GoPro Hero8 Black (Internal): Difference between revisions
→Trainings via Webmeeting (Zoom): updates |
link to Uploading instructions |
||
| (11 intermediate revisions by the same user not shown) | |||
| Line 1: | Line 1: | ||
[[File:Photo - GoPro Black 8 and Headstrap.png|alt=Photo of Gopro camera attached to wearable headstrap.|thumb|230x230px|GoPro Black 8 and Headstrap, used for recording trainings]] |
|||
Use this camera with various mounts, to record training videos for your tools. |
Use this camera with various mounts, to record training videos for your tools. It records spoken audio very well, automatically canceling much of the background noise. |
||
You can edit the videos after the fact, but it's not required - a "good enough" video even with mistakes or corrections would be fine. |
You can edit the videos after the fact, but it's not required - a "good enough" video even with mistakes or corrections would be fine. |
||
| Line 6: | Line 7: | ||
These is an initial draft of instructions - please feel free to edit! -- Demis 2020-07-02 |
These is an initial draft of instructions - please feel free to edit! -- Demis 2020-07-02 |
||
This procedure uses our GoPro Black 8, and a headstrap to wear it while recording. |
|||
== Procedure for recording == |
== Procedure for recording == |
||
| Line 11: | Line 13: | ||
=== Outside the lab, before your training === |
=== Outside the lab, before your training === |
||
* Fully charge your smartphone |
* Fully charge your smartphone |
||
* GoPro |
* GoPro 2 spare batteries - make sure both are charged. |
||
** We have a 2-battery charger for keeping the spares fully charged |
|||
** Batteries charge while inserted into the GoPro camera, and then plug the USB cable in. |
|||
** Note that the GoPro USB cable is a high-quality (high data rate) USB-C/USB-A cable - cheaper versions usually ''don't work,'' so don't lose this cable! |
** Note that the GoPro USB cable is a high-quality (high data rate) USB-C/USB-A cable - cheaper versions usually ''don't work,'' so don't lose this cable! |
||
* Download smartphone app called "GoPro" by the company "GoPro, Inc." to your own |
* Download smartphone app called "GoPro" by the company "GoPro, Inc." to your own smartphone. |
||
* [[File:GoPro H8b training - Smartphone App.jpg|none|thumb|200x200px| The "real" GoPro App in the Apple App Store. Beware of cheap imitations. ]] |
* [[File:GoPro H8b training - Smartphone App.jpg|none|thumb|200x200px| The "real" GoPro App in the Apple App Store. Beware of cheap imitations. ]] |
||
* Turn on the GoPro camera (hold down power button on the side) |
* Turn on the GoPro camera (hold down power button on the side) |
||
| Line 23: | Line 25: | ||
**#* Open the utility drawer by swiping from the top to the bottom of the touch display, then select "Preferences." |
**#* Open the utility drawer by swiping from the top to the bottom of the touch display, then select "Preferences." |
||
**#* Select "Connections" and then tap on "Connect Device." |
**#* Select "Connections" and then tap on "Connect Device." |
||
**#* Tap on "GoPro App" to put your camera in pairing mode.<span name="HERO6Black"></span> |
**#*<span name="HERO6Black"></span>Tap on "GoPro App" to put your camera in pairing mode.<span name="HERO6Black"></span> |
||
**#* ''Optional'': At this point, you can tap on the "i" icon |
**#* ''Optional'': At this point, you can tap on the "i" icon i<span name="HERO6Black"></span>n the top right corner to see your WiFi name and password. |
||
**# Open the GoPro App on your SmartPhone: |
**# Open the GoPro App on your SmartPhone: |
||
**#* Select the Camera logo at the bottom left corner of the app and it will automatically begin scanning for your camera |
**#* Select the Camera logo at the bottom left corner of the app and it will automatically begin scanning for your camera |
||
| Line 35: | Line 37: | ||
** ''Detailed Instructions for Live Preview are below.'' |
** ''Detailed Instructions for Live Preview are below.'' |
||
* Adjust the angle of the camera so the preview shows what you’re looking at. You want to be "naturally" looking at something, and make sure the GoPro shows the same thing. |
* Adjust the angle of the camera so the preview shows what you’re looking at. You want to be "naturally" looking at something, and make sure the GoPro shows the same thing. |
||
** Usually the headmount will aim ''high'' - looking above what your eyes are looking at, so adjust it down. |
** Usually the headmount will aim ''high'' - looking above what your eyes are looking at, so adjust it to point down, typically ~30-40° downwards. |
||
