercutting the imaging PR fully can also cause delamination)&lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;**Beware of underlayers that have a develop-rate - undercutting the imaging PR fully can also cause delamination)&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-empty diff-side-deleted&quot;&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*Bake at recommended temperature for the underlayer, typically &amp;gt;&amp;gt; 150°C.&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*Apply your Imaging photoresist as normal&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;.&lt;/del&gt;&lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*Apply&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt; &amp;amp; bake&lt;/ins&gt; your Imaging photoresist as normal&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt; for that resist, &lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-empty diff-side-deleted&quot;&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;**Bake temp should be lower than the underlayer bake temp.&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-empty diff-side-deleted&quot;&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*If your underlayer dissolves during the same develop step as the imaging resist, you will need to increase your develop time to go through both layers.  &lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-empty diff-side-deleted&quot;&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;a class=&quot;mw-diff-movedpara-right&quot; title=&quot;Paragraph was moved. Click to jump to old location.&quot; href=&quot;#movedpara_0_0_lhs&quot;&gt;&amp;#x26AB;&lt;/a&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;a name=&quot;movedpara_4_3_rhs&quot;&gt;&lt;/a&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;**&lt;/ins&gt;Don&#039;t forget that, for [[Lithography Recipes#Lift-Off Recipes|lift-off processes]], the Imaging (top) Photoresist will lift-off as well if you undercut it too much during develop!&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br /&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br /&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;==HMDS Process for PR Improving Adhesion==&lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;==HMDS Process for PR Improving Adhesion==&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/table&gt;</summary>
		<author><name>John d</name></author>
	</entry>
	<entry>
		<id>https://wiki.nanofab.ucsb.edu/w/index.php?title=Photolithography_-_Improving_Adhesion_Photoresist_Adhesion&amp;diff=161847&amp;oldid=prev</id>
		<title>John d: /* HMDS Process for PR Improving Adhesion */ dehydration/O2 pasma midifcation</title>
		<link rel="alternate" type="text/html" href="https://wiki.nanofab.ucsb.edu/w/index.php?title=Photolithography_-_Improving_Adhesion_Photoresist_Adhesion&amp;diff=161847&amp;oldid=prev"/>
		<updated>2024-02-10T19:41:36Z</updated>

		<summary type="html">&lt;p&gt;&lt;span class=&quot;autocomment&quot;&gt;HMDS Process for PR Improving Adhesion: &lt;/span&gt; dehydration/O2 pasma midifcation&lt;/p&gt;
&lt;table style=&quot;background-color: #fff; color: #202122;&quot; data-mw=&quot;interface&quot;&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;tr class=&quot;diff-title&quot; lang=&quot;en&quot;&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;Revision as of 19:41, 10 February 2024&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 12:&lt;/td&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 12:&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;This process tends to improve adhesion between the substrate and subsequent photoresist layers.  Use this procedure if you are finding poor adhesion (resist delaminating during develop etc.), or for chemicals (like BHF) that attack the PR adhesion interface strongly.&lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;This process tends to improve adhesion between the substrate and subsequent photoresist layers.  Use this procedure if you are finding poor adhesion (resist delaminating during develop etc.), or for chemicals (like BHF) that attack the PR adhesion interface strongly.&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br /&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br /&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-empty diff-side-deleted&quot;&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*150°C bake ~2min (Dehydration step)&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*O2 plasma ([[Ashers (Technics PEII)|PEii Technics]]), 10sec&lt;/div&gt;&lt;/td&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-empty diff-side-added&quot;&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-empty diff-side-deleted&quot;&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;**Optionally could instead do Dehydration of: O2 plasma ([[Ashers (Technics PEII)|PEii Technics]]), 10sec; however this could create more surface SiO2 on silicon. &lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;**This takes the place of the dehydration bake.&lt;/div&gt;&lt;/td&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-empty diff-side-added&quot;&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*&#039;&#039;No bake&#039;&#039;&lt;/div&gt;&lt;/td&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-empty diff-side-added&quot;&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*HMDS application &amp;amp; soak 40s&lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*HMDS application &amp;amp; soak 40s&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;**Do this with sample loaded on the PR spinner.&lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;**Do this with sample loaded on the PR spinner.&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/table&gt;</summary>
