Maskless Aligner (Raith PicoMaster XF): Difference between revisions
No edit summary |
fixed links to recipes, deleted some MLA links etc |
||
| Line 6: | Line 6: | ||
|location = Bay 6 |
|location = Bay 6 |
||
|description = Direct-Write (Maskless) I-Line Photolithography |
|description = Direct-Write (Maskless) I-Line Photolithography |
||
|manufacturer = |
|manufacturer = Raith Gmbh |
||
|model = |
|model = Picomaster XF 200 |
||
|toolid= |
|toolid=104 |
||
|materials = I-Line Photoresists |
|materials = I-Line Photoresists |
||
}} |
}} |
||
{{ToolActions| |
{{ToolActions| |
||
|toolid = |
|toolid = 104 |
||
|InstructionsURL = |
|InstructionsURL = |
||
|ProcessControlURL = |
|ProcessControlURL = |
||
|TrainingURL = |
|TrainingURL = |
||
}} |
}} |
||
{{WIP}} |
{{WIP}} |
||
==About== |
==About== |
||
The |
The Raith PicoMaster XF 200 allows for arbitrary direct-write patterning of I-Line photoresists from an uploaded CAD drawing/file (GDS, DXF, CIF etc.). The system uses a [https://www.siliconlight.com/glv/ Grating Light Valve] ("GLV") for patterning the exposure light-field, to programmatically expose digitized patterns directly onto the sample - no glass photomasks/reticles are required. |
||
Depending on the exposure options and write area, the |
Depending on the exposure options and write area, the PicoMaster is able to expose a 100mm wafer in about 60min, and achieves minimum features sizes around 0.5µm, with overlay/alignment accuracy better than 200nm. |
||
The system has a continuous, automatic autofocus, using optical and pneumatic detection of the substrate surface. |
|||
The software allows for custom drawings and alignment marks to be exposed onto any feature located on the microscope. |
|||
Greyscale lithography allows for photoresist profiles with repeatable slanted or tapered structures, via an 8-bit greyscale bitmap or layer-structured DXF file. See the [[MLA150 - Troubleshooting#Greyscale Lithography Limitations|Greyscale Limitations page]] for more info. |
|||
The high-aspect ratio (variable/long focal length) option enables vertical sidewalls on very thick (~100µm) photoresists. |
|||
[[File:MLA150 Spatial Light Modulator Description.png|alt=Schematic of spatial light modulator exposure technique.|none|thumb|550x600px|Exposure method using a spatial light modulator, continuously moving stage and continuous autofocus. See [https://heidelberg-instruments.com/key-features/maskless-laser-lithography/ HIMT] for more info.]] |
|||
==Detailed Specifications== |
==Detailed Specifications== |
||
{{WIP}} |
{{WIP}} |
||
*Maximum Writeable Area: |
*Maximum Writeable Area: TBD |
||
*Substrate size: |
*Substrate size: 200mm round down to 1cm pieces |
||
| ⚫ | |||
**''Contact staff for pieces < 5 mm.'' |
|||
| ⚫ | |||
*Exposure optics: |
*Exposure optics: |
||
**[https://en.wikipedia.org/wiki/Digital_micromirror_device Digital micromirror device (DMD)] |
**[https://en.wikipedia.org/wiki/Digital_micromirror_device Digital micromirror device (DMD)] |
||
**Laser |
**Laser: 405nm |
||
** |
**Lens NA = TBD |
||
**Lens NA = 0.95 |
|||
*Alignment Accuracy: Global ≤ 500nm; Local ("Field") ≤ 250nm |
*Alignment Accuracy: Global ≤ 500nm; Local ("Field") ≤ 250nm |
||
*Linewidth variation: ≤100nm (relevant to stitched exposure fields) |
*Linewidth variation: ≤100nm (relevant to stitched exposure fields) |
||
*Minimum Features: ~0.40µm line/space demonstrated with 0.5µm-thick PR. Requires additional effort. ≥1µm is relatively straightforward. |
*Minimum Features: ~0.40µm line/space demonstrated with 0.5µm-thick PR. Requires additional effort. ≥1µm is relatively straightforward. |
