Process Group - Process Control Data: Difference between revisions

From UCSB Nanofab Wiki
Jump to navigation Jump to search
Content deleted Content added
Deposition, Metal (Process Control Data): added all eBeam 1 data + plots
 
(15 intermediate revisions by 2 users not shown)
Line 7: Line 7:
Data are collected by our [https://nanofab.ucsb.edu/workforce#internships Process Group Interns] and reviewed by [[Staff List#Process Group|Process Group Staff]].
Data are collected by our [https://nanofab.ucsb.edu/workforce#internships Process Group Interns] and reviewed by [[Staff List#Process Group|Process Group Staff]].
=Deposition, Dielectric (Process Control Data)=
=Deposition, Dielectric (Process Control Data)=
[[File:PECVD SPC Chart Example.png|alt=SPC chart example|thumb|228x228px|Example Process Control Charts (SPC) for thin-film DepCals.]]
[[File:PECVD SPC Chart Example.png|alt=SPC chart example|thumb|228x228px|Example Process Control Charts (SPC) for thin-film DepCals.|link=]]
[[File:Surfscan 230113A7G2 after low particles.jpg|alt=screenshot of surfscan particle count|thumb|205x205px|Example particle counts taken on each tool+film.]]
[[File:Surfscan 230113A7G2 after low particles.jpg|alt=screenshot of surfscan particle count|thumb|205x205px|Example particle counts taken on each tool+film.|link=]]
[[File:PECVD1 SiO2 F50 WaferMap example.jpg|alt=Screenshot of Filmetrics F50 wafermap of typical DepCals film|thumb|215x215px|Example of DepCals Thickness/Refractive Index uniformity measurement (4% shown here).]]
[[File:PECVD1 SiO2 F50 WaferMap example.jpg|alt=Screenshot of Filmetrics F50 wafermap of typical DepCals film|thumb|215x215px|Example of DepCals Thickness/Refractive Index uniformity measurement (4% shown here).|link=]]
''Process Control data for various deposition tools in the lab.''
''Process Control data for various deposition tools in the lab.''


==[[PECVD Recipes#PECVD 1 .28PlasmaTherm 790.29|PECVD #1 (PlasmaTherm 790)]]==
==[[PECVD Recipes#PECVD 1 .28PlasmaTherm 790.29|PECVD #1 (PlasmaTherm 790)]] - Process Control==


*[https://docs.google.com/spreadsheets/d/1fTDNXxpf4tgNYLIEs_jvehG1KvtXqqTRDBI7sHNAVvo/edit#gid=1270764394 PECVD#1: Plots of all data]
*[https://docs.google.com/spreadsheets/d/1fTDNXxpf4tgNYLIEs_jvehG1KvtXqqTRDBI7sHNAVvo/edit#gid=1270764394 PECVD#1: Plots of all data]
Line 18: Line 18:
*[https://docs.google.com/spreadsheets/d/1fTDNXxpf4tgNYLIEs_jvehG1KvtXqqTRDBI7sHNAVvo/edit#gid=98787450 PECVD#1: Si<sub>3</sub>N<sub>4</sub>]
*[https://docs.google.com/spreadsheets/d/1fTDNXxpf4tgNYLIEs_jvehG1KvtXqqTRDBI7sHNAVvo/edit#gid=98787450 PECVD#1: Si<sub>3</sub>N<sub>4</sub>]


==[[PECVD Recipes#PECVD 2 .28Advanced Vacuum.29|PECVD #2 (Advanced Vacuum)]]==
==[[PECVD Recipes#PECVD 2 .28Advanced Vacuum.29|PECVD #2 (Advanced Vacuum)]] - Process Control==


*[https://docs.google.com/spreadsheets/d/1iSW1eAAg824y9PYYLG9aiaw53PEJ-f9ofylpVlCDq9Y/edit#gid=272916741 PECVD#2: Plots of all data]
*[https://docs.google.com/spreadsheets/d/1iSW1eAAg824y9PYYLG9aiaw53PEJ-f9ofylpVlCDq9Y/edit#gid=272916741 PECVD#2: Plots of all data]
Line 26: Line 26:
**[https://docs.google.com/spreadsheets/d/1iSW1eAAg824y9PYYLG9aiaw53PEJ-f9ofylpVlCDq9Y/edit#gid=203400760 Plots of Low-Stress Si<sub>3</sub>N<sub>4</sub> Data]
**[https://docs.google.com/spreadsheets/d/1iSW1eAAg824y9PYYLG9aiaw53PEJ-f9ofylpVlCDq9Y/edit#gid=203400760 Plots of Low-Stress Si<sub>3</sub>N<sub>4</sub> Data]


