Calculators + Utilities: Difference between revisions

From UCSB Nanofab Wiki
Jump to navigation Jump to search
m (→‎Refractive Indices: specified Python)
(→‎Python Scripts: added lonk to GitHub repo for Keithley I-V script)
Line 33: Line 33:


* [http://www.wolframalpha.com Wolfram Alpha]
* [http://www.wolframalpha.com Wolfram Alpha]
** ''A'' ''versatile online interpreter/calculator, allowing calculations such as "''Volume of 1.5g of Silicon''", "''melting point of SiO2''" or "''520°C in Fahrenheit''".''


=== Python Scripts ===
=== Python Scripts ===
''These scripts are best run in the Spyder IDE, which is easily installed via Anaconda, Python(X,Y), or direct compiling using a command-line package manager.''
''These scripts are best run in the Spyder IDE, which is easily installed via [https://www.anaconda.com/download/ Anaconda], [http://python-xy.github.io Python(X,Y)], or direct compiling using a command-line package manager.''
* [[Keithley I-V Sweep|Keithley I-V Sweep]]
* [https://github.com/demisjohn/Keithley-I-V-Sweep Keithley I-V Sweep]
** Sweep voltage and plot current vs. voltage using a Keithley SMU. Already installed at the Probe Station in Bay 4 (Use '''''Python(X,Y)''''' to run), and on the QFI Thermal Microscope.
** Sweep voltage and plot current vs. voltage using a Keithley SMU.
** Already installed at the Probe Station in Bay 4, and on the QFI Thermal Microscope (Use '''''Python(X,Y)''''' to run).
** Requires the [https://pyvisa.readthedocs.io/en/stable/ pyvisa] python module.
* [[QFIScope Thermal Analysis|QFIScope Thermal Analysis]]
* [[QFIScope Thermal Analysis|QFIScope Thermal Analysis]]
** Import 2D temperature data from the [[IR Thermal Microscope (QFI)]] and plot temperature profiles at specified locations.
** Import 2D temperature data from the [[IR Thermal Microscope (QFI)]] and plot temperature profiles at specified locations.

Revision as of 02:03, 10 November 2017

This page lists a few online calculators that are useful to lab users.

Fabrication Processes & Converters

Refractive Indices

Material Parameters

Wet Etching

General Calculators

  • Anaconda Python
    • A free Matlab-like IDE and GUI, using the Python language. The Spyder interface is modeled after Matlab.
    • Includes the scientific Python libraries needed for array math (numpy), plotting (matplotlib), data science (pandas) and many others. Many open-source packages are available to extend capabilities.
  • Wolfram Alpha
    • A versatile online interpreter/calculator, allowing calculations such as "Volume of 1.5g of Silicon", "melting point of SiO2" or "520°C in Fahrenheit".

Python Scripts

These scripts are best run in the Spyder IDE, which is easily installed via Anaconda, Python(X,Y), or direct compiling using a command-line package manager.