{{tool|{{PAGENAME}}
{{tool2|{{PAGENAME}}
|picture=IMG_2416_1.jpg
|picture=IMG_2416_1.jpg
|type = Dry Etch
|type = Dry Etch
|super= Mike Silva
|super= Bill Millerski
|super2= Mike Silva
|phone=(805)839-3918x219
|phone=(805)839-3918x219
|location=Bay 2
|location=Bay 2
Line 17: Line 18:
*[[media:SPTS-Primaxx uEtch Presentation-a.pdf|System Manual Part A]]
*[[media:SPTS-Primaxx uEtch Presentation-a.pdf|System Manual Part A]]
*[[media:SPTS-Primaxx uEtch Presentation-b.pdf|System Manual Part B]]
*[[media:SPTS-Primaxx uEtch Presentation-b.pdf|System Manual Part B]]
*https://www.nanotech.ucsb.edu/wiki/images/a/a3/Operating_procedure.pdf
*https://www.nanotech.ucsb.edu/wiki/images/a/a1/Process_Notes_for_Users.pdf


=Recipes=
=Recipes=
* See the [https://www.nanotech.ucsb.edu/wiki/index.php/Other_Dry_Etching_Recipes#Vapor_HF_Etch_.28uETCH.29 Vapor HF Recipes] page for recipe specific to this tool.
* See the [https://wiki.nanotech.ucsb.edu/w/index.php?title=Other_Dry_Etching_Recipes#Vapor_HF_Etch_.28uETCH.29 Vapor HF Recipes] page for recipe specific to this tool.
* See the general [[Dry Etching Recipes]] page for a table of all etch recipes across all tools.
* See the general [[Dry Etching Recipes]] page for a table of all etch recipes across all tools.

Latest revision as of 17:53, 30 August 2022

Vapor HF Etch
Location Bay 2
Tool Type Dry Etch
Manufacturer SPTS Inc
Description Vapor HF Etcher

Primary Supervisor Bill Millerski
(805) 893-2655
wmillerski@ucsb.edu

Secondary Supervisor

Mike Silva


Recipes Dry Etch Recipes

SignupMonkey: Sign up for this tool


About

The applications of this tool are mainly in MEMS-device fabrication areas (releasing a MEMS structure by etching a sacrificial SiO2 layer below) with the use of Al2O3, Al or some other metal as an etch mask at 45oC. The tool uses vapor HF (VHF), EtOH (Ethanol vapor is an Alcohol-based one, ionizing the HF and activating etching, influencing within wafer etch uniformity, and being most compatible with VHF), and N2 gases and can process small sample(s) (on a 8" Si carrier wafer) up to an 8" wafer. There are 5 standard etch recipes installed in the tool with the SiO2 undercut-etch-rate from low to high. The SiO2 undercut-etch-rate is from ~10nm/min to ~350nm/min.

Documentation

Recipes