Dry Etching Recipes: Difference between revisions

From UCSB Nanofab Wiki
Jump to navigation Jump to search
Content deleted Content added
Ffoong (talk | contribs)
UV Ozone and EVG R levels update
Ffoong (talk | contribs)
Include "organics" for surface treatment
Line 527: Line 527:
|- bgcolor="#ffffff"
|- bgcolor="#ffffff"
!Photoresist
!Photoresist
& ARC
& ARC & Organics
|
|
|[[RIE Etching Recipes|R3]]
|[[RIE Etching Recipes|R3]]

Revision as of 21:24, 9 August 2024

R3Process Control Data

See above linked page for process control data (dep rate/stress etc. over time), for a selection of often-used dry etches

Dry Etching Tools/Materials Table

The Key/Legend for this table's A...R6 values is at the bottom of the page.

Dry Etching Recipes
RIE Etching ICP Etching Oxygen Plasma Systems Other Dry Etchers
Material RIE 2
(MRC)
RIE 5
(PlasmaTherm)
DSEIII
(PlasmaTherm)
Fluorine ICP (PlasmaTherm) ICP Etch 1
(Panasonic E646V)
ICP Etch 2
(Panasonic E626I)
Oxford ICP (PlasmaPro 100) Ashers
(Technics PEII)
Plasma Clean (YES EcoClean) UV Ozone Reactor Plasma Activation
(EVG 810)
XeF2 Etch
(Xetch)
Vapor HF Etch
(uETCH)
CAIBE
(Oxford)
Ag A
Al R2 R1 R2 A
Au R1
Cr R2 R1 R1 A
Cu A
Ge A R1 A A
Mo A
Nb A R1
Ni R1
Os A R1
Pt R1
Ru A R3 A
Si R4 R5 R1 R1 A
Ta A R1 A
Ti R1 R1 A
Al2O3 A R3 A
Al2O3 (Sapphire) R1 R1 A
AlGaAs R3 R1 R3 A
AlGaN R2 A
AlN A
BCB A
CdZnTe R3 A
GaAs R4 R1 R3 R3 A
GaN R4 R1 R1 R2 A
GaSb A R1 R1 A
HfO2 A
InGaAlAs R4 R1 A
InGaAsP R4 R3 A
InP R4 A R1 R6 R1
ITO R4 A
LiNbO3 A
Photoresist

& ARC & Organics

R3 R3 R R3 R3 R3 R3 R3 A
SiC R1 R1 A
SiN R3 R1 R3 R3 A
SiO2 R6 R1 R6 R1 A
SiOxNy A R1 A
SU8 A
Ta2O5 A R1 A
TiN A
TiO2 A
W-TiW R2 R1 R1 A
ZnO2 A
ZnS R3 A
ZnSe R2 A
ZrO2 A
Material RIE 2
(MRC)
RIE 5
(PlasmaTherm)
DSEIII
(PlasmaTherm)
Fluorine ICP (PlasmaTherm) ICP Etch 1
(Panasonic E626I)
ICP Etch 2
(Panasonic E640)
Oxford ICP (PlasmaPro 100) Ashers
(Technics PEII)
Plasma Clean (YES EcoClean) UV Ozone Reactor Plasma Activation
(EVG 810)
XeF2 Etch
(Xetch)
Vapor HF Etch
(uETCH)
CAIBE
(Oxford)

Process Ranking Table

Processes in the table above are ranked by their "Process Maturity Level" as follows:

Process Level Description of Process Level Ranking
A Process Allowed and materials available but never done
R1 Process has been run at least once
R2 Process has been run and/or procedure is documented or/and data available
R3 Process has been run, procedure is documented, and data is available
R4 Process has a documented procedure with regular (≥4x per year) data or lookahead/in-situ control available
R5 Process has a documented procedure with regular (≥4x per year) data and lookahead/in-situ control available
R6 Process has a documented procedure, regular ( ≥4x per year) data, and control charts & limits available