Stocked Chemical List: Difference between revisions

From UCSB Nanofab Wiki
Jump to navigation Jump to search
Content deleted Content added
m sorting
added crystalbond 509 wax
 
(6 intermediate revisions by the same user not shown)
Line 1: Line 1:
''You can sort the following table using the ↑ / ↓ buttons in the title row.''
''You can sort the following table using the ↑ / ↓ buttons in the title row. Your browser's "Find" ⌘-F function also works.''
{| class="wikitable sortable"
{| class="wikitable sortable"
!'''CHEMICAL'''
!'''CHEMICAL'''
!'''DESCRIPTION'''
!'''DESCRIPTION'''
!'''VENDOR'''
!'''VENDOR'''
!Other Names/Notes
|-
|-
|Acetone, 4L, 4 bt = 1 cs
|Acetone, 4L, 4 bt = 1 cs
|ACETONE ACS SAFE-COTE 4L Percent Purity ≥99.5%
|ACETONE ACS SAFE-COTE 4L Percent Purity ≥99.5%
|FISHER SCIENTIFIC
|FISHER SCIENTIFIC
|ACE
|-
|-
|Propanol, 4L, 4 bt = 1 cs
|Propanol, 4L, 4 bt = 1 cs
|2-PROPANOL OPTIM AGRADE Percent Purity ≥99.9%
|2-PROPANOL OPTIM AGRADE Percent Purity ≥99.9%
|FISHER SCIENTIFIC
|FISHER SCIENTIFIC
|ISO, IPA, Isopropanol
|-
|-
|Ethanol
|Ethanol
|DEHYDRATED ALCOHOL, 200 PROOF, UNDENATURED, USP GRADE- 4LGLASS
|DEHYDRATED ALCOHOL, 200 PROOF, UNDENATURED, USP GRADE- 4LGLASS
|SPECTRUM CHEMICALS & LAB
|SPECTRUM CHEMICALS & LAB
|
|-
|-
|Methanol, 4L, 4 bt = 1 cs
|Methanol, 4L, 4 bt = 1 cs
|METHANOL OPTIMA GRADE 4L Percent Purity ≥99.9%
|METHANOL OPTIMA GRADE 4L Percent Purity ≥99.9%
|FISHER SCIENTIFIC
|FISHER SCIENTIFIC
|
|-
|-
|Toluene, 4 L
|Toluene, 4 L
|TOLUENE OPTIMA GRADE 4L Percent Purity ≥99.8%
|TOLUENE OPTIMA GRADE 4L Percent Purity ≥99.8%
|FISHER SCIENTIFIC
|FISHER SCIENTIFIC
|
|-
|-
|Ethylene Glycol
|Ethylene Glycol
|ETHYLENE GLYCOL LABORATORY GRADE
|ETHYLENE GLYCOL LABORATORY GRADE
|FISHER SCIENTIFIC
|FISHER SCIENTIFIC
|
|-
|-
|Amyl Acetate, 4L bottle
|Amyl Acetate, 4L bottle
|AMYL ACETATE LABORATORY GRADE 4L
|AMYL ACETATE LABORATORY GRADE 4L
|FISHER SCIENTIFIC
|FISHER SCIENTIFIC
|
|-
|-
|MIBK, 4L bottle
|MIBK, 4L bottle
|Methyl iso-Butyl Ketone (Certified ACS), Grade Certified ACS Reagent
|Methyl iso-Butyl Ketone (Certified ACS), Grade Certified ACS Reagent
|FISHER SCIENTIFIC
|FISHER SCIENTIFIC
|
|-
|-
|Chloroform, 2.5 L
|Chloroform, 2.5 L
|Chloroform, 99+%, Acros Organics
|Chloroform, 99+%, Acros Organics
|FISHER SCIENTIFIC
|FISHER SCIENTIFIC
|
|-
|-
|Xylenes, 1 liter
|Xylenes, 1 liter
|XYLENES ACS 4L Percent Purity ≥98.5%
|XYLENES ACS 4L Percent Purity ≥98.5%
|FISHER SCIENTIFIC
|FISHER SCIENTIFIC
|
|-
|-
|T1100 BCB rinse solvent
|T1100 BCB rinse solvent
|RINCE T1100 4 LITER GLASS BOTTLE
|RINSE T1100 4 LITER GLASS BOTTLE
|MICROCHEM CORP.
|MICROCHEM CORP.
|
|-
|-
|Nitric, 500ml.
|Nitric, 500ml.
|NITRIC ACID IND SAFECOTE 2,5L, Assay Percent Range 70%
|NITRIC ACID IND SAFECOTE 2,5L, Assay Percent Range 70%
|FISHER SCIENTIFIC
|FISHER SCIENTIFIC
|
|-
|-
|Sulfuric, 2.5 L
|Sulfuric, 2.5 L
|SULFURIC AC 21/2L IND SAFECOTE Assay Percent Range 95.0 to 98.0 w/w %
|SULFURIC AC 21/2L IND SAFECOTE Assay Percent Range 95.0 to 98.0 w/w %
|FISHER SCIENTIFIC
|FISHER SCIENTIFIC
|H2SO4
|-
|-
|O-Phosphoric, 2.5 L
|O-Phosphoric, 2.5 L
|O-PHOSPHORIC ACID Percent Purity ≥85.0% (w/w)
|O-PHOSPHORIC ACID Percent Purity ≥85.0% (w/w)
|FISHER SCIENTIFIC
|FISHER SCIENTIFIC
|H3PO4
|-
|-
|Citric acid, liquid, 1.0 M, 1L
|Citric acid, liquid, 1.0 M, 1L
|CITRIC ACID, 1.00 Molar
|CITRIC ACID, 1.00 Molar
|FISHER SCIENTIFIC
|FISHER SCIENTIFIC
|C6H8O7, solution
|-
|-
|50/50 w/w Citric Acid Monohydrate in Water
|50/50 w/w Citric Acid Monohydrate in Water
|PREMIX CITRIC ACID CAW 1:1
|PREMIX CITRIC ACID CAW 1:1
|TRANSENE COMPANY, INC.