=== In the Lab: Recording your video === |
=== In the Lab: Recording your video === |
||
* ''(optional) Bring wired or bluetooth headphones that you can use with your smartphone - this is only for listening to video while in the lab. The "live" audio will be from the GoPro's built-in Mic - it works fine.'' |
* ''(optional) Bring wired or bluetooth headphones that you can use with your smartphone - this is only for listening to video while in the lab. The "live" audio will be from the GoPro's built-in Mic - it works fine in the lab.'' |
||
* Turn on camera - hold down the power button on the side. |
* Turn on camera - hold down the power button on the side. |
||
* Place camera on mount - either head mount (use your own assigned head mount), or Clip mount etc. |
* Place camera on mount - either head mount (use your own assigned head mount), or Clip mount etc. |
||
| Line 48: | Line 50: | ||
|[[File:GoPro Hero8 Black - Enable preview 3 - join wifi network IMG 2770.jpg|300x300px]] |
|[[File:GoPro Hero8 Black - Enable preview 3 - join wifi network IMG 2770.jpg|300x300px]] |
||
|[[File:GoPro Hero8 Black - Enable preview 4 - live view IMG 2763.png|300x300px]] |
|[[File:GoPro Hero8 Black - Enable preview 4 - live view IMG 2763.png|300x300px]] |
||
''<small>Head-mounted camera is often aimed high at first.</small>'' |
|||
|} |
|} |
||
* Choose Video Mode and "Standard" preset |
* Choose Video Mode and "Standard" preset |
||
** The "standard" preset is set for training purposes (reduced field of view, high resolution, reduced motion correction) |
** The "standard" preset is set for training purposes (reduced field of view, high resolution, reduced motion correction) |
||
::{| class="wikitable" |
::{| class="wikitable" |
||
|Choose Video mode - 2nd from left.[[File:GoPro Hero8 Black - Choose video - IMG 2771.jpg|300x300px]] |
|''<small>Choose Video mode - 2nd from left.</small>''[[File:GoPro Hero8 Black - Choose video - IMG 2771.jpg|300x300px]] |
||
|Use "Standard" settings.[[File:GoPro Hero8 Black - Presets 1 - IMG 2765.jpg|300x300px]] |
|''<small>Use "Standard" settings.</small>''[[File:GoPro Hero8 Black - Presets 1 - IMG 2765.jpg|300x300px]] |
||
|Settings menu options.[[File:GoPro Hero8 Black - Presets 2 - various IMG 2767.jpg|300x300px]] |
|''<small>Settings menu options.</small>''[[File:GoPro Hero8 Black - Presets 2 - various IMG 2767.jpg|300x300px]] |
||
|"Standard" settings for NanoFab trainings (Initial version, as of 2020-07-01 Demis) |
|''<small>"Standard" settings for NanoFab trainings (Initial version, as of 2020-07-01 Demis).</small>'' |
||
''<small>Have been slightly updated compared to pic, 2020-10.</small>'' |
|||
[[File:GoPro Hero8 Black - Presets 3 - settings IMG 2768.png|300x300px]] |
[[File:GoPro Hero8 Black - Presets 3 - settings IMG 2768.png|300x300px]] |
||
|} |
|} |
||
* Adjust camera angle using Live Preview on smartphone: |
* Adjust camera angle using Live Preview on smartphone: |
||
** Look naturally at some object, and make sure the SmartPhone's preview is showing the same object centered in the screen. |
** Look naturally at some object, and make sure the SmartPhone's preview is showing the same object centered in the screen. |
||
** Typically the camera is angled '''too high'''. |
** Typically the camera is angled '''too high''' by ~30-40°. |
||
** Adjust the camera's angle on the your mount, so that what you look at is centered on the screen, then tighten. (Same as done outside the lab.) |
** Adjust the camera's angle on the your mount, so that what you look at is centered on the screen, then tighten. (Same as done outside the lab.) |
||
* Start/stop the video recording with the Circle button on the SmartPhone app. |
* Start/stop the video recording with the Circle button on the SmartPhone app. |
||
: [[File:GoPro Hero8 Black - Video record button - IMG 2764.png|none|thumb|300x300px|Press the Circle button to start/stop recording.]] |
: [[File:GoPro Hero8 Black - Video record button - IMG 2764.png|none|thumb|300x300px|''Press the Circle button to start/stop recording.'']] |
||
:* You can always stop the recording and restart, with the intention of piecing the recording together at the end. However, it is much less effort to only do a single take and fix mistakes during the recording, as you can spend a lot of time on video editing. |
:* You can always stop the recording and restart, with the intention of piecing the recording together at the end. However, it is much less effort to only do a single take and fix mistakes during the recording, as you can spend a lot of time on video editing. |
