Automated Coat/Develop System (S-Cubed Flexi): Difference between revisions
Jump to navigation
Jump to search
(link to recipes table) |
(→Detailed Specifications: linked to PR's,) |
||
(2 intermediate revisions by the same user not shown) | |||
Line 12: | Line 12: | ||
|toolid=67 |
|toolid=67 |
||
}} |
}} |
||
''This Tool is now available for training - please contact the supervisor. 2022-11-01'' |
''This Tool is now available for training - please contact the [[Tony Bosch|supervisor]]. 2022-11-01'' |
||
==About== |
==About== |
||
Line 18: | Line 18: | ||
The S3-Coater is a Coater/Developer system that has one photoresist spinner, one developer spinner and 4 hotplates each with independent temperature control and a chill plate. A central robot picks your wafer/s from one of 2 cassettes, processes them and returns them to the cassette. The system is recipe driven with a high degree of process control and minimal backside contamination, and coats photoresists with low particle counts/streaks and high uniformity. |
The S3-Coater is a Coater/Developer system that has one photoresist spinner, one developer spinner and 4 hotplates each with independent temperature control and a chill plate. A central robot picks your wafer/s from one of 2 cassettes, processes them and returns them to the cassette. The system is recipe driven with a high degree of process control and minimal backside contamination, and coats photoresists with low particle counts/streaks and high uniformity. |
||
Only full size 4-inch (100mm) substrates are allowed on this system. |
|||
==Detailed Specifications== |
==Detailed Specifications== |
||
*Wafer Size: 100mm |
*Wafer Size: 100mm |
||
*PR Coating Properties: |
*PR Coating Properties: |
||
**Uniformity < 1.0% |
**Uniformity < 1.0% |
||
**< 100 particles on 100mm wafer |
**< 100 particles on 100mm wafer |
||
*Photoresists/Underlayers Available: |
*Photoresists/Underlayers Available: |
||
**[https://wiki.nanofab.ucsb.edu/w/images/3/38/UV6-Positive-Resist-Datasheet.pdf UV6-0.8] - DUV Positive imaging resist |
|||
**UV6-0.8 |
|||
**[[Stepper Recipes#DS-K101-304|DS-K101-304]] - DUV bottom anti-reflection layer (BARC). |
|||
**DS-K101-304 |
|||
**PMMA - '''<u>NOT FOR PUBLIC USE AT THIS TIME</u>''' |
**PMMA - '''<u>NOT FOR PUBLIC USE AT THIS TIME</u>''' |
||
**PMGI SF11 - '''<u>NOT FOR |
**PMGI SF11 - '''<u>NOT FOR PUBLIC USE AT THIS TIME</u>''' |
||
**PMGI SF5 - '''<u>NOT FOR |
**PMGI SF5 - '''<u>NOT FOR PUBLIC USE AT THIS TIME</u>''' |
||
*Solvents Available: |
*Solvents Available: |
||
**EBR100 (wafer backside cleaning) |
**EBR100 (wafer backside cleaning) |
||
*Developers Available: |
*Developers Available: |
||
**[https://wiki.nanofab.ucsb.edu/w/images/f/f0/AZ300MIF-Developer-Datasheet.pdf AZ 300 MiF] - ''now available to use! (2024-07)'' |
|||
**AZ 300 MiF - '''<u>NOT FOR GENERAL USE AT THIS TIME</u>''' |
|||
*Hotplates Available: |
|||
**135°C - for UV6 soft-bake and Post-Exposure Bake |
|||
**220°C - for DSK101 BARC soft-bake - dry etchable |
|||
**185*C - for DSK101 BARC soft-bake - developable for undercut |
|||
==Process Information== |
==Process Information== |
||
Line 44: | Line 48: | ||
==Operating Procedures== |
==Operating Procedures== |
||
*[[S-Cubed Flexi - Operating Procedure|Standard Operating Procedure]] - For running pre-written recipes only. |
|||
== |
==Recipes== |
||
'''Recipes > Lithography >''' [[Lithography Recipes#Automated Coat.2FDevelop System Recipes .28S-Cubed Flexi.29|'''<u>Automated Coater Recipes</u>''']] - See all available spin-coat recipes for this machine. Only Staff may edit/create recipes. |
*'''Recipes > Lithography >''' [[Lithography Recipes#Automated Coat.2FDevelop System Recipes .28S-Cubed Flexi.29|'''<u>Automated Coater Recipes</u>''']] - See all available spin-coat recipes for this machine. Only Staff may edit/create recipes. |
Latest revision as of 18:03, 3 September 2024
|
This Tool is now available for training - please contact the supervisor. 2022-11-01
About
The S3-Coater is a Coater/Developer system that has one photoresist spinner, one developer spinner and 4 hotplates each with independent temperature control and a chill plate. A central robot picks your wafer/s from one of 2 cassettes, processes them and returns them to the cassette. The system is recipe driven with a high degree of process control and minimal backside contamination, and coats photoresists with low particle counts/streaks and high uniformity.
Only full size 4-inch (100mm) substrates are allowed on this system.
Detailed Specifications
- Wafer Size: 100mm
- PR Coating Properties:
- Uniformity < 1.0%
- < 100 particles on 100mm wafer
- Photoresists/Underlayers Available:
- UV6-0.8 - DUV Positive imaging resist
- DS-K101-304 - DUV bottom anti-reflection layer (BARC).
- PMMA - NOT FOR PUBLIC USE AT THIS TIME
- PMGI SF11 - NOT FOR PUBLIC USE AT THIS TIME
- PMGI SF5 - NOT FOR PUBLIC USE AT THIS TIME
- Solvents Available:
- EBR100 (wafer backside cleaning)
- Developers Available:
- AZ 300 MiF - now available to use! (2024-07)
- Hotplates Available:
- 135°C - for UV6 soft-bake and Post-Exposure Bake
- 220°C - for DSK101 BARC soft-bake - dry etchable
- 185*C - for DSK101 BARC soft-bake - developable for undercut
Process Information
- Recipe Page for S-Cubed Coater: Lithography Recipes > Automated Coat/Develop System Recipes (S-Cubed Flexi)
- See the Photolith. Chemicals page for info on the installed resists.
Operating Procedures
- Standard Operating Procedure - For running pre-written recipes only.
Recipes
- Recipes > Lithography > Automated Coater Recipes - See all available spin-coat recipes for this machine. Only Staff may edit/create recipes.