=== Filmetrics Optical Profilometer ===
A new Filmetrics optical profilometer will be installed in the next month. The system complements the Confocal Microscope, by providing large-area profiles (~5-10mm square) with nanometer-level height resolution.
// [[User:John d|John d]] 10:59, 14 December 2018 (PST)


=== Die-Bonder & Wirebonder Installed at Protofab ===
=== Filmetrics Optical Measurement Systems ===
We have installed a [https://protowiki.oasis.ucsb.edu/index.php/Flip-Chip_and_Die_Bonder_(Tresky_T-5300-W) new Tresky Flip-chip/Die-bonder] & [https://protowiki.oasis.ucsb.edu/index.php/Ball_%26_Wedge_Bonding_(F%26S_56i_Wire_Bonder) F&S Wirebonder] at the [https://protofab.oasis.ucsb.edu/ Protofab]. The wirebonder allows fast automatic wirebonding, capable of hundreds of wirebonds in minutes. The die-bonder enables solder bonding chips to carriers/PCB's and related capabilities. Contact staff at the above wiki pages for training.
A [[Optical Film Spectra + Optical Properties (Filmetrics F10-RT-UVX)|Filmetrics F10-RT]] for optical reflection/transmission spectra, and a [[Optical Film Thickness & Wafer-Mapping (Filmetrics F50)|Filmetrics F50]] thin-film wafer-mapping system have been installed. Contact Ning Cao for more info.
// [[User:John d|John d]] 15:24, 12 December 2018 (PST)
// [[User:John_d|Demis D. John]] 19:53, 3 October 2026 (UTC)


=== "Make Microchips!" - new book by Nanofab staff ===
⚫
=== KLA Tencor Profilometer Installed ===
Nanofab staff [[Demis D. John]] published an intro-level book for people wanting to learn about making microchips, it is [https://www.amazon.com/dp/B0HDRHG3KM '''available now on Amazon''']. The book compliments the [https://nanofab.ucsb.edu/workforce#bootcamps Cleanroom Bootcamps] and other [https://nanofab.ucsb.edu/workforce workforce development efforts] Demis has launched, to help people get into the semiconductor industry.
We have purchased a new [[Step Profilometer (KLA Tencor P-7)|KLA Tencor Stylus Profilometer]], that has been installed in Bay 4.
// [[User:John d|John d]] 17:28, 12 September 2018 (PDT)
// [[User:John_d|Demis D. John]] 15:30, 22 August 2026 (UTC)


=== Carpinteria Highschool does Microchip Packaging ===
=== Laser Endpoint Monitors ===
The SB Chamber of Commerce sponsored Carpinteria Highschool to do microchip packaging using their machine shop in the CHIP program! Under the mentorship of Nanofab staff [[Demis D. John]] and Ben Werner from [https://www.pseudolithic.com/ PseudolithIC], 3 student teams designed the microchip packaging for micro-pressure sensors, MEMS chips made during the [https://nanofab.ucsb.edu/workforce#bootcamps CC-PRIME cleanroom bootcamps]. The SBSC Chamber released [https://sbscchamber.com/chip/ a video about the program here], you can learn more [https://innovation.ucsb.edu/blog/news/ucsb-partnership-opens-doors-semiconductor-careers-high-school-students at this article].
We've installed new [http://www.intellemetrics.com/LEP.htm Intellemetrics LEP500 Laser Endpoint Detection] monitoring on the [[DSEIII_(PlasmaTherm/Deep_Silicon_Etcher)|DSEiii]] & [[ICP_Etch_2_(Panasonic_E640)|ICP#2]] & [[ICP_Etch_1_(Panasonic_E626I)|ICP#1]] etchers. This allows you to terminate your etch at a calibrated/modeled distance into a layer, and removes the need to calibrate etch rates for most processes.
// [[User:John d|John d]] 09:26, 17 July 2018 (PDT)
// [[User:John_d|Demis D. John]] 10:00, 13 August 2026 (UTC)