||
*Write Grid (Address Unit): |
*Write Grid (Address Unit): TBD |
||
**High Quality Mode (std.): 40nm |
|||
**Fast Mode: 100nm |
|||
*Additional manufacturer options: |
*Additional manufacturer options: |
||
| ⚫ | |||
**High-resolution option (Write Mode 1) |
|||
**Extended Focus Range |
|||
**Variable Focal Depth |
|||
**Optical (laser) Autofocus in addition to std. Pneumatic Autofocus |
|||
**Greyscale Mode |
|||
| ⚫ | |||
==Operating Procedures== |
==Operating Procedures== |
||
| Line 68: | Line 50: | ||
**''Includes File-upload procedure, CAD Conversion, Exposure and Alignment.'' |
**''Includes File-upload procedure, CAD Conversion, Exposure and Alignment.'' |
||
**User manuals ''are available at the tool and on the tool's computer.'' |
**User manuals ''are available at the tool and on the tool's computer.'' |
||
*[https://wiki.nanofab.ucsb.edu/w/images/9/95/MLA150_Quick_Start_Rev_B.pdf MLA150 Quick Start Guide **Experienced Users Only**] |
|||
*[https://wiki.nanotech.ucsb.edu/w/images/4/48/MLA150_Substrate_Template_Rules.pdf Substrate Templates] have been updated, reflecting allowed sample sizes for each focus mode. |
|||
=== Video Training === |
|||
*[https://gauchocast.hosted.panopto.com/Panopto/Pages/Viewer.aspx?id=5813cf18-37cb-48f1-aee6-acd50055c65e '''Video Training for MLA150'''] |
|||
**''Bookmarks in the video can point you to specific solutions/procedures.'' |
|||
**'''UPDATES to the Video Training''': ''please review the addendums below:'' |
|||
***New software has been installed, the '''[https://wiki.nanotech.ucsb.edu/w/images/e/ec/MLA150_SOP_Rev_L_%28LS%29.docx.pdf SOP]''' shows the newer menu options. |
|||
***CRITICAL: There are now TWO locations on which you must choose "Optical Autofocus". Failure to do so can result in <u>system damage</u>. |
|||
***[https://wiki.nanotech.ucsb.edu/w/images/4/48/MLA150_Substrate_Template_Rules.pdf Substrate Templates] have been updated, which are currently not reflected in the video. |
|||
***Numerous solved issues have been added to the [[MLA150 - Troubleshooting|'''Troubleshooting page''']]. |
|||
=== Special Procedures === |
|||
*[[Lithography Calibration - Analyzing a Focus-Exposure Matrix|Calibrating your Process with a Focus-Exposure Matrix (FEM)]] - called ''"Series"'' mode on the MLA |
|||
*[[MLA150 - Large Image GDS Generation|Large Image Patterning]] - one way to generate a GDS file out of an arbitrary image (eg. JPG, BMP, PNG etc.) |
|||
===[[MLA150 - Troubleshooting|<u>Troubleshooting & Known Bugs</u>]]=== |
|||
*''See the above page for troubleshooting/recovery info and workarounds to known bugs.'' |
|||
*Double-side polished transparent substrates can sometimes produce difficulties, due to the exposure light reflecting from the wafer underside. Many users have found ways to make them work properly - contact [[Demis D. John|staff]] if you need help with this. |
|||
===Training Procedure=== |
===Training Procedure=== |
||
To get authorized on this tool: |
To get authorized on this tool: {{ToolTrainingButton|toolid=32}} |
||
#please study the training videos here: '''[https://gauchocast.hosted.panopto.com/Panopto/Pages/Viewer.aspx?id=5813cf18-37cb-48f1-aee6-acd50055c65e Heidelberg MLA150 Training Video]''' |
|||
#"shadow" experienced users in your group, if you have any, and |
|||
#when you are ready, click this button to request training:{{ToolTrainingButton|toolid=32}} |
|||
==Design Info - CAD layout== |
==Design Info - CAD layout== |
||
{{WIP}} |
|||
*[[MLA150 - Design Guidelines|Design Guidelines + Tips]] - ''Important info for designing your CAD files, alignment marks etc.'' |
