Content deleted Content added
Equipment Specifications: included Windows PC & scripting environments
Equipment Specifications: update Keithley model
Line 18: Line 18:
*Tektronix 370A computer controlled curve tracer
*Tektronix 370A computer controlled curve tracer
*Pulsed and DC characterization of 2 and 3 terminal devices in clean environment
*Pulsed and DC characterization of 2 and 3 terminal devices in clean environment
*Keithley 42xx Source-Meter unit
*Keithley 2400 Source-Meter unit
**Current/Voltage/Resistance readbacks, along with 4-point-probe measurements.
**Current/Voltage/Resistance readbacks, along with 4-point-probe measurements.
** Up to 200V, 1.0A
*Windows PC with:
*Windows PC with:
**GPIB Connections to the above electricla testing equipment for automated measurements.
**GPIB Connections to the above electrical testing equipment for automated measurements.
**Labview
**Labview
***I-V Curve plotting program available (read-only)
**Python(x,y)
**Python(x,y)
***I-V Curve Plotting script with Keithley 42xx
***I-V Curve Plotting script with Keithley 2400
**Matlab
**Matlab
***I-V Curve Plotting script with Keithley 42xx
***I-V Curve Plotting script with Keithley 2400

Revision as of 20:34, 9 March 2019

Probe Station & Curve Tracer
Tool Type Inspection, Test and Characterization
Location Bay 4
Supervisor Tony Bosch
Supervisor Phone (805) 893-3486
Supervisor E-Mail bosch@ece.ucsb.edu
Description Probe Station
Manufacturer Various


About

The probe station in the cleanroom is set up for up to four-point probing of two terminal and three terminal devices. The probe station is a Signatone station with a 2” diameter vacuum chuck. Four probes are provided. The measurements are taken with an HP xxxx 4-point probe measuring system or on a Tektronix 370A programmable curve tracer. The curve tracer can be controlled by a computer to get portable data. FETs, HBTs, diodes, and contact resistance measurements are typically done on this system. The 370A curve tracer is capable of pulsed and DC operation.

Equipment Specifications

  • 4 probe station
  • HP xxxx 4-point resistance meter
  • Tektronix 370A computer controlled curve tracer
  • Pulsed and DC characterization of 2 and 3 terminal devices in clean environment
  • Keithley 2400 Source-Meter unit
    • Current/Voltage/Resistance readbacks, along with 4-point-probe measurements.
    • Up to 200V, 1.0A
  • Windows PC with:
    • GPIB Connections to the above electrical testing equipment for automated measurements.
    • Labview
      • I-V Curve plotting program available (read-only)
    • Python(x,y)
      • I-V Curve Plotting script with Keithley 2400
    • Matlab
      • I-V Curve Plotting script with Keithley 2400