		<author><name>John d</name></author>
	</entry>
	<entry>
		<id>https://wiki.nanofab.ucsb.edu/w/index.php?title=Photolithography_-_Improving_Adhesion_Photoresist_Adhesion&amp;diff=159457&amp;oldid=prev</id>
		<title>John d: mentioned lift-off delam</title>
		<link rel="alternate" type="text/html" href="https://wiki.nanofab.ucsb.edu/w/index.php?title=Photolithography_-_Improving_Adhesion_Photoresist_Adhesion&amp;diff=159457&amp;oldid=prev"/>
		<updated>2021-11-24T18:27:15Z</updated>

		<summary type="html">&lt;p&gt;mentioned lift-off delam&lt;/p&gt;
&lt;table style=&quot;background-color: #fff; color: #202122;&quot; data-mw=&quot;interface&quot;&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;tr class=&quot;diff-title&quot; lang=&quot;en&quot;&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;Revision as of 18:27, 24 November 2021&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 1:&lt;/td&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 1:&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-empty diff-side-deleted&quot;&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Don&#039;t forget that, for [[Lithography Recipes#Lift-Off Recipes|lift-off processes]], the Imaging (top) Photoresist will lift-off as well if you undercut it too much during develop!&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;a class=&quot;mw-diff-movedpara-left&quot; title=&quot;Paragraph was moved. Click to jump to new location.&quot; href=&quot;#movedpara_2_1_rhs&quot;&gt;&amp;#x26AB;&lt;/a&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;a name=&quot;movedpara_1_0_lhs&quot;&gt;&lt;/a&gt;==&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt; &lt;/del&gt;Underlayers for improving PR adhesion&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt; &lt;/del&gt;==&lt;/div&gt;&lt;/td&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-empty diff-side-added&quot;&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-empty diff-side-deleted&quot;&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br /&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-empty diff-side-deleted&quot;&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;a class=&quot;mw-diff-movedpara-right&quot; title=&quot;Paragraph was moved. Click to jump to old location.&quot; href=&quot;#movedpara_1_0_lhs&quot;&gt;&amp;#x26AB;&lt;/a&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;a name=&quot;movedpara_2_1_rhs&quot;&gt;&lt;/a&gt;==Underlayers for improving PR adhesion==&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;High-temperature (&amp;gt;150°C) underlayers, such as LOL1000/2000, BARC layers tend to improve adhesion of the imaging resist.&lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;High-temperature (&amp;gt;150°C) underlayers, such as LOL1000/2000, BARC layers tend to improve adhesion of the imaging resist.&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br /&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br /&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt; &lt;/del&gt;Substrate prep: O2 plasma ([[Ashers (Technics PEII)|PEii Technics]]), 10sec&lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*Substrate prep: O2 plasma ([[Ashers (Technics PEII)|PEii Technics]]), 10sec&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt; &lt;/del&gt;Apply high-temp underlayer, eg. LOL1000/2000, PMGI, DSK101 (DUV), DSK42P (DUV)&lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*Apply high-temp underlayer, eg. LOL1000/2000, PMGI, DSK101 (DUV), DSK42P (DUV)&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;**&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt; &lt;/del&gt;Beware of underlayers that have a develop-rate - undercutting the imaging PR fully can also cause delamination)&lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;**Beware of underlayers that have a develop-rate - undercutting the imaging PR fully can also cause delamination)&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt; &lt;/del&gt;Apply your Imaging photoresist as normal.&lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*Apply your Imaging photoresist as normal.&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br /&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br /&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;==&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt; &lt;/del&gt;HMDS Process for PR Improving Adhesion&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt; &lt;/del&gt;==&lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;==HMDS Process for PR Improving Adhesion==&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;This process tends to improve adhesion between the substrate and subsequent photoresist layers.  Use this procedure if you are finding poor adhesion (resist delaminating during develop etc.), or for chemicals (like BHF) that attack the PR adhesion interface strongly.&lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;This process tends to improve adhesion between the substrate and subsequent photoresist layers.  Use this procedure if you are finding poor adhesion (resist delaminating during develop etc.), or for chemicals (like BHF) that attack the PR adhesion interface strongly.