Template:ToolActions: Difference between revisions
Jump to navigation
Jump to search
Content deleted Content added
No edit summary |
{{if}} on ProcessControlURL |
||
| Line 4: | Line 4: | ||
!style="background: Aquamarine;" |[{{{InstructionsURL|{{PAGENAME}}}}} Instructions + Procedures] |
!style="background: Aquamarine;" |[{{{InstructionsURL|{{PAGENAME}}}}} Instructions + Procedures] |
||
|} |
|} |
||
{{#if:{{{ProcessControlURL|}}} |
|||
|- |
|- |
||
| style="padding: 5px;" | |
| style="padding: 5px;" | |
||
{| class="wikitable" style="margin: 0 auto; width: 100%;" |
{| class="wikitable" style="margin: 0 auto; width: 100%;" |
||
!style="background: Aquamarine;" |[{{{ProcessControlURL}}} Process Control Data] |
!style="background: Aquamarine;" | [{{{ProcessControlURL}}} Process Control Data] |
||
|} |
|} |
||
}} |
|||
<hr style="margin-top: 15px;"> |
<hr style="margin-top: 15px;"> |
||
|- |
|- |
||
| Line 33: | Line 35: | ||
!style="background: AliceBlue;" |[https://signupmonkey.ece.ucsb.edu/cgi-bin/users/report-tool-issue.cgi?tool_ID={{{toolid}}} Report Issue] |
!style="background: AliceBlue;" |[https://signupmonkey.ece.ucsb.edu/cgi-bin/users/report-tool-issue.cgi?tool_ID={{{toolid}}} Report Issue] |
||
|} |
|} |
||
|} |
|||
</includeonly><includeonly>[[category:Tools]][[Category:{{{type|NONE}}}]]<br></includeonly><noinclude> |
|||
[[File:TOOL_actions_-_example_image.png|frameless|right|Example of a Tool's Actions Box generated by this "Tool" template.]] |
[[File:TOOL_actions_-_example_image.png|frameless|right|Example of a Tool's Actions Box generated by this "Tool" template.]] |
||
Revision as of 00:57, 6 December 2025
This template inserts a "Tool Actions" panel into a page, with various Buttons for SignUpMonkey actions such as (Report Tool Issue), (Maintenance Records) and links to (Process Control Data) wiki pages.
Copy/paste the following code to include this template in a page. Preferably inserted at the top of the page.
{{ToolActions
|toolid = 51 the Tool ID number from SignupMonkey URL
|ProcessControlURL = https://wiki.nanofab.ucsb.edu/wiki/Stepper_3_(ASML_DUV)#Process_Control_Data
|InstructionsURL = https://wiki.nanofab.ucsb.edu/wiki/Stepper_3_(ASML_DUV)#Operating_Procedures
|TrainingURL = https://wiki.nanofab.ucsb.edu/wiki/Stepper_3_(ASML_DUV)#Video_Training
}}
Options
You can add the following "arguments" in the template.
- Tool ID on SignupMonkey: The |toolid = argument will create a link to the Signup Monkey page for this tool. This is the number at the end of the url for a tool on SignupMonkey.
- ProcessControlURL: (if applicable) URL to the Process Control wiki page.
- InstructionsURL: (if applicable) URL to the SOP's/Instructions wiki page.
- TrainingURL: (if applicable) URL to the SOP's/Instructions wiki page. If omitted, it will go directly to the SUM "request training" page.
Version
2025-12-05 (Demis): first version.