*Instructions+Procedures can be found in ''gDrive > Facilities Group > Computer Systems''
*Instructions+Procedures can be found in ''GDrive Share Drive [https://drive.google.com/drive/u/0/folders/0AAqKJ7erJXTnUk9PVA NanoFab IT]''
*'''Unifi Network SDN'''
*#Network Hardware Maintenance
*##Add/Remover User for Unifi Network Controller
*#Switch Maintenance
*##Restart
*##Reset
*#Add/Replace new Switch visit [https://store.ui.com/us/en store.ui.com/us/en] we are using follow switch below
*##switching-standard 48/24/16 ports
*##switching-aggregation 8 Ports
*##Flex Mini 5 Ports
*#Add/ Replace Fail SFP Receiver When searching in the Maintenance Shop, locate the bin labeled SFP Receiver & look for 1000 BASE-LX 1310-nm SFP Receiver
*#Add/ Replace Fail Fiber Cable When searching in the Maintenance Shop, locate the bin labeled Fiber LC to SC and search for the Optical Fiber Patch Cable.
*#Add/Replace the Ethernet patch We have four length of the patch cable 3/5/10/15 ft located in the Tel/Data RM#1117 In both case please update the [https://docs.google.com/spreadsheets/d/1iPc4Sxh8ge2mc0hhXlqS6ofckT8nzfrw9QcWefoLMa8/edit?usp=sharing IT Hardware Log] Sheet: '''Eth Ports''', '''Endpoints'''
*##Patch Pannel to Switch Label format : <<sw-name>>-<<port-number>>
*##System to Wall Port Lable format : Nanofile-Network 10.1.1.1/16
*'''Synology'''
*#Active Backup for Business
*##Add new device
*##Add new server
*##Restore a device
*#Create a new Network Share Folder
*#Add a Device to Apple Time Machine
*#Server Maintenance
*'''Nanofiles'''
*#Failover (CARP)
*#Restart
*#Restore
*#[[Nanofab-IT - Add Device to Network|Add Device to Network]]
*#Nanofile Sync
*##Add a new Device
*###Make sure Device is connected to Nanofiles
*###Connect the Network drive \\nanofiles\staff
*###Copy '''grsync''' directory from the network and paste it to '''c:\''' drive
*###Run the '''Init.bat''' in the grsync directory, press enter twice (make sure do not enter any password) besides remember the part of the stored SSH key
*###open the sync.bat in notepad change
*####'''<code>SET MACHINE=[host-name]</code>'''
*####create a nanofiles - userdata directory in public folder Note : In case of Drive change use this syntax '''<code>/cygdrive/[drive-letter]/</code>'''
*##Replace a Device
*#Generating New WireGard VPN Credentials
*##Server-Side
*###Commend for generating the keys: <code>cd /etc/wiregard</code> <code>wg genkey | tee privatekey_<<replace it with username>> | wg pubkey > publickey_<<replace it with username>></code>
*###Add a new line in /etc/hostname.wg0: <code>wgpeer <<public_key_of_new_user>> wgaip 10.1.10.XXX/32</code>
*###Service Restart: <code>sh /etc/netstart wg0</code>
*##Client-Side
*###'''Generate the a new file with .conf extension''' <code>[Interface]</code> <code>PrivateKey = <<privatekey_of_new_user>></code> <code>Address = 10.1.10.XXX/32</code> <code>DNS = 10.1.1.1</code> <code>[Peer]</code> <code>PublicKey = hHngYmJZUxRfLAmCxhC00m80hjsNDKl4LKV4iDYN+TY=  </code> <code>AllowedIPs = 10.1.0.0/16</code> <code>Endpoint = nanofiles1.ece.ucsb.edu:5900</code> <code>PersistentKeepalive = 25</code>


*'''Signupmonkey'''
*'''Signupmonkey'''
Line 75: Line 29:
**Restart
**Restart
**Restore
**Restore
*'''DataGrove'''
**Restore Backup
**#Login to nanofiles2
**#Get the list of the Snapshots: <code>restic -p /etc/restic-pwd --repo sftp:restic@datagrove:/srv/backup snapshots</code>
**#To view files within a snapshot: <code>restic -p /etc/restic-pwd --repo sftp:restic@datagrove:/srv/backup ls -l [snapshort-id] | grep "[dir-path-to-search]"</code>
**#To restore a single directory: <code>restic -p /etc/restic-pwd --repo sftp:restic@datagrove:/srv/backup restore [snapshort-id] --target [dir-path-save-restore-data] --include [dir-path-to-restore]</code>
**Note: Please replace all value in [square-bracket] as mention
*'''NanoFab Wiki'''
*'''NanoFab Wiki'''
**Restart
**Restart
**Restore
**Restore
*'''NanoFab Server UPS'''
*'''NanoFab Server UPS'''
**Battery Test
**Battery Test<br />
*'''Utilities Software'''
*#LogMeIn
*##Add a new Device
*##Add a new user
*##Remove a External/Internal User <br />


==Administration==
==Administration==

Revision as of 23:10, 9 April 2024

This page is intended for NanoFab Staff, internal.

Equipment Group

Process Group

NanoFab IT

Computers, Networks, FTP/File-Sync etc.

  • Instructions+Procedures can be found in GDrive Share Drive NanoFab IT
  • Signupmonkey
    • Failover
    • Restart
    • Restore
  • RechargeApp
    • Failover
    • Restart
    • Restore
  • Nanofabserver2
    • Restart
    • Restore
  • NanoFab Wiki
    • Restart
    • Restore
  • NanoFab Server UPS
    • Battery Test

Administration

Useful UCSB Pages

  • Facilities Work Requests - Here's where you report facilities repair requests, like replacing light bulbs, building problems (doors, elevators) etc.

Old / Defunct

Old pages we don't use on the Wiki anymore, but are kept for possible utility later on.