|TRANSENE COMPANY, INC.
|C6H8O7, solution
|-
|-
|Citric acid, granular, monohydrate, 3 kg
|Citric acid, granular, monohydrate, 3 kg
|CITRIC ACID GRAN CERT ACS 3KG Percent Purity 99.0 to 102.0%
|CITRIC ACID GRAN CERT ACS 3KG Percent Purity 99.0 to 102.0%
|FISHER SCIENTIFIC
|FISHER SCIENTIFIC
|C6H8O7, powder
|-
|-
|Acetic, 2.5L
|Acetic, 2.5L
|ACETIC ACID GLACIAL ACS 2.5L IND SAF-CT Assay Percent Range: ≥99.7% w/w
|ACETIC ACID GLACIAL ACS 2.5L IND SAF-CT Assay Percent Range: ≥99.7% w/w
|FISHER SCIENTIFIC
|FISHER SCIENTIFIC
|
|-
|-
|Hydrochloric, 2.5L
|Hydrochloric, 2.5L
|HYDROCHLORIC ACID Percent Purity 36.5 to 38.0% (w/w)
|HYDROCHLORIC ACID Percent Purity 36.5 to 38.0% (w/w)
|FISHER SCIENTIFIC
|FISHER SCIENTIFIC
|HCl
|-
|-
|Hydrofluoric, 49%, 500 Ml
|Hydrofluoric, 49%, 500 Ml
|HYDROFLUORIC ACID RGT 500ML Assay (HF) 48 - 51%
|HYDROFLUORIC ACID RGT 500ML Assay (HF) 48 - 51%
|VWR INTERNATIONAL
|VWR INTERNATIONAL
|HF
|-
|-
|Hydrofluoric, Buffered HF, 1 gal
|Hydrofluoric, Buffered HF, 1 gal
|BUFFER-HF
|BUFFER-HF
|TRANSENE COMPANY, INC.
|TRANSENE COMPANY, INC.
|BHF, "Buffered oxide etch"
4-8% HF
|-
|-
|Hydrobromic, 500 mL
|Hydrobromic, 500 mL
|HYDROBROMIC ACID 48% CERT ACS 500ML Percent Purity 47.0 to 49.0%
|HYDROBROMIC ACID 48% CERT ACS 500ML Percent Purity 47.0 to 49.0%
|FISHER SCIENTIFIC
|FISHER SCIENTIFIC
|HBr
|-
|-
|Chrome mask etchant, 1 qt
|Chrome mask etchant, 1 qt
|CHROMIUM ETCHANT 1020
|CHROMIUM ETCHANT 1020
|TRANSENE COMPANY, INC.
|TRANSENE COMPANY, INC.
|
|-
|-
|Aluminum etchant, A, 1 qt
|Aluminum etchant, A, 1 qt
|ALUMINUM ETCHANT TYPE A
|ALUMINUM ETCHANT TYPE A
|TRANSENE COMPANY, INC.
|TRANSENE COMPANY, INC.
|
|-
|-
|Aluminum etchant, D, 1 qt
|Aluminum etchant, D, 1 qt
|ALUMINUM ETCHANT TYPE D
|ALUMINUM ETCHANT TYPE D
|TRANSENE COMPANY, INC.
|TRANSENE COMPANY, INC.
|
|-
|-
|Gold etchant, TFA, 1 qt
|Gold etchant, TFA, 1 qt
|GOLD ETCHANT TFA
|GOLD ETCHANT TFA
|TRANSENE COMPANY, INC.
|TRANSENE COMPANY, INC.
|
|-
|-
|Nickel etchant, TFB, 1 qt.
|Nickel etchant, TFB, 1 qt.
|NICKEL ETCH TFB
|NICKEL ETCH TFB
|TRANSENE COMPANY, INC.
|TRANSENE COMPANY, INC.
|
|-
|-
|Titanium etchant, TFTN
|Titanium etchant, TFTN
|TITANIUM ETCHANT TFTN
|TITANIUM ETCHANT TFTN
|TRANSENE COMPANY, INC.
|TRANSENE COMPANY, INC.
|
|-
|-
|Nanostrip
|Nanostrip
|KMG-Nanostrip
|KMG-Nanostrip
|INTEGRATED MICRO MATERIALS
|INTEGRATED MICRO MATERIALS
|
|-
|-
|Oxalic Acid
|Oxalic Acid
|OXALIC ACID CERTIF ACS 500G Percent Purity 99.5 to 102.5%
|OXALIC ACID CERTIF ACS 500G Percent Purity 99.5 to 102.5%
|FISHER SCIENTIFIC
|FISHER SCIENTIFIC
|
|-
|-
|Formic Acid
|Formic Acid
|FORMIC ACID 2.5LT 98% (ACS)
|FORMIC ACID 2.5LT 98% (ACS)
|FISHER SCIENTIFIC
|FISHER SCIENTIFIC
|
|-
|-
|Chromic Acid (Chromium Trioxide)
|Chromic Acid (Chromium Trioxide)
|Chromium Trioxide (Crystalline/Certified ACS) Percent Purity ≥98.0%
|Chromium Trioxide (Crystalline/Certified ACS) Percent Purity ≥98.0%
|FISHER SCIENTIFIC
|FISHER SCIENTIFIC
|CrO3
|-
|-
|Ammonium hydroxide, 2.5 L
|Ammonium hydroxide, 2.5 L
|AMMONIUM HYDROXIDE ACS Assay Percent Range: 28.0 to 30.0 w/w %
|AMMONIUM HYDROXIDE ACS Assay Percent Range: 28.0 to 30.0 w/w %
|FISHER SCIENTIFIC
|FISHER SCIENTIFIC
|NH4OH
|-
|-
|Ammonium sulfide, 500 mL
|Ammonium sulfide, 500 mL
|AMMONIUM SULFIDE SOLUTION Assay Percent Range 20 to 24% (aqueous)
|AMMONIUM SULFIDE SOLUTION Assay Percent Range 20 to 24% (aqueous)
|FISHER SCIENTIFIC
|FISHER SCIENTIFIC
|(NH4)2S
|-
|-
|Sodium hydroxide, 1L
|Sodium hydroxide, 1L
|SODIUM HYDROX SOL 50% CERT 1L Percent Purity Inclusive between 50%
|SODIUM HYDROX SOL 50% CERT 1L Percent Purity Inclusive between 50%
|FISHER SCIENTIFIC
|FISHER SCIENTIFIC
|NaOH
|-
|-
|Potassium hydroxide, 43.
