PubList2018: Difference between revisions
Jump to navigation
Jump to search
Content deleted Content added
formatting |
→External Users - Journal Publications: Add pubs to list |
||
| Line 1,225: | Line 1,225: | ||
|Voltage-gated closed-loop control of small-molecule release from alumina-coated nanoporous gold thin film electrodes |
|Voltage-gated closed-loop control of small-molecule release from alumina-coated nanoporous gold thin film electrodes |
||
|Advanced Functional Materials 28:1801292 (2018). |
|Advanced Functional Materials 28:1801292 (2018). |
||
|- |
|||
|Bo Wang, Lang Shen, Sisi Yang, Jihan Chen, Juliana Echternach, Rohan Dhall, DaeJin Kang and Stephen Cronin |
|||
|Defect-Induced Photoluminescence Enhancement and Corresponding Transport Degradation in Individual Suspended Carbon Nanotubes |
|||
|PHYSICAL REVIEW APPLIED 9, 054022 (2018). DOI: 10.1103/PhysRevApplied.9.054022 |
|||
|- |
|||
|Bo Wang, Sisi Yang, Lang Shen, and Stephen B. Cronin |
|||
|Ultra-Low Power Light Emission via Avalanche and Sub-avalanche Breakdown in Suspended Carbon Nanotubes |
|||
|''ACS Photonics'' 2018, 5, 11, 4432-4436 |
|||
Publication Date:October 16, 2018 |
|||
<nowiki>https://doi.org/10.1021/acsphotonics.8b00896</nowiki> |
|||
|- |
|||
|Bo Wang, Fatemeh Rezaeifar, Jihan Chen, Sisi Yang, Rehan Kapadia, and Stephen B. Cronin |
|||
|Avalanche Photoemission in Suspended Carbon Nanotubes: Light without Heat |
|||
|''ACS Photonics'' 2017, 4, 11, 2706-2710 |
|||
Publication Date:September 27, 2017 |
|||
<nowiki>https://doi.org/10.1021/acsphotonics.7b00455</nowiki> |
|||
|} |
|} |
||
Latest revision as of 23:10, 27 November 2019
Internal Users - Journal Publications
| Authors | Title | Publications |
| J. Duan, H. Huang, B. Dong, D. Jung, J.C. Norman, J.E. Bowers, F. Grillot | 1.3-um Reflection Insensitive InAs/GaAs Quantum Dot Lasers Directly Grown on Silicon | Submitted to Photonics Technology Letters (2018). |
| J.S. Lee, S. Choi, M. Pendharkar, D.J. Pennachio, B. Markman, M. Seas, S. Koelling, M.A. Verheijen,L. Casparis, K.D. Petersson, I. Petkovic, V. Schaller, M.J.W. Rodwell, C.M. Marcus, P.Krogstrup, L.P. Kouwenhoven, E.P.A.M. Bakkers, C.J. Palmstrøm | 1Selective-area chemical beam epitaxy of in-plane InAs one-dimensional channels grown on InP(001),InP(111)B, and InP(110) surfaces | arXiv preprint arXiv:1808.04563 |
| S. Liu, D. Jung, J. C. Norman, MJ Kennedy, A. C. Gossard, J. E. Bowers | 490 fs pulse generation from passively mode-locked single section quantum dot laser directly grown on on-axis GaP/Si | Electronics Letters, (54)7, 432-433, March 19, 2018. |
| C. Neill, P. Roushan, K. Kechedzhi, S. Boixo, S. V. Isakov, V. Smelyanskiy, R. Barends, B. Burkett, Y. Chen, Z. Chen, B. Chiaro, A. Dunsworth, A. Fowler, B. Foxen, R.Graff, E. Jeffrey, J. Kelly, E. Lucero, A. Megrant, J. Mutus, M. Neeley, C. Quintana, D. Sank, A. Vainsencher, J. Wenner, T. C. White, H. Neven, J. M. Martinis | A blueprint for demonstrating quantum supremacy with superconducting qubits | Science 360, Issue 6385, 195-199 (2018). arXiv:1709.06678 |
| M. Garcia, B. Ganapathysubramanian, S. Pennathur | A linearised model for calculating inertial forces on a particle in the presence of a permeate flow | Journal of Fluid Mechanics. 2019 Feb;861:253-74. |
| H. Kim, L. Theogarajan, S. Pennathur | A repeatable and scalable fabrication method for sharp, hollow silicon microneedles | Journal of Micromechanics and Microengineering, Vol. 28, No. 3, January 2018. |
| K.H. Chou, C. McCallum, D. Gillespie, S. Pennathur | An experimental approach to systematically probe charge inversion in nanofluidic channels | Nano letters. 2018 Jan 11;18(2):1191-5. |
| D. T. Spencer, T. Drake, T. C. Briles, J. Stone, L. C. Sinclair, C. Fredrick, Q. Li, D. Westly, B. Robert Ilic, A. Bluestone, N. Volet, T. Komljenovic, L. Chang, S. H. Lee, D. Y. Oh, M.-G. Suh, K. Y. Yang, M. H. P. Pfeiffer, T. J. Kippenberg, E. Norberg, L. Theogarajan, K. Vahala, N. R. Newbury, K. Srinivasan, J. E. Bowers, S.A. Diddams, S. B. Papp | An Integrated-Photonics Optical-Frequency Synthesizer | Nature Photonics, 557, 81-85, April 25, 2018. |
| X. Zheng, H. Li, M. Guidry, B. Romanczyk , E. Ahmadi, K. Hestroffer, S. Wienecke , S. Keller, U.K. Mishra | Analysis of MOCVD SiNx Passivated N-Polar GaN MIS-HEMTs on Sapphire With High fmax·VDS,Q, | IEEE Electron Device Letters, Vol. 39, No. 3, March 2018 |
| H. Huang, J. Duan, D. Jung, A. Liu, Z. Zhang, J. Norman, J. E. Bowers, F. Grillot | Analysis of the optical feedback dynamics in InAs/GaAs quantum dot lasers directly grown on silicon | Journal of the Optical Society of America B, (35)11, 2780-2787, October 12, 2018. |
| A.C. Espenlaub, A.I. Alhassan, S. Nakamura, C. Weisbuch, J.S. Speck | Auger-generated hot carrier current in photo-excited forward biased single quantum well blue light emitting diodes | Appl. Phys. Lett. 112, 141106, 2018. |
| N.A. Butakov, M.W. Knight, T.Lewi, P.P. Iyer, D. Higgs, H.T. Chorsi, J. Trastoy, J.D.V. Grande, I. Valmianski, C. Urban, Y. Kalcheim, P.Y. Wang, P.W.C. Hon, I.K. Schuller, J.A. Schuller
|
Broadband Electrically Tunable Dielectric Resonators Using Metal-Insulator Transitions | ACS Photonics 5, pp. 4054-4060 Journal |
| P. Li, B. Bonef, M. Khoury, G. Lheureux,H. Li, J. Kang, S. Nakamura, S.P. DenBaars | Carrier dynamics of two distinct localized centers in 530 nm InGaN green light-emitting diodes | Superlattices and Microstructures 113 684-689 |
| K. Ahadi,Z. Gui, Z. Porter, J. W. Lynn, Z. Xu, S. D. Wilson, A. Janotti, S. Stemmer | Carrier Density Control of Magnetism and Berry Phases in Doped EuTiO3 | APL Mater. 6, 056105 (2018). |
| S. Liu, T. Komljenovic, S. Srinivasan, E. Norberg, G. Fish, J. E. Bowers | Characterization of a fully integrated heterogeneous silicon/III-V colliding pulse mode-locked laser with on-chip feedback | Optics Express, (26)8, 9714-9723, April 4, 2018. |
| M.J. Weaver, F.Buters, F.Luna, H.Eerkens, K. Heeck, S. de Man, D.Bouwmeester | Coherent optomechanical state transfer between disparate mechanical resonators | Nature Communicationsvolume 8, Article number: 824 (2017) |
| S.H. Chan, D.Bisi, M. Tahhan, C. Gupta, S.P. DenBaars, S. Keller, E. Zanoni, U.K. Mishra | Comparing electrical characteristics of in situ and ex situ Al2O3/GaN interfaces formed by metalorganic chemical vapor deposition | Applied Physics Express, Vol. 11, No. 4, 13 March 2018 |
| D.L. Becerra, D.A. Cohen, S. Mehari, S.P. DenBaars, S. Nakamura | Compensation effects of high oxygen levels in semipolar AlGaN electron blocking layers and their mitigation via growth optimization | Journal of Crystal Growth 507 118–123 |
| C.A. Forman, S.G. Lee, E.C. Young, J.A. Kearns, D.A. Cohen, J.T. Leonard, T. Margalith, S.P. DenBaars,S. Nakamura | Continuous-wave operation of m-plane GaN-based vertical-cavity surface-emitting lasers with a tunnel junction intracavity contact | Applied Physics Letters, Vol. 112, Issue 11, 2018. |
| S.R. Meeker, B.A. Mazin, A.B. Walter, P. Strader, N.Fruitwala, C. Bockstiegel, P. Szypryt, G. Ulbricht, G. Coiffard, B. Bumble, G. Cancelo, T. Zmuda, K. Treptow, N. Wilcer, G. Collura, R. Dodkins, I. Lipartito, N. Zobrist, M. Bottom, J. C. Shelton, D. Mawet, J.C. van Eyken, G. Vasisht, E. Serabyn | DARKNESS: A Microwave Kinetic Inductance Detector Integral Field Spectrograph for High-contrast Astronomy | Astronomical Society of the Pacific, Volume 130, Issue 988, pp. 065001 (2018). |
| M. Buffolo, M. Pietrobon, C. De Santi, F. Samparisi, M. L. Davenport, J. E. Bowers, G. Meneghesso, E. Zanoni, M. Meneghini | Degradation mechanisms of heterogeneous III-V/Silicon loop-mirror laser diodes for photonic integrated circuits | Microelectronics Reliability, 88-90, 855-858, September 30, 2018. |
| B. Romanczyk, S. Wienecke, M. Guidry, H. Li, E. Ahmadi, X. Zheng, S. Keller, U.K. Mishra | Demonstration of Constant 8 W/mm Power Density at 10, 30, and 94 GHz in State-of-the-Art Millimeter-Wave N-Polar GaN MISHEMTs | IEEE Transactions On Electron Devices, Vol. 65, No. 1, Jan 2018 |
| S. Mehari, D.A. Cohen, D.L. Becerra, S. Nakamura, S.P. DenBaars | Demonstration of enhanced continuous-wave operation of blue laser diodes on a semipolar 20(21)over-bar GaN substrate using indium-tin-oxide/thin-p-GaN cladding layers | Optics Express, Vol. 26, Issue 2,1564 2018. |
| A.I. Alhassan, N.G. Young, R.M. Farrell, C. Pynn, F. Wu, A.Y. Alyamani, S. Nakamura, S.P. Denbaars, J.S. Speck | Development of high performance green c-plane III-nitride light-emitting diodes | Optics express, vol. 26, no. 5: Optical Society of America, pp. 5591–5601, 2018. |
| B. Saifaddin, C. J. Zollner, A. Almogbel, H. Foronda, F. Wu, A. Albadri, A. Al Yamani, M. Iza, S. Nakamura, S. P. DenBaars, et al. | Developments in AlGaN and UV-C LEDs grown on SiC | Light-Emitting Diodes: Materials, Devices, and Applications for Solid State Lighting XXII, vol. 10554: International Society for Optics and Photonics, pp. 105541E, 2018. |
| R. Salemmilani, B.D. Piorek, A.W. FountainIII, M. Moskovits, C.D. Meinhart | Dielectrophoretic Nanoparticle Aggregation for On-Demand Surface Enhanced Raman Spectroscopy Analysis | Anal. Chem.201890137930-7936
Publication Date:June 4, 2018 |
| W. Xie, J. Huang, T. Komljenovic, L. Coldren, J. Bowers | Diffraction Limit in Centimeter Scale: Metasurface Grating Antenna for Phased Array LiDAR | arXiv, arXiv:1810.00106, September 28, 2018. |
| D. Inoue, D. Jung, J. Norman, Y. Wan, N. Nishiyama, S. Arai, A. C. Gossard, J. E. Bowers | Directly modulated 1.3 μm quantum dot lasers epitaxially grown on silicon | Optics Express, (26)6, 7022-7033, March 7, 2018. |
| Y. Wan, D. Inoue, D. Jung, J.C. Norman, C. Shang, A.C. Gossard, J.E. Bowers | Directly modulated quantum dot lasers on silicon with a milliampere threshold and high temperature stability | Photonics Research Vol. 6, Issue 8, pp. 776-781 (2018) •https://doi.org/10.1364/PRJ.6.000776 |
