=====ECVD#2 will remain down overnight=====
=====PECVD#2 will remain down overnight=====
Unfortunately PECVD2 will remain down overnight.
Unfortunately PECVD2 will remain down overnight.


Line 9: Line 9:
I am cooling down the chamber overnight and we will look into the heater coil in the morning.
I am cooling down the chamber overnight and we will look into the heater coil in the morning.
//[[User:Mehalana v|Vraj Mehalana]] 03:31, 25 February 2025 (UTC)
//[[User:Mehalana v|Vraj Mehalana]] 03:31, 25 February 2025 (UTC)

=====RIE #5 Down=====
=====RIE #5 Down=====
RIE #5 will be down Monday March 13th through the end of Wednesday March 15th for maintenance.
RIE #5 will be down Monday March 13th through the end of Wednesday March 15th for maintenance.

Revision as of 03:31, 25 February 2025

PECVD#2 will remain down overnight

Unfortunately PECVD2 will remain down overnight.

The heater is unable to keep up with the setpoint while running.

Don and I replaced the heater controller without luck.

I am cooling down the chamber overnight and we will look into the heater coil in the morning. //Vraj Mehalana 03:31, 25 February 2025 (UTC)

RIE #5 Down

RIE #5 will be down Monday March 13th through the end of Wednesday March 15th for maintenance.

If we complete the job early we will send a follow-up email releasing the system.

//Vraj Mehalana 09:46, 21 February 2025 (UTC)

Olympus DSX Microscope: Down

After speaking with Olympus it looks like there is a problem with the polarizer that is interfering with basic system initialization. I'm waiting for the repair quote and will update everyone when we know more. -- Tony Bosch // Demis D. John 20:41, 5 February 2025 (UTC)

Stepper #3 (ASML DUV) - Maint moved to March 3rd

We have postponed the Periodic Maintenance (PM) to the week of Monday March 3rd. Please plan your work accordingly. // Demis D. John 19:44, 4 February 2025 (UTC)

Oxford ALD+Ion Mill: UP

The tool now runs all process temperatures (120-300c). --Bill Millerski UCSB //Demis D. John 19:48, 4 February 2025 (UTC)

New Gowns: Toolbelts purchases

We are required to switch to new gowns in January. The new gowns won’t have pockets, but you are allowed to purchase cleanroom tool belts. Please ask staff for which tool belts you can purchase.

Two vendors for cleanroom belts we are using are listed here, you may request others:

// Demis D. John 03:34, 3 January 2025 (UTC)

Suss SB6-8E

We found a blown resistor (and a questionable op amp) on one of the boards that contains the z-axis motor circuit. However, we still cannot get the tool to initialize. Next we will try swapping out the hard drive again and run some more tests.

I will send out an update once we have one. -Aidan // Demis D. John 00:35, 8 December 2024 (UTC)

ICP1 Down

The board we were waiting on arrived, but it did not resolve the tool issue. We are working with Panasonic on the next steps. //Vraj Mehalana 14:17, 1 March 2024 (PST)