<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://wiki.nanofab.ucsb.edu/w/index.php?action=history&amp;feed=atom&amp;title=UV_Ozone_Reactor</id>
	<title>UV Ozone Reactor - Revision history</title>
	<link rel="self" type="application/atom+xml" href="https://wiki.nanofab.ucsb.edu/w/index.php?action=history&amp;feed=atom&amp;title=UV_Ozone_Reactor"/>
	<link rel="alternate" type="text/html" href="https://wiki.nanofab.ucsb.edu/w/index.php?title=UV_Ozone_Reactor&amp;action=history"/>
	<updated>2026-09-18T12:25:42Z</updated>
	<subtitle>Revision history for this page on the wiki</subtitle>
	<generator>MediaWiki 1.43.9</generator>
	<entry>
		<id>https://wiki.nanofab.ucsb.edu/w/index.php?title=UV_Ozone_Reactor&amp;diff=162991&amp;oldid=prev</id>
		<title>Biljana: /* About */ adding data for UV ozone 20min on Si quarter that was previously BHF etched [no native oxide].</title>
		<link rel="alternate" type="text/html" href="https://wiki.nanofab.ucsb.edu/w/index.php?title=UV_Ozone_Reactor&amp;diff=162991&amp;oldid=prev"/>
		<updated>2025-04-23T18:16:06Z</updated>

		<summary type="html">&lt;p&gt;&lt;span class=&quot;autocomment&quot;&gt;About: &lt;/span&gt; adding data for UV ozone 20min on Si quarter that was previously BHF etched [no native oxide].&lt;/p&gt;
&lt;table style=&quot;background-color: #fff; color: #202122;&quot; data-mw=&quot;interface&quot;&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;tr class=&quot;diff-title&quot; lang=&quot;en&quot;&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;Revision as of 18:16, 23 April 2025&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 16:&lt;/td&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 16:&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*[https://wiki.nanofab.ucsb.edu/w/images/3/3e/UV_Ozone_SOP_Rev_A.pdf UV Ozone Reactor SOP]&lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*[https://wiki.nanofab.ucsb.edu/w/images/3/3e/UV_Ozone_SOP_Rev_A.pdf UV Ozone Reactor SOP]&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*[//wiki.nanotech.ucsb.edu/wiki/images/7/79/UV_Ozone_Manual_Jelight_M-144AX.pdf UV Ozone Manual]&lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*[//wiki.nanotech.ucsb.edu/wiki/images/7/79/UV_Ozone_Manual_Jelight_M-144AX.pdf UV Ozone Manual]&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-empty diff-side-deleted&quot;&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*Data [Si quarter, 20min UV Ozone ~1nm thick oxide]&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/table&gt;</summary>
		<author><name>Biljana</name></author>
	</entry>
	<entry>
		<id>https://wiki.nanofab.ucsb.edu/w/index.php?title=UV_Ozone_Reactor&amp;diff=161276&amp;oldid=prev</id>
		<title>Sawyer l: Added an SOP</title>
		<link rel="alternate" type="text/html" href="https://wiki.nanofab.ucsb.edu/w/index.php?title=UV_Ozone_Reactor&amp;diff=161276&amp;oldid=prev"/>
		<updated>2023-08-29T16:17:02Z</updated>

		<summary type="html">&lt;p&gt;Added an SOP&lt;/p&gt;
&lt;table style=&quot;background-color: #fff; color: #202122;&quot; data-mw=&quot;interface&quot;&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;tr class=&quot;diff-title&quot; lang=&quot;en&quot;&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;Revision as of 16:17, 29 August 2023&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 14:&lt;/td&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 14:&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;==Documentation==&lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;==Documentation==&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br /&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br /&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-empty diff-side-deleted&quot;&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*[https://wiki.nanofab.ucsb.edu/w/images/3/3e/UV_Ozone_SOP_Rev_A.pdf UV Ozone Reactor SOP]&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*[[UV Ozone Quick Start|Quick Start]]&lt;/div&gt;&lt;/td&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-empty diff-side-added&quot;&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*[//wiki.nanotech.ucsb.edu/wiki/images/7/79/UV_Ozone_Manual_Jelight_M-144AX.pdf UV Ozone Manual]&lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*[//wiki.nanotech.ucsb.edu/wiki/images/7/79/UV_Ozone_Manual_Jelight_M-144AX.pdf UV Ozone Manual]&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/table&gt;</summary>
		<author><name>Sawyer l</name></author>
	</entry>
	<entry>
		<id>https://wiki.nanofab.ucsb.edu/w/index.php?title=UV_Ozone_Reactor&amp;diff=160411&amp;oldid=prev</id>
		<title>Sawyer l: Updated tool template</title>
		<link rel="alternate" type="text/html" href="https://wiki.nanofab.ucsb.edu/w/index.php?title=UV_Ozone_Reactor&amp;diff=160411&amp;oldid=prev"/>
		<updated>2022-09-08T17:09:17Z</updated>

