PubList2018

From UCSB Nanofab Wiki
Revision as of 23:49, 3 September 2019 by Thibeault (talk | contribs) (Added all 2018 pub lists)
Jump to navigation Jump to search

Internal Users - Journal Publications

Authors Title Publications
J. Duan, H. Huang, B. Dong, D. Jung, J.C. Norman, J.E. Bowers, F. Grillot 1.3-um Reflection Insensitive InAs/GaAs Quantum Dot Lasers Directly Grown on Silicon Submitted to Photonics Technology Letters (2018).
J.S.  Lee, S. Choi, M. Pendharkar, D.J. Pennachio, B. Markman, M. Seas, S. Koelling, M.A. Verheijen,L. Casparis, K.D. Petersson, I. Petkovic, V. Schaller, M.J.W. Rodwell, C.M. Marcus, P.Krogstrup, L.P. Kouwenhoven, E.P.A.M. Bakkers, C.J. Palmstrøm 1Selective-area chemical beam epitaxy of in-plane InAs one-dimensional channels grown on InP(001),InP(111)B, and InP(110) surfaces arXiv preprint arXiv:1808.04563
S. Liu, D. Jung, J. C. Norman, MJ Kennedy, A. C. Gossard, J. E. Bowers 490 fs pulse generation from passively mode-locked single section quantum dot laser directly grown on on-axis GaP/Si Electronics Letters, (54)7, 432-433, March 19, 2018.
C. Neill, P. Roushan, K. Kechedzhi, S. Boixo, S. V. Isakov, V. Smelyanskiy, R. Barends, B. Burkett, Y. Chen, Z. Chen, B. Chiaro, A. Dunsworth, A. Fowler, B. Foxen, R.Graff, E. Jeffrey, J. Kelly, E. Lucero, A. Megrant, J. Mutus, M. Neeley, C. Quintana, D. Sank, A. Vainsencher, J. Wenner, T. C. White, H. Neven, J. M. Martinis A blueprint for demonstrating quantum supremacy with superconducting qubits Science 360, Issue 6385, 195-199 (2018).   arXiv:1709.06678
M. Garcia, B. Ganapathysubramanian, S. Pennathur A linearised model for calculating inertial forces on a particle in the presence of a permeate flow Journal of Fluid Mechanics. 2019 Feb;861:253-74.  
H. Kim, L. Theogarajan, S. Pennathur A repeatable and scalable fabrication method for sharp, hollow silicon microneedles Journal of Micromechanics and Microengineering, Vol. 28, No. 3, January 2018.
K.H. Chou, C. McCallum, D. Gillespie, S. Pennathur An experimental approach to systematically probe charge inversion in nanofluidic channels Nano letters. 2018 Jan 11;18(2):1191-5.  
D. T. Spencer, T. Drake, T. C. Briles, J. Stone, L. C. Sinclair, C. Fredrick, Q. Li, D. Westly, B. Robert Ilic, A. Bluestone, N. Volet, T. Komljenovic, L. Chang, S. H. Lee, D. Y. Oh, M.-G. Suh, K. Y. Yang, M. H. P. Pfeiffer, T. J. Kippenberg, E. Norberg, L. Theogarajan, K. Vahala, N. R. Newbury, K. Srinivasan, J. E. Bowers, S.A. Diddams, S. B. Papp An Integrated-Photonics Optical-Frequency Synthesizer Nature Photonics, 557, 81-85, April 25, 2018.
X. Zheng, H. Li, M. Guidry, B. Romanczyk , E. Ahmadi, K. Hestroffer, S. Wienecke , S. Keller, U.K. Mishra Analysis of MOCVD SiNx Passivated N-Polar GaN MIS-HEMTs on Sapphire With High fmax·VDS,Q, IEEE Electron Device Letters, Vol. 39, No. 3, March 2018
H. Huang, J. Duan, D. Jung, A. Liu, Z. Zhang, J. Norman, J. E. Bowers, F. Grillot Analysis of the optical feedback dynamics in InAs/GaAs quantum dot lasers directly grown on silicon Journal of the Optical Society of America B, (35)11, 2780-2787, October 12, 2018.
A.C. Espenlaub, A.I. Alhassan, S. Nakamura, C. Weisbuch, J.S. Speck Auger-generated hot carrier current in photo-excited forward biased single quantum well blue light emitting diodes Appl. Phys. Lett. 112, 141106, 2018.
N.A. Butakov, M.W. Knight, T.Lewi, P.P. Iyer, D. Higgs, H.T. Chorsi, J. Trastoy, J.D.V. Grande, I. Valmianski, C. Urban, Y. Kalcheim, P.Y. Wang, P.W.C. Hon, I.K. Schuller, J.A. Schuller

 