| D. Jung, D.J. Ironside, S.R. Bank, A.C. Gossard, J.E. Bowers | Effect of growth interruption in 1.55 μm InAs/InAlGaAs quantum dots on InP grown by molecular beam epitaxy | Journal of Applied Physics 123, 205302 (2018); https://doi.org/10.1063/1.5031772 |
| J. Kim, H. Kim, M. E. Kilic, C. Gayner, R. Koltun, H. Park, A. Soon, J. Bowers, C. Palmstrøm, W. Kim | Effect of phonon confinement on the thermal conductivity of In0.53Ga0.47As nanofilms | Journal of Applied Physics, 123, 245103, June 25, 2018. |
| Z. Zhang, D. Jung, J. C. Norman, P. Patel, W. W. Chow, J. E. Bowers | Effects of modulation p doping in InAs quantum dot lasers on silicon | Applied Physics Letters, 113, 061105, August 7, 2018. |
| P. B. Marshall, K. Ahadi, H. Kim, S. Stemmer | Electron nematic fluid in a strained Sr3Ru2O7 film | Phys. Rev. B 97, 155160 (2018). |
| J. A. Frey, H. J. Snijders, J. Norman, A. C. Gossard, J. E. Bowers, W. Loffler, D. Bouwmeester | Electro-optic polarization tuning of microcavities with a single quantum dot | Optics letters 43 (17), 4280-4283 |
| J. A. Frey, H. J. Snijders, J. Norman, A. C. Gossard, J. E. Bowers, W. Lӧffler, D. Bouwmeester | Electro-optic tuning of microcavities with a single quantum dot | arXiv, arXiv:1805.03387, May 9, 2018. |
| A. A. Zibrov, R. Peng, C. Kometter, J.I.A. Li, C. R. Dean, T. Taniguchi, K. Watanabe, M. Serbyn, A. F. Young | Emergent Dirac gullies and gully nematic quantum Hall states in ABA trilayer graphene | Physical Review Letters 121, 167601. |
| C. Conner, T. de Visser, J. Loessberg, S. Sherman, A. Smith, S. Ma, M.T. Napoli, S. Pennathur, D. Weld | Energy Harvesting with a Liquid-Metal Microfluidic Influence Machine | Phys. Rev. Applied 9, 044008 (2018) |
| H. Li, S. Wienecke, B. Romanczyk, E. Ahmadi, M. Guidry, X. Zheng, S. Keller, U.K. Mishra | Enhanced mobility in vertically scaled N-polar high-electron-mobility transistors using GaN/InGaN composite channels | Applied Physics Letters, Vol. 112, No. 7, 13 Feb 2018 |
| A. A. Zibrov,E.M.Spanton, H.Zhou, C. Kometter, T. Taniguchi, K. Watanabe, A.F. Young | Even denominator fractional quantum Hall states at an isospin transition in monolayer graphene | Nature Physics 14, 930-935 (2018). |
| H. Snijders, J. A. Frey, J. Norman, V. P. Post, A. C. Gossard, J. E. Bowers, M. P. van Exter, W. Löffler, D. Bouwmeester | Fiber-coupled Cavity-QED Source of Identical Single Photons | Physical Review Applied, 9, 031002, March 28, 2018. |
| P. V. Klimov, J. Kelly, J. Chen, M. Neeley, A. Megrant, B. Burkett, R. Barends, K. Arya, B. Chiaro, Y. Chen, A. Dunsworth, A. Fowler, B. Foxen, C. Gidney, M. Giustina, R. Graff, T. Huang, E. Jeffrey, Erik Lucero, J. Mutus, O. Naaman, C. Neill, C. Quintana, P. Roushan, Daniel Sank, A. Vainsencher, J. Wenner, T. White, S. Boixo, R. Babbush, V. Smelyanskiy, H. Neven, John M. Martinis | Fluctuations of Energy-Relaxation Times in Superconducting Qubits | arXiv:1809.01043, September 2018 |
| K. Scida, A. Eden, N. Arroyo-Curras, S. MacKenzie, Y. Satik, C.D. Meinhart, J.C. Eijkel, S. Pennathur | Fluorescence-Based Observation of Transient Electrochemical and Electrokinetic Effects at Nanoconfined Bipolar Electrodes | ACS applied materials & interfaces. 2019 Mar 18. |
| R.-L. Chao, L. Liang, J.-W. Shi, T. Komljenovic, J. Hulme, M. J. Kennedy, J. E. Bowers | Fully Integrated Photonic Millimeter-Wave Tracking Generators on Heterogeneous III-V/Si Platform | IEEE Photonics Technology Letters, (30)10, 919-922, April 10, 2018. |
| S.G. Lee, C.A. Forman, C. Lee, J. Kearns, E.C. Young, J.T. Leonard, D.A. Cohen, J.S. Speck, S. Nakamura, S.P. DenBaars | GaN-based vertical-cavity surface-emitting lasers with tunnel junction contacts grown by metal-organic chemical vapor deposition | Applied Physics Express, Vol. 11, Issue 6, 062703, 2018. |
| M.N. Fireman, H. Li, S. Keller, U. K. Mishra, J. S. Speck | Growth of N-polar GaN by ammonia molecular beam epitaxy | Journal of Crystal Growth, vol. 481: North-Holland, pp. 65–70, 2018. |
| H. Nili, G.C. Adam, B. Hoskins, M. Prezioso, J. Kim, M.R. Mahmoodi, F. Merrikh Bayat, O. Kavehei, D.B. Strukov | Hardware-intrinsic security primitives enabled by analogue state and nonlinear conductance variations in integrated memristors | Nature Electronics 1, pp. 197–202, 2018 (Journal Cover). |
| J.E. Bowers, L. Chang | Heterogeneous integration for optical signal processing | Roadmap on Optical Signal Processing submitted (2018). |
| M. L. Davenport, M. A. Tran, T. Komljenovic, J. E. Bowers | Heterogeneous Integration of III-V lasers on Si by Bonding | Book Chapter 6, Semiconductors and Semimetals, Vol. 99, Academic Press, October 8, 2018. |
| W. Xie, T. Komljenovic, J. Huang, M. Tran, M.L. Davenport, A. Torres, P. Pintus, J. Bowers | Heterogeneous Silicon Photonics Sensing for Autonomous Cars | Optics Express (2018). |
| L. Chang, A. Boes, X. Guo, D. T. Spencer, MJ. Kennedy, J. D. Peters, N. Volet, J. Chiles, A. Kowligy, N. Nader, D. D. Hickstein, E. J. Stanton, S. A. Diddams, S. B. Papp, J. E. Bowers | Heterogeneously Integrated GaAs waveguides on Insulator for Efficient Frequency Conversion | Laser and Photonics Reviews, (12)10, 1800149, August 14, 2018. |
| R. Jones, P. Doussiere, J. B. Driscoll, W. Lin, H. Yu, Y. Akulova, T. Komljenovic, J. E. Bowers | Heterogeneously Integrated Photonics | Nanotechnology Magazine (2018). |
| M.S. Wong, D. Hwang, A.I. Alhassan, C. Lee, R. Ley, S. Nakamura, S.P. DenBaars | High efficiency of III-nitride micro-light-emitting diodes by sidewall passivation using atomic layer deposition | Optics Express, Vol. 26, Issue 16, 2018. |
| R. Helkey, A. Saleh, J. Buckwalter, J.E. Bowers | High Performance Photonic Integrated Circuits on Silicon | JSTQE Dec. 2018. |
| J.C. Norman, D. Jung, Z. Zhang, Y. Wan, S. Liu, C. Shang, R.W. Herrick, W.W. Chow, A.C. Gossard, J.E. Bowers | High Performance Quantum Dot Lasers on Silicon | JQE Sept 2018. |
| B.P. Yonkee, E.C. Young, S.P. DenBaars, J.S. Speck, S. Nakamura | High reflectivity Ohmic contacts to n-GaN utilizing vacuum annealed aluminum | Semiconductor Science and Technology, Vol. 33, Issue 1, 015015, 2018. |
| N. Arroyo-Curras, K. Scida, K.L. Ploense, T.E. Kippin, K.W. Plaxco | High Surface Area Electrodes Generated via Electrochemical Roughening Improve the Signaling of Electrochemical Aptamer-Based Biosensors | Anal. Chem. 2017, 89, 12185-12191. |
| B.E. Tew, P. Vempati, L.E. Clinger, N.I. Halaszynski, Gilles, Pernot, T. Favaloro, C.C. Bomberger, A. Shakouri, J.E. Bowers, J-H. Bahk, J. M. O. Zide | High Thermoelectric Power Factor and ZT in TbAs:InGaAs EpitaxialNanocomposite Material | submitted High Thermoelectric Power Factor (2018). |
| S. Liu, X. Wu, D. Jung, J.C. Norman, M. Kennedy, H.K. Tsang, A.C. Gossard, J.E. Bowers | High-channel-count low-noise 20 GHz passively mode locked quantum dot laser directly grown on Si with 4.1 Tbit/s transmission capacity | submitted to Optica (2018). |
| C. Weisbuch | Historical perspective on the physics of artificial lighting | Comptes Rendus Physique 19, 3, 2018. |
| D.J. Myers, , K. Gelžinytė, W. Ying Ho, J. Iveland, L. Martinelli, J. Peretti, C. Weisbuch, J. S. Speck | Identification of low-energy peaks in electron emission spectroscopy of InGaN/GaN light-emitting diodes | Journal of Applied Physics, vol. 124, pp. 055703, 2018. |
| R. Hermann, M.J. Gordon | Imaging Intermolecular Exciton Coupling in Metal-Free Phthalocyanine Nanofilms Using Tip-Enhanced Near-Field Optical Microscopy | J. Phys. Chem. C 2018, 122, 26, 14796-14804. |
| M. Monovarian, A. Rashidi, A. A. Aragon, S. H. Oh, A. K. Rishinaramangalam, Steven P. DenBaars, D. Feezell | Impact of crystal orientation on the modulation bandwidth of InGaN/GaN light-emitting diodes | Applied Physics Letters, 2018. |
| D. Jung, R. Herrick, J. Norman, K. Turnlund, C. Jan, K. Feng, A. C. Gossard, J. E. Bowers | Impact of threading dislocation density on the lifetime of InAs quantum dot laser on Si | Applied Physics Letters, 112, 153507, April 13, 2018. |
| F. Merrikh Bayat, M. Prezioso, B. Chakrabarti, H. Nili, I. Kataeva, D. Strukov | Implementation of multilayer perceptron network with highly uniform passive memristive crossbar circuits | Nature Communications 9, art. 2331, 2018. |
| M. L. Davenport, S. Liu, J. E. Bowers | Integrated heterogeneous silicon/III-V mode-locked lasers | Photonics Research, (6)5, 468-478, April 20, 2018. |
| T. A. Huffman, G. M. Brodnik, C. Pinho, S. Gundavarapu, D. Baney, D. J. Blumenthal | Integrated Resonators in an Ultralow Loss Si3N4/SiO2 Platform for Multifunction Applications | IEEE Journal of Selected Topics in Quantum Electronics, vol. 24, no. 4, pp. 1-9, July-Aug (2018). |
| Y. Liu et al. | Integrated Silicon Nitride Optical Beamforming Networks for Wideband Communications | Integrated Photonics Research, Silicon and Nanophotonics, 2018, p. ITh3B–4. |
| P. Bhasker, J. Norman, J. Bowers, N. Dagli | Intensity and Phase Modulators at 1.55 μm in GaAs/AlGaAs Layers Directly Grown on Silicon | IEEE/OSA J. of Lightwave Technology, vol. LT-36, No. 18, pp. 4205-4210, September 15, 2018. |
| A. Spott, E. J. Stanton, A. Torres, M. L. Davenport, C. L. Canedy, I. Vurgaftman, M. Kim, C. S. Kim, C. D. Merritt, W. W. Bewley, J. R. Meyer, J. E. Bowers | Interband Cascade Laser on Silicon | Optica, (5)8, 996-1005, August 16, 2018. |
| C-C. Chang, A. Nowbahar, V. Mansard, I. Williams, J. Mecca, A. Schmitt, T. Kalantar, T-C. Kuo, T.M. Squires | Interfacial rheology and heterogeneity of aging asphaltene layers at the water-oil interface | Langmuir , 34, 5409−5415 (2018) 10.1021/acs.langmuir.8b00176. |
| S. Gundavarapu, M. Belt, T.A. Huffman, M.A. Tran, T. Komljenovic, J.E. Bowers, D.J. Blumenthal | Interferometric Optical Gyroscope Based on an Integrated Si3N4 Low-Loss Waveguide Coil | J. Lightwave Technol. 36, 1185-1191 (2018). |
| D. Feezell, S. Nakamura | Invention, development, and status of the blue light-emitting diode, the enabler of solid-state lighting | C.R.Physique 19 113–133 |
