Solvent Benches: Difference between revisions
Jump to navigation
Jump to search
Content deleted Content added
No edit summary |
Redirected page to Wet Benches#Solvent Cleaning Benches |
||
| Line 1: | Line 1: | ||
#redirect [[Wet_Benches#Solvent_Cleaning_Benches]] |
|||
{{tool|{{PAGENAME}} |
|||
|picture=SolventBench.jpg |
|||
|type = Wet Processing |
|||
|super= Aidan Hopkins |
|||
|phone=(805)839-3918x208 |
|||
|location=? |
|||
|email=hopkins@ece.ucsb.edu |
|||
|description = Custom Solvent Wet Bench |
|||
|manufacturer = Pure Aire Corporation |
|||
|materials = |
|||
}} |
|||
=About= |
|||
The facility contains 4 stainless steel solvent benches for general processing using organic solvents. All solvent waste (except for certain chemicals that are collected) are poured into cups and centrally collected. The benches consist of 2 embedded variable power Crest-ultrasonic units, one kept at 70°C for heating resist strippers and the other kept at room temperature for general solvent work. Laminar flow fume hoods with hepa filtration. Nitrogen guns are also on both sides of the bench for drying samples. Digital stirring hotplates are included for heating and stirring of resist stripers only (No solvent heating). POLOS spin dryers are included in the benches. All processes are done in user-supplied glassware. Solvents are stored in large steel flammable materials cabinets. Two people may use the bench at a time and protective gear such as proper gloves must be used. Solvents supplied by the laboratory are: Acetone, Methanol, Isopropanol, MIBK, MEK, Toluene, EBR100. PR strippers supplied by the lab are: 1165 (NMP), AZ300T (NMP + TMAH), PRX-127. Other chemicals should be OK'd by laboratory staff prior to use in the laboratory. |
|||
=Deatailed Specifications= |
|||
*2 7" x 10" Crest Ultrasonic Tanks with heating / variable power |
|||
*2 Nitrogen guns for sample drying |
|||
*Solvent based processing; '''NO SOLVENT HEATING''' |
|||
*Organic material removal up to 80°C |
|||
*Cyanide-based plating and etching ('''NO ACIDS''' at bench) |
|||
*Digital hot plate stirrers |
|||
*POLOS rinse dryers |
|||
Latest revision as of 14:44, 12 July 2012
Redirect to: