Template:Announcements: Difference between revisions

From UCSB Nanofab Wiki
Jump to navigation Jump to search
(added GCA Autostep service (Millerski))
(DSX up)
 
(377 intermediate revisions by 7 users not shown)
Line 1: Line 1:
<startfeed />
<startfeed />
=====PECVD#2 will remain down overnight=====
<!--feedBurner name="UCSBNanofab-Announcements" /-->
Unfortunately PECVD2 will remain down overnight.
<!-- Description of the RSS feed -->
'''''Important Announcements'''''
----
<!--
SEE THE BOTTOM OF THIS PAGE FOR DETAILED INSTRUCTIONS ON ADDING NEWS ITEMS.


The heater is unable to keep up with the setpoint while running.
In order for your post to show up correctly, you need to:
>> Use FIVE equal-signs for the Title's heading level. eg.: ===== my post =====
>> Use two slashes // and FOUR tilde's to insert your signature at the end of your post: //~~~~
-->
<!---------------------------------------------->
<!------------- Equipment Status ---------------->


Don and I replaced the heater controller without luck.
===== GCA AutoStep Service =====
Stepper #2 (GCA AutoStep200) will be unavailable for use while maintenance tasks are performed on the following dates:


I am cooling down the chamber overnight and we will look into the heater coil in the morning.
9-28-22 at 8:00am to 9-29-22 at 5:00pm
//[[User:Mehalana v|Vraj Mehalana]] 03:31, 25 February 2025 (UTC)


=====Olympus DSX Microscope: UP=====
// [[User:John d|John d]] 10:15, 1 September 2022 (PDT)
I have installed a new head and tested it with no problems. Please let me know if you have any questions.
-- Tony Bosch
// [[User:John_d|Demis D. John]] 04:57, 25 February 2025 (UTC)


===== MLA 150 Service & Software Revision =====
=====RIE #5 Down=====
RIE #5 will be down Monday March 13th through the end of Wednesday March 15th for maintenance.


If we complete the job early we will send a follow-up email releasing the system.
The MLA will be down beginning the evening of Monday October 3rd and should be back up sometime Friday October 7th.
// [[User:Sawyer l|L Sawyer]] 13:32, 31 August 2022 (PDT)


//[[User:Mehalana v|Vraj Mehalana]] 09:46, 21 February 2025 (UTC)
===== Chlorine gasses available =====
All Cl2 processes are now available for your use.


=====Stepper #3 (ASML DUV) - Maint moved to March 3rd=====
// [[User:John d|John d]] 10:57, 31 August 2022 (PDT)
We have postponed the Periodic Maintenance (PM) to the week of Monday March 3rd.
Please plan your work accordingly.
// [[User:John_d|Demis D. John]] 19:44, 4 February 2025 (UTC)


===== ASML Up; Network status =====
=====Oxford ALD+Ion Mill: UP=====
The tool now runs all process temperatures (120-300c).
--Bill Millerski
UCSB
//[[User:John_d|Demis D. John]] 19:48, 4 February 2025 (UTC)


=====New Gowns: Toolbelts purchases=====
We are running a newer computer;
We are required to switch to new gowns in January. The new gowns won’t have pockets, but you are allowed to purchase cleanroom tool belts. Please ask staff for which tool belts you can purchase.
Nanofiles sync & JobCreator functionality will be restored in the next few weeks.


Two vendors for cleanroom belts we are using are listed here, you may request others:
// [[User:John d|John d]] 09:00, 22 July 2022 (PDT)
* [https://www.terrauniversal.com/tool-belt-pocket-49in-waist-white-altessa-grid-uniform-technology-4954-60a.html Uniform Technology Tool Belt] - note the waist size, the 49” belt fits up to ~36-38” waist.
* [https://www.fishersci.com/shop/products/cleanroom-fannypack-1-ea-white/NC0723118?searchHijack=true&searchTerm=cleanroom-fannypack-1-ea-white&searchType=Rapid&matchedCatNo=NC0723118 HiTEC Fannypack]


// [[User:John_d|Demis D. John]] 03:34, 3 January 2025 (UTC)
===== Face-Masks Optional as of June 13 =====
You are not required to wear a mask in UC buildings at this time. You are also not required to wear a mask in the Nanofab if desired.


=====Suss SB6-8E=====
We will still provide masks at the metal table in front of the cleanroom entry.
We found a blown resistor (and a questionable op amp) on one of the boards that contains the z-axis motor circuit. However, we still cannot get the tool to initialize. Next we will try swapping out the hard drive again and run some more tests.
See the [https://t.e2ma.net/webview/be2nag/25634e9f535619ce1f4eb976598e7268 UCSB announcement at this link].


