Difference between revisions of "IR Aligner (SUSS MJB-3 IR)"
(add SOP link, doc section) |
(→About: correct about and spec section) |
||
Line 12: | Line 12: | ||
}} | }} | ||
==About== | ==About== | ||
− | This is a high-performance mask aligner | + | This is a high-performance contact mask aligner with backside alignment capability for opaque materials using IR. It is a versatile, user-friendly compact unit that has a foot print of 600 x 800 mm². The resolution (depending on contact mode, optics and exposure wavelength and "operator technique") is far into the submicron region. The aligner is configured for the near-UV window (365 and 405 nm) and both left and has the "vacuum contact" option extending resolution to ~0.5 microns. Higher resolution optic systems that can be supplied by Suss are given below. The standard soft and hard contact modes of mechanical and pneumatic pressure respectively, only give resolution to 1-2 microns. Exposures can be done on substrates from small "piece parts" of less than 1 cm square to substrates of 3 inch diameter or square. Masks up to 4 inches in size can be used although patterns should be well away from the maskplate edges due to the fact such plates can only be shifted ~ x mm and substrate chuck +/- 3 mm. |
==Detailed Specifications== | ==Detailed Specifications== | ||
Line 20: | Line 20: | ||
*Wafer / substrate thickness: 0-4.5 mm | *Wafer / substrate thickness: 0-4.5 mm | ||
*Exposure optics: | *Exposure optics: | ||
− | ** | + | **280-450 nm/200 W mercury lamp (can filter to 350 nm) |
− | |||
− | |||
*Additional manufacturer options (none installed on our systems): | *Additional manufacturer options (none installed on our systems): | ||
**DUV (polychromatic): 240-260 nm/350 W Cd-Xe lamp; 0.2 micron resolution (PMMA) | **DUV (polychromatic): 240-260 nm/350 W Cd-Xe lamp; 0.2 micron resolution (PMMA) | ||
Line 44: | Line 42: | ||
*(Note: The vacuum contact mode is not allowed in the ITA System) | *(Note: The vacuum contact mode is not allowed in the ITA System) | ||
− | == Documentation == | + | ==Documentation== |
− | * [https://www.nanotech.ucsb.edu/wiki/images/d/de/MJB_3_SOP.pdf MJB 3 Standard Operating Procedure] | + | *[https://www.nanotech.ucsb.edu/wiki/images/d/de/MJB_3_SOP.pdf MJB 3 Standard Operating Procedure] |
Revision as of 11:23, 24 October 2019
|
About
This is a high-performance contact mask aligner with backside alignment capability for opaque materials using IR. It is a versatile, user-friendly compact unit that has a foot print of 600 x 800 mm². The resolution (depending on contact mode, optics and exposure wavelength and "operator technique") is far into the submicron region. The aligner is configured for the near-UV window (365 and 405 nm) and both left and has the "vacuum contact" option extending resolution to ~0.5 microns. Higher resolution optic systems that can be supplied by Suss are given below. The standard soft and hard contact modes of mechanical and pneumatic pressure respectively, only give resolution to 1-2 microns. Exposures can be done on substrates from small "piece parts" of less than 1 cm square to substrates of 3 inch diameter or square. Masks up to 4 inches in size can be used although patterns should be well away from the maskplate edges due to the fact such plates can only be shifted ~ x mm and substrate chuck +/- 3 mm.
Detailed Specifications
- Wafer size: 3" max. for vacuum mode; 4” for soft contact (3” x 3” exposure area)
- Substrate size: 3" x 3" max.
- Wafer / substrate thickness: 0-4.5 mm
- Exposure optics:
- 280-450 nm/200 W mercury lamp (can filter to 350 nm)
- Additional manufacturer options (none installed on our systems):
- DUV (polychromatic): 240-260 nm/350 W Cd-Xe lamp; 0.2 micron resolution (PMMA)
- DUV (monochromatic): 248 nm/KrF excimer laser; 0.3 micron resolution (PMMA)
- 193 nm/ArF excimer laser; 0.2 micron resolution (PMMA)
- Uniformity:
- ±3% over 2" diameter
- ±5% over 3" diameter
Special Notes / Additional Comments
- All units have 200 W mercury lamps
- Infrared Transmission Alignment System
- All models can be equipped for back side alignment using infrared light; this is used when a mask needs to be aligned to features on the substrate backside but exposed to light on the front or resist side
- For processes using this tool please go to the contact lithography process page
- This includes:
- Modified alignment stage
- Motor positioned IR light source under chuck
- Special glass chuck transparent to IR but opaque to UV and visible light
- In-line video camera/monitor for substrate backside viewing and alignment to front-side
- (Note: The vacuum contact mode is not allowed in the ITA System)