Test Data of etching SiO2 with CHF3/CF4: Difference between revisions

From UCSB Nanofab Wiki
Jump to navigation Jump to search
(add a SEM)
(add a data point)
Line 61: Line 61:
|5/19/2021
|5/19/2021
|I22102
|I22102
|101
|163
|1.11
|1.11
|Etch time=130 sec
|
|[https://wiki.nanotech.ucsb.edu/w/images/4/4c/I2210214.pdf]
|[https://wiki.nanotech.ucsb.edu/w/images/4/4c/I2210214.pdf]
|}
|}

Revision as of 02:30, 20 May 2021

ICP#2: 0.5Pa, 50/900W, CHF3/CF4=10/30 sccm, time=210 sec
Date Sample# Etch Rate (nm/min) Etch Selectivity (SiO2/PR) Averaged Sidewall Angle (o) SEM Images
10/5/2018 SiO2#02 160 1.2 82.1 [1]
1/28/2019 I21901 146 1.23 [2]
3/6/2019 I21904 151 1.23 85.6 [3]
7/18/2019 I21905 162 1.37 [4]
1/16/2020 I22001 149 1.21 [5]
8/9/2020 I22002 102 0.86 caused by air leaking to CHF3 channel [6]
1/7/2021 I22101 144 1.20 [7]
5/19/2021 I22102 163 1.11 Etch time=130 sec [8]