||
* You can look at saved videos through the smartphone app, to check your recording, in the '''My Media''' section of the GoPro App. It may require you to download the video to your smartphone, which can take a while. Sometimes it shows a lower-quality version just to avoid downloading - don't worry, the "full" version will usually look and sound much better. |
* You can look at saved videos through the smartphone app, to check your recording, in the '''My Media''' section of the GoPro App. It may require you to download the video to your smartphone, which can take a while. Sometimes it shows a lower-quality version just to avoid downloading - don't worry, the "full" version will usually look and sound much better. |
||
** This is where '''headphones''' in the lab are very helpful, so you can hear the audio of your recordings. |
** This is where '''headphones''' in the lab are very helpful, so you can hear the audio of your recordings. |
||
= |
== Saving the Video to your computer == |
||
Edits are best performed on the GoPro smartphone app, outside the lab. |
|||
''(Untested. I recommend avoiding video editing as much as possible - please add instructions you think will be useful here. --Demis 2020-07-04)'' |
|||
= Saving the Video to your computer = |
|||
There are two ways to save the video. I prefer to plug the GoPro into a laptop/desktop computer (good for posting to Wiki and online trainings via web-meeting). You can also save it to your smartphone wirelessly, but this appears to be more complex for our purposes (good for social media). |
There are two ways to save the video. I prefer to plug the GoPro into a laptop/desktop computer (good for posting to Wiki and online trainings via web-meeting). You can also save it to your smartphone wirelessly, but this appears to be more complex for our purposes (good for social media). |
||
# Outside the lab, at your desktop/laptop computer: |
# Outside the lab, at your desktop/laptop computer: |
||
| Line 80: | Line 79: | ||
# Turn on the GoPro Camera by holding down the power button on the Side. |
# Turn on the GoPro Camera by holding down the power button on the Side. |
||
# On a '''Mac:''' ''(approximate instructions, not exact)'' |
# On a '''Mac:''' ''(approximate instructions, not exact)'' |
||
## |
## Launch '''Applications / Image Capture.app''' |
||
## Select the GoPro camera in the sidebar - you will see all the recorded videos and photos. |
## Select the GoPro camera in the sidebar - you will see all the recorded videos and photos. |
||
## Choose a folder to Download into on the bottom of the screen |
## Choose a folder to Download into on the bottom of the screen |
||
| Line 86: | Line 85: | ||
## Click "Download Selected" or "Download All" and wait for it to complete, it can take some time. |
## Click "Download Selected" or "Download All" and wait for it to complete, it can take some time. |
||
### The files will be downloaded to the specified folder. |
### The files will be downloaded to the specified folder. |
||
## Use the Delete button [[File:GoPro HERO8 Black Instructions - Mac save to computer 2.png]] to delete selected files from the GoPro memory card. You can select multiple files with the Shift or Command keys. |
|||
# On '''Windows:''' |
|||
# On '''Windows:''' ''(approximate instructions, not exact)'' |
|||
## '''''To Be Added''''' |
|||
## Open '''My Computer > HERO8 BLACK''' |
|||
## Copy the files from the HERO8 drive to the desired destination folder |
|||
##Delete files from the GoPro memory card with ''Shift+Delete'' ([[File:Forward Delete Button.png|30x30px]] aka. Forward-Delete) |
|||
== Editing Video == |
|||
GoPro video is always split up into sections of about 15min each, automatically on the camera. This is not changeable on the Gopro. |
|||
* Use the free software [https://www.openshot.org OpenShot] to stitch your videos together. |
|||
* Just drag your files into the timeline in order. You can use the Creation date of the files to figure out the correct order. |
|||
* GoPro's File naming convention: |
|||
** The '''first''' digit is the number in the sequence |
|||
** The '''second/last''' digit is the video recording number - this is counter-intuitive. |
|||
** Example - The following sequence would be the <u>first video</u> shot on the GoPro, in order: |
|||
*** GH'''001'''000<u>1</u>.mp4 |
|||
*** GH'''002'''000<u>1</u>.mp4 |
|||
*** GH'''003'''000<u>1</u>.mp4 |
|||
** The Second video shot (<u>underlined</u>) would be the following files: |
|||