*[[MLA150 - Design Guidelines|Design Guidelines + Tips]] - ''Important info for designing your CAD files, alignment marks etc.'' |
||
*[[MLA150 - CAD Files and Templates|CAD Files and Templates]] - ''example CAD designs and useful CAD structures.'' |
*[[MLA150 - CAD Files and Templates|CAD Files and Templates]] - ''example CAD designs and useful CAD structures.'' |
||
| Line 104: | Line 63: | ||
==Recipes== |
==Recipes== |
||
{{WIP}} |
{{WIP}} |
||
*'''Recipes > Lithography >''' '''<u>[[ |
*'''Recipes > Lithography >''' '''<u>[[Direct-Write_Lithography_Recipes#Maskless_Aligner_(Raith_PicoMasterXF)]]</u>''' |
||
**''Starting recipes for various I-Line photoresists'' |
**''Starting recipes for various I-Line photoresists'' |
||
Latest revision as of 20:07, 30 September 2026
| ||||||||||||||||||||||||||||||||||
| |
| |
|
| |
| |
|
Work In Progress This article is still under construction. It may contain factual errors. Content is subject to change. |
About
The Raith PicoMaster XF 200 allows for arbitrary direct-write patterning of I-Line photoresists from an uploaded CAD drawing/file (GDS, DXF, CIF etc.). The system uses a Grating Light Valve ("GLV") for patterning the exposure light-field, to programmatically expose digitized patterns directly onto the sample - no glass photomasks/reticles are required.
Depending on the exposure options and write area, the PicoMaster is able to expose a 100mm wafer in about 60min, and achieves minimum features sizes around 0.5µm, with overlay/alignment accuracy better than 200nm.
Detailed Specifications
Work In Progress This article is still under construction. It may contain factual errors. Content is subject to change. |
- Maximum Writeable Area: TBD
- Substrate size: 200mm round down to 1cm pieces
- Wafer / substrate thickness: Max. / Min. TBD
- Exposure optics:
- Digital micromirror device (DMD)
- Laser: 405nm
- Lens NA = TBD
- Alignment Accuracy: Global ≤ 500nm; Local ("Field") ≤ 250nm
- Linewidth variation: ≤100nm (relevant to stitched exposure fields)
- Minimum Features: ~0.40µm line/space demonstrated with 0.5µm-thick PR. Requires additional effort. ≥1µm is relatively straightforward.
- Write Grid (Address Unit): TBD
- Additional manufacturer options:
- Backside alignment
Operating Procedures
Work In Progress This article is still under construction. It may contain factual errors. Content is subject to change. |
Standard Operating Procedures
- PicoMaster XF 200- Standard Operating Procedure - updated Sept 26th 2026
- Includes File-upload procedure, CAD Conversion, Exposure and Alignment.
- User manuals are available at the tool and on the tool's computer.
Training Procedure
To get authorized on this tool:
| Request Training |
|---|
Design Info - CAD layout
Work In Progress This article is still under construction. It may contain factual errors. Content is subject to change. |
- Design Guidelines + Tips - Important info for designing your CAD files, alignment marks etc.
- CAD Files and Templates - example CAD designs and useful CAD structures.
Recipes
Work In Progress This article is still under construction. It may contain factual errors. Content is subject to change. |
- Recipes > Lithography > Direct-Write_Lithography_Recipes#Maskless_Aligner_(Raith_PicoMasterXF)
- Starting recipes for various I-Line photoresists
Calibrate your own Litho process
- Use Series mode exposure for doing an FEM ("Focus-Exposure Matrix") on the MLA150.
- Lithography Calibration - Analyzing a Focus-Exposure Matrix - how to analyze an FEM for repeatable processes
Litho. recipes for all our photolith. tools can be found on the Photolithography Recipes page.
