<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://wiki.nanofab.ucsb.edu/w/index.php?action=history&amp;feed=atom&amp;title=Template%3ARecipe</id>
	<title>Template:Recipe - Revision history</title>
	<link rel="self" type="application/atom+xml" href="https://wiki.nanofab.ucsb.edu/w/index.php?action=history&amp;feed=atom&amp;title=Template%3ARecipe"/>
	<link rel="alternate" type="text/html" href="https://wiki.nanofab.ucsb.edu/w/index.php?title=Template:Recipe&amp;action=history"/>
	<updated>2026-08-02T15:30:20Z</updated>
	<subtitle>Revision history for this page on the wiki</subtitle>
	<generator>MediaWiki 1.43.9</generator>
	<entry>
		<id>https://wiki.nanofab.ucsb.edu/w/index.php?title=Template:Recipe&amp;diff=154332&amp;oldid=prev</id>
		<title>John d at 21:56, 3 August 2017</title>
		<link rel="alternate" type="text/html" href="https://wiki.nanofab.ucsb.edu/w/index.php?title=Template:Recipe&amp;diff=154332&amp;oldid=prev"/>
		<updated>2017-08-03T21:56:24Z</updated>

		<summary type="html">&lt;p&gt;&lt;/p&gt;
&lt;table style=&quot;background-color: #fff; color: #202122;&quot; data-mw=&quot;interface&quot;&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;tr class=&quot;diff-title&quot; lang=&quot;en&quot;&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;Revision as of 21:56, 3 August 2017&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 3:&lt;/td&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 3:&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;--&amp;gt;&lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;--&amp;gt;&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&amp;lt;noinclude&amp;gt;&#039;&#039;The recipe shown here is just a placeholder - please replace this info with your own. This text won&#039;t show up in the final page.&#039;&#039;&amp;lt;/noinclude&amp;gt;&lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&amp;lt;noinclude&amp;gt;&#039;&#039;The recipe shown here is just a placeholder - please replace this info with your own. This text won&#039;t show up in the final page.&#039;&#039;&amp;lt;/noinclude&amp;gt;&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br /&gt;&lt;/td&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-empty diff-side-added&quot;&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br /&gt;&lt;/td&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-empty diff-side-added&quot;&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&amp;lt;includeonly&amp;gt;[[category:Recipes]]&amp;lt;/includeonly&amp;gt;&lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&amp;lt;includeonly&amp;gt;[[category:Recipes]]&amp;lt;/includeonly&amp;gt;&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;==Recipe==&lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;==Recipe==&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/table&gt;</summary>
		<author><name>John d</name></author>
	</entry>
	<entry>
		<id>https://wiki.nanofab.ucsb.edu/w/index.php?title=Template:Recipe&amp;diff=154331&amp;oldid=prev</id>
		<title>John d at 21:56, 3 August 2017</title>
		<link rel="alternate" type="text/html" href="https://wiki.nanofab.ucsb.edu/w/index.php?title=Template:Recipe&amp;diff=154331&amp;oldid=prev"/>
		<updated>2017-08-03T21:56:08Z</updated>

		<summary type="html">&lt;p&gt;&lt;/p&gt;
&lt;table style=&quot;background-color: #fff; color: #202122;&quot; data-mw=&quot;interface&quot;&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;tr class=&quot;diff-title&quot; lang=&quot;en&quot;&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;Revision as of 21:56, 3 August 2017&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 3:&lt;/td&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 3:&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;--&amp;gt;&lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;--&amp;gt;&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&amp;lt;noinclude&amp;gt;&#039;&#039;The recipe shown here is just a placeholder - please replace this info with your own. This text won&#039;t show up in the final page.&#039;&#039;&amp;lt;/noinclude&amp;gt;&lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&amp;lt;noinclude&amp;gt;&#039;&#039;The recipe shown here is just a placeholder - please replace this info with your own. This text won&#039;t show up in the final page.&#039;&#039;&amp;lt;/noinclude&amp;gt;&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-empty diff-side-deleted&quot;&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br /&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;a class=&quot;mw-diff-movedpara-left&quot; title=&quot;Paragraph was moved. Click to jump to new location.&quot; href=&quot;#movedpara_4_0_rhs&quot;&gt;&amp;#x26AB;&lt;/a&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;a name=&quot;movedpara_2_0_lhs&quot;&gt;&lt;/a&gt;==Recipe==&lt;/div&gt;&lt;/td&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-empty diff-side-added&quot;&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br /&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br /&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&amp;lt;includeonly&amp;gt;[[category:Recipes]]&amp;lt;/includeonly&amp;gt;&lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&amp;lt;includeonly&amp;gt;[[category:Recipes]]&amp;lt;/includeonly&amp;gt;&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-empty diff-side-deleted&quot;&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;a class=&quot;mw-diff-movedpara-right&quot; title=&quot;Paragraph was moved. Click to jump to old location.&quot; href=&quot;#movedpara_2_0_lhs&quot;&gt;&amp;#x26AB;&lt;/a&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;a name=&quot;movedpara_4_0_rhs&quot;&gt;&lt;/a&gt;==Recipe==&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;;Recipe Name&lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;;Recipe Name&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;: SiOVert_MadeUp&lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;: SiOVert_MadeUp&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/table&gt;</summary>
		<author><name>John d</name></author>
	</entry>
	<entry>
		<id>https://wiki.nanofab.ucsb.edu/w/index.php?title=Template:Recipe&amp;diff=154330&amp;oldid=prev</id>
		<title>John d: format noinclude text</title>
		<link rel="alternate" type="text/html" href="https://wiki.nanofab.ucsb.edu/w/index.php?title=Template:Recipe&amp;diff=154330&amp;oldid=prev"/>
		<updated>2017-08-03T21:54:26Z</updated>