| C. Lund, A. Agarwal, B. Romanczyk, T. Mates, S. Nakamura, S.P. Denbaars, U.K. Mishra, S. Keller | Investigation of Mg delta-doping for low resistance N-polar p-GaN films grown at reduced temperatures by MOCVD | Semiconductor Science and Technology, Vol. 33, Issue 9, 2018. |
| B.A. Mazin, G.D. Becker, G. Cancelo, K. France, W.C. Fraser, T. Jones, S.R. Meeker, K. O'Brien, J.X. Prochaska, S. Tendulkar, G. Vasisht | KRAKENS: a superconducting MKID integral field spectrograph concept for the Keck I telescope | SPIE, Volume 10702, id. 107020H 20 pp. (2018). |
| C. Weisbuch, E. Spitz, A. David | LEDs: The new revolution in lighting Foreword | Comptes Rendus Physique 19, 3, 2018. |
| J. Wu,Y. Fang, B. Markman, H-Y. Tseng, M.J. W. Rodwell, | Lg=30 nm InAs Channel MOSFETs Exhibitingfmax=410 GHz andft=357 GHz | IEEE ELECTRON DEVICE LETTERS, VOL. 39, NO. 4, APRIL 2018 |
| K. Sun, D. Jung, C. Shang, A. Liu, J. Morgan, J. Zang, Q. Li, J. Klamkin, J. E. Bowers, A. Beling | Low dark current III–V on silicon photodiodes by heteroepitaxy | Optics Express, (26)10, 13605-13613, May 11, 2018. |
| D. Inoue, Y. Wan, D. Jung, J. Norman, C. Shang, N. Nishiyama, S. Arai, A. C. Gossard, J. E. Bowers | Low-dark current 10 Gbit/s operation of InAs/InGaAs quantum dot p-i-n photodiode grown on on-axis (001) GaP/Si | Applied Physics Letters, 113, 093506, August 30, 2018. |
| Y. Liu, B. Isaac, J. Kalkavage, E. Adles, T. Clark, J. Klamkin | Low-loss silicon nitride integrated optical beamforming network for wideband communication | Terahertz, RF, Millimeter, and Submillimeter-Wave Technology and Applications XI, 2018, vol. 10531, p. 1053 118. |
| Y. Wan, D. Jung, C. Shang, N. Collins, I. MacFarlane, J. Norman, M. Dumont, A. C. Gossard, J. E. Bowers | Low-Threshold Continuous-Wave Operation of Electrically-Pumped 1.55 μm InAs Quantum Dash Microring Lasers | ACS Photonics, December 26, 2018. |
| A. Nowbahar, V. Mansard, J. Mecca, M. Paul, T. Arrowood, T. M. Squires | Measuring Interfacial Polymerization Kinetics Using Microfluidic Interferometry | J. Am. Chem. Soc. 140 , 3173 - 3176 (2018). |
| H. Wu, C. Li, L. Song, H.-K. Tsang, J. E. Bowers, and D. Dai | Meta-surface-enabled ultra-sharp multimode waveguide bends on silicon | arXiv:1811.06914, October 14, 2018. |
| D. Hwang, A.J. Mughal, M.S. Wong, A.I. Alhassan,S. Nakamura, S,P. DenBaars | Micro-light-emitting diodes with III-nitride tunnel junction contacts grown by metalorganic chemical vapor deposition | Appl. Physics Express, Vol. 11, Issue 1, 012102, 2018. |
| N. Volet, X. Yi, Q.-F. Yang, E. J. Stanton, P. A. Morton, K. Y. Yang, K. J. Vahala and J. E. Bowers | Micro-Resonator Soliton Generated Directly with a Diode Laser | Laser & Photonic Reviews, (12)5, 1700307, April 17, 2018. |
| T. N. Do, H. Phan, T.-Q. Nguyen, and Y. Visell | Miniature Soft Electromagnetic Actuators for Robotic Applications | Advanced Functional Materials, 2018. Cover article. |
| R.Dodkins, S.Mahashabde, K.O’Brien, N.Thatte, N.Fruitwala, A.B.Walter, S.R.Meeker, P.Szypryt, B.A.Mazin | MKID digital readout tuning with deep learning | Astronomy and Computing
Volume 23, April 2018, Pages 60-71 |
| S. Liu, J. C. Norman, D. Jung, MJ Kennedy, A. C. Gossard and J. E. Bowers | Monolithic 9 GHz passively mode locked quantum dot lasers directly grown on on-axis (001) Si | Applied Physics Letters, (113)4, 041108, July 27, 2018. |
| L.C. Chan, D.E. Morse, and M.J. Gordon | Moth eye-inspired anti-reflective surfaces for improved IR optical systems & visible LEDs fabricated with colloidal lithography and etching | Bioinspir. & Biomim. 13, 041001 (2018). |
| R. Jiang, X. Shen, J. Fang, P. Wang, E.X. Zhang, J. Chen, D.M. Fleetwood, R.D. Schrimpf, S.W.Kaun, E,C.H. Kyle, et al. | Multiple Defects Cause Degradation After High Field Stress in AlGaN/GaN HEMTs | IEEE Transactions on Device and Materials Reliability, vol. 18, pp. 364-376, Sept, 2018. |
| E.J. Stanton, A. Spott, J. Peters, M.L. Davenport, A. Malik, N. Volet, J. Liu, C.D. Merritt, W.W. Bewley, I. Vurgaftman, C.S. Kim, J.R. Meyer, J.E. Bowers | Multi-spectral quantum cascade lasers on silicon with integrated multiplexers | Submitted 2018. |
| A. S. P. Khope, M. Saeidi, R. Yu, X. Wu, A. Netherton, Y. Liu, Z. Zhang, Y. Zia, G. Fleeman, A. Spott, S. Pinna, C. Schow, R. Helkey, L. Theogarajan, R. C. Alferness, A. Saleh, and J. E. Bowers | Multi-wavelength selective crossbar switch | submitted to Optics Express, 2018. |
| R. Katsumata, R. Limary, Y. Zhang, B.C. Popere, A.T. Heitsch, M. Li, P. Trefonas, R.A. Segalman | Mussel-inspired strategy for stabilizing ultrathin polymer films and its application to spin-on doping of semiconductors | Chem. Mater., 30, 5285-5292 (2018). [DOI] |
| A. Ariyaratne, D. Bluvstein, B. A. Myers & A. C. Bleszynski Jayich | Nanoscale electrical conductivity imaging using anitrogen-vacancy center in diamond | Nature Communications volume 9, Article number: 2406 (2018) |
| R. Hermann and M.J. Gordon | Nanoscale optical microscopy and spectroscopy using near-field probes | Ann. Rev. Chem. Bio. Eng. 9, 1 (2018). |
| L. Galletti, T. Schumann, T. E. Mates, and S. Stemmer | Nitrogen surface passivation of the Dirac semimetal Cd3As2 | Phys. Rev. Mater. 2, 124202 (2018). |
| O.S. Koksaldi, J. Haller, H. Li, B. Romanczyk, M. Guidry, S. Wienecke, S. Keller, U.Mishra | N-Polar GaN HEMTs Exhibiting Record Breakdown Voltage Over 2000 V and Low Dynamic On-Resistance | EDL, July 2018 |
| S-H. Han, A. Mauze, E. Ahmadi, T. Mates, Y. Oshima, and J. S. Speck | n-type dopants in (001) β-Ga2O3 grown on (001) β-Ga2O3 substrates by plasma-assisted molecular beam epitaxy | Semiconductor Science and Technology, vol. 33, no. 4: IOP Publishing, pp. 045001, 2018. |
| E. M. Spanton, A. A. Zibrov, H. Zhou, T. Taniguchi, K. Watanabe, M. P. Zaletel, A. F. Young | Observation of fractional Chern insulators in a van der Waals heterostructure | Science 360, 62–66 (2018).L. Galletti, T. Schumann, T. E. Mates, and S. Stemmer, Nitrogen surface passivation of the Dirac semimetal Cd3As2, Phys. Rev. Mater. 2, 124202 (2018). |
| T. Schumann, L. Galletti, D. A. Kealhofer, H. Kim, M. Goyal, and S. Stemmer | Observation of the quantum Hall effect in confined films of the three-dimensional Dirac semimetal Cd3As2 | Phys. Rev. Lett. 120, 016801 (2018). |
| H. J. Snijders,J. A. Frey,J. Norman,H. Flayac,V. Savona,A. C. Gossard,J. E. Bowers,M. P. van Exter,D. Bouwmeester,W. Löffler | Observation of the Unconventional Photon Blockade | PHYSICAL REVIEW LETTERS121,043601 (2018) |
| J. Kang, Y. Matsumoto, X. Li, J. Jiang, X. Xie, K. Kawamoto, M. Kenmoku, J. H. Chu, W. Liu, J. Mao, K. Ueno, K. Banerjee | On-Chip Intercalated-Graphene Inductors for Next-Generation Radio Frequency Electronics | Nature Electronics, Vol. 1, No. 1, pp. 46-51, 2018. |
| D. Valovcin, H.B. Banks, S. Mack, A. Gossard, K. West, L. Pfeiffer, M.S. Sherwin | Optical Frequency Combs from High-Order Sideband Generation | Optics Express 26, 29807-29816 (2018) [www][arXiv] |
| N. Dagli | Optical Modulators | Handbook of Optoelectronics, 2nd Edition: Concepts, Devices and Techniques, vol. 1, Chapter 14, pp. 457-514, CRC Press, Taylor and Francis, 2018. |
| T. Mizumoto, R. Baets, and J. E. Bowers | Optical nonreciprocal devices for silicon photonics using wafer-bonded magneto-optical garnet materials | MRS Bulletin, (43)6, 419-424, June 11, 2018. |
| J. C. Norman, D. Jung, Y. Wan, and John E. Bowers | Perspective: The Future of Quantum Dot Photonic Integrated Circuits | Applied Physics Letters Photonics, (3)3, 030901, March 27, 2018. |
| M. J. Weaver, D. Newsom, F. Luna, W. Löffler, D. Bouwmeester | Phonon interferometry for measuring quantum decoherence | Phys. Rev. A 97, 063832 – Published 14 June 2018 |
| T. Komljenovic, D. Huang, P. Pintus, M. A. Tran, M. L. Davenport, and J. E. Bowers | Photonic Integrated Circuits Using Heterogeneous Integration on Silicon | Proceedings of the IEEE, (106)12, 2246-2257, August 30, 2018. |
| A. Y. Liu and J. Bowers | Photonic Integration with Epitaxial III-V on Silicon | IEEE Journal of Selected Topics in Quantum Electronics, (24)6, 6000412, July 9, 2018. |
| M. Buffolo, F. Samparisi, C. De Santi, G. Meneghesso, E. Zanoni, D. Jung, J. Bowers, R. W. Herrick, and M. Meneghini | Physical Origin of the Optical Degradation of InAs Quantum Dot Lasers | submitted to Journal of Quantum Electronics (JQE) (2018). |
| W. Jin, R. G. Polcawich, P. Morton, and J. Bowers | Piezoelectrically tuned silicon nitride ring resonator | Optics Express, (26)3, 3174-3187, February 5, 2018. |
| A.E. Cetin,P. Iyidogan, Y. Hayashi, M. Wallen, K. Vijayan,†E. Tu, M. Nguyen, A. Oliphant | Plasmonic Sensor Could Enable Label-Free DNA Sequencing | ACS Sens. 2018, 3, 561−568. |
| H.J. Snijders, D.N.L. Kok, M.F. van de Stolpe, J. A. Frey, J. Norman A. C. Gossard, J. E. Bowers, M.P. van Exter, D. Bouwmeester, and W. Löffler | Polarized quantum dot cavity-QED and single photons | submitted Physical Review Applied (2018). |
| D. Ding, D. van Driel, L. M. C. Pereira, J. F. Bauters, M. J. R. Heck, G. Welker, M. J. A. de Dood, A. Vantomme, J. E. Bowers, W. Loer, and D. Bouwmeester | Probing interacting two-level systems with rare-earth ions | arXiv, arXiv:1811.05248, November 13, 2018. |
| L.Y. Kuritzky, C. Weisbuch, and J. S. Speck | Prospects for 100% wall-plug efficient III-nitride LEDs | Opt. Express, vol. 26, pp. 16600–16608, Jun, 2018. |
| ?. Polshyn, H. Zhou, E. M. Spanton, T. Taniguchi, K. Watanabe, and A. F. Young | Quantitative transport measurements of fractional quantum Hall energy gaps in edgeless graphene devices | Physical Review Letters 121, 226801 (2018). |
| J.C. Norman, D. Jung, Z. Zhang, Y. Wan, S. Liu, C. Shang, R. Herrick, W.W. Chow, A.C. Gossard, J.E. Bowers | Quantum Dot Lasers for Monolithic Photonic Integration | JQE (2018). |