==[[PECVD Recipes#ICP-PECVD .28Unaxis VLR.29|ICP-PECVD (Unaxis VLR Dep)]]==
==[[PECVD Recipes#ICP-PECVD .28Unaxis VLR.29|ICP-PECVD (Unaxis VLR Dep)]] - Process Control==


*[https://docs.google.com/spreadsheets/d/1CuDMKFTTzGLL6CP-FEI_9cOnUaIw-432ppDFssB59wY/edit#gid=417334948https://docs.google.com/spreadsheets/d/1CuDMKFTTzGLL6CP-FEI_9cOnUaIw-432ppDFssB59wY/edit#gid=417334948 ICP-PECVD: Plots of SiO<sub>2</sub> Films]
*[https://docs.google.com/spreadsheets/d/1CuDMKFTTzGLL6CP-FEI_9cOnUaIw-432ppDFssB59wY/edit#gid=417334948https://docs.google.com/spreadsheets/d/1CuDMKFTTzGLL6CP-FEI_9cOnUaIw-432ppDFssB59wY/edit#gid=417334948 ICP-PECVD: Plots of SiO<sub>2</sub> Films]
Line 35: Line 35:
*[https://docs.google.com/spreadsheets/d/1CuDMKFTTzGLL6CP-FEI_9cOnUaIw-432ppDFssB59wY/edit#gid=1517031044 ICP-PECVD: Si<sub>3</sub>N<sub>4</sub> Low-Stress]
*[https://docs.google.com/spreadsheets/d/1CuDMKFTTzGLL6CP-FEI_9cOnUaIw-432ppDFssB59wY/edit#gid=1517031044 ICP-PECVD: Si<sub>3</sub>N<sub>4</sub> Low-Stress]


==[[Sputtering Recipes#Ion Beam Deposition .28Veeco NEXUS.29|Ion Beam Sputter Deposition (Veeco Nexus)]]==
==[[Sputtering Recipes#Ion Beam Deposition .28Veeco NEXUS.29|Ion Beam Sputter Deposition (Veeco Nexus)]] - Process Control==


*[https://docs.google.com/spreadsheets/d/11A0ac8NU51bmcQ_grQcq9wuPwWnfy1_9MNk2DEo5yyo/edit#gid=2030038046 IBD: Plots of all data]
*[https://docs.google.com/spreadsheets/d/11A0ac8NU51bmcQ_grQcq9wuPwWnfy1_9MNk2DEo5yyo/edit#gid=2030038046 IBD: Plots of all data]
Line 52: Line 52:
<hr style="height:5px">
<hr style="height:5px">
<hr style="height:5px">
<hr style="height:5px">
=Deposition, Metal (Process Control Data)=
=Deposition, Metal - Process Control Data=
''Process Control data for various Metal evaporators in the lab.''
''Process Control data for various deposition tools in the lab.''

== [[Sputter 5 (AJA ATC 2200-V)]] - Process Control ==
[[File:Process Control - Sputter 5 Titanium Sheet Resistance plot.png|alt=Screenshot of Sputter 5 Titanium Sheet Resistance process control chart|thumb|Sputter 5 Titanium - Sheet Resistance - Process Control Chart - '''Example''' data only.

← click a link for live data.|link=]]

=== Sputter 5: Ti ===
*[https://docs.google.com/spreadsheets/d/1HiEBTkZdtZmgdtSs619Tnkn-nbCi8BPW9oZYVybjgt4/edit?gid=695635057#gid=695635057 Titanium Datasheet]
*[https://docs.google.com/spreadsheets/d/1HiEBTkZdtZmgdtSs619Tnkn-nbCi8BPW9oZYVybjgt4/edit?gid=1766775909#gid=1766775909 Titanium Plots]

=== Sputter 5: Al ===
*[https://docs.google.com/spreadsheets/d/1HiEBTkZdtZmgdtSs619Tnkn-nbCi8BPW9oZYVybjgt4/edit?gid=0#gid=0 Aluminum Datasheet]
*[https://docs.google.com/spreadsheets/d/1HiEBTkZdtZmgdtSs619Tnkn-nbCi8BPW9oZYVybjgt4/edit?gid=1766775909#gid=1766775909 Aluminum Plots]

=== Sputter 5: Cr ===
*[https://docs.google.com/spreadsheets/d/1HiEBTkZdtZmgdtSs619Tnkn-nbCi8BPW9oZYVybjgt4/edit?gid=572205583#gid=572205583 Chromium Datasheet]
*[https://docs.google.com/spreadsheets/d/1HiEBTkZdtZmgdtSs619Tnkn-nbCi8BPW9oZYVybjgt4/edit?gid=1766775909#gid=1766775909 Chromium Plots]

== [[E-Beam 4 (CHA)]] - Process Control ==
[[File:Process Control - E-Beam 4 Titanium Stress plot.png|alt=Screenshot of E-Beam 4 Titanium Stress - process control chart|thumb|E-Beam 4 Titanium Stress - Process Control Chart. '''Example''' data only -


← click a link for live data.|link=]]
== [[E-Beam 4 (CHA)]] ==


=== E-Beam 4: Ti ===
=== E-Beam 4: Ti ===
Line 73: Line 93:
*[https://docs.google.com/spreadsheets/d/1W7OFMAlRIcbpjm7FsbCh9ZLCCbhEp0bhtAC7UqEmJ5U/edit?gid=1525197973#gid=1525197973 Nickel Plots]
*[https://docs.google.com/spreadsheets/d/1W7OFMAlRIcbpjm7FsbCh9ZLCCbhEp0bhtAC7UqEmJ5U/edit?gid=1525197973#gid=1525197973 Nickel Plots]


== [[E-Beam 1 (Sharon)]] ==
== [[E-Beam 1 (Sharon)]] - Process Control ==


=== E-Beam 1: Ti ===
=== E-Beam 1: Ti ===
Line 96: Line 116:
''Process Control data for various dry etching tools in the lab.''
''Process Control data for various dry etching tools in the lab.''


==[[ICP Etching Recipes#Process Control Data .28Fluorine ICP Etcher.29|PlasmaTherm SLR Fluorine Etcher]]==
==[[ICP Etching Recipes#Process Control Data .28Fluorine ICP Etcher.29|PlasmaTherm SLR Fluorine Etcher]] - Process Control==


=== SiO<sub>2</sub> Etching (FL-ICP Process Control) ===
=== SiO<sub>2</sub> Etching (FL-ICP Process Control) ===
Line 114: Line 134:
*[https://docs.google.com/spreadsheets/d/15iRs-JhfgkMto5rZVtG0hJjcLMiHy039_ahv2nus0UQ/edit?gid=0#gid=0 Si Etching with C<sub>4</sub>F<sub>8</sub>/SF<sub>6</sub>/CF<sub>4</sub> - '''Etch Data''']
*[https://docs.google.com/spreadsheets/d/15iRs-JhfgkMto5rZVtG0hJjcLMiHy039_ahv2nus0UQ/edit?gid=0#gid=0 Si Etching with C<sub>4</sub>F<sub>8</sub>/SF<sub>6</sub>/CF<sub>4</sub> - '''Etch Data''']
*[https://docs.google.com/spreadsheets/d/15iRs-JhfgkMto5rZVtG0hJjcLMiHy039_ahv2nus0UQ/edit?gid=1804752281#gid=1804752281 Si Etching with C<sub>4</sub>F<sub>8</sub>/SF<sub>6</sub>/CF<sub>4</sub> - '''Plots'''][[File:FICP-Si.png|alt=example of Process Control Charts|none|thumb|242x242px|[https://docs.google.com/spreadsheets/d/15iRs-JhfgkMto5rZVtG0hJjcLMiHy039_ahv2nus0UQ/edit?gid=1804752281#gid=1804752281 Click for Process Control Charts]|link=https://docs.google.com/spreadsheets/d/15iRs-JhfgkMto5rZVtG0hJjcLMiHy039_ahv2nus0UQ/edit?gid=1804752281#gid=1804752281]]
*[https://docs.google.com/spreadsheets/d/15iRs-JhfgkMto5rZVtG0hJjcLMiHy039_ahv2nus0UQ/edit?gid=1804752281#gid=1804752281 Si Etching with C<sub>4</sub>F<sub>8</sub>/SF<sub>6</sub>/CF<sub>4</sub> - '''Plots'''][[File:FICP-Si.png|alt=example of Process Control Charts|none|thumb|242x242px|[https://docs.google.com/spreadsheets/d/15iRs-JhfgkMto5rZVtG0hJjcLMiHy039_ahv2nus0UQ/edit?gid=1804752281#gid=1804752281 Click for Process Control Charts]|link=https://docs.google.com/spreadsheets/d/15iRs-JhfgkMto5rZVtG0hJjcLMiHy039_ahv2nus0UQ/edit?gid=1804752281#gid=1804752281]]
==[[ICP Etching Recipes#Process Control Data .28Panasonic 1.29|Panasonic ICP #1]]==
==[[ICP Etching Recipes#Process Control Data .28Panasonic 1.29|Panasonic ICP #1]] - Process Control==


*[https://docs.google.com/spreadsheets/d/1gBqCYXSl7IqpNL-yI11cuURlfZpTWwXUVM9hY_gGpT8/edit?usp=sharing SiO<sub>2</sub> Etch with CHF<sub>3</sub>/CF<sub>4</sub> - '''Etch Data''']
*[https://docs.google.com/spreadsheets/d/1gBqCYXSl7IqpNL-yI11cuURlfZpTWwXUVM9hY_gGpT8/edit?usp=sharing SiO<sub>2</sub> Etch with CHF<sub>3</sub>/CF<sub>4</sub> - '''Etch Data''']
Line 123: Line 143:
*[[Test Data of etching SiO2 with CHF3/CF4-ICP1|SiO<sub>2</sub> Etch with CHF<sub>3</sub>/CF<sub>4</sub> (Panasonic 1)]] - ''No data prior to 2023-01-20''
*[[Test Data of etching SiO2 with CHF3/CF4-ICP1|SiO<sub>2</sub> Etch with CHF<sub>3</sub>/CF<sub>4</sub> (Panasonic 1)]] - ''No data prior to 2023-01-20''


==[[ICP Etching Recipes#Process Control Data .28Panasonic 2.29|Panasonic ICP#2]]==
== [[ICP Etching Recipes#Process Control Data .28Panasonic 2.29|Panasonic ICP#2]] - Process Control ==

=== GaAs Etch with N<sub>2</sub>/Cl<sub>2</sub> - Process Control Data (Panasonic 2) ===

* [https://docs.google.com/spreadsheets/d/16gHOO3PQn_LinrXGPeSTSBf5dnw3leSLh1gq0PLr43w/edit?gid=0#gid=0 GaAs Etch with N2/Cl2 - '''Etch Data''']
* [https://docs.google.com/spreadsheets/d/16gHOO3PQn_LinrXGPeSTSBf5dnw3leSLh1gq0PLr43w/edit?gid=1804752281#gid=1804752281 GaAs Etch with N2/Cl2 - '''Plots'''][[File:GaAs_Etch_ICP2_SPC.png|link=https://docs.google.com/spreadsheets/d/16gHOO3PQn_LinrXGPeSTSBf5dnw3leSLh1gq0PLr43w/edit?gid=1804752281#gid=1804752281|alt=example ICP2 process control chart|none|thumb|249x249px|[https://docs.google.com/spreadsheets/d/16gHOO3PQn_LinrXGPeSTSBf5dnw3leSLh1gq0PLr43w/edit?gid=1804752281#gid=1804752281 Click for Process Control Charts]]]

=== SiO<sub>2</sub> Etch with CHF<sub>3</sub>/CF<sub>4</sub> - Process Control Data (Panasonic 2) ===




*[https://docs.google.com/spreadsheets/d/1m0l_UK2lDxlgww4f6nfXe4aQedNeDZsLs46jQ5wR4zw/edit?usp=sharing SiO<sub>2</sub> Etch with CHF<sub>3</sub>/CF<sub>4</sub> - '''Etch Data''']
*[https://docs.google.com/spreadsheets/d/1m0l_UK2lDxlgww4f6nfXe4aQedNeDZsLs46jQ5wR4zw/edit?usp=sharing SiO<sub>2</sub> Etch with CHF<sub>3</sub>/CF<sub>4</sub> - '''Etch Data''']
Line 132: Line 161:
*[[Test Data of etching SiO2 with CHF3/CF4|SiO<sub>2</sub> Etching with CHF<sub>3</sub>/CF<sub>4</sub> - ICP2]] - ''No data prior to 2023-01-20''
*[[Test Data of etching SiO2 with CHF3/CF4|SiO<sub>2</sub> Etching with CHF<sub>3</sub>/CF<sub>4</sub> - ICP2]] - ''No data prior to 2023-01-20''


==[[ICP Etching Recipes#Process Control Data .28Unaxis VLR.29|Unaxis VLR Etch]]==
==[[ICP Etching Recipes#Process Control Data .28Unaxis VLR.29|Unaxis VLR Etch]] - Process Control==


*[[Unaxis VLR Etch - Process Control Data|InP Etching with Cl<sub>2</sub>/N<sub>2</sub> @ 200°C - Unaxis Etch]]
*[[Unaxis VLR Etch - Process Control Data|InP Etching with Cl<sub>2</sub>/H/Ar @ 200°C - Unaxis Etch]]


==[[ICP Etching Recipes#Process Control Data .28Oxford ICP Etcher.29|Oxford PlasmaPro Cobra Etcher]]==
==[[ICP Etching Recipes#Process Control Data .28Oxford ICP Etcher.29|Oxford PlasmaPro Cobra Etcher]] - Process Control==


=== InP Ridge Etch: Cl<sub>2</sub>/CH<sub>4</sub>/H<sub>2</sub>/60°C ===
=== Std InP Ridge Etch Cl<sub>2</sub>/H<sub>2</sub>/Ar/200°C ===
''Calibration / Process testing data taken using the "InP Ridge Etch" process: Cl2/CH4/H2 @ 60°C, 1cm piece with ~50% SiO2 hardmask.''
''Calibration / Process testing data taken using the "InP Ridge Etch" process: Cl2/H2/Ar @ 200°C, 1cm piece with ~50% SiO2 hardmask.''

* [https://docs.google.com/spreadsheets/d/1LE5Cug9uJFYEwu0ZsNsp0W1dTRzcO2EKFhC0wu3w0n4/edit?gid=0#gid=0 "Std InP Ridge Etch" Cl<sub>2</sub>/H<sub>2</sub>/Ar 200°C - '''Etch Data Tables''']
* [https://docs.google.com/spreadsheets/d/1LE5Cug9uJFYEwu0ZsNsp0W1dTRzcO2EKFhC0wu3w0n4/edit?gid=1804752281#gid=1804752281 "Std InP Ridge Etch" Cl<sub>2</sub>/H<sub>2</sub>/Ar 200°C - '''Plots''']
[[File:200C InP.png|alt=example SPC chart for Oxford ICP Etcher|none|thumb|276x276px|[https://docs.google.com/spreadsheets/d/1LE5Cug9uJFYEwu0ZsNsp0W1dTRzcO2EKFhC0wu3w0n4/edit?gid=1804752281#gid=1804752281 Click for Process Control Charts]|link=https://docs.google.com/spreadsheets/d/1LE5Cug9uJFYEwu0ZsNsp0W1dTRzcO2EKFhC0wu3w0n4/edit?gid=1804752281#gid=1804752281]]

=== Std InP Ridge Etch: Cl<sub>2</sub>/CH<sub>4</sub>/H<sub>2</sub>/60°C ===
''Calibration / Process testing data taken using the "InP Ridge Etch" process: Cl2/CH4/H2 @ 60°C, 1cm piece with ~50% SiO2 hardmask. <u>No longer calibrating this recipe.</u>''


*[https://docs.google.com/spreadsheets/d/1cEUB7K5BAg9N4vp3rPZw7g0orFkxeQmRkX34Fb4eZco/edit?gid=0#gid=0 "Std InP Ridge Etch" Cl<sub>2</sub>/CH<sub>4</sub>/H<sub>2</sub>/60°C - '''Etch Data Tables''']
*[https://docs.google.com/spreadsheets/d/1cEUB7K5BAg9N4vp3rPZw7g0orFkxeQmRkX34Fb4eZco/edit?gid=0#gid=0 "Std InP Ridge Etch" Cl<sub>2</sub>/CH<sub>4</sub>/H<sub>2</sub>/60°C - '''Etch Data Tables''']
Line 156: Line 192:
<hr style="height:5px">
<hr style="height:5px">


== [[DSEIII (PlasmaTherm/Deep Silicon Etcher)|PlasmaTherm DSEIII Deep Silicon Etcher]] ==
== [[DSEIII (PlasmaTherm/Deep Silicon Etcher)|PlasmaTherm DSEIII Deep Silicon Etcher]] - Process Control ==


=== Si Bosch Etching C<sub>4</sub>F<sub>8</sub>/SF<sub>6</sub>/Ar ===
=== Si Bosch Etching C<sub>4</sub>F<sub>8</sub>/SF<sub>6</sub>/Ar ===
Line 169: Line 205:
''Process Control Data for Nanofab Lithography/patterning tools.''
''Process Control Data for Nanofab Lithography/patterning tools.''


