Automated Coat/Develop System (S-Cubed Flexi)

From UCSB Nanofab Wiki
Revision as of 21:41, 8 November 2022 by John d (talk | contribs) (link to recipes table)
Jump to navigation Jump to search
Automated Coat/Develop System (S-Cubed Flexi)
TBD.jpg
Location Bay 7
Tool Type Wet Processing
Manufacturer S-Cubed
Model Flexi (Custom)
Description Automatic Coat/Bake/Develop

Primary Supervisor Tony Bosch
(805) 893-3486
bosch@ece.ucsb.edu

Secondary Supervisor

Lee Sawyer


Recipes Wet Processing Recipes

SignupMonkey: Sign up for this tool


This Tool is now available for training - please contact the supervisor. 2022-11-01

About

The S3-Coater is a Coater/Developer system that has one photoresist spinner, one developer spinner and 4 hotplates each with independent temperature control and a chill plate. A central robot picks your wafer/s from one of 2 cassettes, processes them and returns them to the cassette. The system is recipe driven with a high degree of process control and minimal backside contamination, and coats photoresists with low particle counts/streaks and high uniformity.

At this time only full size substrates are allowed on this system. The S3 Coater is still in process development and not open for general use.

Detailed Specifications

  • Wafer Size: 100mm (150mm possible but not set up)
  • PR Coating Properties:
    • Uniformity < 1.0%
    • < 100 particles on 100mm wafer
  • Photoresists/Underlayers Available:
    • UV6-0.8
    • DS-K101-304
    • PMMA - NOT FOR PUBLIC USE AT THIS TIME
    • PMGI SF11 - NOT FOR GENERAL USE AT THIS TIME
    • PMGI SF5 - NOT FOR GENERAL USE AT THIS TIME
  • Solvents Available:
    • EBR100 (wafer backside cleaning)
  • Developers Available:
    • AZ 300 MiF - NOT FOR GENERAL USE AT THIS TIME

Process Information

Operating Procedures

Recipes

Recipes > Lithography > Automated Coater Recipes - See all available spin-coat recipes for this machine. Only Staff may edit/create recipes.