Template:ToolActions: Difference between revisions

From UCSB Nanofab Wiki
Jump to navigation Jump to search
Content deleted Content added
No edit summary
No edit summary
Line 14: Line 14:
</td></tr>
</td></tr>
<tr><td style="padding: 5px;" >
<tr><td style="padding: 5px;" >
{{#if:{{{toolid|}}}|
{{#if:{{{toolid|}}}|<!-- **IF toolid** -->
<table class="wikitable" style="margin: 0 auto; width: 100%;">
<table class="wikitable" style="margin: 0 auto; width: 100%;">
<th style="background: AliceBlue;">[https://signupmonkey.ece.ucsb.edu/cgi-bin/users/browse.cgi?tool_ID={{{toolid}}} Sign Up]
<th style="background: AliceBlue;">[https://signupmonkey.ece.ucsb.edu/cgi-bin/users/browse.cgi?tool_ID={{{toolid}}} Sign Up]
</th></table>
</th></table>
⚫
|<!-- if no toolid -->
⚫
<table class="wikitable" style="margin: 0 auto; width: 100%;">
⚫
<th style="background: AliceBlue;">No Signups Required
⚫
</th></table>
⚫
}}
</td></tr><tr>
</td></tr><tr>
<td style="padding: 5px;" >
<td style="padding: 5px;" >
Line 36: Line 41:
<th style="background: AliceBlue;">[https://signupmonkey.ece.ucsb.edu/cgi-bin/users/report-tool-issue.cgi?tool_ID={{{toolid}}} Report Issue]
<th style="background: AliceBlue;">[https://signupmonkey.ece.ucsb.edu/cgi-bin/users/report-tool-issue.cgi?tool_ID={{{toolid}}} Report Issue]
</th></table>
</th></table>
⚫
|<!-- if no toolid -->
⚫
<table class="wikitable" style="margin: 0 auto; width: 100%;">
⚫
<th style="background: AliceBlue;">No Signups Required
⚫
</th></table>
⚫
}}
</td></tr></table>
</td></tr></table>
</includeonly><includeonly>[[category:Tools]][[Category:{{{type|NONE}}}]]<br></includeonly><noinclude>
</includeonly><includeonly>[[category:Tools]][[Category:{{{type|NONE}}}]]<br></includeonly><noinclude>

Revision as of 02:03, 6 December 2025


Example of a Tool's Actions Box generated by this "Tool" template.
Example of a Tool's Actions Box generated by this "Tool" template.



This template inserts a "Tool Actions" panel into a page, with various Buttons for SignUpMonkey actions such as (Report Tool Issue), (Maintenance Records) and links to (Process Control Data) wiki pages.


Copy/paste the following code to include this template in a page. Preferably inserted at the top of the page.

{{ToolActions
|toolid = 51 the Tool ID number from SignupMonkey URL
|ProcessControlURL = https://wiki.nanofab.ucsb.edu/wiki/Stepper_3_(ASML_DUV)#Process_Control_Data
|InstructionsURL = https://wiki.nanofab.ucsb.edu/wiki/Stepper_3_(ASML_DUV)#Operating_Procedures
|TrainingURL = https://wiki.nanofab.ucsb.edu/wiki/Stepper_3_(ASML_DUV)#Video_Training
}}


Options

You can add the following "arguments" in the template.

  • Tool ID on SignupMonkey: The |toolid = argument will create a link to the Signup Monkey page for this tool. This is the number at the end of the url for a tool on SignupMonkey.
  • ProcessControlURL: (if applicable) URL to the Process Control wiki page.
  • InstructionsURL: (if applicable) URL to the SOP's/Instructions wiki page.
  • TrainingURL: (if applicable) URL to the SOP's/Instructions wiki page. The value `selftrain` will display that the tool is self-train only (no training required). If omitted, it will go directly to the SUM "request training" page.


Version

2025-12-05 (Demis): first version.