|Potassium hydroxide, 43.
|POT HYDROX SOL 45% CERT 4L Concentration or Composition (by Analyte or Components) 45%
|POT HYDROX SOL 45% CERT 4L Concentration or Composition (by Analyte or Components) 45%
|FISHER SCIENTIFIC
|FISHER SCIENTIFIC
|KOH
|-
|-
|Hydrogen peroxide, 500 mL
|Hydrogen peroxide, 500 mL
|HYDROGEN PEROXIDE 30% Percent Purity 30.0 to 32.0%
|HYDROGEN PEROXIDE 30% Percent Purity 30.0 to 32.0%
|FISHER SCIENTIFIC
|FISHER SCIENTIFIC
|H2O2
|-
|-
|Hydrogen peroxide, 1 gal
|Hydrogen peroxide, 1 gal
|HYDROGEN PEROXIDE 30% Percent Purity 30.0 to 32.0%
|HYDROGEN PEROXIDE 30% Percent Purity 30.0 to 32.0%
|FISHER SCIENTIFIC
|FISHER SCIENTIFIC
|H2O2
|-
|-
|TMAH, 25%, per liter
|TMAH, 25%, per liter
|TETRAMETHYLAMMONIUM HYDROXIDE, 25%
|TETRAMETHYLAMMONIUM HYDROXIDE, 25%
|TRANSENE COMPANY, INC.
|TRANSENE COMPANY, INC.
|
|-
|-
|Saturated Bromine Water (SBW), 1L
|Saturated Bromine Water (SBW), 1L
|BROMINE WATER RGT 500ML Percent Purity ≥99.5%
|BROMINE WATER RGT 500ML Percent Purity ≥99.5%
|FISHER SCIENTIFIC
|FISHER SCIENTIFIC
|Br2 : H2O
|-
|-
|AZ400k developer, concentrated, 1 gal
|AZ400k developer, concentrated, 1 gal
|AZ 400K CONCENTRATE PHOTORESIST DEVELOPER
|AZ 400K CONCENTRATE PHOTORESIST DEVELOPER
|INTEGRATED MICRO MATERIALS
|INTEGRATED MICRO MATERIALS
|
|-
|-
|AZ400k developer, 1:4 diluted, 1 gal
|AZ400k developer, 1:4 diluted, 1 gal
|AZ 400k 1:4 PHOTORESIST DEVELOPER
|AZ 400k 1:4 PHOTORESIST DEVELOPER
|INTEGRATED MICRO MATERIALS
|INTEGRATED MICRO MATERIALS
|Pre-diluted
|-
|-
|AZ 726 MIF developer, 1 gal
|AZ 726 MIF developer, 1 gal
|AZ 726 MIF DEVELOPER
|AZ 726 MIF DEVELOPER
|INTEGRATED MICRO MATERIALS
|INTEGRATED MICRO MATERIALS
|
|-
|-
|AZ NMP Rinse & Photoresist Stripper
|AZ NMP Rinse & Photoresist Stripper
|AZ® NMP Rinse & Photoresist Stripper
|AZ® NMP Rinse & Photoresist Stripper
|INTEGRATED MICRO MATERIALS
|INTEGRATED MICRO MATERIALS
|
|-
|-
|AZ 300 T, stripper, 1 gal.
|AZ 300 T, stripper, 1 gal.
|AZ 300T STRIPPER
|AZ 300T STRIPPER
|INTEGRATED MICRO MATERIALS
|INTEGRATED MICRO MATERIALS
|
|-
|-
|MicroChem 101A Developer, 1 gal
|MicroChem 101A Developer, 1 gal
|101A DEVELOPER
|101A DEVELOPER
|MICROCHEM CORP.
|MICROCHEM CORP.
|SAL 101A, XP 101A
|-
|-
|AZ 300 MIF Developer
|AZ 300 MIF Developer
|AZ 300 MIF DEVELOPER
|AZ 300 MIF DEVELOPER
|INTEGRATED MICRO MATERIALS
|INTEGRATED MICRO MATERIALS
|
|-
|-
|SU-8 Developer
|SU-8 Developer
|SU-8 DEVELOPER - 4 X 4L
|SU-8 DEVELOPER - 4 X 4L
|MICROCHEM CORP.
|MICROCHEM CORP.
|
|-
|-
|DS2100 BCB Developer
|DS2100 BCB Developer
|DEVELOPER DS2100
|DEVELOPER DS2100
|MICROCHEM CORP.
|MICROCHEM CORP.
|BCB Developer
|-
|-
|EC 11
|EC 11
|EC SOLVENT 11 - 4 GL CS
|EC SOLVENT 11 - 4 GL CS
|MICROCHEM CORP.
|MICROCHEM CORP.
