Editing Tutorials: Difference between revisions

From UCSB Nanofab Wiki
Jump to navigation Jump to search
No edit summary
Line 34: Line 34:
[[image:Watch2.png|thumb|none|400px|]]
[[image:Watch2.png|thumb|none|400px|]]


You can also set it up so that you will recieve an e-mail any time one of the pages on your watchlist is changed (by someone other then yourself). I would also HIGHLY recommend doing this. These emails will come from NanofabWiki@ece.ucsb.edu so you can setup a filter and put all these e-mails in one folder.
You can also set it up so that you will recieve an e-mail any time one of the pages on your watchlist is changed (by someone other then yourself). I would also HIGHLY recommend doing this. These emails will come from NanofabWiki@ece.ucsb.edu so you can setup a filter and put all these e-mails in one folder. You will only receive one e-mail per page between visits. In other words if 10 people make changes back to back. You will only get ONE e-mail notifying you that a change has been made, not 10 e-mails. As soon as you view the page form your account, that resets so any changes made after you view it will result in another, single e-mail.


To set this up go to your preferences by click on the "'''my preferences'''".
To set this up go to your preferences by click on the "'''my preferences'''".

Revision as of 23:08, 16 July 2012

Editing Restrictions

To prevent unauthorized editing on the site, I have setup 4 different user groups. These restrictions only pertain to EDITING. (For the moment the site is locked from viewing as well. That will change once the site is ready to launch).

1) Annonymous/Unregistered users

Anyone not registered or not logged in will not be able to edit ANYTHING on the site.

2) Lab Users

This is anyone who we KNOW to be doing research in the lab (names taken from SignupMonkey). They will be allowed to edit existing pages but will NOT be allowed to upload files or create new pages. Also, all of their edits will have to be approved by staff members before they are viewable on the site.

3) Staff

This group consist of all of you staff members. You will be able to edit 95% of the pages on the wiki. There are a select few pages on the site that locked preventing you form screwing them up. For example, look at Main Page. You will not have the option to "EDIT" the page, only the option to "VIEW SOURCE"

4) Administrators

This group is for the people in charge of maintaining the nitty-gritty of the site. They have unrestricted access and can change anything on the site. They can also change the "user group level" for any user.

Approved Edits

While lab users are allowed to modify the wiki, their edits will not become visible to anyone but the staff until a staff member approves those edits. Note that when any member of the staff edits a page, those edits are automatically approved. BE CAREFUL though because if a page has edits waiting to be approved and you edited the page normally, those edits will automatically be approved!! Before you edit a page, always make sure that there are no new revisions waiting to be approved (this is described below).

When you arrive at a page, you will see one of two messages. Either "No new revisions" or "THERE ARE NEW REVISIONS TO THIS PAGE.".

No new revisions.
THERE ARE NEW REVISIONS TO THIS PAGE.

If there are new revisions, click on the history tab.

History tab.

This will take you to the full edit history of the page. You will see an entry that has a star on it, this is the current approved revision. Anything after that (above it) has not yet been approved. Put the LEFT radial button on the currently approved revision and set the right radial button anywhere above it to compare other additions. Click "Compare selected revisions".

History

The window will show you the before (on the left) and the after (on the right). You can also scroll down to see how the NEW page actually looks (AFTER the edit you are view has taken effect). In this case, the user "Guest" has deleted the sentence "The Sharon is a cryo-pumped thin film evaporator with a Temescal four hearth 270° bent beam evaporation source." and has inserted the sentence "THIS IS A TEST". If you like the edit and want to keep it, go back (by pressing the back button in your web-browser) and then click approve next to the edit in question. If you do NOT like the edit, click "undo", then scroll to the bottom of the page that opens and click save. If you like part of the edit but want to modify it, approve it, then edit the page as you normally would.

Approve5.png

My Watchlist

Your watchlist is the set of pages that you are "watching" for changes. You can view you watchlist at any time by clicking the link in the top right of the screen.

Watch1.png

I strongly recommend that you each add your tools to your watch list. This will allow you to see whenever these pages are modified by a user. To add a page to your watch list, go to the page you want to add and click on "watch" at the top of the page. (To remove a page from you watchlist, do the same thing, the button will read "unwatch" instead.)

Watch2.png

You can also set it up so that you will recieve an e-mail any time one of the pages on your watchlist is changed (by someone other then yourself). I would also HIGHLY recommend doing this. These emails will come from NanofabWiki@ece.ucsb.edu so you can setup a filter and put all these e-mails in one folder. You will only receive one e-mail per page between visits. In other words if 10 people make changes back to back. You will only get ONE e-mail notifying you that a change has been made, not 10 e-mails. As soon as you view the page form your account, that resets so any changes made after you view it will result in another, single e-mail.

To set this up go to your preferences by click on the "my preferences".

Watch3.png

In your preferences you will find a lot of options. The 2 that you need to take care of are your e-mail address (enter it into the box labeled "E-mail") and you need to check the box next to "E-mail me when a page on my watch-list is changed." Save the changed by clicking "Save" at the bottom of the page.