|picture=Fluorescence.jpg
|picture=Fluorescence.jpg
|type = Inspection, Test and Characterization
|type = Inspection, Test and Characterization
|super= Tony Bosch
|super= Demis D. John
|location=Bay 6
|location=Bay 6
|description =
|description = Optical Microscope
|manufacturer = Olympus
|manufacturer = Olympus
|model = MX51
|materials =
|materials =
|toolid=
|toolid=
}}
}}
=About=
=About=
System for general purpose imaging. The system has bright field, dark-field, and DIC imaging modes. Screen captures and measurements on samples can be made through use of Olympus' Streams Essential Software, installed on the attached computer.
System for general purpose imaging. The system has bright field, dark-field, DIC imaging mode and Three fluorescence filters. Screen captures and calibrated measurements can be made through use of native Olympus' Streams Essential Software, installed on the attached computer.


=Detailed Specifications=
=Detailed Specifications=
* Digital image capture & calibrated measurement via integrated Olympus Streams Essentials software.
* Native ''Olympus Streams Essentials'' software & Camera:
** Digital image capture & calibrated measurement (calibrations locked)
* Objectives: 5x, 10x, 20x, 50x, 100x, 150x
* Objectives: 5x, 10x, 20x, 50x, 100x, 150x
* Reflected (Episcopic) & Transmitted (Diascopic) Illumination modes
* Reflected (Episcopic) & Transmitted (Diascopic) Illumination modes

Latest revision as of 18:09, 15 April 2020

Fluorescence Microscope (Olympus MX51)
Tool Type Inspection, Test and Characterization
Location Bay 6
Supervisor Demis D. John
Supervisor Phone (805) 893-5934
Supervisor E-Mail demis@ucsb.edu
Description Optical Microscope
Manufacturer Olympus
Model MX51


About

System for general purpose imaging. The system has bright field, dark-field, DIC imaging mode and Three fluorescence filters. Screen captures and calibrated measurements can be made through use of native Olympus' Streams Essential Software, installed on the attached computer.

Detailed Specifications

  • Native Olympus Streams Essentials software & Camera:
    • Digital image capture & calibrated measurement (calibrations locked)
  • Objectives: 5x, 10x, 20x, 50x, 100x, 150x
  • Reflected (Episcopic) & Transmitted (Diascopic) Illumination modes
  • Filters via rotatable selector:
    • BF: Bright Field normal top-illuminated imaging
    • DF: Dark-Field imaging
    • DIC: Differential Interference Contrast "Nomarski" Imaging. Also requires "DIC-R" prism to be inserted. Polarization manually selected on DIC-R prism.
  • Fluorescence Filters (see Olympus tutorial):
    • You must contact Tony Bosch for training on Fluorescence before using this feature!!!
    • WB: "Blue" Fluorescence Filter. Excitation: 450-480nm / Dichroic 500nm / Barrier 515nm+
    • WG: "Green" Fluorescence Filter. Excitation: 510-550nm / Dichroic 570nm / Barrier 590nm+
    • WU: "Ultraviolet" Fluorescence Filter. Excitation: 330-385nm / Dichroic 400nm / Barrier 420nm+