| D. Jung, J. Norman, Y. Wan, S. Liu, R. Herrick, J. Selvidge, K. Mukherjee, A. C. Gossard, and J. E. Bowers | Recent Advances in InAs Quantum Dot Lasers Grown on on-axis (001) Silicon by Molecular Beam Epitaxy | Physica Status Solidi A, (216)1, 1800602, January 9, 2019. |
| A.I. Alhassan, E.C. Young, A.Y. Alyamani, .Albadri, S.Nakamura, S.P. DenBaars, J.S. Speck | Reduced-droop green III-nitride light-emitting diodes utilizing GaN tunnel junction | Applied Physics Express, Vol. 11, Issue 4, 042101, 2018. |
| Z. Gu, S. Pandya, A. Samanta, S. Liu, G. Xiao, C. J. G. Meyers, A. R. Damodaran, H. Barak, A. Dasgupta, S. Saremi, A. Polemi, L. Wu, A.A. Podpirka, A. Will-Cole,C.J. Hawley, P.K.Davies, R.A. York, I. Grinberg, L.W. Martin, J.E. Spanier | Resonant domain-wall-enhanced tunable microwave ferroelectrics | 2018 Springer Nature Limited, https://doi.org/10.1038/s41586-018-0434-2. |
| Y. Kalcheim, N.A. Butakov, N. Vargas, M.H. Lee, J.D.V. Grande, J. Trastoy, P. Salev, J.A. Schuller, and I.K. Schuller |
Robust Coupling between Structural and Electronic Transitions in a Mott Material | Physical Review Letters 122, pp. 057601, 1-6 Journal |
| G. Yu, A. Jenkins, X. Ma, S. A. Razavi, C. He, G. Yin, Q. Shao, Q. L. He, H. Wu, W. Li, W. Jiang, X. Han, X. Li, A. C. Bleszynski Jayich, P. Khalili Amiri, and K. L. Wang | Room-Temperature Skyrmions in an Antiferromagnet-Based Heterostructure | Nano Lett., 2018, 18 (2), pp 980–986 |
| J. Lozi, O. Guyon, N. Jovanovic, S. Goebel, P. Prashant N. Skaf, A. Sahoo, B. Norris, F. Martinache M. N'Diaye, B. Mazin, A.B. Walter, P. Tuthill, T. Kudo, H. Kawahara, T. Kotani, M. Ireland, N. Cvetojevic, E. Huby, S. Lacour, V. Sébastien; T.D. Groff, J.K. Chilcote, J. Kasdin, J. Knight, F. Snik, D. Doelman, Y Minowa, C. Clergeon, N. Takato, M. Tamura, T. Currie, H. Takami, M. Hayashi | SCExAO, an instrument with a dual purpose: perform cutting-edge science and develop new technologies | SPIE, Volume 10703, id. 1070359 12 pp. (2018). |
| J.S. Lee, S. Choi, M. Pendhakar, D.J. Pennachio, B. Markman, M.J.W. Rodwell, P. Krogstrup, and C.J. Palmstrom | Selective-area chemical beam epitaxy of in-plane one-dimensional channels grown on InP(001) and InP(111)B surfaces | Submitted(2018) – arXiv:1808.04563. |
| J. Duan, H. Huang, D. Jung, Z. Zhang, J. Norman, J. E. Bowers, and F. Grillot | Semiconductor quantum dot lasers epitaxially grown on silicon with low linewidth enhancement factor | Applied Physics Letters, 112, 251111, June 21, 2018. |
| M. Khoury, H. Li, B.Bonef, L.Y. Kuritzky, A.J. Mughal,S.Nakamura, J.S. Speck, S.P. DenBaars | Semipolar (20(2)over-bar1) GaN templates on sapphire: 432nm InGaN light-emitting diodes and light extraction simulations | Applied Physics Express, Vol. 11, Issue 3, 036501, 2018. |
| C. Lee, C. Shen, C. Cozzan, R. M. Farrell, S. Nakamura, A. Y. Alyamani, B. S. Ooi, J. E. Bowers, S. P. DenBaars, and J. S. Speck | Semipolar GaN-based laser diodes for Gbit/s white lighting communication: devices to systems | Gallium Nitride Materials and Devices XIII, vol. 10532: International Society for Optics and Photonics, pp. 105321N, 2018. |
| S. Mehari, D.A. Cohen, D.L Becerra, S. Nakamura, S.P. DenBaars | Semipolar InGaN blue laser diodes with a low optical loss and a high material gain obtained by suppression of carrier accumulation in the p-waveguide region | Japanese Journal of Applied Physics 58, 2 |
| C. Shen, T.K. Ng, C. Lee, S. Nakamura, J.S. Speck, S.P. Denbaars, A.Y. Alyamani, M.M. El-Desouki, B.S. Ooi | Semipolar InGaN quantum-well laser diode with integrated amplifier for visible light communications | Optics express, vol. 26, no. 6: Optical Society of America, pp. A219–A226, 2018. |
| D.J. Blumenthal, R. Heideman, D. Geuzebroek, A. Leinse and C. Roeloffzen | Silicon nitride in silicon photonics | Proceedings of the IEEE Special Issue on Silicon Photonics, Vol. 106 No. 12 DOI: 10.1109/JPROC.2018.2861576 (2018) |
| H.J. Snijders, J. A. Frey, J. Norman, H. Flayac, V. Savona, A. C. Gossard, J. E. Bowers, M. P. van Exter, D. Bouwmeester, W. Löffler | Single photons and unconventional photon blockade in quantum dot cavity-QED | arXiv.org > quant-ph > arXiv:1803.10992 |
| A. Jenkins, M. Pelliccione, G. Yu, X. Ma, X. Li, K. L. Wang, A. C. Bleszynski Jayich | Single spin sensing of domain wall structure and dynamics in a thin film skyrmion host | arXiv:1812.01764, December 2018 |
| M. Prezioso, M. Mahmoodi, F. Merrikh Bayat, H. Kim, H. Nili, A. Vincent, and D. Strukov | Spike-timing-dependent plasticity learning of coincidence detection with passively integrated memristive circuits | Nature Communications 9, art. 5311, 2018. |
| C. Zube, J. Malindretos, L. Watschke, R.R. Zamani, D. Disterheft, R.G. Ulbrich, A.Rizzi, M. Iza, S. Keller, S.P. DenBaars | Spin injection in epitaxial MnGa(111)/GaN(0001) heterostructures | Journal of Applied Physics Vol. 123, Issue 3, 2018 |
| K. Ahadi, H. Kim, and S. Stemmer | Spontaneous Hall effects in the electron system at the SmTiO3/EuTiO3 interface | APL Mater. 6, 056102 (2018). |
| A. Boes, B. Corcoran, L. Chang, J. Bowers, and A. Mitchell | Status and Potential of Lithium Niobate on Insulator (LNOI) for Photonic Integrated Circuits | Laser & Photonics Reviews, (12)4, 1700256, February 23, 2018. |
| L. Megalini, S. T. Š. Brunelli, W. O. Charles, A. Taylor, B. Isaac, J. E. Bowers, and J. Klamkin | Strain-Compensated InGaAsP Superlattices for Defect Reduction of InP Grown on Exact-Oriented (001) Patterned Si Substrates by Metal Organic Chemical Vapor Deposition | Materials, 11, 337, February 28, 2018. |
| L. Chang, A. Boes, P. Pintus, J. Peters, M. Kennedy, X-W. Guo, N. Volet, S-P. Yu, S. Papp, J. Bowers | Strong frequency conversion in heterogeneously integrated GaAs resonators | submitted to Optica (2018). |
| S. Sonar, V. Fedoseev, M.J. Weaver, F.Luna,E. Vlieg, H. van der Meer,D. Bouwmeester, W. Löffler | Strong thermomechanical squeezing in a far-detuned membrane-in-the-middle system | PHYSICAL REVIEW A98, 013804 (2018) |
| S. Gundavarapu, G.M. Brodnik, M. Puckett, T. Huffman, D. Bose, R. Behunin, J. Wu, T. Qiu, C. Pinho, N. Chauhan, J. Nohava, P.T. Rakich, K.D. Nelson, M. Salit, D.J. Blumenthal | Sub-hertz fundamental linewidth photonic integrated Brillouin laser | Nat. Photon., 13(1): 60-67 (2019). |
| S. Lal, J. Lu, B.J. Thibeault, M.H. Wong, S.P. DenBaars, U.K. Mishra | Suppression of Anomalously Large Threshold Voltage in Wafer-Bonded Vertical Transistors by Enhancing Critical Field to Impact Ionization | IEEE Transactions on Electron Devices, 2018. |
| N.A. Butakov, I. Valmianski, T. Lewi, C. Urban, Z. Ren, A.A. Mikhailovsky, S.D. Wilson, I.K. Schuller, J.A. Schuller |
Switchable Plasmonic-Dielectric Resonators with Metal-Insulator Transitions | ACS Photonics 5, pp. 371 Journal |
| T. Lewi, N.A. Butakov, and J.A. Schuller |
Thermal Tuning Capabilities of Semiconductor Metasurface Resonators | Nanophotonics 8, pp.331-338 Journal |
| N. Liu, J. Peters, J.A. Floro, A. Ramu, J.E. Bowers, M. Zebarjadi | Thermoelectric transport at F4TCNQ-silicon interface | submitted to APL Materials (2018). |
| M. Goyal, L. Galletti, S. Salmani-Rezaie, T. Schumann, D. A. Kealhofer, and S. Stemmer | Thickness dependence of the quantum Hall effect in films of the three-dimensional Dirac semimetal Cd3As2 | APL Mater. 6, 026105 (2018). |
| H-H. Chen, J.S. Speck, C. Weisbuch, Y-R Wu | Three dimensional simulation on the transport and quantum efficiency of UVC-LEDs with random alloy fluctuations | Appl. Phys. Lett. 113, 153504, 2018. |
| D. Huang, P. Pintus and J. E. Bowers | Towards heterogeneous integration of optical isolators and circulators with lasers on silicon | Optical Materials Express, (8)9, 2471-2483, August 1, 2018. |
| M. Monavarian, A. Rashidi, A. A. Aragon, M. Nami, S. H. Oh, S. P. DenBaars, D. Feezell | Trade-off between bandwidth and efficiency in semipolar (20(2)over-bar(1)over-bar) InGaN/GaN single- and multiple-quantum-well light-emitting diodes | Applied Physics Letters, Vol. 112, Issue 19, 2018. |
| R. Kaminker, I.Kaminker, W.R. Gutekunst, Y. Luo, S. Lee, J. Niu, S. Han, C.J. Hawker | Tuning conformation and properties of peptidomimetic backbones through dual N/Cα-substitution | Chem. Commun. 2018 54, 5237-5240. |
| R. Kaminker, A. Anastasaki, W.R. Gutekunst, Y. Luo, S-H. Lee, C.J. Hawker | Tuning of protease resistance in oligopeptides through N-alkylation | Chem. Commun. 2018 54, 9631-9634. |
| L. Galletti, T. Schumann, O. F. Shoron, M. Goyal, D. A. Kealhofer, H. Kim, and S. Stemmer | Two-Dimensional Dirac Fermions in Thin Films of Cd3As2 | Phys. Rev. B 97, 115132 (2018). |
| Y. Liu et al. | Ultra-Low-Loss Silicon Nitride Optical Beamforming Network for Wideband Wireless Applications | IEEE J. Sel. Topics Quantum Electron., vol. 24, no. 4, pp. 1–10, 2018. |
| M. A. Tran, D. Huang, T. Komljenovic, J. Peters, A. Malik, and J. E. Bowers | Ultra-Low-Loss Silicon Waveguides for Heterogeneously Integrated Silicon/III-V Photonics | Applied Sciences, 8, 1139, July 12, 2018. |
| D. Dai, J. Bowers | Ultra-sharp multimode waveguide bends with subwavelength gratings | Laser & Photonics Reviews (2018). |
| H.A. Dobbs, Y. Kaufman, J. Scott, K. Kristiansen, A.M. Schrader, S.Y. Chen, P. Duda III, J.N. Israelachvili | Ultra‐Smooth, Chemically Functional Silica Surfaces for Surface Interaction Measurements and Optical/Interferometry‐Based Techniques | Advanced Engineering Materials 20 (2), 1700630 |
| C. Conner, T. de Visser, J. Loessberg , S. Sherman, A. Smith, S. Ma, M.T. Napoli, S. Pennathur | Weld D. Energy Harvesting with a Liquid-Metal Microfluidic Influence Machine | Physical Review Applied. 2018 Apr 5;9(4):044008. |
| A. Myzaferi, A.J. Mughal, D.A. Cohen, R.M. Farrell, S.Nakamura, J.S. Speck, S.P. Denbaars | Zinc oxide clad limited area epitaxy semipolar III-nitride laser diodes | Optics Express, Vol. 26, Issue 10, 12490 , 2018. |
Internal User - Conference Papers
| Authors | Title | Conference |