⚫
=== Raith PicoMaster Direct-Write Installed ===
=== Metal Processes on the Atomic Layer Deposition ===
We have installed a new H-Line (405nm) Direct-write tool: The [[Maskless_Aligner_(Raith_PicoMaster_XF)]]. The new tool is currently undergoing staff qualifications and we are developing operating procedures. // [[User:John_d|Demis D. John]] 19:02, 18 July 2026 (UTC)
We now have Ruthenium (Ru) and Platinum (Pt) metal depositions developed on the [[Atomic_Layer_Deposition_(Oxford_FlexAL)|Oxford FlexAL ALD]] tool. See the [[Atomic_Layer_Deposition_Recipes|Atomic Layer Deposition: Recipes]] page or contact [[Bill_Mitchell|Bill Mitchell]] for more information.
⚫
// [[User:John d|Posted:]] 16:07, 01 June 2017 (PST)


===ProtoFab Opening Summer 2026===
=== New Deep Silicon Etcher Online ===
The Nanofab is launching a [https://protofab.oasis.ucsb.edu/ Prototyping Facility called the "Protofab"], which is located at [https://oasis.ucsb.edu/ UCSB's new OASIS building]. Learn more at [https://protofab.oasis.ucsb.edu https://protofab.oasis.ucsb.edu]
A new [[DSEIII_(PlasmaTherm/Deep_Silicon_Etcher)|Plasma-Therm Versaline DSE III DRIE etcher]] has been qualified for bosch etch and single-step etches, and is available for use. The new tool features much higher silicon etch rates, improved uniformity, and allows for photoresist up to the edges of the wafer. An Intellemetrics LEP500 laser end point monitor has also been installed on the system.
// [[User:John d|Posted:]] 22:16, 27 November 2017 (PST)


The new lab will enable taking your diced chips from the Nanofab, to the Protofab where you can wirebond, attach to PCB's/carriers, align+attach optical fibers etc., to make a real "prototype". The lab is expected to open in Summer 2026, with equipment currently being installed.
=== 2016 Survey Results ===
See the May 2016 {{file|Survey052016.pdf| User Survey Results}}.
⚫
// [[User:Thibeault|Posted:]] 12:00, 01 May 2016 (PST)


Access & model is similar to the Nanofab - anyone can pay an hourly fee to go into the Protofab, using key fobs for access. (OASIS "Membership" is ''not required'' to use the Protofab, unless you also want your own desk + private lab space at OASIS.)
=== CAIBE Ion Mill Available ===
The [[CAIBE (Oxford Ion Mill)]] is up and running! Contact [[Brian Lingg]] for more information.
// [[User:Thibeault|Posted:]] 12:00, 01 July 2015 (PST)


Contact the Protofab lab manager [mailto:arin_abed@ucsb.edu Arin Abed] for more information.
=== NanoFiles SFTP Online ===
⚫
// [[User:John_d|Demis D. John]] 19:51, 27 May 2026 (UTC)
Files generated with Nanofab tools (SEM images, AFM profiles, etc.) are now available on the nanofab SFTP server. Please check [http://signupmonkey.ece.ucsb.edu SignupMonkey] for details.

// [[User:Thibeault|Posted:]] 12:00, 07 July 2013 (PST)
===CS MANTECH Poster: "Machine Matching Methodology for Single-shot Lab to Lab Dry Etch Process Transfer" ===
Nanofab staff Foong Fatt, Noah Dutra and Brian Thibeault presented a poster at CS MANTECH (compound semiconductor manufacturing technology) in Portland Oregon. The paper describes using [https://www.pdf.com/products/exensio-analytics-platform/overview/ PDF Solutions Exensio analytics] to do a single-shot dry etch process transfer from the UCSB Nanofab's Oxford Cobra ICP etcher to a different-configuration ICP etcher at UC San Diego's, reproducing etch rate and sidewall profile in a single-shot. The technique used complimentary L9 DOE's at each site to map out the process space, allowing for single-shot matching. [[Media:2026_CSMANTECH_Paper-2366_-_Foong_Fatt_-_Machine_Matching_Methodology_for_Single-shot_Lab_to_Lab_Dry_Etch_Process_Transfer.pdf|See the full paper here]].
// [[User:John_d|Demis D. John]] 15:53, 22 August 2026 (UTC)

===Video: Scalable R&D Tips from Nanofab Staff===
Demis D. John presented a seminar to the [https://ca-dreams.org/ CA DREAMS Microelectronics Commons Hub] detailing common methods and thought-processes for making novel, advanced microchips as fast and low-cost as possible. See the [https://www.youtube.com/watch?v=ENdgmvlbsU0 Seminar titled "Scalable Manufacturing in an R&D Lab: Supporting Startup/Research Success in a high-mix environment" on Youtube]
⚫
// [[User:John_d|Demis D. John]] 02:13, 12 June 2026 (UTC)