|
|-
|-
|AZ EBR
|AZ EBR
|AZ EBR EDGE BEAD REMOVER
|AZ EBR EDGE BEAD REMOVER
|INTEGRATED MICRO MATERIALS
|INTEGRATED MICRO MATERIALS
|
|-
|-
|KwikStrip, gallon size
|KwikStrip, gallon size
|AZ KWIK STRIP PHOTORESIST STRIPPER
|AZ KWIK STRIP PHOTORESIST STRIPPER
|INTEGRATED MICRO MATERIALS
|INTEGRATED MICRO MATERIALS
|
|-
|-
|Remover PG, SU-8 stripper
|Remover PG, SU-8 stripper
|REMOVER PG - 4 X 4L
|REMOVER PG - 4 X 4L
|MICROCHEM CORP.
|MICROCHEM CORP.
|
|-
|-
|SPR 955 CM-0.9, 1 Gal.
|SPR 955 CM-0.9, 1 Gal.
|SPR 955CM-0.9 - 1 GL
|SPR 955CM-0.9 - 1 GL
|MICROCHEM CORP.
|MICROCHEM CORP.
|Photoresist, PR
|-
|-
|SPR 955 CM-1.8, 1 Gal.
|SPR 955 CM-1.8, 1 Gal.
|SPR 955CM-1.8 - 1 GL
|SPR 955CM-1.8 - 1 GL
|MICROCHEM CORP.
|MICROCHEM CORP.
|Photoresist, PR
|-
|-
|SPR 220-3.0, 1 gal.
|SPR 220-3.0, 1 gal.
|SPR 220-3.0 P.R. 1GL
|SPR 220-3.0 P.R. 1GL
|MICROCHEM CORP.
|MICROCHEM CORP.
|Photoresist, PR
|-
|-
|SPR 220-7.0, 1 GAL,
|SPR 220-7.0, 1 GAL,
|SPR 220-7.0 P.R. 1GL
|SPR 220-7.0 P.R. 1GL
|MICROCHEM CORP.
|MICROCHEM CORP.
|Photoresist, PR
|-
|-
|CEM-365 IS, for stepper, 1 pint.
|CEM-365 IS, for stepper, 1 pint.
|CEM365IS-QT
|CEM365IS-QT
|SHIN-ETSU MICROSI, INC.
|SHIN-ETSU MICROSI, INC.
|Photoresist, PR contrast enhancer
|-
|-
|OCG 825-35CS
|OCG 825-35CS
|OCG 825 35CS 1X1 GALLON GLASS
|OCG 825 35CS 1X1 GALLON GLASS
|GALLADE CHEMICAL
|GALLADE CHEMICAL
|Photoresist, PR
|-
|-
|AZ P4110 1Qt.
|AZ P4110 1Qt.
|AZ P4110 PHOTORESIST
|AZ P4110 PHOTORESIST
|INTEGRATED MICRO MATERIALS
|INTEGRATED MICRO MATERIALS
|Photoresist, PR
|-
|-
|AZ P4210  1Qt.
|AZ P4210  1Qt.
|AZ P4210 G-LINE/BROADBAND PHOTORESIST
|AZ P4210 G-LINE/BROADBAND PHOTORESIST
|INTEGRATED MICRO MATERIALS
|INTEGRATED MICRO MATERIALS
|Photoresist, PR
|-
|-
|AZ P4330 RS  1QT.
|AZ P4330 RS  1QT.
|AZ P4330-RS
|AZ P4330-RS
|INTEGRATED MICRO MATERIALS
|INTEGRATED MICRO MATERIALS
|Photoresist, PR
|-
|-
|AZ 5214-EIR  1QT.
|AZ 5214-EIR  1QT.
|AZ 5214-E IR PHOTORESIST
|AZ 5214-E IR PHOTORESIST
|INTEGRATED MICRO MATERIALS
|INTEGRATED MICRO MATERIALS
|Photoresist, PR
|-
|-
|AZ P4620 1QT
|AZ P4620 1QT
|AZP4620-1Q
|AZP4620-1Q
|INTEGRATED MICRO MATERIALS
|INTEGRATED MICRO MATERIALS
|Photoresist, PR
|-
|-
|AZ P9260 1gal.
|AZ P9260 1gal.
|AZ® 9260 i-line / Broadband Photoresist
|AZ® 9260 i-line / Broadband Photoresist
|INTEGRATED MICRO MATERIALS
|INTEGRATED MICRO MATERIALS
|Photoresist, PR
|-
|-
|AZnLOF 2020, 1 gal.
|AZnLOF 2020, 1 gal.
|AZ nLoF 2020 NEGATIVE TONE LIFT-OFF PHOTORESIST
|AZ nLoF 2020 NEGATIVE TONE LIFT-OFF PHOTORESIST
|INTEGRATED MICRO MATERIALS
|INTEGRATED MICRO MATERIALS
|Photoresist, PR
|-
|-
|AZnLOF 2035, 1 qt.
|AZnLOF 2035, 1 qt.
|AZ Nlof 2035 NEGATIVE TONE LIFT-OFF PHOTORESIST
|AZ Nlof 2035 NEGATIVE TONE LIFT-OFF PHOTORESIST
|INTEGRATED MICRO MATERIALS
|INTEGRATED MICRO MATERIALS
|Photoresist, PR
|-
|-
|AZnLOF 2070, 1 qt
|AZnLOF 2070, 1 qt
|AZ NLOF2070 NEGATIVE TONE LIFT-OFF PHOTORESIST
|AZ NLOF2070 NEGATIVE TONE LIFT-OFF PHOTORESIST
|INTEGRATED MICRO MATERIALS
|INTEGRATED MICRO MATERIALS
|Photoresist, PR
|-
|-
|NR9-1000PY
|NR9-1000PY
|Negative Resist NR9-1000PY
|Negative Resist NR9-1000PY
|Futurrex, Inc.
|Futurrex, Inc.
|Photoresist, PR
|-
|-
|NR9-3000PY
|NR9-3000PY
|Negative Resist NR9-3000PY
|Negative Resist NR9-3000PY
|Futurrex, Inc.
|Futurrex, Inc.
|Photoresist, PR
|-
|-
|NR9-6000PY
|NR9-6000PY
|Negative Resist NR9-6000PY
|Negative Resist NR9-6000PY
|Futurrex, Inc.
