Automated Coat/Develop System (S-Cubed Flexi): Difference between revisions
Jump to navigation
Jump to search
Content deleted Content added
m edit staff use notice |
→Detailed Specifications: removed "new" labels |
||
| (16 intermediate revisions by 4 users not shown) | |||
| Line 1: | Line 1: | ||
{{ |
{{tool2|{{PAGENAME}} |
||
|picture=TBD.jpg |
|picture=TBD.jpg |
||
|type = Lithography |
|||
|super= Tony Bosch |
|super= Tony Bosch |
||
|super2= Lee Sawyer |
|||
|location=Bay 7 |
|location=Bay 7 |
||
|description = Automatic Coat/Bake/Develop |
|description = Automatic Coat/Bake/Develop |
||
|manufacturer = S-Cubed |
|manufacturer = [https://www.s-cubed.com S-Cubed] |
||
|model = Flexi (Custom) |
|||
| |
|type = Wet Processing |
||
|recipe = Lithography |
|recipe = Lithography |
||
|materials = |
|materials = |
||
|toolid= |
|toolid=67 |
||
}} |
}} |
||
{{ToolActions |
|||
| ⚫ | |||
|toolid = 67 |
|||
|ProcessControlURL = |
|||
|InstructionsURL = https://wiki.nanofab.ucsb.edu/wiki/Automated_Coat/Develop_System_(S-Cubed_Flexi)#Operating_Procedures |
|||
|TrainingURL = |
|||
}} |
|||
| ⚫ | |||
The S3-Coater is a Coater/Developer system that has one photoresist spinner, one developer spinner and 4 hotplates each with independent temperature control and a chill plate. A central robot picks your wafer/s from one of 2 cassettes, processes them and returns them to the cassette. The system is recipe driven with a high degree of process control and minimal backside contamination, and coats photoresists with low particle counts/streaks and high uniformity. |
|||
| ⚫ | |||
Only full size 4-inch (100mm) substrates are allowed on this system. |
|||
''To Be Added'' |
|||
=Detailed Specifications= |
==Detailed Specifications== |
||
*Wafer Size: 100mm |
*Wafer Size: 100mm |
||
*PR Coating Properties: |
*PR Coating Properties: |
||
**Uniformity < 1.0% |
**Uniformity < 1.0% |
||
**< 100 particles on 100mm wafer |
**< 100 particles on 100mm wafer |
||
*Photoresists/Underlayers Available: |
*Photoresists/Underlayers Available: |
||
**[https://wiki.nanofab.ucsb.edu/w/images/3/38/UV6-Positive-Resist-Datasheet.pdf UV6-0.8] - DUV Positive imaging resist |
|||
**UV6-0.8 |
|||
**[[Stepper Recipes#DS-K101-304|DS-K101-304]] - DUV bottom anti-reflection layer (BARC). |
|||
**DS-K101-304 |
|||
| ⚫ | |||
**PMMA |
|||
**PMGI SF11 |
**PMGI SF11 - '''NOT FOR PUBLIC USE AT THIS TIME''' |
||
**PMGI SF5 - '''NOT FOR PUBLIC USE AT THIS TIME''' |
|||
**PMGI SF5 |
|||
*Solvents Available: |
*Solvents Available: |
||
**EBR100 |
**EBR100 (wafer backside cleaning) |
||
*Developers Available: |
*Developers Available: |
||
**[https://wiki.nanofab.ucsb.edu/w/images/f/f0/AZ300MIF-Developer-Datasheet.pdf AZ 300 MiF] |
|||
**AZ 300 MiF |
|||
*Hotplates Available: |
|||
**135°C - for UV6 soft-bake and Post-Exposure Bake |
|||
**220°C - for DSK101 BARC soft-bake - dry etchable |
|||
**185*C - for DSK101 BARC soft-bake - developable for undercut |
|||
=Process Information= |
==Process Information== |
||
*Recipe Page for S-Cubed Coater: [[Lithography Recipes#Automated%20Coat.2FDevelop%20System%20Recipes%20.28S-Cubed%20Flexi.29|Lithography Recipes > Automated Coat/Develop System Recipes (S-Cubed Flexi]]) |
*Recipe Page for S-Cubed Coater: [[Lithography Recipes#Automated%20Coat.2FDevelop%20System%20Recipes%20.28S-Cubed%20Flexi.29|Lithography Recipes > Automated Coat/Develop System Recipes (S-Cubed Flexi]]) |
||
*See the [https:// |
*See the [https://wiki.nanotech.ucsb.edu/w/index.php?title=Lithography_Recipes#Chemicals_Stocked_.2B_Datasheets Photolith. Chemicals page] for info on the installed resists. |
||
| ⚫ | |||
*[[S-Cubed Flexi - Operating Procedure|Standard Operating Procedure]] - For running pre-written recipes only. |
|||
==Recipes== |
|||
| ⚫ | |||
*'''Recipes > Lithography >''' [[Lithography Recipes#Automated Coat.2FDevelop System Recipes .28S-Cubed Flexi.29|'''<u>Automated Coater Recipes</u>''']] - See all available spin-coat recipes for this machine. Only Staff may edit/create recipes. |
|||
*''To Be Added'' |
|||
Latest revision as of 17:16, 25 June 2026
| ||||||||||||||||||||||||||||||||
| |
| |
|
| |
| |
|
About
The S3-Coater is a Coater/Developer system that has one photoresist spinner, one developer spinner and 4 hotplates each with independent temperature control and a chill plate. A central robot picks your wafer/s from one of 2 cassettes, processes them and returns them to the cassette. The system is recipe driven with a high degree of process control and minimal backside contamination, and coats photoresists with low particle counts/streaks and high uniformity.
Only full size 4-inch (100mm) substrates are allowed on this system.
Detailed Specifications
- Wafer Size: 100mm
- PR Coating Properties:
- Uniformity < 1.0%
- < 100 particles on 100mm wafer
- Photoresists/Underlayers Available:
- UV6-0.8 - DUV Positive imaging resist
- DS-K101-304 - DUV bottom anti-reflection layer (BARC).
- PMMA - NOT FOR PUBLIC USE AT THIS TIME
- PMGI SF11 - NOT FOR PUBLIC USE AT THIS TIME
- PMGI SF5 - NOT FOR PUBLIC USE AT THIS TIME
- Solvents Available:
- EBR100 (wafer backside cleaning)
- Developers Available:
- Hotplates Available:
- 135°C - for UV6 soft-bake and Post-Exposure Bake
- 220°C - for DSK101 BARC soft-bake - dry etchable
- 185*C - for DSK101 BARC soft-bake - developable for undercut
Process Information
- Recipe Page for S-Cubed Coater: Lithography Recipes > Automated Coat/Develop System Recipes (S-Cubed Flexi)
- See the Photolith. Chemicals page for info on the installed resists.
Operating Procedures
- Standard Operating Procedure - For running pre-written recipes only.
Recipes
- Recipes > Lithography > Automated Coater Recipes - See all available spin-coat recipes for this machine. Only Staff may edit/create recipes.