<!---------- end of announcements ------------>
<!---------- end of announcements ------------>
<!---------------------------------------------->
<!---------------------------------------------->
<!--DO NOT EDIT BELOW THIS LINE-->
<!--DO NOT EDIT BELOW THIS LINE-->
===''[[Template:News_-_Older_Articles|See older articles at this link]]''===
<endfeed />
<endfeed />
<noinclude>[[Category:Templates]]</noinclude>
<noinclude>[[Category:Templates]]</noinclude>

Latest revision as of 23:47, 3 October 2026

News from the U.C. Santa Barbara Nanofabrication Facility.

Die-Bonder & Wirebonder Installed at Protofab

We have installed a new Tresky Flip-chip/Die-bonder & F&S Wirebonder at the Protofab. The wirebonder allows fast automatic wirebonding, capable of hundreds of wirebonds in minutes. The die-bonder enables solder bonding chips to carriers/PCB's and related capabilities. Contact staff at the above wiki pages for training. // Demis D. John 19:53, 3 October 2026 (UTC)

"Make Microchips!" - new book by Nanofab staff

Nanofab staff Demis D. John published an intro-level book for people wanting to learn about making microchips, it is available now on Amazon. The book compliments the Cleanroom Bootcamps and other workforce development efforts Demis has launched, to help people get into the semiconductor industry. // Demis D. John 15:30, 22 August 2026 (UTC)

Carpinteria Highschool does Microchip Packaging

The SB Chamber of Commerce sponsored Carpinteria Highschool to do microchip packaging using their machine shop in the CHIP program! Under the mentorship of Nanofab staff Demis D. John and Ben Werner from PseudolithIC, 3 student teams designed the microchip packaging for micro-pressure sensors, MEMS chips made during the CC-PRIME cleanroom bootcamps. The SBSC Chamber released a video about the program here, you can learn more at this article. // Demis D. John 10:00, 13 August 2026 (UTC)

Raith PicoMaster Direct-Write Installed

We have installed a new H-Line (405nm) Direct-write tool: The Maskless_Aligner_(Raith_PicoMaster_XF). The new tool is currently undergoing staff qualifications and we are developing operating procedures. // Demis D. John 19:02, 18 July 2026 (UTC)

ProtoFab Opening Summer 2026

The Nanofab is launching a Prototyping Facility called the "Protofab", which is located at UCSB's new OASIS building. Learn more at https://protofab.oasis.ucsb.edu

The new lab will enable taking your diced chips from the Nanofab, to the Protofab where you can wirebond, attach to PCB's/carriers, align+attach optical fibers etc., to make a real "prototype". The lab is expected to open in Summer 2026, with equipment currently being installed.

Access & model is similar to the Nanofab - anyone can pay an hourly fee to go into the Protofab, using key fobs for access. (OASIS "Membership" is not required to use the Protofab, unless you also want your own desk + private lab space at OASIS.)

Contact the Protofab lab manager Arin Abed for more information. // Demis D. John 19:51, 27 May 2026 (UTC)

CS MANTECH Poster: "Machine Matching Methodology for Single-shot Lab to Lab Dry Etch Process Transfer"

Nanofab staff Foong Fatt, Noah Dutra and Brian Thibeault presented a poster at CS MANTECH (compound semiconductor manufacturing technology) in Portland Oregon. The paper describes using PDF Solutions Exensio analytics to do a single-shot dry etch process transfer from the UCSB Nanofab's Oxford Cobra ICP etcher to a different-configuration ICP etcher at UC San Diego's, reproducing etch rate and sidewall profile in a single-shot. The technique used complimentary L9 DOE's at each site to map out the process space, allowing for single-shot matching. See the full paper here. // Demis D. John 15:53, 22 August 2026 (UTC)

Video: Scalable R&D Tips from Nanofab Staff

Demis D. John presented a seminar to the CA DREAMS Microelectronics Commons Hub detailing common methods and thought-processes for making novel, advanced microchips as fast and low-cost as possible. See the Seminar titled "Scalable Manufacturing in an R&D Lab: Supporting Startup/Research Success in a high-mix environment" on Youtube // Demis D. John 02:13, 12 June 2026 (UTC)

See older articles at this link