|Futurrex, Inc.
|Photoresist, PR
|-
|-
|LOL 2000, 1 qt.
|LOL 2000, 1 qt.
|LOL 2000 -1 QT
|LOL 2000 -1 QT
|MICROCHEM CORP.
|MICROCHEM CORP.
|Photoresist, PR Underlayer
|-
|-
|AZ nLOF P5510 photoresist, 1 gallon
|AZ nLOF P5510 photoresist, 1 gallon
|AZ nLoF 5510 NEGATIVE TONE LIFT-OFF PHOTORESIST.
|AZ nLoF 5510 NEGATIVE TONE LIFT-OFF PHOTORESIST.
|INTEGRATED MICRO MATERIALS
|INTEGRATED MICRO MATERIALS
|Photoresist, PR
|-
|-
|THMR-IP3600 HP D
|THMR-IP3600 HP D
|THMR-IP3600 HP
|THMR-IP3600 HP
|TOK AMERICA, INC.
|TOK AMERICA, INC.
|Photoresist, PR
|-
|-
|XHRIC-11 1 LITER
|XHRIC-11 1 LITER
|XHRIC-11 1 LITER
|XHRIC-11 1 LITER
|BREWER SCIENCE, INC.
|BREWER SCIENCE, INC.
|Photoresist, PR, BARC
|-
|MR-I 7020, Imprint Resist 250ml
|MRT - mr-I 7020E - 250ml GLASS
|MICROCHEM CORP.
|-
|-
|PMGI, SF 3, 500 ml
|PMGI, SF 3, 500 ml
|PMGI SF 3 - 500ml Glass
|PMGI SF 3 - 500ml Glass
|MICROCHEM CORP.
|MICROCHEM CORP.
|Photoresist, PR
|-
|-
|PMGI, SF 5, 500 ml
|PMGI, SF 5, 500 ml
|PMGI SF 5 - 500ml Glass
|PMGI SF 5 - 500ml Glass
|MICROCHEM CORP.
|MICROCHEM CORP.
|Photoresist, PR
|-
|-
|PMGI, SF 8, 500 ml
|PMGI, SF 8, 500 ml
|PMGI SF-8, glass 500ml
|PMGI SF-8, glass 500ml
|MICROCHEM CORP.
|MICROCHEM CORP.
|Photoresist, PR
|-
|-
|PMGI, SF11, 500 ml
|PMGI, SF11, 500 ml
|PMGI SF 11 - 500ML GLASS
|PMGI SF 11 - 500ML GLASS
|MICROCHEM CORP.
|MICROCHEM CORP.
|Photoresist, PR
|-
|-
|PMGI, SF15, 500 ml
|PMGI, SF15, 500 ml
|PMGI SF 15 - 500ML GLASS
|PMGI SF 15 - 500ML GLASS
|MICROCHEM CORP.
|MICROCHEM CORP.
|Photoresist, PR
|-
|-
|Dow Advanced Electronic, 4024-40, photo BCB
|Dow Advanced Electronic, 4024-40, photo BCB
|CYCLOTENE* 4024 - 40 / 0.95 LITERS (BCB)
|CYCLOTENE* 4024 - 40 / 0.95 LITERS (BCB)
|MICROCHEM CORP.
|MICROCHEM CORP.
|Photo-BCB
|-
|-
|Cyclotene 3022-46
|Cyclotene 3022-46
|CYCLOTENE* 3022-46
|CYCLOTENE* 3022-46
|MICROCHEM CORP.
|MICROCHEM CORP.
|BCB
|-
|-
|AP3000 BCB Adhesion Promoter, gall.
|AP3000 BCB Adhesion Promoter, gall.
|ADHESION PROMOTER AP3000
|ADHESION PROMOTER AP3000
|MICROCHEM CORP.
|MICROCHEM CORP.
|BCB Adhesion Promoter
|-
|-
|Omnicoat, adhesion promoter for SU-8
|Omnicoat, adhesion promoter for SU-8
|OMNICOAT - 500ML GLASS
|OMNICOAT - 500ML GLASS
|MICROCHEM CORP.
|MICROCHEM CORP.
|Resist
|-
|-
|HMDS, (Fineline adhes.), 1 bt.
|HMDS, (Fineline adhes.), 1 bt.
|MPHP-PT MICROPRIMER HIGH PURITY
|MPHP-PT MICROPRIMER HIGH PURITY
|SHIN-ETSU MICROSI, INC.
|SHIN-ETSU MICROSI, INC.
|Photoresist Adhesion Promoter
|-
|-
|Tergitol
|Tergitol
|Spectrum Chemical Manufacturing Corporation TERGITOL NP-10 SURFCTNT 500ML   T1273500ML
|Spectrum Chemical Manufacturing Corporation TERGITOL NP-10 SURFCTNT 500ML   T1273500ML
|FISHER SCIENTIFIC
|FISHER SCIENTIFIC
|Detergent
|-
|-
|SU-8 2005 Photoresist
|SU-8 2005 Photoresist
|SU-8 2005 - 500ml GLASS
|SU-8 2005 - 500ml GLASS
|MICROCHEM CORP.
|MICROCHEM CORP.
|Photoresist, PR
|-
|-
|SU-8 2010 Photoresist
|SU-8 2010 Photoresist
|SU-8 2010 - 500ml GLASS
|SU-8 2010 - 500ml GLASS
|MICROCHEM CORP.
|MICROCHEM CORP.
|Photoresist, PR
|-
|-
|SU-8 2015 Photoresist
|SU-8 2015 Photoresist
|SU-8 2015 - 500ml GLASS
|SU-8 2015 - 500ml GLASS
|MICROCHEM CORP.
|MICROCHEM CORP.
|Photoresist, PR
|-
|-
|SU-8 2075 Photoresist
|SU-8 2075 Photoresist
|SU-8 2075 - 500ml Glass Resist
|SU-8 2075 - 500ml Glass Resist
|MICROCHEM CORP.
