MediaWiki:Common.js: Difference between revisions
Jump to navigation
Jump to search
Content deleted Content added
No edit summary |
Blanked the page |
||
| (6 intermediate revisions by one other user not shown) | |||
| Line 1: | Line 1: | ||
/** Collapsible tables ********************************************************* |
|||
* |
|||
* Description: Allows tables to be collapsed, showing only the header. See |
|||
* http://www.mediawiki.org/wiki/Manual:Collapsible_tables. |
|||
* Maintainers: [[en:User:R. Koot]] |
|||
*/ |
|||
var autoCollapse = 2; |
|||
var collapseCaption = 'hide'; |
|||
var expandCaption = 'show'; |
|||
.tablecollapse span.mw-collapsible-toggle{ float:right; } |
|||
.collapse span.mw-collapsible-toggle { float: left; } |
|||
function collapseTable( tableIndex ) { |
|||
var Button = document.getElementById( 'collapseButton' + tableIndex ); |
|||
var Table = document.getElementById( 'collapsibleTable' + tableIndex ); |
|||
if ( !Table || !Button ) { |
|||
return false; |
|||
} |
|||
var Rows = Table.rows; |
|||
if ( Button.firstChild.data == collapseCaption ) { |
|||
for ( var i = 1; i < Rows.length; i++ ) { |
|||
Rows[i].style.display = 'none'; |
|||
} |
|||
Button.firstChild.data = expandCaption; |
|||
} else { |
|||
for ( var i = 1; i < Rows.length; i++ ) { |
|||
Rows[i].style.display = Rows[0].style.display; |
|||
} |
|||
Button.firstChild.data = collapseCaption; |
|||
} |
|||
} |
|||
function createCollapseButtons() { |
|||
var tableIndex = 0; |
|||
var NavigationBoxes = new Object(); |
|||
var Tables = document.getElementsByTagName( 'table' ); |
|||
for ( var i = 0; i < Tables.length; i++ ) { |
|||
if ( hasClass( Tables[i], 'collapsible' ) ) { |
|||
/* only add button and increment count if there is a header row to work with */ |
|||
var HeaderRow = Tables[i].getElementsByTagName( 'tr' )[0]; |
|||
if ( !HeaderRow ) { |
|||
continue; |
|||
} |
|||
var Header = HeaderRow.getElementsByTagName( 'th' )[0]; |
|||
if ( !Header ) { |
|||
continue; |
|||
} |
|||
NavigationBoxes[tableIndex] = Tables[i]; |
|||
Tables[i].setAttribute( 'id', 'collapsibleTable' + tableIndex ); |
|||
var Button = document.createElement( 'span' ); |
|||
var ButtonLink = document.createElement( 'a' ); |
|||
var ButtonText = document.createTextNode( collapseCaption ); |
|||
Button.className = 'collapseButton'; // Styles are declared in [[MediaWiki:Common.css]] |
|||
ButtonLink.style.color = Header.style.color; |
|||
ButtonLink.setAttribute( 'id', 'collapseButton' + tableIndex ); |
|||
ButtonLink.setAttribute( 'href', "javascript:collapseTable(" + tableIndex + ");" ); |
|||
ButtonLink.appendChild( ButtonText ); |
|||
Button.appendChild( document.createTextNode( '[' ) ); |
|||
Button.appendChild( ButtonLink ); |
|||
Button.appendChild( document.createTextNode( ']' ) ); |
|||
Header.insertBefore( Button, Header.childNodes[0] ); |
|||
tableIndex++; |
|||
} |
|||
} |
|||
for ( var i = 0; i < tableIndex; i++ ) { |
|||
if ( hasClass( NavigationBoxes[i], 'collapsed' ) || ( tableIndex >= autoCollapse && hasClass( NavigationBoxes[i], 'autocollapse' ) ) ) { |
|||
collapseTable( i ); |
|||
} else if ( hasClass( NavigationBoxes[i], 'innercollapse' ) ) { |
|||
var element = NavigationBoxes[i]; |
|||
while ( element = element.parentNode ) { |
|||
if ( hasClass( element, 'outercollapse' ) ) { |
|||
collapseTable( i ); |
|||
break; |
|||
} |
|||
} |
|||
} |
|||
} |
|||
} |
|||
addOnloadHook( createCollapseButtons ); |
|||
/** Test if an element has a certain class ************************************** |
|||
* |
|||
* Description: Uses regular expressions and caching for better performance. |
|||
* Maintainers: [[User:Mike Dillon]], [[User:R. Koot]], [[User:SG]] |
|||
*/ |
|||
var hasClass = ( function() { |
|||
var reCache = {}; |
|||
return function( element, className ) { |
|||
return ( reCache[className] ? reCache[className] : ( reCache[className] = new RegExp( "(?:\\s|^)" + className + "(?:\\s|$)" ) ) ).test( element.className ); |
|||
}; |
|||
})(); |
|||