*** GH001<u>0002</u>.mp4 |
|||
*** GH002<u>0002</u>.mp4 |
|||
*** GH003<u>0002</u>.mp4 |
|||
** |
|||
* Export as : |
|||
** Target: MP4 |
|||
** Profile: HD 720p: 30fps (1280x720) |
|||
** Quality: High |
|||
This takes ~30min to stitch a ~1hr video. |
|||
Now you have a single file of the GoPro recording. |
|||
= Uploading |
== Uploading your Videos == |
||
* See [[Video Training: Uploading to GauchoCast/Panopto (Internal)]] |
|||
On your Tool's Wiki page, add a Heading section for training videos, and add links to those videos, similar to uploading PDF files (see the [[Editing Tutorials#Linking to a PDF or other file|Editing Tutorials section on this]]). |
|||
'''Note''' - we may have issues with upload limits on file sizes of file types. We may need to host a separate site just for uploading these videos. Demis will check with Johann on this, the Wiki method is probabaly too annoying for hosting these. |
|||
= Trainings via Webmeeting (Zoom) = |
== Trainings via Webmeeting (Zoom) == |
||
* See [[Video Training: Hosting with Zoom and GacuhoCast/Panopto]] |
|||
* Schedule a Zoom meeting at [https://ucsb.zoom.us ucsb.zoom.com] - use your UCSB NetID credentials. |
|||
** <<Insert steps here, initial guess below>> |
|||
* Recommend that Lab Users/Attendees use a desktop/laptop computer to join, not just phone. They will need to see details on the screen and possibly take notes. |
|||
* Require all attendees to have video ON during the entire training. |
|||
** This verifies that all participants are present and paying attention - local school/college teachers found this was necessary! |
|||
* Use the Zoom > Participants > "'''Mute All'''" button |
|||
** Let users know they can unmute themselves whenever needed, to ask questions |
|||
* Share your computer Screen: |
|||
** Hide or Close all your other programs or apps open on your computer. |
|||
** On the Zoom Toolbar, click the "'''Share Screen [↑]''' " button |
|||
** Enable the "'''Optimize for Video Clip'''" and "'''Share Computer Sound'''" checkboxes |
|||
** Select "'''Desktop 1'''" |
|||
*** This ensures users can see your mouse moving, instead of selecting only one window. |
|||
** Click the "'''Share'''" button to start presenting your computer screen live. |
|||
* Load the pre-recorded video, Maximize the window size, and play/pause as needed. |
|||
** Use a player that allows you to zoom in on details, such as text on the tool's computer screen/software etc. |
|||
*** On '''Mac''': Demis found that the default Quicktime Player does NOT let you zoom in closer than full-screen! |
|||
*** On '''Windows''': '''''To be added''''' |
|||
Latest revision as of 06:15, 13 January 2021

Use this camera with various mounts, to record training videos for your tools. It records spoken audio very well, automatically canceling much of the background noise.
You can edit the videos after the fact, but it's not required - a "good enough" video even with mistakes or corrections would be fine.
We recommend doing online Zoom trainings, during which you screenshare and pull up the recorded video(s), which allows you to play/pause/zoom in on certain parts of the video as needed, and pause to answer user questions.
These is an initial draft of instructions - please feel free to edit! -- Demis 2020-07-02
This procedure uses our GoPro Black 8, and a headstrap to wear it while recording.
Procedure for recording
Outside the lab, before your training
- Fully charge your smartphone
- GoPro 2 spare batteries - make sure both are charged.
- We have a 2-battery charger for keeping the spares fully charged
- Note that the GoPro USB cable is a high-quality (high data rate) USB-C/USB-A cable - cheaper versions usually don't work, so don't lose this cable!
- Download smartphone app called "GoPro" by the company "GoPro, Inc." to your own smartphone.

The "real" GoPro App in the Apple App Store. Beware of cheap imitations. - Turn on the GoPro camera (hold down power button on the side)
- Connect your GoPro smartphone app to the camera (requires Bluetooth and WiFi enabled).
- Instructions for this can be found on the GoPro website here, also copy/pasted below.
- Pick up your camera:
- Power on your camera.
- Open the utility drawer by swiping from the top to the bottom of the touch display, then select "Preferences."
- Select "Connections" and then tap on "Connect Device."
- Tap on "GoPro App" to put your camera in pairing mode.
- Optional: At this point, you can tap on the "i" icon in the top right corner to see your WiFi name and password.