		<summary type="html">&lt;p&gt;Updated tool template&lt;/p&gt;
&lt;table style=&quot;background-color: #fff; color: #202122;&quot; data-mw=&quot;interface&quot;&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;tr class=&quot;diff-title&quot; lang=&quot;en&quot;&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;Revision as of 17:09, 8 September 2022&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 4:&lt;/td&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 4:&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;|super= Lee Sawyer&lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;|super= Lee Sawyer&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;|super2= Tony Bosch&lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;|super2= Tony Bosch&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;|model=&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;M-&lt;/del&gt;144AX&lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;|model=144AX&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;|location=Bay 5&lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;|location=Bay 5&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;|description = UV Ozone &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;Reactor&lt;/del&gt;&lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;|description = UV Ozone &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;Cleaner&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;|manufacturer = Jelight&lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;|manufacturer = Jelight&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;}} &lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;}} &lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/table&gt;</summary>
		<author><name>Sawyer l</name></author>
	</entry>
	<entry>
		<id>https://wiki.nanofab.ucsb.edu/w/index.php?title=UV_Ozone_Reactor&amp;diff=160410&amp;oldid=prev</id>
		<title>Sawyer l: About section updated</title>
		<link rel="alternate" type="text/html" href="https://wiki.nanofab.ucsb.edu/w/index.php?title=UV_Ozone_Reactor&amp;diff=160410&amp;oldid=prev"/>
		<updated>2022-09-08T17:07:56Z</updated>

		<summary type="html">&lt;p&gt;About section updated&lt;/p&gt;
&lt;table style=&quot;background-color: #fff; color: #202122;&quot; data-mw=&quot;interface&quot;&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;tr class=&quot;diff-title&quot; lang=&quot;en&quot;&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;Revision as of 17:07, 8 September 2022&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 10:&lt;/td&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 10:&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;}} &lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;}} &lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;==About==&lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;==About==&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-empty diff-side-deleted&quot;&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;UV+O (atomic oxygen) cleaning method is a photosensitized oxidation process in which the contaminant molecules of photo-resists, resins, human skin oils, cleaning solvent residues, silicone oils, and flux are excited and/or dissociated by the absorption of short-wavelength UV radiation. Near atomically clean surfaces can be achieved in less than one minute. In addition, this process does not damage any sensitive device structures of MOS gate oxide. The system can be used for oxygen activation, etching or oxidation of a surface without ion bombardment.&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The UV Ozone is manufactured by Jelight, model M-144AX.  It can be used for Oxygen activation, etching or oxidation of a surface without ion bombardment.&lt;/div&gt;&lt;/td&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-empty diff-side-added&quot;&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br /&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br /&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;==Documentation==&lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;==Documentation==&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/table&gt;</summary>
		<author><name>Sawyer l</name></author>
	</entry>
	<entry>
		<id>https://wiki.nanofab.ucsb.edu/w/index.php?title=UV_Ozone_Reactor&amp;diff=160341&amp;oldid=prev</id>
		<title>Silva at 17:52, 30 August 2022</title>
		<link rel="alternate" type="text/html" href="https://wiki.nanofab.ucsb.edu/w/index.php?title=UV_Ozone_Reactor&amp;diff=160341&amp;oldid=prev"/>
		<updated>2022-08-30T17:52:41Z</updated>

		<summary type="html">&lt;p&gt;&lt;/p&gt;
&lt;table style=&quot;background-color: #fff; color: #202122;&quot; data-mw=&quot;interface&quot;&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;tr class=&quot;diff-title&quot; lang=&quot;en&quot;&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;Revision as of 17:52, 30 August 2022&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 1:&lt;/td&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 1:&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;{{&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;tool&lt;/del&gt;|{{PAGENAME}}&lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;{{&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;tool2&lt;/ins&gt;|{{PAGENAME}}&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;|picture=Ozone.jpg&lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;|picture=Ozone.jpg&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;|type = Dry Etch &lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;|type = Dry Etch &lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;|super= Lee Sawyer&lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;|super= Lee Sawyer&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-empty diff-side-deleted&quot;&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;|super2= Tony Bosch&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;|model=M-144AX&lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;|model=M-144AX&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;|location=Bay 5&lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;|location=Bay 5&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/table&gt;</summary>
		<author><name>Silva</name></author>
	</entry>
	<entry>
		<id>https://wiki.nanofab.ucsb.edu/w/index.php?title=UV_Ozone_Reactor&amp;diff=157785&amp;oldid=prev</id>
		<title>Jcrode: Text replacement - &quot;www.nanotech.ucsb.edu/wiki/&quot; to &quot;wiki.nanotech.ucsb.edu/wiki/&quot;</title>
		<link rel="alternate" type="text/html" href="https://wiki.nanofab.ucsb.edu/w/index.php?title=UV_Ozone_Reactor&amp;diff=157785&amp;oldid=prev"/>
		<updated>2020-04-07T01:29:52Z</updated>