|MICROCHEM CORP.
|Photoresist, PR
|-
|-
|UV-6 0.8 Photoresist
|UV-6 0.8 Photoresist
|UV6-0.8
|UV6-0.8
|MICROCHEM CORP.
|MICROCHEM CORP.
|Photoresist, PR
|-
|-
|DUV42P-6
|DUV42P-6
|DUV42P-6
|DUV42P-6
|BREWER SCIENCE, INC
|BREWER SCIENCE, INC
|Photoresist, PR, BARC
|-
|-
|Honeywell 512B spin-on-glass, 125 ml.
|Honeywell 512B spin-on-glass, 125 ml.
|ACCUGLASS 512B SPIN-ON GLASS
|ACCUGLASS 512B SPIN-ON GLASS
|HONEYWELL ANALYTICS INC.
|HONEYWELL ANALYTICS INC.
|SOG
|-
|-
|UVN 30-0.8L (UVN 2300-0.5)
|UVN 30-0.8L (UVN 2300-0.5)
|UVN 30-0.8L-1 GL NOWPAK
|UVN 30-0.8L-1 GL NOWPAK
|MICROCHEM CORP.
|MICROCHEM CORP.
|Photoresist, PR
|-
|-
|Brewer Science DS-K101-304, 1 gal bt.
|Brewer Science DS-K101-304, 1 gal bt.
|ARC DS-K101-304, 1 LITER
|ARC DS-K101-304, 1 LITER
|BREWER SCIENCE, INC.
|BREWER SCIENCE, INC.
|Photoresist, PR, BARC
|-
|-
|UV 210GS-0.3, 1 gal. bt.
|UV 210GS-0.3, 1 gal. bt.
|UV 21OGS-0.3 - 1 GL NOWPAK
|UV 210GS-0.3 - 1 GL NOWPAK
|MICROCHEM CORP.
|MICROCHEM CORP.
|Photoresist, PR
|-
|-
|mr-UV Cur 21 100 nm, 100ml.
|mr-UV Cur 21 100 nm, 100ml.
|MRT-mr-UV Cur 21, 100nm - 100ml Glass
|MRT-mr-UV Cur 21, 100nm - 100ml Glass
|MICROCHEM CORP.
|MICROCHEM CORP.
|Nanoimprint Resist
|-
|-
|Santovac 5P
|Santovac 5P
|Santovac 5P Ultra Polyphenyl Ether Pump Fluid
|Santovac 5P Ultra Polyphenyl Ether Pump Fluid
|KURT J LESKER
|KURT J LESKER
|Oil
|-
|-
|SF1 Polishing Fluid
|SF1 Polishing Fluid
|SF1 Polishing Fluid
|SF1 Polishing Fluid
|LOGITECH LIMITED
|LOGITECH LIMITED
|CMP Slurry
|-
|CrystalBond Wax
|Crystalbond 509 (Clear Color) Mounting Adhesive, Stick (round shape)
|
|Mounting wax, ~135°C melting point, acetone soluble.
|}
|}

Latest revision as of 23:44, 7 April 2026

You can sort the following table using the ↑ / ↓ buttons in the title row. Your browser's "Find" ⌘-F function also works.

CHEMICAL DESCRIPTION VENDOR Other Names/Notes
Acetone, 4L, 4 bt = 1 cs ACETONE ACS SAFE-COTE 4L Percent Purity ≥99.5% FISHER SCIENTIFIC ACE
Propanol, 4L, 4 bt = 1 cs 2-PROPANOL OPTIM AGRADE Percent Purity ≥99.9% FISHER SCIENTIFIC ISO, IPA, Isopropanol
Ethanol DEHYDRATED ALCOHOL, 200 PROOF, UNDENATURED, USP GRADE- 4LGLASS SPECTRUM CHEMICALS & LAB
Methanol, 4L, 4 bt = 1 cs METHANOL OPTIMA GRADE 4L Percent Purity ≥99.9% FISHER SCIENTIFIC
Toluene, 4 L TOLUENE OPTIMA GRADE 4L Percent Purity ≥99.8% FISHER SCIENTIFIC
Ethylene Glycol ETHYLENE GLYCOL LABORATORY GRADE FISHER SCIENTIFIC
Amyl Acetate, 4L bottle AMYL ACETATE LABORATORY GRADE 4L FISHER SCIENTIFIC
MIBK, 4L bottle Methyl iso-Butyl Ketone (Certified ACS), Grade Certified ACS Reagent FISHER SCIENTIFIC
Chloroform, 2.5 L Chloroform, 99+%, Acros Organics FISHER SCIENTIFIC
Xylenes, 1 liter XYLENES ACS 4L Percent Purity ≥98.5% FISHER SCIENTIFIC
T1100 BCB rinse solvent RINSE T1100 4 LITER GLASS BOTTLE MICROCHEM CORP.
