Template:Announcements: Difference between revisions
(updates to RIE5, PECVD1) |
(lab closed thurs, deleted RIE5 SiCl4) |
||
Line 8: | Line 8: | ||
<!----------------------------------------------> |
<!----------------------------------------------> |
||
<!------------- Announcements ----------------> |
<!------------- Announcements ----------------> |
||
===== Lab Closed Thursday 10/18 7-7:30am ===== |
|||
The campus will be testing the emergency strobe system in ESB this Thursday morning (10/18/18) at 7am. No one is allowed in the Nanofab between 7 and 7:30am. The test should only take 15 minutes and I will send out an email once the lab is safe to enter. |
|||
⚫ | |||
===== RIE#5: Software Upgrades ===== |
===== RIE#5: Software Upgrades ===== |
||
Line 21: | Line 25: | ||
CARY 500 Spectrophotometer has failed - Will not be repaired - being decomissioned. New Filmetrics F10-RT-UVX being ordered as a replacement. |
CARY 500 Spectrophotometer has failed - Will not be repaired - being decomissioned. New Filmetrics F10-RT-UVX being ordered as a replacement. |
||
// [[User:Thibeault|Thibeault]] 16:40, 26 September 2018 (PDT) |
// [[User:Thibeault|Thibeault]] 16:40, 26 September 2018 (PDT) |
||
===== RIE#5: SiCl4 Issue ===== |
|||
We have a flow rate problem on the SiCl4 gas line. You can only flow the SiCl4 for 5 minutes and then you have to wait 5 minutes before you flow it again. So in order to to do a 10 minute Etch you will have to do it in three steps flow 5 mi, wait 5mi, then flow 5min. |
|||
⚫ | |||
<!---------- end of announcements ------------> |
<!---------- end of announcements ------------> |
Revision as of 21:40, 16 October 2018
UCSB NanoFab Announcements
Lab Closed Thursday 10/18 7-7:30am
The campus will be testing the emergency strobe system in ESB this Thursday morning (10/18/18) at 7am. No one is allowed in the Nanofab between 7 and 7:30am. The test should only take 15 minutes and I will send out an email once the lab is safe to enter. // John d 14:40, 16 October 2018 (PDT)
RIE#5: Software Upgrades
RIE#5 system has undergone a software upgrade. All users will need to be retrained to use the new Cortex software. // John d 14:39, 16 October 2018 (PDT)
PECVD#1: Software Upgrade
Software upgrade completed, everyone must be re-certified to use the tool. All old recipe files have been backed up but not reinstated - let us know if you need your old recipe parameters. // John d 14:39, 16 October 2018 (PDT)
CARY500 - Down - Decomissioned
CARY 500 Spectrophotometer has failed - Will not be repaired - being decomissioned. New Filmetrics F10-RT-UVX being ordered as a replacement. // Thibeault 16:40, 26 September 2018 (PDT)