MediaWiki:Common.css: Difference between revisions

From UCSB Nanofab Wiki
Jump to navigation Jump to search
Content deleted Content added
Zwarburg (talk | contribs)
No edit summary
bolding Protofab text in sidebar
 
(34 intermediate revisions by 4 users not shown)
Line 1: Line 1:
/* Site-wide mods */
/** Collapsible tables *********************************************************

⚫
*
/* disable "discussion" link on every page */
* Description: Allows tables to be collapsed, showing only the header. See
li#ca-talk { display:none!important; }
* http://www.mediawiki.org/wiki/Manual:Collapsible_tables.

* Maintainers: [[en:User:R. Koot]]
/*-------------------------------*/
⚫
*/


table.collapsed tr.collapsible {

⚫
display: none;
/* MediaWiki:Sidebar CSS rules */

/* remove the first Section title causing a blank space */
div#p-InvisibleMenu {
⚫
display:none!important;
}
}

/* targets the div holding the logo */
.collapseButton { /* 'show'/'hide' buttons created dynamically by the */
div#p-logo {
float: right; /* CollapsibleTables JavaScript in [[MediaWiki:Common.js]] */
/* CSS goes here */
font-weight: normal; /* are styled here so they can be customised. */
text-align: right;
width: auto;
}
}

/* targets the link inside the logo div */
div#plogo a.mw-wiki-logo {

}


/* Bold specific sidebar items: */
li#n-Lab-Rules a {
font-weight: bold;
}

⚫
/*
li#n-COVID-19-Protocols a {
font-weight: bold;
}
⚫
*/


/* Bold specific sidebar items: */
li#n-Protofab a {
font-weight: bold;
}



/*-----------------------------------*/
/* Sidebar title elements */

/* THESE ARE OVERRIDDEN BY ANOTHER RULE `@media screen #mw-panel .portal {}` */

h3#p-navigation-label {

}
h3#p-Equipment-label {
}
h3#p-Recipes_and_Data-label {
}
h3#p-Facility_Data-label {
}
h3#p-Editing_Tools-label {
}
h3#p-p-tb-label {
}

/* For the spacing between elements, you want to target all li elements inside of the section divs and increase the padding top and bottom on those elements */
div#p-navigation li {

}

div#p-Equipment li {


}

/* etc... */

Latest revision as of 19:41, 9 September 2026

/* Site-wide mods */

/* disable "discussion" link on every page */
li#ca-talk { display:none!important; }

/*-------------------------------*/



/* MediaWiki:Sidebar CSS rules */

/* remove the first Section title causing a blank space */
div#p-InvisibleMenu {
display:none!important;
}

/* targets the div holding the logo */
div#p-logo {
    /* CSS goes here */
}

/* targets the link inside the logo div */
div#plogo a.mw-wiki-logo {

}


/* Bold specific sidebar items: */
li#n-Lab-Rules a {
   font-weight: bold;
}

/*
li#n-COVID-19-Protocols a {
   font-weight: bold;
}
*/


/* Bold specific sidebar items: */
li#n-Protofab a {
   font-weight: bold;
}



/*-----------------------------------*/
/* Sidebar title elements */

/* THESE ARE OVERRIDDEN BY ANOTHER RULE `@media screen #mw-panel .portal {}`  */

h3#p-navigation-label {

}
h3#p-Equipment-label {
}
h3#p-Recipes_and_Data-label {
    
}
h3#p-Facility_Data-label {
    
}
h3#p-Editing_Tools-label {
    
}
h3#p-p-tb-label {
    
}

/* For the spacing between elements, you want to target all li elements inside of the section divs and increase the padding top and bottom on those elements */
div#p-navigation li {

}

div#p-Equipment li {


}

/* etc... */