| M.J.W. Rodwell, Y. Fang, J. Rode, J. Wu, B. Markman, S. T. S. Brunelli, J. Klamkin, M Urteaga | 100-340GHz Systems: Transistors and Applications | 2018 IEEE International Electron Devices Meeting (IEDM), 14.3. 1-14.3. 4 |
| J.S. Lee, S. Choi, M. Pendharkar, A.P. McFadden, and C.J. Palmstrom | 1D InAs channels byselective-area growth for topological superconductivity applications | Am. Phys. Soc. March Meeting (Los Angeles CA 2018) |
| B. Song, S. Pinna, Y. Liu, L. Megalini, and J. Klamkin | 3D hybrid integrated lasers for silicon photonics | vol. 10537. International Society for Optics and Photonics 2018 p. 105370V. |
| B. Song, C. Stagarescu, W. Jin, P. Abolghasem, S. Ristic, N. Bickel, J. Bowker, A. Behfar, and J. Klamkin | 3D Integrated Silicon Photonic External Cavity Laser | Conference on Lasers and Electro-Optics, paper SM4G.5. |
| S. Liu, J.C. Norman, D.Jung, M. Kennedy, A.C. Gossard, J.E. Bowers | 9 GHz passively mode locked quantum dot lasers directly grown on Si Device | Research Conference (DRC) 2018 |
| J. Norman, S. Liu, D. Jung, M. Kennedy, A. Gossard, J. Bowers | 96 GHz Colliding Pulse Mode-locked Quantum Dot Lasers Grown on Silicon | NAMBE (2018). |
| L. Chang, X. Guo, D.T. Spencer, J. Chiles, A. Kowligy, N. Nader, D. Hickstein, M. Kennedy, A. Boes, N. Volet, S.A. Diddams, S.B. Papp, J.E. Bowers | A gallium arsenide nonlinear platform on silicon | CLEO (2018) |
| S. Liu, T. Komljenovic, S. Srinivasan, E. Norberg, G. Fish, J.E Bowers | A Heterogeneously Integrated III-V/Si Colliding Pulse Mode-locked Laser with On-chip Feedback | The Optical Fiber Communication Conference and Exposition (OFC); San Diego, CA; March 11-14, 2018 |
| M. Tran, T. Komljenovic, D. Huang, L. Liang, M. Kennedy,J.E. Bowers | A Widely-Tunable High-SMSR Narrow-Linewidth Laser Heterogeneously Integrated on Silicon | CLEO (2018) |
| Z. Zhang, D. Jung, J.C. Norman, P. Patel, W.W. Chow, J.E. Bowers | Across Zero Continuously Tunable Linewidth Enhancement Factor in 1.3 µm InAs Quantum Dot Lasers on Silicon | postdeadline paper at ISLC (2018). |
| P. Bhasker, S. Dogru and N. Dagli | Active-Passive Integration using a-Si waveguides for Substrate Removed Electro-Optic Modulators | 2018 IEEE Photonics Conference (IPC), DOI: 10.1109/IPCon.2018.8527092, Reston, VA, 30 September-4 October 2018. |
| J. Bowers | Advanced laser designs for large-scale photonic integration | 3rd WestLake Photonics Symposium (WPS), Zhejiang University, Hangzhou, China (2018). |
| D.B. Strukov | Analog neurocomputing with emerging memory devices | APS Society March Meeting, Los Angeles, CA, Mar. 2018 |
| P. A. Morton, Jacob, J. E. Bowers | Beyond Moore's Law’ Photonic Integrated Circuits for RF Photonics and Sensing Systems | GOMAC (2018). |
| K. Scida, N. Arroyo-Currás, Y.Satik, A. Eden, J.C.T. Eijkel, S. Pennathur | Bipolar electrode-induced electrokinetic effects in nanochannels generate fluorescence enhancement and sharp pH gradients in the absence of a voltage bias | 256th ACS National Meeting & Exposition 2018: Nanoscience, Nanotechnology … |
| J. Jiang, J.H. Chu, K. Banerjee | CMOS-Compatible Doped-Multilayer-Graphene Interconnects for Next-Generation VLSI | IEEE International Electron Devices Meeting (IEDM), San Francisco, December 1-5, 2018, pp. 34.5.1-34.5.4. (One of the two IEDM 2018 papers selected in Research Highlights of Nature Electronics, Nov 30, 2018) . |
| M. Weaver, J. Luna, V. Fedoseev, S. Sonar, F. Buters, D. Newsom, K. Heeck, W. LöFfler, D. Bouwmeester | Coherent Coupling between Different Mechanical Modes | APS March Meeting 2018, abstract id.B27.011 |
| C.A. Forman, S. Lee, E.C. Young, J.A. Kearns, D.A. Cohen, J.T. Leonard, T.Margalith, S.P. DenBaars, S. Nakamura | Continuous-wave operation of nonpolar GaN-based vertical-cavity surface-emitting lasers | Gallium Nitride Materials and Devices XIII, 2018 |
| L. Megalini, S.T. Suran Brunelli, W. Charles, A. Taylor, B. Isaac, J. Bowers and J. Klamkin | Defect Filtering in InP-on-Si via Strain-Compensated InGaAsP Superlattices in MOCVD | 2018 Compound Semiconductor Week (CSW), Cambridge, MA 2018 |
| M. Buffolo, M. Pietrobona, C. De Santia, M. L. Davenport, J. E. Bowers, G. Meneghesso, E. Zanonia, M. Meneghinia | Degradation mechanisms of heterogeneous III-V/Silicon loop-mirror laser diodes for photonic integrated circuits | ESREF conference 2018. |
| M. Buffolo, M. Meneghini, C. D. Santi, M. L. Davenport, J. E. Bowers, G. Menegheso, and E. Zanoni | Degradation Mechanisms of Heterogenous III-V 1.55 μm DBR Laser Diodes | Photonics West 2018 |
| C. D. Merritt, W. W. Bewley, C. L. Canedy, C. S. Kim, I. Vurgaftman, J. R. Meyer, A. Spott, J. Peters, M. L. Davenport, E. J. Stanton, C. Zhang, J, E. Bowers, J. Kirch, L. J. Mawst, and D. Botez | Development of Quantum and Interband Cascade Lasers on Silicon | submitted to Photonics West 2018, Smart Photonic and Optoelectronic Integrated Circuits Conference. |
| J. Meyer, A. Spott, E. Stanton, J.Bowers | Development of Quantum and Interband Cascade Lasers on Silicon, Smart Photonic and Optoelectronic Integrated Circuits XX | part of SPIE OPTO, http://spie.org/OE111 (2018). |
| B. SaifAddin, C.J. Zollner, A.Almogbel, H. Foronda, F. Wu, A. Albadri, A.A. Yamani, M. Iza, S. Nakamura, S.P. DenBaars, J.S. Speck | Developments in AlGaN and UV-C LEDs grown on SiC | Light-Emitting Diodes: Materials Devices and Applications for Solid State Lighting XXII 2018 |
| Y. Wan, D. Inoue, D. Jung, J. Norman, C. Shang, A.C. Gossard, J. E. Bowers | Directly modulated quantum dot micro-ring lasers at 1.3 µm on (001) GaP/Si with low-threshold current | 2018 Progress In Electromagnetics Research Symposium (PIERS 2018) Toyama, Japan, on 1-4 August, 2018. |
| N.A. Butakov, M.W. Knight, T.Lewi, P.P. Iyer, H.T. Chorsi, J.D.V. Grande, Y. Kalcheim, P.W.C. Hon, I.K. Schuller, and J.A. Schuller
|
Electrically Switchable Infrared Nanophotonic Devices with VO2 | 2018 76th IEEE Device Research Conference (DRC) Conference Proceedings |
| L. Chan, R. Ley, P. Shapturenka, C.D. Pynn, S.P. DenBaars, M. Gordon | Enhancing Light Extraction from Free-standing InGaN/GaN Light Emitters Using Bio-inspired Backside Surface Structuring | AVS annual meeting |
| L.C. Chan, M.J. Gordon | Fabrication Chemical Lift-Off and Optical Characterization of Nanoscale III-Nitride Light Emitters | AVS annual meeting |
| J-W Shi, R-L Chao, J.C. Hulme, T. Komljenovic, J.E. Bowers | Fully Integrated Photonic Microwave/Millimeter-Waves Frequency Tracking Synthesizer on Heterogeneous III-V/Si Platform | CO-24 at Japan (8/21). |
| Z. Zhang, D. Jung, J. Norman, P. Patel, A.C. Gossard, J.E. Bowers | Gain Characterization and Parameter Extraction of 1.3 μm InAs Quantum Dot Lasers on Silicon | CLEO (2018) |
| Z. Ahang, D. Jung, J.C. Norman, P.Patel, W.W. Chow, J.E. Bowers | Gain Characterization of p-doped 1.3 μm InAs Quantum Dot Lasers on Silicon: Theory and Experiment | International Semiconductor Laser Conference (2018). |
| C.C. Evans, A. Spott, C.D. Merritt, W.W. Bewley, I.Vurgaftman, C.S. Kim, J.R. Meyer, J.M. Hensley, J.E. Bowers, M.B. Frish | Gas Sensing Using Heterogeneously Integrated Quantum Cascade Lasers on Silicon | CLEO (2018) |
| A.Malik, E.J. Stanton, J.Liu, A.Spott,J.E. Bowers | Ge-on-Si wavelength division multiplexing components near 4.7 μm | CLEO (2018) |
| J. Bowers | Heterogeneous integration on silicon | Tutorial at European Conference on Communications (ECOC), Rome, Italy, Sept.23-27, 2018. |
| J. Bowers | High Efficiency Quantum Dot Photonic Integrated Circuits on Si | CLEO 2018 |
| L. Chang, A. Boes, P. Pintus, J.D. Peters, M. Kennedy, X. Guo, N. Volet, S. Yu, S.A. Diddams, S.B. Papp, J.E. Bowers | High efficiency SHG in heterogenous integrated GaAs ring resonators | postdeadline paper at IPC 2018 |
| D. Jung, R. Herrick, J. Norman, Y. Wan, A.C. Gossard, J.E. Bowers | High performance and reliable 1.3 μm InAs quantum dot lasers epitaxially grown on Si | 2018 23rd Opto-Electronics and Communications Conference (OECC) |
| D. Jung, J. Norman, MJ Kennedy, C. Shang, R. Herrick, Y. Wan, B. Shin, I. MacFarlane, C. Jan, A. C. Gossard, J. E. Bowers | High performance InAs quantum dot lasers grown on on-axis (001) Si with low threading dislocation density | PCSI 2018. |
| J.C. Norman, Z. Zhang, D. Jung, Y. Wan, M. J. Kennedy, A. Torres, R.W. Herrick, A.C. Gossard, J.E. Bowers | High performance quantum dot lasers epitaxially integrated on Si | Proceedings Volume 10771, Quantum Communications and Quantum Imaging XVI; 107710D (2018) https://doi.org/10.1117/12.2319627
Event: SPIE Optical Engineering + Applications, 2018, San Diego, California, United States |
| D. Jung, R.Herrick, J.Norman, C. Jan, N. Caranto, A. Torres, Y. Wan, A.C. Gossard, J.E. Bowers | Highly Improved Reliability of Low Threshold 1.3 μm III/V Quantum Dot Laser Epitaxially Grown on On-axis Si | 2018 Conference on Lasers and Electro-Optics (CLEO) |
| P.A. Morton, M.J. Morton, C.Zhang, J.B. Khurgin, J.Peters, C.D. Morton, J.E. Bowers | High-Power, High-SFDR, Heterogeneously Integrated III-V on Si MZI Modulators | Research and Applications of Photonics in Defense Conference (RAPID) 2018 |
| D.Inoue, D.Jung, Y. Wan, J.Norman, N. Nishiyama, S. Arai, A.C. Gossard, J.E. Bowers | High-speed direct modulation of 1.3 μm InAs quantum dot laser grown on on-axis (001) Si substrate | 65th JSAP Spring Meeting (2018). |
| D.Inoue, D.Jung, Y. Wan, J.Norman, N. Nishiyama, S. Arai, A.C. Gossard, J.E. Bowers | High-speed direct modulation of 1.3 μm InAs quantum dot laser grown on on-axis (001) Si substrate | 79th JSAP Autumn Meeting, September 2018. |
| J. C. Norman, D. Jung, P. Pintus, Y. Wan, Q. Li, P. Bhasker, Z. Zhang, C. Shang, M. Kennedy, N. Dagli, K. M. Lau, A. C. Gossard, J. E. Bowers | InAs Quantum Dot Devices for Epitaxial Photonic Integrated Circuits on Silicon | ICMBE (2018) |