		<summary type="html">&lt;p&gt;format noinclude text&lt;/p&gt;
&lt;table style=&quot;background-color: #fff; color: #202122;&quot; data-mw=&quot;interface&quot;&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;tr class=&quot;diff-title&quot; lang=&quot;en&quot;&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;Revision as of 21:54, 3 August 2017&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 2:&lt;/td&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 2:&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Use the Definition List syntax, where ; denotes a title and : denotes a new line for the list under that item.&lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Use the Definition List syntax, where ; denotes a title and : denotes a new line for the list under that item.&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;--&amp;gt;&lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;--&amp;gt;&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&amp;lt;noinclude&amp;gt;&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;===&lt;/del&gt;The recipe shown here is just a placeholder - please replace this info with your own. This text won&#039;t show up in the final page.&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;===&lt;/del&gt;&amp;lt;/noinclude&amp;gt;&lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&amp;lt;noinclude&amp;gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;&#039;&#039;&lt;/ins&gt;The recipe shown here is just a placeholder - please replace this info with your own. This text won&#039;t show up in the final page.&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;&#039;&#039;&lt;/ins&gt;&amp;lt;/noinclude&amp;gt;&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;==Recipe==&lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;==Recipe==&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br /&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br /&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/table&gt;</summary>
		<author><name>John d</name></author>
	</entry>
	<entry>
		<id>https://wiki.nanofab.ucsb.edu/w/index.php?title=Template:Recipe&amp;diff=154329&amp;oldid=prev</id>
		<title>John d: format noinclide text</title>
		<link rel="alternate" type="text/html" href="https://wiki.nanofab.ucsb.edu/w/index.php?title=Template:Recipe&amp;diff=154329&amp;oldid=prev"/>
		<updated>2017-08-03T21:54:00Z</updated>

		<summary type="html">&lt;p&gt;format noinclide text&lt;/p&gt;
&lt;table style=&quot;background-color: #fff; color: #202122;&quot; data-mw=&quot;interface&quot;&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;tr class=&quot;diff-title&quot; lang=&quot;en&quot;&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;Revision as of 21:54, 3 August 2017&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 2:&lt;/td&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 2:&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Use the Definition List syntax, where ; denotes a title and : denotes a new line for the list under that item.&lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Use the Definition List syntax, where ; denotes a title and : denotes a new line for the list under that item.&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;--&amp;gt;&lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;--&amp;gt;&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&amp;lt;noinclude&amp;gt;The recipe shown here is just a placeholder - please replace this info with your own. This text won&#039;t show up in the final page.&amp;lt;/noinclude&amp;gt;&lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&amp;lt;noinclude&amp;gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;===&lt;/ins&gt;The recipe shown here is just a placeholder - please replace this info with your own. This text won&#039;t show up in the final page.&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;===&lt;/ins&gt;&amp;lt;/noinclude&amp;gt;&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;==Recipe==&lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;==Recipe==&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br /&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br /&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/table&gt;</summary>
		<author><name>John d</name></author>
	</entry>
	<entry>
		<id>https://wiki.nanofab.ucsb.edu/w/index.php?title=Template:Recipe&amp;diff=154328&amp;oldid=prev</id>
		<title>John d: comment help</title>
		<link rel="alternate" type="text/html" href="https://wiki.nanofab.ucsb.edu/w/index.php?title=Template:Recipe&amp;diff=154328&amp;oldid=prev"/>
		<updated>2017-08-03T21:53:32Z</updated>