I will send out an update once we have one.
See the full policies at '''[[COVID-19_User_Policies]]'''
-Aidan
// [[User:John d|John d]] 11:20, 13 June 2022 (PDT)
// [[User:John_d|Demis D. John]] 00:35, 8 December 2024 (UTC)


===== New EBL Rates =====
=====ICP1 Down=====
The board we were waiting on arrived, but it did not resolve the tool issue. We are working with Panasonic on the next steps.
Effective Dec.1, 2021, all of our electron beam lithography rates are lowered. The new rates are as follows:
//[[User:Mehalana v|Vraj Mehalana]] 14:17, 1 March 2024 (PST)


<!--
Industrial Users: $405/hour
SEE THE BOTTOM OF THIS PAGE FOR DETAILED INSTRUCTIONS ON ADDING NEWS ITEMS.

In order for your post to show up correctly, you need to:
UC Academic Users: $126/hour
>> Use FIVE equal-signs for the Title's heading level. eg.: ===== my post =====

>> Use two slashes // and FOUR tilde's to insert your signature at the end of your post: //~~~~
Non-UC Academic Users: $150/hour
-->

<!---------DO NOT EDIT BELOW THIS LINE----------->
UCSB CNSI Incubator USers: $260/hour

//[[User:Thibeault|Thibeault]] 12:21, 9 December 2021 (PST)

<!---------- end of Equipment Status ------------>
<!---------------------------------------------->
<endfeed />
<endfeed />
<noinclude>[[Category:Templates]]</noinclude>
<noinclude>[[Category:Templates]]</noinclude>
<!--------------------------------------------
<!--------------------------------------------
====== HOW TO ADD ITEMS ======




====== HOW TO ADD NEWS ITEMS ======

* You can copy/paste the example below for a new news item.
* You can copy/paste the example below for a new news item.
* Use level 5 heading for each item (5 equal signs surrounding the title) - they will show up as separate RSS items this way. (This looks best on the Wiki homepage)
* Use level 5 heading for each item (5 equal signs surrounding the title) - they will show up as separate RSS items this way. (This looks best on the Wiki homepage)
* You must add a user signature at the end of each post via four tildes: ~~~~. Required for the RSS plugin to determine the timestamp, or else post goes to the end of the RSS feed.
* You must add a user signature at the end of each post via four tildes: [[User:Silva|Silva]] 13:26, 4 February 2023 (PST). Required for the RSS plugin to determine the timestamp, or else post goes to the end of the RSS feed.
* Use double-slash: // at start of new lines - makes display on the Samsung Display look a lot better, since it strips newlines.
* Use double-slash: // at start of new lines - makes display on the Samsung Display look a lot better, since it strips newlines.
* Optional: After saving the page, delete the name after the two dashes "--" and delete the "[[(talk)...]]" link.
* Optional: After saving the page, delete the name after the two dashes "--" and delete the "[[(talk)...]]" link.
Line 86: Line 79:
===== NanoFab making LN2 icecream =====
===== NanoFab making LN2 icecream =====
Tomorrow the NanoFab will be serving liquid nitrogen ice cream.
Tomorrow the NanoFab will be serving liquid nitrogen ice cream.
// [[User:Silva|Silva]] 13:26, 4 February 2023 (PST)
// ~~~~


************* (end of example) **************
************* (end of example) **************
The ~~~~ will be replaced with your username & timestamp after you submit the post.
The [[User:Silva|Silva]] 13:26, 4 February 2023 (PST) will be replaced with your username & timestamp after you submit the post.
---------------------------------------------->
---------------------------------------------->

Latest revision as of 04:57, 25 February 2025

PECVD#2 will remain down overnight

Unfortunately PECVD2 will remain down overnight.

The heater is unable to keep up with the setpoint while running.

Don and I replaced the heater controller without luck.

I am cooling down the chamber overnight and we will look into the heater coil in the morning. //Vraj Mehalana 03:31, 25 February 2025 (UTC)

Olympus DSX Microscope: UP

I have installed a new head and tested it with no problems. Please let me know if you have any questions. -- Tony Bosch // Demis D. John 04:57, 25 February 2025 (UTC)

RIE #5 Down

RIE #5 will be down Monday March 13th through the end of Wednesday March 15th for maintenance.

If we complete the job early we will send a follow-up email releasing the system.

//Vraj Mehalana 09:46, 21 February 2025 (UTC)

Stepper #3 (ASML DUV) - Maint moved to March 3rd

We have postponed the Periodic Maintenance (PM) to the week of Monday March 3rd. Please plan your work accordingly. // Demis D. John 19:44, 4 February 2025 (UTC)

Oxford ALD+Ion Mill: UP

The tool now runs all process temperatures (120-300c). --Bill Millerski UCSB //Demis D. John 19:48, 4 February 2025 (UTC)

New Gowns: Toolbelts purchases

We are required to switch to new gowns in January. The new gowns won’t have pockets, but you are allowed to purchase cleanroom tool belts. Please ask staff for which tool belts you can purchase.

Two vendors for cleanroom belts we are using are listed here, you may request others:

// Demis D. John 03:34, 3 January 2025 (UTC)

Suss SB6-8E

We found a blown resistor (and a questionable op amp) on one of the boards that contains the z-axis motor circuit. However, we still cannot get the tool to initialize. Next we will try swapping out the hard drive again and run some more tests.

I will send out an update once we have one. -Aidan // Demis D. John 00:35, 8 December 2024 (UTC)

ICP1 Down