| D. Jung, J. Norman, Y. Wan, S. Liu, R. Herrick, A. Gossard, J. Bowers | InAs quantum dot lasers epitaxially grown on on-axis (001) silicon | Group IV Photonics, Cancun, Mexico, Aug. 29 (2018). |
| D. Jung, J. Norman, Y. Wan, S. Liu, R. Herrick, A. Gossard, J. Bowers | InAs Quantum dot Lasers Epitaxially Grown on On-Axis (001) Silicon | 2018 IEEE 15th International Conference on Group IV Photonics (GFP). |
| B. Isaac, B. Song, S. Pinna, S. Arafin, L. Coldren and J. Klamkin | Indium Phosphide Photonic Integrated Circuit Transmitter with Integrated Linewidth Narrowing for Laser Communications and Sensing | 2018 IEEE International Semiconductor Laser Conference (ISLC), Santa Fe, NM, 2018, pp. 1-2. |
| M. Kassis, D. Chan, S. Kwok, T. Krasuski, J.E. Lyke, S. Ragland, S. Lilley, S. Cetre, P. Wizinowich, H.A. Lewis, P. Gomez, L. Rizzi, J.E. Larkin, T. Do, M.P. Fitzgerald, A. Skemer, J.X. Prochaska, K. Westfall, B. Mazin, D. Mawet, K. Matthews, C. Martin, A.W. Howard, J.R. Lu, M.R. Chun | Innovations and advances in instrumentation at the W. M. Keck Observatory | Proceedings Volume 10702, Ground-based and Airborne Instrumentation for Astronomy VII; 1070207 (2018) https://doi.org/10.1117/12.2312316
Event: SPIE Astronomical Telescopes + Instrumentation, 2018, Austin, Texas, United States |
| D. J. Blumenthal, S. Gundavarapu, D. Bose, G. Brodnik, T. Huffman, R. Behunin, P. Rakich | Integrated Low Linewidth Brillouin Lasers in Ultra Low Loss Si3N4 Waveguide Platform | Conference on Lasers and Electro-Optics, OSA Technical Digest, paper FW3E.3 (2018). |
| P. Pintus, D. Huang, P. Morton, Y. Shoji, T. Mizumoto, J.E. Bowers | Integrated optical isolator and circulator in silicon photonics | European Conference on Communications (ECOC) Rome, Italy Sept.23-27, 2018 |
| P. Bhasker, J. Norman, J. Bowers, and N. Dagli | Intensity and Phase Modulators at 1.55 µm with InAs/InGaAs Quantum Dots Epitaxially Grown on Silicon | Conference on Lasers and Electro-Optics - Pacific Rim, Hong Kong, China, July 29-August 3, 2018. |
| C. D. Merritt, A. Spott, E. J. Stanton, I. Vurgaftman, C. L. Canedy, A. Torres, M. Kim, M. L. Davenport, C. S. Kim, N. Volet, W. W. Bewley, A. Malik J. Liu, J. R. Meyer, and J. E. Bowers | Interband and Quantum Cascade Lasers Integrated on Silicon, Mid-IR Optoelectronic Materials and Devices | (MIOMD), Flagstaff, Arizona, October, 2018. |
| C. D. Merritt, W. W. Bewley, C. L. Canedy, C. S. Kim, I. Vurgaftman, and J. R. Meyer, M. Kim, A. Spott, E. J. Stanton, A. Torres, M. L. Davenport, and John E. Bowers | Interband Cascade Lasers Integrated on Silicon | SPIE Defense and Commercial Sensing conference in Orlando, April 19, 2018. |
| T. Squires | Keynote lecture | 16th International Conference on Surface Forces Kazan Russia August 20-25 2018 |
| B. A. Mazin, G.D. Becker, G. Cancelo, K. France, W.C. Fraser, T. Jones, S.R. Meeker, K. O'Brien, J.X. Prochaska, S. Tendulkar, G. Vasisht | KRAKENS: a superconducting MKID integral field spectrograph concept for the Keck I telescope | Proceedings Volume 10702, Ground-based and Airborne Instrumentation for Astronomy VII; 107020H (2018) https://doi.org/10.1117/12.2312221
Event: SPIE Astronomical Telescopes + Instrumentation, 2018, Austin, Texas, United States |
| J. Bowers | Large Scale Photonic Integrated Circuits | Plenary Talk,ACP, Hangzhou, China, Oct. 26-29, 2018. |
| A. Jain, X. Wu, J. E. Bowers, R. Helkey, and J. Buckwalter | Linear Ring Modulators with DC Kerr Phase Shifters | 2018 IEEE Avionics and Vehicle Fiber-Optics and Photonics Conference (AVFOP), Portland, OR, USA, Nov 13-14, 2018. |
| X. Wu, W.Zhou, D.Huang, Z.Zhang, Y.Wang, J.Bowers, H.K. Tsang | Low Crosstalk Bent Multimode Waveguide for On-chip Mode-Division Multiplexing Interconnects | CLEO (2018) |
| J. Duan, H. Huang, D. Jung, J. Norman, J. E. Bowers, and F. Grillot | Low linewidth enhancement factor and high optical feedback resistance of p-doped silicon based quantum dot lasers | IPC (2018). |
| J. E. Bowers | Low threshold, high gain 1300 nm quantum dot lasers epitaxially grown on Si | PQE, 2018. |
| P. Bhasker, J. Norman, J. Bowers, and N. Dagli | Low Voltage, High Optical Power Handling, Bulk GaAs/AlGaAs Electro-optic Modulators | Integrated Photonics Research, Silicon, and Nano-Photonics Conference proceedings, paper IW3B.4, Zurich, Switzerland, 2-5 July 2018. |
| D.B. Strukov | Mixed-signal nanoelectronic neurocomputing | keynote talk at AI Design Forum at Applied Materials Inc., San Jose, CA, May 2018 |
| D.B. Strukov | Mixed-signal neurocomputing | IEEE Custom Integrated Circuits Conference (CICC’18), San Diego, CA, Apr. 2018 |
| D.B. Strukov | Mixed-signal neuromorphic inference accelerators | International Workshop on Future Computing (IWOFC'18), Shenzhen, China, Dec. 2018. |
| D.B. Strukov | Mixed-signal neuromorphic inference accelerators | ARL workshop on Nanotechnology-Enabled Beyond von Neumann Computing, Adelphi, Maryland, Nov. 2018 |
| D.B. Strukov | Mixed-signal vector-by-matrix multiplication with nonvolatile memories | Non-Volatile Memory Technology Symposium (NVMTS'18), Sendai, Japan, Oct. 2018 |
| Y. Zhang+, R. Katsumata+, S.P.O. Danielsen, B.C. Popere, A.T. Heitsch, M. Li, P. Trefonas, R.A. Segalman(+equally contributing authors) | Molecular Design Strategies of Polymeric Spin-on Doping for Silicon | Gordon Research Seminar and Conference, Polymer Physics, South Hadley, MA July 2018. |
| M.A. Tran, D. Huang, T.Komljenovic, S. Liu, L. Liang, M. Kennedy, J. E. Bowers | Multi-ring Mirror-based Narrow-Linewidth Widely-Tunable Lasers in Heterogeneous Silicon Photonics | European Conference on Communications (ECOC) Rome Italy Sept.23-27 2018 |
| A.K. Rishinaramangalam, A. Rashidi, S.M.U. Masabih, A.A. Aragon, M. Monavarian, C. Lee, S.P. DenBaars, D. F. Feezell | Nonpolar GaN-Based Superluminescent Diode with 2.5 GHz Modulation Bandwidth | 2018 IEEE International Semiconductor Laster Conference |
| O.S. Koksaldi, J. Haller, H. Li, N. Hatui, B. Romanczyk, M. Guidry, S. Wienecke, S. Keller, U. Mishra | N-Polar GaN HEMTs for High Voltage Switching Applications Demonstrating Negligible Dispersion at 450 V Quiescent Bias | ISCS, May 2018, Boston, MA |
| D. Inoue, D. Jung, J.Norman, Y. Wan, N. Nishiyama, S. Arai, A.C. Gossard, J.E. Bowers | NRZ and PAM-4 direct modulation of 1.3 μm quantum dot lasers grown directly on on-axis (001) Si | European Conference and Exhibition on Optical Communication (ECOC) Rome Italy (2018). |
| O. J. Ohanian, A. A. Yakusheva, S. T. Kreger, D. Kominsky, B. J. Soller, M. Tran, T. Komljenovic, and J. E. Bowers | OFDR on Photonic Circuits: Fiber Optic Sensing Infrastructure and Applications | 26th International Conference on Optical Fiber Sensors, OSA Technical Digest (Optical Society of America, 2018), paper WB1. |
| Y.Wan, D.Jung, D. Inoue, J.C. Norman, C. Shang, A.C. Gossard, J.E. Bowers | On-chip detection from directly modulated quantum dot microring lasers on Si | PIERS 2018 |
| D.B. Strukov | Opportunities and challenges for neurocomputing with nonvolatile memories | International Memory Workshop (IMW’18), Kyoto, Japan, May 2018 |
| S. Mehari, D.A. Cohen, D.L Becerrea, C. Weisbuch, S. Nakamura, S.P. DenBaars | Optical Gain and Loss Measurements of Semipolar III-nitride Laser Diodes with ITO/thin-p-GaN Cladding Layers | 2018 76TH DEVICE RESEARCH CONFERENCE (DRC) |
| J. Bowers | Optical Integration: The Path to Terabit Transceivers | IPC, Virginia, (2018). |
| T. Komljenovic, J. Bowers | Path to Tbps Silicon Photonic Transceivers | First North American Conference on Silicon Photonics for High Performance Computing, Colorado Springs, (2018). |
| P. J. M. Suni, J. Bowers, L. Coldren, S.J. Ben Yoo | Photonic Integrated Circuits for Coherent Lidar | 19th Coherent Laser Radar Conference (CLRC), Okinawa, Japan, June 18-21, 2018. |
| I.P. Marko, A. Baltusis, A.R. Adams, D. Jung, J.C. Norman, J.E. Bowers, S.J. Sweeney | Physical properties of 1.3 µm InAs-based quantum dot laser on silicon | ISLC (2018) |
| T. Squires | Plenary Lecture | European Fluid Mechanics Conference (Euromech), Vienna, Austria, September 9-13, 2018 |
| J.A. Frey, H.J Snijders, J. Norman, A.C. Gossard, J.E. Bowers, W. Löffler, D. Bouwmeester | Polarization tuning for high-fidelity fiber-coupled single photon sources | PROCEEDINGS VOLUME 10733 SPIE NANOSCIENCE + ENGINEERING | 19-23 AUGUST 2018 Quantum Photonic Devices 2018 |
| Y. Wan, D. Jung, J. Norman, K. Feng, A. Dagli, A.C. Gossard, J.E. Bowers | Quadruple reduction of threshold current density for micro-ring quantum dot lasers epitaxially grown on (001) Si | CLEO: Science and Innovations 2018 San Jose, California United States 13–18 May 2018 ISBN: 978-1-943580-42-2 |
| E.J. Stanton, A. Spott, J.D. Peters, M.L. Davenport, N.Volet, A. Malik, J. Liu, C.D. Merritt, W.W. Bewley, I. Vurgaftman, C.S. Kim, J.R. Meyer, J.E. Bowers | Quantum cascade multi-spectral laser with integrated beam combiner on silicon | CLEO (2018) |
| J. Bowers | Quantum dot lasers on Si | CSW conference Boston May (2018) |
| C. Shang, Y. Wan, D. Jung, J. Norman, M.J. Kennedy, D. Liang, C. Zhang, A.C. Gossard, J.E. Bowers | Quantum dot micro-lasers integrated with photodetectors and optical amplifiers on (001) Si via waveguide coupling | 2018 Conference on Lasers and Electro-Optics (CLEO) |
| Y. Zhang, A. D’Ambra, R. Katsumata, R. Burns, M. Somervell, R. Segalman, C. Hawker, C. Bates | Rapid and Selective Deposition of Patterned Thin Films via Spin Coating. | Semiconductor Research Corporation (SRC) Global Research Collaboration (GRC) Technology Transfer e-Workshop. 04/24/2019 |
| D. Seo, A.M. Schrader, S.Y. Chen, Y. Kaufman, T.R. Cristiani, S.H. Page, P.H. Koenig, Y. Gizaw, D.W. Lee, J.N. Israelachvili | Rates of cavity filling by liquids | Proceedings of the National Academy of Sciences 115 (32), 8070-8075 |
| D.B. Strukov | Recent results and future prospects for mixed-signal nanoelectronic neurocomputing | DARPA ERI Workshop, San Francisco, CA, July 2018 |