		<summary type="html">&lt;p&gt;comment help&lt;/p&gt;
&lt;table style=&quot;background-color: #fff; color: #202122;&quot; data-mw=&quot;interface&quot;&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;tr class=&quot;diff-title&quot; lang=&quot;en&quot;&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;Revision as of 21:53, 3 August 2017&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 1:&lt;/td&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 1:&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-empty diff-side-deleted&quot;&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&amp;lt;!-- Please replace the recipe name and other info with your own. &lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-empty diff-side-deleted&quot;&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Use the Definition List syntax, where ; denotes a title and : denotes a new line for the list under that item.&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-empty diff-side-deleted&quot;&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;--&amp;gt;&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-empty diff-side-deleted&quot;&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&amp;lt;noinclude&amp;gt;The recipe shown here is just a placeholder - please replace this info with your own. This text won&#039;t show up in the final page.&amp;lt;/noinclude&amp;gt;&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;==Recipe==&lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;==Recipe==&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-empty diff-side-deleted&quot;&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br /&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&amp;lt;includeonly&amp;gt;[[category:Recipes]]&amp;lt;/includeonly&amp;gt;&lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&amp;lt;includeonly&amp;gt;[[category:Recipes]]&amp;lt;/includeonly&amp;gt;&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;;Recipe Name&lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;;Recipe Name&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;: SiOVert_MadeUp&lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;: SiOVert_MadeUp&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-empty diff-side-deleted&quot;&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br /&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-empty diff-side-deleted&quot;&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;;Tool&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-empty diff-side-deleted&quot;&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;: Panasonic ICP #2&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br /&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br /&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;;Description&lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;;Description&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/table&gt;</summary>
		<author><name>John d</name></author>
	</entry>
	<entry>
		<id>https://wiki.nanofab.ucsb.edu/w/index.php?title=Template:Recipe&amp;diff=154327&amp;oldid=prev</id>
		<title>John d: added headings, Charact section</title>
		<link rel="alternate" type="text/html" href="https://wiki.nanofab.ucsb.edu/w/index.php?title=Template:Recipe&amp;diff=154327&amp;oldid=prev"/>
		<updated>2017-08-03T21:43:25Z</updated>

		<summary type="html">&lt;p&gt;added headings, Charact section&lt;/p&gt;
&lt;table style=&quot;background-color: #fff; color: #202122;&quot; data-mw=&quot;interface&quot;&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;tr class=&quot;diff-title&quot; lang=&quot;en&quot;&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;Revision as of 21:43, 3 August 2017&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 1:&lt;/td&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 1:&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-empty diff-side-deleted&quot;&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;==Recipe==&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&amp;lt;includeonly&amp;gt;[[category:Recipes]]&amp;lt;/includeonly&amp;gt;&lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&amp;lt;includeonly&amp;gt;[[category:Recipes]]&amp;lt;/includeonly&amp;gt;&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;;Recipe Name&lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;;Recipe Name&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 20:&lt;/td&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 21:&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;: This recipe usually doesn&#039;t work.&lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;: This recipe usually doesn&#039;t work.&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;: Film will etch in HF&lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;: Film will etch in HF&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-empty diff-side-deleted&quot;&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br /&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-empty diff-side-deleted&quot;&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;-----&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-empty diff-side-deleted&quot;&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br /&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-empty diff-side-deleted&quot;&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;==Characterization==&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-empty diff-side-deleted&quot;&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[File:Al-thickness-variation-with-rate.jpg]]&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/table&gt;</summary>
		<author><name>John d</name></author>
	</entry>
	<entry>
		<id>https://wiki.nanofab.ucsb.edu/w/index.php?title=Template:Recipe&amp;diff=154326&amp;oldid=prev</id>
		<title>John d: 1st attempt, using definition list</title>
		<link rel="alternate" type="text/html" href="https://wiki.nanofab.ucsb.edu/w/index.php?title=Template:Recipe&amp;diff=154326&amp;oldid=prev"/>
		<updated>2017-08-03T21:39:45Z</updated>

		<summary type="html">&lt;p&gt;1st attempt, using definition list&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;&amp;lt;includeonly&amp;gt;[[category:Recipes]]&amp;lt;/includeonly&amp;gt;&lt;br /&gt;
;Recipe Name&lt;br /&gt;
: SiOVert_MadeUp&lt;br /&gt;
&lt;br /&gt;
;Description&lt;br /&gt;
: This recipe is made up, and deposits glass with lots of holes in it.&lt;br /&gt;
&lt;br /&gt;
;Recipe Parameters&lt;br /&gt;
: Ar = 20 sccm&lt;br /&gt;
: O2 = 10 sccm&lt;br /&gt;
: Pressure = 50 mT&lt;br /&gt;
: RF = 200 W&lt;br /&gt;
: Temperature = 200°C&lt;br /&gt;
&lt;br /&gt;
;Dep Rate&lt;br /&gt;
: 200 nm/min or 12,000 nm/sec&lt;br /&gt;
&lt;br /&gt;
;Notes&lt;br /&gt;
: Make sure sample is inside out before loading into tool.&lt;br /&gt;
: This recipe usually doesn&amp;#039;t work.&lt;br /&gt;
: Film will etch in HF&lt;/div&gt;</summary>
		<author><name>John d</name></author>
	</entry>
</feed>