		<summary type="html">&lt;p&gt;Text replacement - &amp;quot;www.nanotech.ucsb.edu/wiki/&amp;quot; to &amp;quot;wiki.nanotech.ucsb.edu/wiki/&amp;quot;&lt;/p&gt;
&lt;table style=&quot;background-color: #fff; color: #202122;&quot; data-mw=&quot;interface&quot;&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;tr class=&quot;diff-title&quot; lang=&quot;en&quot;&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;Revision as of 01:29, 7 April 2020&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 14:&lt;/td&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 14:&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br /&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br /&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*[[UV Ozone Quick Start|Quick Start]]&lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*[[UV Ozone Quick Start|Quick Start]]&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*[//&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;www&lt;/del&gt;.nanotech.ucsb.edu/wiki/images/7/79/UV_Ozone_Manual_Jelight_M-144AX.pdf UV Ozone Manual]&lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*[//&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;wiki&lt;/ins&gt;.nanotech.ucsb.edu/wiki/images/7/79/UV_Ozone_Manual_Jelight_M-144AX.pdf UV Ozone Manual]&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/table&gt;</summary>
		<author><name>Jcrode</name></author>
	</entry>
	<entry>
		<id>https://wiki.nanofab.ucsb.edu/w/index.php?title=UV_Ozone_Reactor&amp;diff=156742&amp;oldid=prev</id>
		<title>Sawyer l: heading change</title>
		<link rel="alternate" type="text/html" href="https://wiki.nanofab.ucsb.edu/w/index.php?title=UV_Ozone_Reactor&amp;diff=156742&amp;oldid=prev"/>
		<updated>2019-09-11T22:33:07Z</updated>

		<summary type="html">&lt;p&gt;heading change&lt;/p&gt;
&lt;table style=&quot;background-color: #fff; color: #202122;&quot; data-mw=&quot;interface&quot;&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;tr class=&quot;diff-title&quot; lang=&quot;en&quot;&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;Revision as of 22:33, 11 September 2019&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 8:&lt;/td&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 8:&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;|manufacturer = Jelight&lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;|manufacturer = Jelight&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;}} &lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;}} &lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;==&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt; &lt;/del&gt;About&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;  &lt;/del&gt;==&lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;==About==&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The UV Ozone is manufactured by Jelight, model M-144AX.  It can be used for Oxygen activation, etching or oxidation of a surface without ion bombardment.&lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The UV Ozone is manufactured by Jelight, model M-144AX.  It can be used for Oxygen activation, etching or oxidation of a surface without ion bombardment.&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br /&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br /&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-empty diff-side-deleted&quot;&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;==Documentation==&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Operating Procedures ==&lt;/div&gt;&lt;/td&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-empty diff-side-added&quot;&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-empty diff-side-deleted&quot;&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br /&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;* [[UV Ozone Quick Start|Quick Start]]&lt;/div&gt;&lt;/td&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-empty diff-side-added&quot;&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt; &lt;/del&gt;[[&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;Media:&lt;/del&gt;UV Ozone &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;Manual&lt;/del&gt; &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;Jelight M-144AX.pdf&lt;/del&gt;|&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;UV Ozone&lt;/del&gt; &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;Manual&lt;/del&gt;]]&lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*[[UV Ozone &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;Quick&lt;/ins&gt; &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;Start&lt;/ins&gt;|&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;Quick&lt;/ins&gt; &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;Start&lt;/ins&gt;]]&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-empty diff-side-deleted&quot;&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*[//www.nanotech.ucsb.edu/wiki/images/7/79/UV_Ozone_Manual_Jelight_M-144AX.pdf UV Ozone Manual]&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/table&gt;</summary>
		<author><name>Sawyer l</name></author>
	</entry>
	<entry>
		<id>https://wiki.nanofab.ucsb.edu/w/index.php?title=UV_Ozone_Reactor&amp;diff=156244&amp;oldid=prev</id>
		<title>Sawyer l: /* About */</title>
		<link rel="alternate" type="text/html" href="https://wiki.nanofab.ucsb.edu/w/index.php?title=UV_Ozone_Reactor&amp;diff=156244&amp;oldid=prev"/>
		<updated>2019-04-11T17:46:14Z</updated>