| D. Jung, R. Herrick, J. Norman, J. Selvidge, M. Kennedy, C. Jan, K. Mukherjee, A.C. Gossard, J.E. Bowers | Reliability study of InAs quantum dot lasers on Si | MRS Annual Meeting (2018). |
| M.R. Mahmoodi, H. Nili, and D.B. Strukov | RX-PUF: Low power, dense, reliable, and resilient physically unclonable functions based on analog passive RRAM crossbar arrays | in: Proc. VLSI Symp’18, Honolulu, HI, June 2018, art. 176. |
| P. Shapturenka, S. Denbaars, and M.J. Gordom | Scalable & Tunable High-Contrast Gratings for Integration into Resonant-Cavity micro-LEDs | AVS annual meeting |
| Y. Zhang, R. Katsumata, M. Somervell, R. Burns, R. Segalman, C. Hawker, C. Bates | Selective Spin Dewetting on Heterogeneous Surfaces Induced by Imperfect Self-Assembled Monolayers | Semiconductor Research Corporation TECHCON, Austin, TX. 09/17/2018 |
| Y. Zhang, R. Katsumata, M. Somervell, R. Burns, R. Segalman, C. Hawker, C. Bates | Selective Spin Dewetting on Heterogeneous Surfaces Induced by Imperfect Self-Assembled Monolayers. | Chemical Engineering Graduate Student Symposium, Santa Barbara, CA. 10/05/2018 |
| Y. Zhang, A. D’Ambra, R. Katsumata, R. Segalman, C. Hawker, C. Bates | Selective Spin-on Deposition Enabled by Imperfect Self-Assembled Monolayers. | The International Society for Optics and Photonics (SPIE) Advanced Lithography Conference, San Jose, CA. 02/27/2019 |
| Y. Zhang, A. D’Ambra, R. Katsumata, R. Burns, M. Somervell, C. Hawker, R. Segalman, C. Bates, | Selective Spin-on Deposition of Polymers on Heterogeneous Surfaces | American Physical Society (APS) March Meeting, Boston, MA. 03/04/2019 |
| Y. Zhang, R. Katsumata, M. Somervell, R. Burns, C. Hawker, R. Segalman, C. Bates | Selective Spin-on Deposition of Polymers on Heterogeneous Surfaces | Materials Research Outreach Program, Santa Barbara, CA. 01/30/2019 |
| J. Duan, K. Schires, D. Jung, J. E. Bowers, and F. Grillot | Silicon quantum dot lasers with long delay optical feedback | ISPALD (2018). |
| R. Ley, M. Wong, C. Pynn, S.P. DenBaars, M.J. Gordon | Strain Relaxation in InGaN NanoLEDs | AVS annual meeting |
| L. Megalini, S. Tommaso, Š. Brunelli, W.O. Charles, A. Taylor, B. Isaac, J.E. Bowers, J. Klamkin | Strain-compensated InGaAsP superlattices for defect reduction of InP grown on exact-oriented (001) patterned Si substrates by Metal Organic Chemical Vapor Deposition | Compound Semiconductor Workshop (2018). |
| J.S. Lee, S. Choi, M. Pendharkar, A.P. McFadden, S. Koelling, M.A. Verheijen, E.P.A.M. Bakkers, and C.J. Palmstrom | Structural and electronic characterization of in-plane InAs one-dimensional nanowires grown by selective-area epitaxy | 60th Electronic Materials Conference (Santa Barbara, CA, 2018). |
| A. Goswami, D.J. Pennachio, B. Markman, H.Y. Tseng, S.T.S. Brunelli, S. Choi, A. Taylor, J. Klamkin, M. Rodwell, C.J. Palmstrom | Structural characterization of epitaxial InP layers laterally overgrown inside dielectric templates | 60thElectronic Materials Conference (Santa Barbara CA 2018). |
| S.T. Suran Brunelli, B. Markman, J. Wu, H.Y. Tseng, A. Goswami, M. Rodwell, C. Palmstrom, and J. Klamkin | Template assisted selective epitaxy of InP via MOVPE towards horizontal heterojunctions for tunnel field effect transistors | 19th International Conference on Metalorganic Vapor Phase Epitaxy (ICMOVPE-XIX), Nara, Japan, June 3-8, 2018. |
| N. Volet, X.Yi, Q-F. Yang, E.J. Stanton, P. Morton, K.Y. Yang, K.Vahala, J.Bowers | Temporal soliton generated in a micro-resonator directly with a diode laser | Integrated Photonics Research, Silicon, and Nano-Photonics (2018). |
| N. Volet, X.Yi, Q-F. Yang, E.J. Stanton, P.A. Morton, K.Y. Yang, K.J. Vahala, J.E. Bowers | Temporal soliton locked in a micro-resonator pumped by a diode laser without an amplifier | The Optical Fiber Communication Conference and Exposition (OFC); San Diego, CA; March 11-14, 2018 |
| T. Squires | Title not provided | Student Contributed Talks: Peter Chang 2018 American Institute of Chemical Engineers |
| T. Squires | Title not provided | Student Contributed Talks: Xiaoyu Tang, 2018 American Institute of Chemical Engineers,2018 American Chemical Society Colloids |
| T. Squires | Title not provided | Student Contributed Talks: Alexandra Bayles: 2018 American Institute of Chemical Engineers 2018 APS March Meeting |
| T. Squires | Title not provided | Student Contributed Talks: Ian Williams, 2018 APS March Meeting |
| T. Squires | Title not provided | Student Contributed Talks: Anirudha Banerjee 2018 American Institute of Chemical Engineers, 2018 Gordon Research Seminar, Colloidal & Macromolecular Systems, 2018 APS March Meeting. |
| T. Squires | Title not provided | UCLA CNSI Workshop on Mathematical NanoSystems Jan 17 2018 |
| Y. Zhao, H. Fu, G.T. Wang, S. Nakamura | Toward ultimate efficiency: progress and prospects on planar and 3D nanostructured nonpolar and semipolar InGaN light-emitting diodes | ADVANCES IN OPTICS AND PHOTONICS REVIEW |
| S.T. Suran Brunelli, B. Markman, J. Wu, H.Y. Tseng, A. Goswami, C. Palmstrom, M. Rodwell, J. Klamkin | Towards Horizontal Heterojunctions for Tunnel Field Effect transistors with Template Assisted Selective Epitaxy via MOCVD | 2018 Compound Semiconductor Week (CSW), Cambridge, MA 2018 |
| B. Song, S. Pina, S. Ristic, and J. Klamkin | Tunable 3D Integrated Hybrid Silicon Laser | Asia Communications and Photonics Conference, paper Su3L.3. |
| W. Löffler, et al. | Unconventional photon blockade in polarized quantum dot cavity-QED for bright single photon sources | Quantum Communications and Quantum Imaging XVI, part of SPIE Optical Engineering + Applications. a MOCVD 2018 Compound Semiconductor Week (CSW), Cambridge, MA 2018 |
| R. Katsumata, R. Limary, B. Popere, Y. Zhang, M. Li, J. Kozhukh, A. Heitsch, P. Trefonas, R. A. Segalman | Universal strategy for stabilizing ultrathin polymer films for spin-on doping applications | APS March Meeting, Los Angels, CA, March 2018. |
| D. Huang, P. Pintus, J. Peters, P. Morton, Y. Shoji, T. Mizumoto, J.E. Bowers | Widely tunable Ce:YIG on Si microring isolators for TE mode operation | submitted to Group IV Photonics, Cancun, Mexico, Aug. 29-31 (2018). |
| C.Xiang, P.A. Morton, J.Khurgin, C. Morton, J.E. Bowers | Widely tunable Si3N4 triple-ring and quad-ring resonator laser reflectors and filters | Group IV Photonics, Cancun, Mexico, Aug. 29 (2018). |
External Users - Journal Publications
| Authors | Title | Publication |
| Z. Yang, D. Follman, A. R. Albrecht, P. Heu, N. Giannini, G. D. Cole, M. Sheik-Bahae | 16 W DBR-free membrane semiconductor disk laser with dual-SiC-heatspreader | Electronics Letters, vol. 54, no. 7, pp. 430-432, 5 April 2018 |
| M.J. Yap, J. Cripe, G.L. Mansell, T.G. McRae, R.L. Ward, B.J.J. Slagmolen, D.A. Shaddock, P.Heu, D.Follman, G.D. Cole, D.E. McClelland, T. Corbitt | Broadband reduction of quantum radiation pressure noise via squeezed light injection | arXiv.org > quant-ph > arXiv:1812.09804 |
| G. Kurczveil, A. Seyedi, D. Liang, M. Fiorentino, and R. G. Beausoleil | Error-free operation in a hybrid-silicon quantum dot comb laser | Photonics Technology Letters, vol. 30, pp. 71-74, 2018 |
| P. V. Klimov, J. Kelly, J. Chen, M. Neeley, A. Megrant, B. Burkett, R. Barends, K. Arya, B. Chiaro, Y. Chen, A. Dunsworth, A. Fowler, B. Foxen, C. Gidney, M. Giustina, R. Graff, T. Huang, E. Jeffrey, Erik Lucero, J. Mutus, O. Naaman, C. Neill, C. Quintana, P. Roushan, Daniel Sank, A. Vainsencher, J. Wenner, T. White, S. Boixo, R. Babbush, V. Smelyanskiy, H. Neven, John M. Martinis | Fluctuations of Energy-Relaxation Times in Superconducting Qubits | PRL 121, 090502 (2018).. PRL | PDF | arXiv:1803.03226 | Google AI Blog |
| V. J. Kitsmiller, M. Dummer, K. Johnson, G. D. Cole, T. D. O’Sullivan | Frequency domain diffuse optical spectroscopy with a near-infrared tunable vertical cavity | Optics Express, vol. 26, no. 16, pp. 21033-21043, 6 August 2018 |
| D. Liang, G. Kurczveil, X. Huang, C. Zhang, S. Srinivasan, Z. Huang, A. Seyedi, K. Norris, M. Fiorentino, J. E. Bowers, and R. G. Beausoleil | Heterogeneous silicon light sources for datacom applications | Optical Fiber Technology, vol. 44, pp. 43-52, 2018 |
| J.Schwender, I.Tsioutsios, A.Tavernarakis, Q.Dong, Y. Jin, U. Staufer, A. Bachtold | Improving the read-out of the resonance frequency of nanotube mechanical resonators | Appl. Phys. Lett. 113, 063104 (2018) |
| J.A. Fincher, J.E. Dyer, A.R. Korte, S.Yadavilli, N.J. Morris, A. Vertes | Matrix-free Mass Spectrometry Imaging of Mouse Brain Tissue Sections on Silicon Nanopost Arrays | J. Comp. Neurol., 2018, 1-21. https://doi.org/10.1002/cne.24566 |
| Y. Zhao, et al. | Metal Organic Framework-Coated Optical VOC Gas Sensor | 2018 IEEE Photonics Conference (IPC). IEEE, 2018. |
| A. Belushkin, F. Yesilkoy, H. Altug | Nanoparticle-Enhanced Plasmonic Biosensor for Digital Biomarker Detection in a Microarray | ACS Nano 2018, 12, 5, pp. 4453-4461, https://doi.org/10.1021/acsnano.8b00519 2018 |
| A. Boriskin, V. Drazic, R. Keating, M. Damghanian, O. Shramkova, L. Blonde | Near field focusing by edge diffraction | Vol. 43, No. 16 / 15 August 2018 / Optics Letters 4053 |
| Jonathan Cripe, Nancy Aggarwal, Robert Lanza, Adam Libson, Robinjeet Singh, Paula Heu, David Follman, Garrett D. Cole, Nergis Mavalvala, Thomas Corbitt | Observation of a room-temperature oscillator's motion dominated by quantum fluctuations over a broad audio-frequency band | arXiv.org > quant-ph > arXiv:1802.10069v1 |
| J. Cripe, B. Danz, B. Lane, M.-C. Lorio, J. Falcone, G. D. Cole, T. Corbitt | Observation of an optical spring with a beamsplitter | Optics Letters, vol. 43, no. 9, pp. 2193-2196, 1 May 2018 |
| M. Marchiò, R. Flaminio, L. Pinard, D. Forest, C. Deutsch, P. Heu, D. Follman, G.D. Cole | Optical performance of large-area crystalline coatings | Optics Express Vol. 26, Issue 5, pp. 6114-6125 (2018) |
