== About ==
== About ==


'''Films:''' This is a Plasma-Therm model 790 plasma enhanced chemical vapor deposition system for depositing SiO<sub>2</sub>, Si<sub>3</sub>N<sub>4</sub>, or SiO<sub>x</sub>N<sub>y</sub> dielectric films.
This is a Plasma-Therm model 790 plasma enhanced chemical vapor deposition system for depositing SiO<sub>2</sub>, Si<sub>3</sub>N<sub>4</sub>, or SiO<sub>x</sub>N<sub>y</sub> dielectric films. The system uses a capacitively-coupled 13.56 MHz source excitation to produce the plasma between two parallel aluminum plates. The gas is injected over the sample through a 6” diameter showerhead. The samples are placed on the system anode (to minimize ion damage) which is heated to 250-350°C. SiO<sub>2</sub> is produced from SiH<sub>4</sub>/He 2%/98% and N<sub>2</sub>O at 250°C. The typical deposition rate is 400 A/min. at 300 mT pressure. The typical BOE etch rate of this oxide is about 400 nm/min. Si<sub>3</sub>N<sub>4</sub> is produced from SiH<sub>4</sub>/He 2%/98% and NH<sub>3</sub> at 250°C or 350°C. The more dense films are produced at 350°C. The stress of the nitride can be altered by adjusting the N<sub>2</sub>:He ratio of the deposition. CF<sub>4</sub>/O<sub>2</sub> plasmas are used to clean the chamber between depositions.


'''Hardware:''' The system uses a capacitively-coupled 13.56 MHz source excitation to produce the plasma between two parallel aluminum plates. The gas is injected over the sample through a 6” diameter showerhead. The samples are placed on the system anode (to minimize ion damage) which is heated to 250-350°C (250°C is standard).
These films are typically used for capacitor dielectrics, chemical passivation layers, electrical insulators, reactive ion etching masks, and optical anti-reflective coatings. The system is fully programmable with windows-based software and has a wide array of pre-defined thicknesses. Custom programs for dielectric stacks or different process parameters can be written and saved.

'''Gases:'''

SiH<sub>4</sub> (Silane) is the Silicon precursor gas. It is diluted with He down to 2% Silane for safety.

N<sub>2</sub>O is the Oxygen precursor gas, for producing SiO<sub>2</sub>.

NH<sub>4</sub> is the Nitrogen precursor gas, for producing Si<sub>3</sub>N<sub>4</sub>.

CF<sub>4</sub> & O<sub>2</sub> are used for plasma-cleaning the chamber, by etching off deposited SiO<sub>2</sub>/Si<sub>3</sub>N<sub>4</sub> films from the chamber walls (in addition to wet-cleaning the chamber walls).

N<sub>2</sub> is available as a purging gas or carrier gas. A very low percentage of N<sub>2</sub> is expected to "crack" at the low RF powers used on this system.

'''Film Properties:'''

SiO<sub>2</sub> is produced from SiH<sub>4</sub>/He 2%/98% and N<sub>2</sub>O at 250°C. The typical deposition rate is 400 Å/min at 300 mT pressure. The typical BOE etch rate of this oxide is about 400 nm/min.

Si<sub>3</sub>N<sub>4</sub> is produced from SiH<sub>4</sub>/He 2%/98% and NH<sub>3</sub> at 250°C or 350°C. The more dense films are produced at 350°C. The stress of the nitride can be altered by adjusting the N<sub>2</sub>:He ratio of the deposition.

'''Applications:''' These films are typically used for reactive ion etching masks, electrical insulators, chemical passivation layers, optical anti-reflective coatings and capacitor dielectrics. The system is fully programmable with windows-based software.

'''Usage:''' Users type in a deposition time for each recipe, using the published (or user-measured) deposition rates. Current dep rates for standard films can be found on [[Process Group - Process Control Data#PECVD #1 (PlasmaTherm 790) - Process Control|the PECVD#1 process control data charts]].

Custom programs for dielectric stacks or different process parameters or SiO<sub>x</sub>N<sub>y</sub> films can be written and saved.


