Maskless Aligner (Raith PicoMaster XF)

From UCSB Nanofab Wiki
Revision as of 19:03, 18 July 2026 by John d (talk | contribs) (added WIP notices)
Jump to navigation Jump to search
Maskless Aligner (Raith PicoMaster XF)
File:XYZ.jpg
Location Bay 6
Tool Type Lithography
Manufacturer ?
Model ?
Description Direct-Write (Maskless) I-Line Photolithography

Primary Supervisor Biljana Stamenic
(805) 893-4002
biljana@ece.ucsb.edu

Secondary Supervisor

Lee Sawyer


Materials I-Line Photoresists
Recipes

SignupMonkey: Sign up for this tool


Instructions + Procedures

Sign Up

Get Trained

Maintenance
Messages
Report Issue



Work In Progress

This article is still under construction. It may contain factual errors. Content is subject to change.


About

The MLA150 allows for arbitrary direct-write patterning of I-Line photoresists from an uploaded CAD drawing/file (GDS, DXF, CIF etc.). The system uses a digital micromirror device ("DMD", an array of MEMS mirrors) for patterning the exposure light-field, to programmatically expose digitized patterns directly onto the sample - no glass photomasks/reticles are required.

Depending on the exposure options and write area, the MLA is able to expose a 100mm wafer in about 30min, and achieves minimum features sizes around 0.5µm, with overlay/alignment accuracy better than 200nm.

The system has a continuous, automatic autofocus, using optical and pneumatic detection of the substrate surface.

The software allows for custom drawings and alignment marks to be exposed onto any feature located on the microscope.

Greyscale lithography allows for photoresist profiles with repeatable slanted or tapered structures, via an 8-bit greyscale bitmap or layer-structured DXF file. See the Greyscale Limitations page for more info.

The high-aspect ratio (variable/long focal length) option enables vertical sidewalls on very thick (~100µm) photoresists.

Schematic of spatial light modulator exposure technique.
Exposure method using a spatial light modulator, continuously moving stage and continuous autofocus. See HIMT for more info.

Detailed Specifications


Work In Progress

This article is still under construction. It may contain factual errors. Content is subject to change.


  • Maximum Writeable Area: 150 x 150mm
  • Substrate size: 9-inch square or 200mm round down to 5-mm pieces
    • Contact staff for pieces < 5 mm.
  • Wafer / substrate thickness: Max. 9mm / Min. 0.1mm
  • Exposure optics:
  • Alignment Accuracy: Global ≤ 500nm; Local ("Field") ≤ 250nm
  • Linewidth variation: ≤100nm (relevant to stitched exposure fields)
  • Minimum Features: ~0.40µm line/space demonstrated with 0.5µm-thick PR. Requires additional effort. ≥1µm is relatively straightforward.
  • Write Grid (Address Unit):
    • High Quality Mode (std.): 40nm
    • Fast Mode: 100nm
  • Additional manufacturer options:
    • High-resolution option (Write Mode 1)
    • Extended Focus Range
    • Variable Focal Depth
    • Optical (laser) Autofocus in addition to std. Pneumatic Autofocus
    • Greyscale Mode
    • (No backside alignment)

Operating Procedures


Work In Progress

This article is still under construction. It may contain factual errors. Content is subject to change.


Standard Operating Procedures

Video Training

  • Video Training for MLA150
    • Bookmarks in the video can point you to specific solutions/procedures.
    • UPDATES to the Video Training: please review the addendums below:
      • New software has been installed, the SOP shows the newer menu options.
      • CRITICAL: There are now TWO locations on which you must choose "Optical Autofocus". Failure to do so can result in system damage.
      • Substrate Templates have been updated, which are currently not reflected in the video.
      • Numerous solved issues have been added to the Troubleshooting page.

Special Procedures

Troubleshooting & Known Bugs

  • See the above page for troubleshooting/recovery info and workarounds to known bugs.
  • Double-side polished transparent substrates can sometimes produce difficulties, due to the exposure light reflecting from the wafer underside. Many users have found ways to make them work properly - contact staff if you need help with this.

Training Procedure

To get authorized on this tool:

  1. please study the training videos here: Heidelberg MLA150 Training Video
  2. "shadow" experienced users in your group, if you have any, and
  3. when you are ready, click this button to request training:
Request Training


Design Info - CAD layout

Recipes


Work In Progress

This article is still under construction. It may contain factual errors. Content is subject to change.


Calibrate your own Litho process

Litho. recipes for all our photolith. tools can be found on the Photolithography Recipes page.