		<summary type="html">&lt;p&gt;&lt;span class=&quot;autocomment&quot;&gt;About&lt;/span&gt;&lt;/p&gt;
&lt;table style=&quot;background-color: #fff; color: #202122;&quot; data-mw=&quot;interface&quot;&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;tr class=&quot;diff-title&quot; lang=&quot;en&quot;&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;Revision as of 17:46, 11 April 2019&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 2:&lt;/td&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 2:&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;|picture=Ozone.jpg&lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;|picture=Ozone.jpg&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;|type = Dry Etch &lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;|type = Dry Etch &lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;|super= &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;Tony&lt;/del&gt; &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;Bosch&lt;/del&gt;&lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;|super= &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;Lee&lt;/ins&gt; &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;Sawyer&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;|model=M-144AX&lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;|model=M-144AX&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;|location=Bay 5&lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;|location=Bay 5&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/table&gt;</summary>
		<author><name>Sawyer l</name></author>
	</entry>
	<entry>
		<id>https://wiki.nanofab.ucsb.edu/w/index.php?title=UV_Ozone_Reactor&amp;diff=155296&amp;oldid=prev</id>
		<title>John d: add description and model</title>
		<link rel="alternate" type="text/html" href="https://wiki.nanofab.ucsb.edu/w/index.php?title=UV_Ozone_Reactor&amp;diff=155296&amp;oldid=prev"/>
		<updated>2018-07-17T22:57:01Z</updated>

		<summary type="html">&lt;p&gt;add description and model&lt;/p&gt;
&lt;table style=&quot;background-color: #fff; color: #202122;&quot; data-mw=&quot;interface&quot;&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;tr class=&quot;diff-title&quot; lang=&quot;en&quot;&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;Revision as of 22:57, 17 July 2018&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 3:&lt;/td&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 3:&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;|type = Dry Etch &lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;|type = Dry Etch &lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;|super= Tony Bosch&lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;|super= Tony Bosch&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-empty diff-side-deleted&quot;&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;|model=M-144AX&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;|location=Bay 5&lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;|location=Bay 5&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;|description = &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;?&lt;/del&gt;&lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;|description = &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;UV Ozone Reactor&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;|manufacturer = &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;?&lt;/del&gt;&lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;|manufacturer = &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;Jelight&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;}} &lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;}} &lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== About  ==&lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== About  ==&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-empty diff-side-deleted&quot;&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The UV Ozone is manufactured by Jelight, model M-144AX.  It can be used for Oxygen activation, etching or oxidation of a surface without ion bombardment.&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br /&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br /&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Operating Procedures ==&lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Operating Procedures ==&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;* [[UV Ozone Quick Start|Quick Start]]&lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;* [[UV Ozone Quick Start|Quick Start]]&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;* [Media:UV Ozone Manual Jelight M-144AX.pdf]&lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;* &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;[&lt;/ins&gt;[Media:UV Ozone Manual Jelight M-144AX.pdf&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;|UV Ozone Manual]&lt;/ins&gt;]&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/table&gt;</summary>
		<author><name>John d</name></author>
	</entry>
	<entry>
		<id>https://wiki.nanofab.ucsb.edu/w/index.php?title=UV_Ozone_Reactor&amp;diff=155295&amp;oldid=prev</id>
		<title>John d: bullet list</title>
		<link rel="alternate" type="text/html" href="https://wiki.nanofab.ucsb.edu/w/index.php?title=UV_Ozone_Reactor&amp;diff=155295&amp;oldid=prev"/>
		<updated>2018-07-17T22:53:58Z</updated>

		<summary type="html">&lt;p&gt;bullet list&lt;/p&gt;
&lt;table style=&quot;background-color: #fff; color: #202122;&quot; data-mw=&quot;interface&quot;&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;tr class=&quot;diff-title&quot; lang=&quot;en&quot;&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;Revision as of 22:53, 17 July 2018&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 7:&lt;/td&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 7:&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;|manufacturer = ?&lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;|manufacturer = ?&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;}} &lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;}} &lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;= About  =&lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;=&lt;/ins&gt;= About  &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;=&lt;/ins&gt;=&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br /&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br /&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Operating Procedures ==&lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Operating Procedures ==&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[UV Ozone Quick Start|Quick Start]]&lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;* &lt;/ins&gt;[[UV Ozone Quick Start|Quick Start]]&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;[&lt;/del&gt;[Media:UV Ozone Manual Jelight M-144AX.pdf&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;]&lt;/del&gt;]&lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;* &lt;/ins&gt;[Media:UV Ozone Manual Jelight M-144AX.pdf]&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/table&gt;</summary>
		<author><name>John d</name></author>
	</entry>
</feed>