==[[Stepper_Recipes#Stepper_3_.28ASML_DUV.29|Stepper #3 (ASML DUV)]]==
==[[Stepper_Recipes#Stepper_3_.28ASML_DUV.29|Stepper #3 (ASML DUV)]] - Process Control==


*''The Process Group regularly measures data on lithography Critical Dimension ("CD") and Wafer-stage Particulate Contamination for this tool, using a sensitive lithography process that will reveal small changes in Dose repeatability and wafer flatness.''
*''The Process Group regularly measures data on lithography Critical Dimension ("CD") and Wafer-stage Particulate Contamination for this tool, using a sensitive lithography process that will reveal small changes in Dose repeatability and wafer flatness.''
Line 179: Line 215:
|[[File:ASML CD Cals - Example Plot.jpg|alt=ASML CD Calibration Data - Screenshot of SPC Plot|none|thumb|''Example SPC Chart - Measured Critical Dimension "CD" versus Date. [https://docs.google.com/spreadsheets/d/1xW1TFH_QjPMWl9T1jiKzwmYe4B2wg7KY-nqOKUoXttI/edit#gid=1804752281 Click for charts.]''|link=https://docs.google.com/spreadsheets/d/1xW1TFH_QjPMWl9T1jiKzwmYe4B2wg7KY-nqOKUoXttI/edit#gid=1804752281]]
|[[File:ASML CD Cals - Example Plot.jpg|alt=ASML CD Calibration Data - Screenshot of SPC Plot|none|thumb|''Example SPC Chart - Measured Critical Dimension "CD" versus Date. [https://docs.google.com/spreadsheets/d/1xW1TFH_QjPMWl9T1jiKzwmYe4B2wg7KY-nqOKUoXttI/edit#gid=1804752281 Click for charts.]''|link=https://docs.google.com/spreadsheets/d/1xW1TFH_QjPMWl9T1jiKzwmYe4B2wg7KY-nqOKUoXttI/edit#gid=1804752281]]
|}
|}

== Maskless Aligner (Heidelberg MLA150) - Process Control ==

* ''The Process Group measures the smallest "clean" line-space pitch (by SEM) at different locations on the wafer, and calls this the "best resolution" for that region of the wafer.'' ''Measured with 0.25µm steps.''
* [https://docs.google.com/spreadsheets/d/1DbvFFNYeKeS1hG0Hnd-vCQs8CfqnMj2ABdjUv3lyssg/edit?usp=drive_link '''Data sheet'''], listing measured values, includes links to travelers & SEM's etc.
* [https://docs.google.com/spreadsheets/d/1DbvFFNYeKeS1hG0Hnd-vCQs8CfqnMj2ABdjUv3lyssg/edit?gid=167054213#gid=167054213 '''Plots''' of "best" resolution across wafer] - chart of resolution vs. time

[[File:MLA LithoCal Chart screenshot.png|alt=MLA LithoCal Chart screenshot|none|thumb|Example SPC Charts for MLA LithoCal "best" resolution. ]]
:

Latest revision as of 17:48, 11 August 2026

Process Control Data are standardized processes, run by the NanoFab, allowing for day-to-day or year-by-year comparisons of a tool's performance at the process level. This is similar Statistical Process Control (SPC).

These are the same links are found on individual tool pages, in the <<tool page>> > Process Control section.

Data are collected by our Process Group Interns and reviewed by Process Group Staff.

Deposition, Dielectric (Process Control Data)

SPC chart example
Example Process Control Charts (SPC) for thin-film DepCals.
screenshot of surfscan particle count
Example particle counts taken on each tool+film.
Screenshot of Filmetrics F50 wafermap of typical DepCals film
Example of DepCals Thickness/Refractive Index uniformity measurement (4% shown here).

Process Control data for various deposition tools in the lab.