== Detailed Specifications ==
== Detailed Specifications ==


*Gases used: NH<sub>3</sub>, N<sub>2</sub>O, 2%SiH<sub>4</sub>/He, N<sub>2</sub>,CF<sub>4</sub> and O<sub>2</sub>
*Gases available: NH<sub>3</sub>, N<sub>2</sub>O, 2%SiH<sub>4</sub>/He, N<sub>2</sub>,CF<sub>4</sub> and O<sub>2</sub>
*~ 10mT ultimate chamber pressure
*~10mT base chamber pressure
*13.56 Mhz excitation freq.
*13.56 MHz excitation freq.
⚫
**Automatic tuning network
⚫
**RF Power control
*Sample size: pieces to 6” wafers
*Sample size: pieces to 6” wafers
⚫
*Automatic tuning network
⚫
*RF Power control
*Full computer operation
*Full computer operation
*Standard recipes for a variety of film thicknesses
*Standard recipes with deposition variable time


==Documentation==
==Documentation==
Line 36: Line 60:
*For particle counting method, see the [https://wiki.nanotech.ucsb.edu/wiki/Wafer_scanning_process_traveler Surfscan Scanning Procedure]
*For particle counting method, see the [https://wiki.nanotech.ucsb.edu/wiki/Wafer_scanning_process_traveler Surfscan Scanning Procedure]


== Recipes & Historical Data ==
== Recipes & Data ==
* Standard Recipes & Historical (Process Control) Data can be found at:
* Standard Recipes: [[PECVD Recipes#PECVD 1 .28PlasmaTherm 790.29|'''Recipes > Deposition > <u>PECVD#1</u>''']]
* Process Control Charts: '''[[Process Group - Process Control Data#PECVD #1 (PlasmaTherm 790) - Process Control|Process Control > PECVD#1]]'''
** [[PECVD Recipes#PECVD 1 .28PlasmaTherm 790.29|'''Recipes > Deposition > <u>PECVD1</u>''']]

Revision as of 17:12, 29 September 2025

PECVD 1 (PlasmaTherm 790)
Location Bay 3
Tool Type Vacuum Deposition
Manufacturer Plasma-Therm
Description PECVD Plasma Therm 790 For Oxides And Nitrides

Primary Supervisor Michael Barreraz
(805) 893-4147
mikebarreraz@ece.ucsb.edu

Secondary Supervisor

Don Freeborn


Recipes Vacuum Deposition Recipes

SignupMonkey: Sign up for this tool


About

Films: This is a Plasma-Therm model 790 plasma enhanced chemical vapor deposition system for depositing SiO2, Si3N4, or SiOxNy dielectric films.

Hardware: The system uses a capacitively-coupled 13.56 MHz source excitation to produce the plasma between two parallel aluminum plates. The gas is injected over the sample through a 6” diameter showerhead. The samples are placed on the system anode (to minimize ion damage) which is heated to 250-350°C (250°C is standard).

Gases:

SiH4 (Silane) is the Silicon precursor gas. It is diluted with He down to 2% Silane for safety.

N2O is the Oxygen precursor gas, for producing SiO2.

NH4 is the Nitrogen precursor gas, for producing Si3N4.

CF4 & O2 are used for plasma-cleaning the chamber, by etching off deposited SiO2/Si3N4 films from the chamber walls (in addition to wet-cleaning the chamber walls).

N2 is available as a purging gas or carrier gas. A very low percentage of N2 is expected to "crack" at the low RF powers used on this system.

Film Properties:

SiO2 is produced from SiH4/He 2%/98% and N2O at 250°C. The typical deposition rate is 400 Å/min at 300 mT pressure. The typical BOE etch rate of this oxide is about 400 nm/min.

Si3N4 is produced from SiH4/He 2%/98% and NH3 at 250°C or 350°C. The more dense films are produced at 350°C. The stress of the nitride can be altered by adjusting the N2:He ratio of the deposition.

Applications: These films are typically used for reactive ion etching masks, electrical insulators, chemical passivation layers, optical anti-reflective coatings and capacitor dielectrics. The system is fully programmable with windows-based software.

Usage: Users type in a deposition time for each recipe, using the published (or user-measured) deposition rates. Current dep rates for standard films can be found on the PECVD#1 process control data charts.

Custom programs for dielectric stacks or different process parameters or SiOxNy films can be written and saved.

Detailed Specifications

  • Gases available: NH3, N2O, 2%SiH4/He, N2,CF4 and O2
  • ~10mT base chamber pressure
  • 13.56 MHz excitation freq.
    • Automatic tuning network
    • RF Power control
  • Sample size: pieces to 6” wafers
  • Full computer operation
  • Standard recipes with deposition variable time

Documentation

Recipes & Data