Nitric, 500ml. NITRIC ACID IND SAFECOTE 2,5L, Assay Percent Range 70% FISHER SCIENTIFIC
Sulfuric, 2.5 L SULFURIC AC 21/2L IND SAFECOTE Assay Percent Range 95.0 to 98.0 w/w % FISHER SCIENTIFIC H2SO4
O-Phosphoric, 2.5 L O-PHOSPHORIC ACID Percent Purity ≥85.0% (w/w) FISHER SCIENTIFIC H3PO4
Citric acid, liquid, 1.0 M, 1L CITRIC ACID, 1.00 Molar FISHER SCIENTIFIC C6H8O7, solution
50/50 w/w Citric Acid Monohydrate in Water PREMIX CITRIC ACID CAW 1:1 TRANSENE COMPANY, INC. C6H8O7, solution
Citric acid, granular, monohydrate, 3 kg CITRIC ACID GRAN CERT ACS 3KG Percent Purity 99.0 to 102.0% FISHER SCIENTIFIC C6H8O7, powder
Acetic, 2.5L ACETIC ACID GLACIAL ACS 2.5L IND SAF-CT Assay Percent Range: ≥99.7% w/w FISHER SCIENTIFIC
Hydrochloric, 2.5L HYDROCHLORIC ACID Percent Purity 36.5 to 38.0% (w/w) FISHER SCIENTIFIC HCl
Hydrofluoric, 49%, 500 Ml HYDROFLUORIC ACID RGT 500ML Assay (HF) 48 - 51% VWR INTERNATIONAL HF
Hydrofluoric, Buffered HF, 1 gal BUFFER-HF TRANSENE COMPANY, INC. BHF, "Buffered oxide etch"

4-8% HF

Hydrobromic, 500 mL HYDROBROMIC ACID 48% CERT ACS 500ML Percent Purity 47.0 to 49.0% FISHER SCIENTIFIC HBr
Chrome mask etchant, 1 qt CHROMIUM ETCHANT 1020 TRANSENE COMPANY, INC.
Aluminum etchant, A, 1 qt ALUMINUM ETCHANT TYPE A TRANSENE COMPANY, INC.
Aluminum etchant, D, 1 qt ALUMINUM ETCHANT TYPE D TRANSENE COMPANY, INC.
Gold etchant, TFA, 1 qt GOLD ETCHANT TFA TRANSENE COMPANY, INC.
Nickel etchant, TFB, 1 qt. NICKEL ETCH TFB TRANSENE COMPANY, INC.
Titanium etchant, TFTN TITANIUM ETCHANT TFTN TRANSENE COMPANY, INC.
Nanostrip KMG-Nanostrip INTEGRATED MICRO MATERIALS
Oxalic Acid OXALIC ACID CERTIF ACS 500G Percent Purity 99.5 to 102.5% FISHER SCIENTIFIC
Formic Acid FORMIC ACID 2.5LT 98% (ACS) FISHER SCIENTIFIC
Chromic Acid (Chromium Trioxide) Chromium Trioxide (Crystalline/Certified ACS) Percent Purity ≥98.0% FISHER SCIENTIFIC CrO3
Ammonium hydroxide, 2.5 L AMMONIUM HYDROXIDE ACS Assay Percent Range: 28.0 to 30.0 w/w % FISHER SCIENTIFIC NH4OH
Ammonium sulfide, 500 mL AMMONIUM SULFIDE SOLUTION Assay Percent Range 20 to 24% (aqueous) FISHER SCIENTIFIC (NH4)2S
Sodium hydroxide, 1L SODIUM HYDROX SOL 50% CERT 1L Percent Purity Inclusive between 50% FISHER SCIENTIFIC NaOH
Potassium hydroxide, 43. POT HYDROX SOL 45% CERT 4L Concentration or Composition (by Analyte or Components) 45% FISHER SCIENTIFIC KOH
Hydrogen peroxide, 500 mL HYDROGEN PEROXIDE 30% Percent Purity 30.0 to 32.0% FISHER SCIENTIFIC H2O2
Hydrogen peroxide, 1 gal HYDROGEN PEROXIDE 30% Percent Purity 30.0 to 32.0% FISHER SCIENTIFIC H2O2
TMAH, 25%, per liter TETRAMETHYLAMMONIUM HYDROXIDE, 25% TRANSENE COMPANY, INC.
Saturated Bromine Water (SBW), 1L BROMINE WATER RGT 500ML Percent Purity ≥99.5% FISHER SCIENTIFIC Br2 : H2O
AZ400k developer, concentrated, 1 gal AZ 400K CONCENTRATE PHOTORESIST DEVELOPER INTEGRATED MICRO MATERIALS
AZ400k developer, 1:4 diluted, 1 gal AZ 400k 1:4 PHOTORESIST DEVELOPER INTEGRATED MICRO MATERIALS Pre-diluted
AZ 726 MIF developer, 1 gal AZ 726 MIF DEVELOPER INTEGRATED MICRO MATERIALS
AZ NMP Rinse & Photoresist Stripper AZ® NMP Rinse & Photoresist Stripper INTEGRATED MICRO MATERIALS
AZ 300 T, stripper, 1 gal. AZ 300T STRIPPER INTEGRATED MICRO MATERIALS
MicroChem 101A Developer, 1 gal 101A DEVELOPER MICROCHEM CORP. SAL 101A, XP 101A
AZ 300 MIF Developer AZ 300 MIF DEVELOPER INTEGRATED MICRO MATERIALS
SU-8 Developer SU-8 DEVELOPER - 4 X 4L MICROCHEM CORP.
DS2100 BCB Developer DEVELOPER DS2100 MICROCHEM CORP. BCB Developer
EC 11 EC SOLVENT 11 - 4 GL CS MICROCHEM CORP.
AZ EBR AZ EBR EDGE BEAD REMOVER INTEGRATED MICRO MATERIALS
KwikStrip, gallon size AZ KWIK STRIP PHOTORESIST STRIPPER INTEGRATED MICRO MATERIALS
Remover PG, SU-8 stripper REMOVER PG - 4 X 4L MICROCHEM CORP.