- Open the GoPro App on your SmartPhone:
- Select the Camera logo at the bottom left corner of the app and it will automatically begin scanning for your camera
- You should see "We Found Your GoPro" and a blue "Connect" button. Tap on Connect.
- Optional: You will see a section to change your camera's name, or you can tap on the bottom button to leave the name as it is.
- Once a name is set your GoPro App will show a live preview of your camera. You're all set!
- Pick up your camera:
- Instructions for this can be found on the GoPro website here, also copy/pasted below.
- Wear headphones for your smartphone (wireless is great, but wired is also ok).
- This helps with checking to see if a video sounds/looks ok.
- Put the GoPro on your head mount, and launch the GoPro phone app and "enable live preview".
- Detailed Instructions for Live Preview are below.
- Adjust the angle of the camera so the preview shows what you’re looking at. You want to be "naturally" looking at something, and make sure the GoPro shows the same thing.
- Usually the headmount will aim high - looking above what your eyes are looking at, so adjust it to point down, typically ~30-40° downwards.
In the Lab: Recording your video
- (optional) Bring wired or bluetooth headphones that you can use with your smartphone - this is only for listening to video while in the lab. The "live" audio will be from the GoPro's built-in Mic - it works fine in the lab.
- Turn on camera - hold down the power button on the side.
- Place camera on mount - either head mount (use your own assigned head mount), or Clip mount etc.
- On GoPro smartphone app:
- Enable Live Preview to view the video from the SmartPhone App.
- Choose Video Mode and "Standard" preset
- The "standard" preset is set for training purposes (reduced field of view, high resolution, reduced motion correction)
- Adjust camera angle using Live Preview on smartphone:
- Look naturally at some object, and make sure the SmartPhone's preview is showing the same object centered in the screen.
- Typically the camera is angled too high by ~30-40°.
- Adjust the camera's angle on the your mount, so that what you look at is centered on the screen, then tighten. (Same as done outside the lab.)
- Start/stop the video recording with the Circle button on the SmartPhone app.

Press the Circle button to start/stop recording. - You can always stop the recording and restart, with the intention of piecing the recording together at the end. However, it is much less effort to only do a single take and fix mistakes during the recording, as you can spend a lot of time on video editing.
- You can look at saved videos through the smartphone app, to check your recording, in the My Media section of the GoPro App. It may require you to download the video to your smartphone, which can take a while. Sometimes it shows a lower-quality version just to avoid downloading - don't worry, the "full" version will usually look and sound much better.
- This is where headphones in the lab are very helpful, so you can hear the audio of your recordings.
Saving the Video to your computer
There are two ways to save the video. I prefer to plug the GoPro into a laptop/desktop computer (good for posting to Wiki and online trainings via web-meeting). You can also save it to your smartphone wirelessly, but this appears to be more complex for our purposes (good for social media).
- Outside the lab, at your desktop/laptop computer:
- Plug the GoPro camera into your computer using the supplied USB-A to USB-C cable.
- This is a high-data rate cable - cheaper versions are known to not work properly, so don't lose this!
- Turn on the GoPro Camera by holding down the power button on the Side.
- On a Mac: (approximate instructions, not exact)
- Launch Applications / Image Capture.app
- Select the GoPro camera in the sidebar - you will see all the recorded videos and photos.
- Choose a folder to Download into on the bottom of the screen
- Select the media to download (use Shift or ⌘ to select multiple items)
- Click "Download Selected" or "Download All" and wait for it to complete, it can take some time.
- The files will be downloaded to the specified folder.
- Use the Delete button
to delete selected files from the GoPro memory card. You can select multiple files with the Shift or Command keys.
- On Windows: (approximate instructions, not exact)
Editing Video
GoPro video is always split up into sections of about 15min each, automatically on the camera. This is not changeable on the Gopro.
- Use the free software OpenShot to stitch your videos together.
- Just drag your files into the timeline in order. You can use the Creation date of the files to figure out the correct order.
- GoPro's File naming convention:
- The first digit is the number in the sequence
- The second/last digit is the video recording number - this is counter-intuitive.
- Example - The following sequence would be the first video shot on the GoPro, in order:
- GH0010001.mp4
- GH0020001.mp4
- GH0030001.mp4
- The Second video shot (underlined) would be the following files:
- GH0010002.mp4
- GH0020002.mp4
- GH0030002.mp4
- Export as :
- Target: MP4
- Profile: HD 720p: 30fps (1280x720)
- Quality: High
This takes ~30min to stitch a ~1hr video.
Now you have a single file of the GoPro recording.