| F. Yesilkoy, R.A. Terborg, J. Pello, A.A. Belushkin, Y. Jahani, V. Pruneri, H. Altug | Phase-sensitive plasmonic biosensor using a portable and large field-of-view interferometric microarray imager | Light: Science & Applications volume 7, page 17152 (2018) |
| A.E. Cetin, P. Iyidogan, Y. Hayashi, M. Wallen, K. Vijayan, E. Tu, M. Nguyen, A. Oliphant | Plasmonic Sensor Could Enable Label-Free DNA Sequencing | ACS Sens. 2018, 3, 561−568; DOI: 10.1021/acssensors.7b00957 2018 |
| V. Jayaraman, C. Burgner, A. Cazabat, S. Segal, K. Lascola, and F. Towner | Propelling MEMS-VCSELs into the Mid-Infrared | Compound Semiconductor, vol. 24, no. 7, 2018. |
| J. Cripe, T. Cullen, Y. Chen, P. Heu, D. Follman, G.D. Cole, T. Corbitt | Quantum back action cancellation in the audio band | arXiv.org > quant-ph > arXiv:1812.10028 |
| J. Cripe, N. Aggarwal, R. Singh, R. Lanza, A. Libson, M.-J. Yap, G. D. Cole, D. E. McClelland, N. Mavalvala, T. Corbitt | Radiation-pressure-mediated control of an optomechanical cavity | Physical Review A, vol. 97, 013827, 18 January 2018 |
| J. Pohl, G. D. Cole, U. Zeimer, M. Aspelmeyer, M. Weyers | Reduction of absorption losses in MOVPE-grown AlGaAs Bragg mirrors | Optics Letters, vol. 43, no. 15, pp. 3522-3525, 1 August 2018 |
| N. Aggarwal, T. Cullen, J. Cripe, G.D. Cole, R. Lanza, A. Libson, D. Follman, P. Heu, T. Corbitt, N. Mavalvala | Room temperature optomechanical squeezing | arXiv.org > quant-ph > arXiv:1812.09942 |
| V. Jayaraman, S. Segal, K. Lascola, C. Burgner, F. Towner, A. Cazabat, G.D. Cole, D. Follman, P. Heu, C. Deutsch | Room-temperature continuous-wave mid-Infrared VCSEL operating at 3.35um | Vertical-Cavity Surface-Emitting Lasers XXII, p. 105520B, Photonics West 2018, San Francisco, CA. |
| M. MacDougal, A. Hood, J. Thomas, G. Wicks, T. Golding, E.K. Huang | Thermoelectrically-cooled extended-SWIR FPAs using unipolar barrier detector | Proc. SPIE 10624, Infrared Technology and Applications XLIV, 1062402 (9 May 2018); https://doi.org/10.1117/12.2304388 |
| S.A. Stopka, X.A. Holmes, A.R. Korte, L.R. Compton, S.T. Retterer, A.Vertes | Trace Analysis and Reaction Monitoring by Nanophotonic Ionization Mass Spectrometry from Elevated Bowtie and Silicon Nanopost Arrays | Adv. Funct. Mater., 2018, 28, 1801730. http://dx.doi.org/10.1002/adfm.201801730 |
| S. L. de Bonis, C. Urgell, W. Yang, C. Samanta, A. Noury, J. Vergara-Cruz, Q. Dong, Y. Jin, A. Bachtold | Ultrasensitive Displacement Noise Measurement of Carbon Nanotube Mechanical Resonators | Nano Letters 18, 5324 (2018) |
| M. J. Senger, D. R. McCulley, N. Lotfizadeh, V. V. Deshpande, & E. D. Minot | Universal interaction-driven gap in metallic carbon nanotubes | Physical Review B 97, 035445 (2018) |
| Z. Li, O. Polat, E. Seker | Voltage-gated closed-loop control of small-molecule release from alumina-coated nanoporous gold thin film electrodes | Advanced Functional Materials 28:1801292 (2018). |
| Bo Wang, Lang Shen, Sisi Yang, Jihan Chen, Juliana Echternach, Rohan Dhall, DaeJin Kang and Stephen Cronin | Defect-Induced Photoluminescence Enhancement and Corresponding Transport Degradation in Individual Suspended Carbon Nanotubes | PHYSICAL REVIEW APPLIED 9, 054022 (2018). DOI: 10.1103/PhysRevApplied.9.054022 |
| Bo Wang, Sisi Yang, Lang Shen, and Stephen B. Cronin | Ultra-Low Power Light Emission via Avalanche and Sub-avalanche Breakdown in Suspended Carbon Nanotubes | ACS Photonics 2018, 5, 11, 4432-4436
Publication Date:October 16, 2018 https://doi.org/10.1021/acsphotonics.8b00896 |
| Bo Wang, Fatemeh Rezaeifar, Jihan Chen, Sisi Yang, Rehan Kapadia, and Stephen B. Cronin | Avalanche Photoemission in Suspended Carbon Nanotubes: Light without Heat | ACS Photonics 2017, 4, 11, 2706-2710
Publication Date:September 27, 2017 https://doi.org/10.1021/acsphotonics.7b00455 |
External Users - Conference Papers
| Authors | Title | Conference Details |
| E.H. Miyasaki, G. Pettersson, K. Zaw, D. John, B. Thibeault, , B. Lynch, J. Hernandez, S. Abrahamsson | 25 Plane Multifocus Microscopy Live 3D Imaging System for Neural Circuits | BPS 19’ Annual Meeting, 2019 |
| A. Roshan-Zamir, K. Yu, D. Liang, C. Zhang, C. Li, G. Fan, B. Wang, M. Fiorentino, R. Beausoleil, and S. Palermo | A 14 Gb/s Directly Modulated Hybrid Microring Laser Transmitter | in OFC San Diego, CA, USA, 2018, p. M1l.7. |
| B. Wang, Z. Huang, X. Zeng, R. Wu, W. V. Sorin, D. Liang, and R. G. Beausoleil | A Compact Model for Si–Ge Avalanche Photodiodes | in Group IV Photonics Kankun, Mexico, 2018. |
| D. Liang, C. Zhang, A. Roshan-Zamir, K. Yu, C. Li, G. Kurczveil, Y. Hu, W. Shen, M. Fiorentino, S. Kumar, S. Palermo, and R. Beausoleil | A Fully-integrated Multi-λ Hybrid DML Transmitter | in OFC San Diego, CA, USA, 2018, p. Th3B.5. |
| A. Seyedi, D. Liang, G. Kurczveil, Z. Huang, M. Fiorentino, and R. Beausoleil | Comb and hybrid laser-driven WDM silicon photonic interconnects for exascale and HPC applications | in SPIE Photonics West San Francisco, CA, USA, 2018, pp. Paper 10538-45. |
| A. Korte, A. Vertes | Complementary Analysis and Quantitation of Metabolites by MALDI- and Silicon Nanopost Array-LDI-MS | Proceedings of the 66th ASMS Conference on Mass Spectrometry and Allied Topics, San Diego, CA, June 3-7, 2018 |
| J.E. Dyer, J.A. Fincher, N.J. Morris, M.J. Powell, D. Jones, V.K. Shanmugam, S. Yadavilli, J. Nazarian, R.K. Pirlo, A. Vertes | Complementary Features of Laser Desorption Ionization from Silicon Nanopost Arrays and MALDI for Mass Spectrometry Imaging | Proceedings of the 66th ASMS Conference on Mass Spectrometry and Allied Topics, San Diego, CA, June 3-7, 2018 |
| Y. Hu, D. Liang, C. Zhang, G. Kurczveil, X. Huang, K. Mukherjee, and R. Beausoleil | Electrically-pumped 1.31 um MQW lasers by direct epitaxy on wafer-bonded InP-on-SOI substrate | in IEEE Photonics Conference Reston, VA, USA, 2018. |
| C. Zhang, D. Liang, G. Kurczveil, A. Descos, and R. G. Beausoleil | Error-Free 12.5 Gb/s Direct Modulation of Low-Threshold Hybrid QD Microring Laser | in ECOC Rome, Italy, 2018. |
| D. Liang, G. Kurczveil, C. Zhang, A. Descos, Y. Hu, M. Fiorentino, and R. Beausoleil | Heterogeneous multi-wavelength quantum-dot light sources on silicon | in European Semiconductor Laser Workshop Bari, Italy, 2018. |
| C. Zhang, D. Liang, G. Kurczveil, and R. G. Beausoleil | High Speed QDs Microring Lasers on Silicon | in ECIO Valencia, Spain, 2018. |
| D. McCulley, E. Minot | Highly efficient carbon nanotube photodiodes enabled by field-enhanced exciton dissociation | (March 2018) Materials Research Society Spring Meeting, Phoenix, AZ |
| Z. Yanga, D. Follman, A.R. Albrecht, P. Heu, G.D. Cole, M. Sheik-Bahae | High-Power DBR-Free Membrane Semiconductor Disk Lasers | CLEO 2018 © OSA 2 |
| B. Tossoun, G. Kurczveil, C. Zhang, D. Liang, and R. G. Beausoleil | High-speed 1310 nm Hybrid Silicon Quantum Dot Photodiodes with Ultra-low Dark Current | in Device Research Conference Santa Barbara, CA, USA, 2018, p. Late Late News paper. |
| D. Liang | Integrated Photonic Interconnect Reliability for Datacom Applications | in Electronic Design Process Symposium Milpitas, CA, USA, 2018. |
| G.D. Cole, D. Follman, P. Heu, G-W. Truong, C. Deutsch, C. Franz, A. Alexandrovski, B. Ma, X. Cheng | Laser-induced damage measurements of crystalline coatings (Conference Presentation) | Proceedings Volume 10805, Laser-Induced Damage in Optical Materials 2018: 50th Anniversary Conference; 108050E (2018) https://doi.org/10.1117/12.2326769
Event: SPIE Laser Damage, 2018, Boulder, Colorado, United States |
| A. Bachtold | Mechanical resonators based on nanotubes and graphene | 2nd Quantum User Meeting 2018 in London, November 2018 (ICFO) |
| A. Bachtold | Mechanical resonators based on nanotubes and graphene | GDRI Graphene and Co in Sète, October 2018 (ICFO) |
| A. Bachtold | Mechanical resonators based on nanotubes and graphene | MRS, Phoenix, April 2018 (ICFO) |
| A. Bachtold | Mechanical resonators based on nanotubes and graphene | Spin mechanics & nanoMRI meeting, Les Houches, February 2018 (ICFO) |
| A. Bachtold | Mechanical resonators based on nanotubes and graphene | TNT2015 in Lecce, September 2018(ICFO) |
| A. Bachtold | Mechanical resonators based on nanotubes and graphene | workshop on Workshop on the interaction of light with quantum and topological materials, Barcelona, June 2018 (ICFO) |
| E. Seker | Nanoporous Gold: From an Ancient Material to Biomedical Devices | IEEE Micro and Nanotechnology in Medicine, Kauai, HI, December 2018. |
| G. Kurczveil, C. Zhang, A. Descos, D. Liang, M. Fiorentino, and R. Beausoleil | On-chip Hybrid Silicon Quantum Dot Comb Laser With 14 Error-Free Channels | in ISLC 2018 Santa Fe, NM, USA, 2018. |
| C. Shang, Y. Wan, D. Jung, J. Norman, M. Kennedy, D. Liang, C. Zhang, A. C. Gossard, and J. E. Bowers | Quantum dot micro-lasers integrated with photodetectors and optical amplifiers on (001) Si via waveguide coupling | in CLEO San Jose, CA, USA, 2018. |
| A. Bushmaker | Rad Hard Thin-Film Flexible Electronics for Spaceflight Applications | Microelectronics Reliability and Qualification Workshop (MRQW), El Segundo, CA (Feb 2018) |
| A. Vertes, A. Arul, P. Avar, A. Korte, C. Lombard-Banek, P. Nemes, L. Parvin, Z. Sahab, B. Shrestha, S.A. Stopka, W. Yuan, D. Bunin, M. Knapp, A. Poggio, C. Talcott, B. Davis, C. Morton, C. Sevinsky, M. Zavodszky | Systems Biology Approach for Mechanism of Action Identification in 30 Days, | Proceedings of the 66th ASMS Conference on Mass Spectrometry and Allied Topics, San Diego, CA, June 3-7, 2018 |
| M. Senger, E. Minot | The relationship between carbon nanotube structure, dielectric environment and physical properties revealed by spectrally-resolved photocurrent microscopy | Materials Research Society Spring Meeting, Phoenix, AZ, (March 2018). |
| W. Shen, D. Liang, C. Zhang, and R. G. Beausoleil | Thermal Management of Hybrid Silicon Microring Laser | in InterPACK San Francisco, CA, USA, 2018. |