SPR 955 CM-0.9, 1 Gal. SPR 955CM-0.9 - 1 GL MICROCHEM CORP. Photoresist, PR
SPR 955 CM-1.8, 1 Gal. SPR 955CM-1.8 - 1 GL MICROCHEM CORP. Photoresist, PR
SPR 220-3.0, 1 gal. SPR 220-3.0 P.R. 1GL MICROCHEM CORP. Photoresist, PR
SPR 220-7.0, 1 GAL, SPR 220-7.0 P.R. 1GL MICROCHEM CORP. Photoresist, PR
CEM-365 IS, for stepper, 1 pint. CEM365IS-QT SHIN-ETSU MICROSI, INC. Photoresist, PR contrast enhancer
OCG 825-35CS OCG 825 35CS 1X1 GALLON GLASS GALLADE CHEMICAL Photoresist, PR
AZ P4110 1Qt. AZ P4110 PHOTORESIST INTEGRATED MICRO MATERIALS Photoresist, PR
AZ P4210  1Qt. AZ P4210 G-LINE/BROADBAND PHOTORESIST INTEGRATED MICRO MATERIALS Photoresist, PR
AZ P4330 RS  1QT. AZ P4330-RS INTEGRATED MICRO MATERIALS Photoresist, PR
AZ 5214-EIR  1QT. AZ 5214-E IR PHOTORESIST INTEGRATED MICRO MATERIALS Photoresist, PR
AZ P4620 1QT AZP4620-1Q INTEGRATED MICRO MATERIALS Photoresist, PR
AZ P9260 1gal. AZ® 9260 i-line / Broadband Photoresist INTEGRATED MICRO MATERIALS Photoresist, PR
AZnLOF 2020, 1 gal. AZ nLoF 2020 NEGATIVE TONE LIFT-OFF PHOTORESIST INTEGRATED MICRO MATERIALS Photoresist, PR
AZnLOF 2035, 1 qt. AZ Nlof 2035 NEGATIVE TONE LIFT-OFF PHOTORESIST INTEGRATED MICRO MATERIALS Photoresist, PR
AZnLOF 2070, 1 qt AZ NLOF2070 NEGATIVE TONE LIFT-OFF PHOTORESIST INTEGRATED MICRO MATERIALS Photoresist, PR
NR9-1000PY Negative Resist NR9-1000PY Futurrex, Inc. Photoresist, PR
NR9-3000PY Negative Resist NR9-3000PY Futurrex, Inc. Photoresist, PR
NR9-6000PY Negative Resist NR9-6000PY Futurrex, Inc. Photoresist, PR
LOL 2000, 1 qt. LOL 2000 -1 QT MICROCHEM CORP. Photoresist, PR Underlayer
AZ nLOF P5510 photoresist, 1 gallon AZ nLoF 5510 NEGATIVE TONE LIFT-OFF PHOTORESIST. INTEGRATED MICRO MATERIALS Photoresist, PR
THMR-IP3600 HP D THMR-IP3600 HP TOK AMERICA, INC. Photoresist, PR
XHRIC-11 1 LITER XHRIC-11 1 LITER BREWER SCIENCE, INC. Photoresist, PR, BARC
PMGI, SF 3, 500 ml PMGI SF 3 - 500ml Glass MICROCHEM CORP. Photoresist, PR
PMGI, SF 5, 500 ml PMGI SF 5 - 500ml Glass MICROCHEM CORP. Photoresist, PR
PMGI, SF 8, 500 ml PMGI SF-8, glass 500ml MICROCHEM CORP. Photoresist, PR
PMGI, SF11, 500 ml PMGI SF 11 - 500ML GLASS MICROCHEM CORP. Photoresist, PR
PMGI, SF15, 500 ml PMGI SF 15 - 500ML GLASS MICROCHEM CORP. Photoresist, PR
Dow Advanced Electronic, 4024-40, photo BCB CYCLOTENE* 4024 - 40 / 0.95 LITERS (BCB) MICROCHEM CORP. Photo-BCB
Cyclotene 3022-46 CYCLOTENE* 3022-46 MICROCHEM CORP. BCB
AP3000 BCB Adhesion Promoter, gall. ADHESION PROMOTER AP3000 MICROCHEM CORP. BCB Adhesion Promoter
Omnicoat, adhesion promoter for SU-8 OMNICOAT - 500ML GLASS MICROCHEM CORP. Resist
HMDS, (Fineline adhes.), 1 bt. MPHP-PT MICROPRIMER HIGH PURITY SHIN-ETSU MICROSI, INC. Photoresist Adhesion Promoter
Tergitol Spectrum Chemical Manufacturing Corporation TERGITOL NP-10 SURFCTNT 500ML   T1273500ML FISHER SCIENTIFIC Detergent
SU-8 2005 Photoresist SU-8 2005 - 500ml GLASS MICROCHEM CORP. Photoresist, PR
SU-8 2010 Photoresist SU-8 2010 - 500ml GLASS MICROCHEM CORP. Photoresist, PR
SU-8 2015 Photoresist SU-8 2015 - 500ml GLASS MICROCHEM CORP. Photoresist, PR
SU-8 2075 Photoresist SU-8 2075 - 500ml Glass Resist MICROCHEM CORP. Photoresist, PR
UV-6 0.8 Photoresist UV6-0.8 MICROCHEM CORP. Photoresist, PR
DUV42P-6 DUV42P-6 BREWER SCIENCE, INC Photoresist, PR, BARC
Honeywell 512B spin-on-glass, 125 ml. ACCUGLASS 512B SPIN-ON GLASS HONEYWELL ANALYTICS INC. SOG
UVN 30-0.8L (UVN 2300-0.5) UVN 30-0.8L-1 GL NOWPAK MICROCHEM CORP. Photoresist, PR
Brewer Science DS-K101-304, 1 gal bt. ARC DS-K101-304, 1 LITER BREWER SCIENCE, INC. Photoresist, PR, BARC
UV 210GS-0.3, 1 gal. bt. UV 210GS-0.3 - 1 GL NOWPAK MICROCHEM CORP. Photoresist, PR
mr-UV Cur 21 100 nm, 100ml. MRT-mr-UV Cur 21, 100nm - 100ml Glass MICROCHEM CORP. Nanoimprint Resist
Santovac 5P Santovac 5P Ultra Polyphenyl Ether Pump Fluid KURT J LESKER Oil
SF1 Polishing Fluid SF1 Polishing Fluid LOGITECH LIMITED CMP Slurry
CrystalBond Wax Crystalbond 509 (Clear Color) Mounting Adhesive, Stick (round shape) Mounting wax, ~135°C melting point, acetone soluble.