Automated Coat/Develop System (S-Cubed Flexi): Difference between revisions

From UCSB Nanofab Wiki
Jump to navigation Jump to search
Content deleted Content added
added notice abotu staff use only
Detailed Specifications: removed "new" labels
 
(17 intermediate revisions by 4 users not shown)
Line 1: Line 1:
{{tool|{{PAGENAME}}
{{tool2|{{PAGENAME}}
|picture=TBD.jpg
|picture=TBD.jpg
|type = Lithography
|super= Tony Bosch
|super= Tony Bosch
|super2= Lee Sawyer
|location=Bay 7
|location=Bay 7
|description = Automatic Coat/Bake/Develop
|description = Automatic Coat/Bake/Develop
|manufacturer = S-Cubed
|manufacturer = [https://www.s-cubed.com S-Cubed]
|model = Flexi (Custom)
|ToolType = Wet Processing
|type = Wet Processing
|recipe = Lithography
|recipe = Lithography
|materials =
|materials =
|toolid=
|toolid=67
}}
}}
{{ToolActions
'''This tool is only available for Staff use at this time.'''
|toolid = 67
|ProcessControlURL =
|InstructionsURL = https://wiki.nanofab.ucsb.edu/wiki/Automated_Coat/Develop_System_(S-Cubed_Flexi)#Operating_Procedures
|TrainingURL =
}}
==About==


The S3-Coater is a Coater/Developer system that has one photoresist spinner, one developer spinner and 4 hotplates each with independent temperature control and a chill plate. A central robot picks your wafer/s from one of 2 cassettes, processes them and returns them to the cassette. The system is recipe driven with a high degree of process control and minimal backside contamination, and coats photoresists with low particle counts/streaks and high uniformity.
=About=


Only full size 4-inch (100mm) substrates are allowed on this system.
''To Be Added''


=Detailed Specifications=
==Detailed Specifications==


*Wafer Size: 100mm (150mm possible but not set up)
*Wafer Size: 100mm
*PR Coating Properties:
*PR Coating Properties:
**Uniformity < 1.0%
**Uniformity < 1.0%
**< 100 particles on 100mm wafer
**< 100 particles on 100mm wafer
*Photoresists/Underlayers Available:
*Photoresists/Underlayers Available:
**[https://wiki.nanofab.ucsb.edu/w/images/3/38/UV6-Positive-Resist-Datasheet.pdf UV6-0.8] - DUV Positive imaging resist
**UV6-0.8
**[[Stepper Recipes#DS-K101-304|DS-K101-304]] - DUV bottom anti-reflection layer (BARC).
**DS-K101-304
**PMMA - '''NOT FOR PUBLIC USE AT THIS TIME'''
**PMMA
**PMGI SF11
**PMGI SF11 - '''NOT FOR PUBLIC USE AT THIS TIME'''
**PMGI SF5 - '''NOT FOR PUBLIC USE AT THIS TIME'''
**PMGI SF5
*Solvents Available:
*Solvents Available:
**EBR100
**EBR100 (wafer backside cleaning)
*Developers Available:
*Developers Available:
**[https://wiki.nanofab.ucsb.edu/w/images/f/f0/AZ300MIF-Developer-Datasheet.pdf AZ 300 MiF]
**AZ 300 MiF
*Hotplates Available:
**135°C - for UV6 soft-bake and Post-Exposure Bake
**220°C - for DSK101 BARC soft-bake - dry etchable
**185*C - for DSK101 BARC soft-bake - developable for undercut


=Process Information=
==Process Information==


*Recipe Page for S-Cubed Coater: [[Lithography Recipes#Automated%20Coat.2FDevelop%20System%20Recipes%20.28S-Cubed%20Flexi.29|Lithography Recipes > Automated Coat/Develop System Recipes (S-Cubed Flexi]])
*Recipe Page for S-Cubed Coater: [[Lithography Recipes#Automated%20Coat.2FDevelop%20System%20Recipes%20.28S-Cubed%20Flexi.29|Lithography Recipes > Automated Coat/Develop System Recipes (S-Cubed Flexi]])
*See the [https://www.nanotech.ucsb.edu/wiki/index.php/Lithography_Recipes#Chemicals_Stocked_.2B_Datasheets Photolith. Chemicals page] for info on the installed resists.
*See the [https://wiki.nanotech.ucsb.edu/w/index.php?title=Lithography_Recipes#Chemicals_Stocked_.2B_Datasheets Photolith. Chemicals page] for info on the installed resists.

==Operating Procedures==

*[[S-Cubed Flexi - Operating Procedure|Standard Operating Procedure]] - For running pre-written recipes only.


==Recipes==
=Operating Procedures=


*'''Recipes > Lithography >''' [[Lithography Recipes#Automated Coat.2FDevelop System Recipes .28S-Cubed Flexi.29|'''<u>Automated Coater Recipes</u>''']] - See all available spin-coat recipes for this machine. Only Staff may edit/create recipes.
*''To Be Added''

Latest revision as of 17:16, 25 June 2026

Automated Coat/Develop System (S-Cubed Flexi)
Location Bay 7
Tool Type Wet Processing
Manufacturer S-Cubed
Model Flexi (Custom)
Description Automatic Coat/Bake/Develop

Primary Supervisor Tony Bosch
(805) 893-3486
bosch@ece.ucsb.edu

Secondary Supervisor

Lee Sawyer


Recipes Wet Processing Recipes

SignupMonkey: Sign up for this tool


Instructions + Procedures

Sign Up

Get Trained

Maintenance
Messages
Report Issue


About

The S3-Coater is a Coater/Developer system that has one photoresist spinner, one developer spinner and 4 hotplates each with independent temperature control and a chill plate. A central robot picks your wafer/s from one of 2 cassettes, processes them and returns them to the cassette. The system is recipe driven with a high degree of process control and minimal backside contamination, and coats photoresists with low particle counts/streaks and high uniformity.

Only full size 4-inch (100mm) substrates are allowed on this system.

Detailed Specifications

  • Wafer Size: 100mm
  • PR Coating Properties:
    • Uniformity < 1.0%
    • < 100 particles on 100mm wafer
  • Photoresists/Underlayers Available:
    • UV6-0.8 - DUV Positive imaging resist
    • DS-K101-304 - DUV bottom anti-reflection layer (BARC).
    • PMMA - NOT FOR PUBLIC USE AT THIS TIME
    • PMGI SF11 - NOT FOR PUBLIC USE AT THIS TIME
    • PMGI SF5 - NOT FOR PUBLIC USE AT THIS TIME
  • Solvents Available:
    • EBR100 (wafer backside cleaning)
  • Developers Available:
  • Hotplates Available:
    • 135°C - for UV6 soft-bake and Post-Exposure Bake
    • 220°C - for DSK101 BARC soft-bake - dry etchable
    • 185*C - for DSK101 BARC soft-bake - developable for undercut

Process Information

Operating Procedures

Recipes

  • Recipes > Lithography > Automated Coater Recipes - See all available spin-coat recipes for this machine. Only Staff may edit/create recipes.