PECVD #1 (PlasmaTherm 790) - Process Control

PECVD #2 (Advanced Vacuum) - Process Control

ICP-PECVD (Unaxis VLR Dep) - Process Control

Ion Beam Sputter Deposition (Veeco Nexus) - Process Control

Old Data (Pre 2022)

Old data in a different format can be found below:




Deposition, Metal - Process Control Data

Process Control data for various deposition tools in the lab.

Sputter 5 (AJA ATC 2200-V) - Process Control

Screenshot of Sputter 5 Titanium Sheet Resistance process control chart
Sputter 5 Titanium - Sheet Resistance - Process Control Chart - Example data only. ← click a link for live data.

Sputter 5: Ti

Sputter 5: Al

Sputter 5: Cr

E-Beam 4 (CHA) - Process Control

Screenshot of E-Beam 4 Titanium Stress - process control chart
E-Beam 4 Titanium Stress - Process Control Chart. Example data only - ← click a link for live data.

E-Beam 4: Ti

E-Beam 4: Au

E-Beam 4: Cr

E-Beam 4: Ni

E-Beam 1 (Sharon) - Process Control

E-Beam 1: Ti

E-Beam 1: Au

E-Beam 1: Cr

E-Beam 1: Ni



Etching (Process Control Data)

Process Control data for various dry etching tools in the lab.

PlasmaTherm SLR Fluorine Etcher - Process Control

SiO2 Etching (FL-ICP Process Control)

We have found that SiO2 etching is fairly insensitive to chamber condition.

Old SiO2 Process Control Data

Si Etching (FL-ICP Process Control)

This Si etch is much more sensitive to chamber condition, allowing us to detect chamber contamination faster.

  • Recipe: SiVertHFv2 - C4F8/SF6/CF4 etch of 100mm Silicon Wafer with ~50% open area and resist mask

Panasonic ICP #1 - Process Control

Old Process Control Data

Panasonic ICP#2 - Process Control

GaAs Etch with N2/Cl2 - Process Control Data (Panasonic 2)

SiO2 Etch with CHF3/CF4 - Process Control Data (Panasonic 2)

Old Process Control Data

Unaxis VLR Etch - Process Control

Oxford PlasmaPro Cobra Etcher - Process Control

Std InP Ridge Etch Cl2/H2/Ar/200°C

Calibration / Process testing data taken using the "InP Ridge Etch" process: Cl2/H2/Ar @ 200°C, 1cm piece with ~50% SiO2 hardmask.

example SPC chart for Oxford ICP Etcher
Click for Process Control Charts

Std InP Ridge Etch: Cl2/CH4/H2/60°C

Calibration / Process testing data taken using the "InP Ridge Etch" process: Cl2/CH4/H2 @ 60°C, 1cm piece with ~50% SiO2 hardmask. No longer calibrating this recipe.

Old InP Ridge Etch Data

GaN Etch (Cl2/BCl3/Ar/200°C)

Recipe: Std GaN Etch - BCl3/Cl2/Ar - 200C (Public), on 1cm x 1cm ~1.2µm deep GaN etch with Cl2/BCl3/Ar at 200°C. Sapphire substrate with SiO2 mask for GaN.



PlasmaTherm DSEIII Deep Silicon Etcher - Process Control

Si Bosch Etching C4F8/SF6/Ar

  • Recipe: STD_Bosch_Si (⭐️Production), on 100mm Si Wafer with ~50% open area, photoresist mask, ~40µm deep


Lithography (Process Control Data)

Process Control Data for Nanofab Lithography/patterning tools.

Stepper #3 (ASML DUV) - Process Control

ASML CD Calibration data - Screenshot of Table
Example of Data Table with SEM's of 320nm features. Click for full data table.
ASML CD Calibration Data - Screenshot of SPC Plot
Example SPC Chart - Measured Critical Dimension "CD" versus Date. Click for charts.

Maskless Aligner (Heidelberg MLA150) - Process Control

  • The Process Group measures the smallest "clean" line-space pitch (by SEM) at different locations on the wafer, and calls this the "best resolution" for that region of the wafer. Measured with 0.25µm steps.
  • Data sheet, listing measured values, includes links to travelers & SEM's etc.
  • Plots of "best" resolution across wafer - chart of resolution vs. time
MLA LithoCal Chart screenshot
Example SPC Charts for MLA LithoCal "best" resolution.