&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br /&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br /&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt; &lt;/del&gt;O2 plasma ([[Ashers (Technics PEII)|PEii Technics]]), 10sec&lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*O2 plasma ([[Ashers (Technics PEII)|PEii Technics]]), 10sec&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;**&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt; &lt;/del&gt;This takes the place of the dehydration bake.&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt; &lt;/del&gt;&lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;**This takes the place of the dehydration bake.&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt; &lt;/del&gt;&#039;&#039;No bake&#039;&#039;&lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*&#039;&#039;No bake&#039;&#039;&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt; &lt;/del&gt;HMDS application &amp;amp; soak 40s&lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*HMDS application &amp;amp; soak 40s&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;**&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt; &lt;/del&gt;Do this with sample loaded on the PR spinner.&lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;**Do this with sample loaded on the PR spinner.&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt; &lt;/del&gt;Spin-dry - any spin speed, ~15-30sec&lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*Spin-dry - any spin speed, ~15-30sec&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt; &lt;/del&gt;HMDS bake at 100-110°C for 90s.  &lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*HMDS bake at 100-110°C for 90s.  &lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt; &lt;/del&gt;Then your normal PR process on top.&lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*Then your normal PR process on top.&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/table&gt;</summary>
		<author><name>John d</name></author>
	</entry>
	<entry>
		<id>https://wiki.nanofab.ucsb.edu/w/index.php?title=Photolithography_-_Improving_Adhesion_Photoresist_Adhesion&amp;diff=159452&amp;oldid=prev</id>
		<title>John d: John d moved page Photolithography - HMDS Process for Improving Adhesion to Photolithography - Improving Adhesion Photoresist Adhesion without leaving a redirect: more generalized page title</title>
		<link rel="alternate" type="text/html" href="https://wiki.nanofab.ucsb.edu/w/index.php?title=Photolithography_-_Improving_Adhesion_Photoresist_Adhesion&amp;diff=159452&amp;oldid=prev"/>
		<updated>2021-11-24T18:12:13Z</updated>

		<summary type="html">&lt;p&gt;John d moved page &lt;a href=&quot;/w/index.php?title=Photolithography_-_HMDS_Process_for_Improving_Adhesion&amp;amp;action=edit&amp;amp;redlink=1&quot; class=&quot;new&quot; title=&quot;Photolithography - HMDS Process for Improving Adhesion (page does not exist)&quot;&gt;Photolithography - HMDS Process for Improving Adhesion&lt;/a&gt; to &lt;a href=&quot;/wiki/Photolithography_-_Improving_Adhesion_Photoresist_Adhesion&quot; title=&quot;Photolithography - Improving Adhesion Photoresist Adhesion&quot;&gt;Photolithography - Improving Adhesion Photoresist Adhesion&lt;/a&gt; without leaving a redirect: more generalized page title&lt;/p&gt;
&lt;table style=&quot;background-color: #fff; color: #202122;&quot; data-mw=&quot;interface&quot;&gt;
				&lt;tr class=&quot;diff-title&quot; lang=&quot;en&quot;&gt;
				&lt;td colspan=&quot;1&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan=&quot;1&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;Revision as of 18:12, 24 November 2021&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-notice&quot; lang=&quot;en&quot;&gt;&lt;div class=&quot;mw-diff-empty&quot;&gt;(No difference)&lt;/div&gt;
&lt;/td&gt;&lt;/tr&gt;&lt;/table&gt;</summary>
		<author><name>John d</name></author>
	</entry>
	<entry>
		<id>https://wiki.nanofab.ucsb.edu/w/index.php?title=Photolithography_-_Improving_Adhesion_Photoresist_Adhesion&amp;diff=159451&amp;oldid=prev</id>
		<title>John d: added Underlayers for PR adhesion</title>
		<link rel="alternate" type="text/html" href="https://wiki.nanofab.ucsb.edu/w/index.php?title=Photolithography_-_Improving_Adhesion_Photoresist_Adhesion&amp;diff=159451&amp;oldid=prev"/>
		<updated>2021-11-24T18:11:24Z</updated>

		<summary type="html">&lt;p&gt;added Underlayers for PR adhesion&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;== Underlayers for improving PR adhesion ==&lt;br /&gt;
High-temperature (&amp;gt;150°C) underlayers, such as LOL1000/2000, BARC layers tend to improve adhesion of the imaging resist.&lt;br /&gt;
&lt;br /&gt;
* Substrate prep: O2 plasma ([[Ashers (Technics PEII)|PEii Technics]]), 10sec&lt;br /&gt;
* Apply high-temp underlayer, eg. LOL1000/2000, PMGI, DSK101 (DUV), DSK42P (DUV)&lt;br /&gt;
** Beware of underlayers that have a develop-rate - undercutting the imaging PR fully can also cause delamination)&lt;br /&gt;
* Apply your Imaging photoresist as normal.&lt;br /&gt;
&lt;br /&gt;
== HMDS Process for PR Improving Adhesion ==&lt;br /&gt;
This process tends to improve adhesion between the substrate and subsequent photoresist layers.  Use this procedure if you are finding poor adhesion (resist delaminating during develop etc.), or for chemicals (like BHF) that attack the PR adhesion interface strongly.&lt;br /&gt;
&lt;br /&gt;
* O2 plasma ([[Ashers (Technics PEII)|PEii Technics]]), 10sec&lt;br /&gt;
** This takes the place of the dehydration bake. &lt;br /&gt;
* &amp;#039;&amp;#039;No bake&amp;#039;&amp;#039;&lt;br /&gt;
* HMDS application &amp;amp; soak 40s&lt;br /&gt;
** Do this with sample loaded on the PR spinner.&lt;br /&gt;
* Spin-dry - any spin speed, ~15-30sec&lt;br /&gt;
* HMDS bake at 100-110°C for 90s.  &lt;br /&gt;
* Then your normal PR process on top.&lt;/div&gt;</summary>