Broadband Electrically Tunable Dielectric Resonators Using Metal-Insulator Transitions ACS Photonics 5, pp.  4054-4060 Journal
P. Li, B. Bonef, M. Khoury, G. Lheureux,H. Li, J. Kang, S. Nakamura, S.P. DenBaars Carrier dynamics of two distinct localized centers in 530 nm InGaN green light-emitting diodes Superlattices and Microstructures 113  684-689
K. Ahadi,Z. Gui, Z. Porter, J. W. Lynn, Z. Xu, S. D. Wilson, A. Janotti, S. Stemmer Carrier Density Control of Magnetism and Berry Phases in Doped EuTiO3 APL Mater. 6, 056105 (2018).
S. Liu, T. Komljenovic, S. Srinivasan, E. Norberg, G. Fish, J. E. Bowers Characterization of a fully integrated heterogeneous silicon/III-V colliding pulse mode-locked laser with on-chip feedback Optics Express, (26)8, 9714-9723, April 4, 2018.
M.J. Weaver, F.Buters, F.Luna, H.Eerkens, K. Heeck, S. de Man, D.Bouwmeester Coherent optomechanical state transfer between disparate mechanical resonators Nature Communicationsvolume 8, Article number: 824 (2017)
S.H. Chan, D.Bisi, M. Tahhan, C. Gupta, S.P. DenBaars, S. Keller, E. Zanoni, U.K. Mishra Comparing electrical characteristics of in situ and ex situ Al2O3/GaN interfaces formed by metalorganic chemical vapor deposition Applied Physics Express, Vol. 11, No. 4, 13 March 2018
D.L. Becerra, D.A. Cohen, S. Mehari, S.P. DenBaars, S. Nakamura Compensation effects of high oxygen levels in semipolar AlGaN electron blocking layers and their mitigation via growth optimization Journal of Crystal Growth 507  118–123
C.A. Forman, S.G. Lee, E.C. Young, J.A. Kearns, D.A. Cohen, J.T. Leonard, T. Margalith, S.P. DenBaars,S. Nakamura Continuous-wave operation of m-plane GaN-based vertical-cavity surface-emitting lasers with a tunnel junction intracavity contact Applied Physics Letters, Vol. 112, Issue 11, 2018.
S.R. Meeker, B.A. Mazin, A.B. Walter, P. Strader, N.Fruitwala, C. Bockstiegel, P. Szypryt, G. Ulbricht, G. Coiffard, B. Bumble, G. Cancelo, T. Zmuda, K. Treptow, N. Wilcer, G. Collura, R. Dodkins, I. Lipartito, N. Zobrist, M. Bottom, J. C. Shelton, D. Mawet, J.C. van Eyken, G. Vasisht, E. Serabyn DARKNESS: A Microwave Kinetic Inductance Detector Integral Field Spectrograph for High-contrast Astronomy Astronomical Society of the Pacific, Volume 130, Issue 988, pp. 065001 (2018).
M. Buffolo, M. Pietrobon, C. De Santi, F. Samparisi, M. L. Davenport, J. E. Bowers, G. Meneghesso, E. Zanoni, M. Meneghini Degradation mechanisms of heterogeneous III-V/Silicon loop-mirror laser diodes for photonic integrated circuits Microelectronics Reliability, 88-90, 855-858, September 30, 2018.
B. Romanczyk, S. Wienecke, M. Guidry, H. Li, E. Ahmadi, X. Zheng, S. Keller, U.K. Mishra Demonstration of Constant 8 W/mm Power Density at 10, 30, and 94 GHz in State-of-the-Art Millimeter-Wave N-Polar GaN MISHEMTs IEEE Transactions On Electron Devices, Vol. 65, No. 1, Jan 2018
S. Mehari, D.A. Cohen, D.L. Becerra, S. Nakamura, S.P. DenBaars Demonstration of enhanced continuous-wave operation of blue laser diodes on a semipolar 20(21)over-bar GaN substrate using indium-tin-oxide/thin-p-GaN cladding layers Optics Express, Vol. 26, Issue 2,1564 2018.
A.I. Alhassan, N.G. Young, R.M. Farrell, C. Pynn, F. Wu, A.Y. Alyamani, S. Nakamura, S.P. Denbaars, J.S. Speck Development of high performance green c-plane III-nitride light-emitting diodes Optics express, vol. 26, no. 5: Optical Society of America, pp. 5591–5601, 2018.
B. Saifaddin, C. J. Zollner, A. Almogbel, H. Foronda, F. Wu, A. Albadri, A. Al Yamani, M. Iza, S. Nakamura, S. P. DenBaars, et al. Developments in AlGaN and UV-C LEDs grown on SiC Light-Emitting Diodes: Materials, Devices, and Applications for Solid State Lighting XXII, vol. 10554: International Society for Optics and Photonics, pp. 105541E, 2018.
R. Salemmilani, B.D. Piorek, A.W. FountainIII, M. Moskovits, C.D. Meinhart Dielectrophoretic Nanoparticle Aggregation for On-Demand Surface Enhanced Raman Spectroscopy Analysis Anal. Chem.201890137930-7936

Publication Date:June 4, 2018

W. Xie, J. Huang, T. Komljenovic, L. Coldren, J. Bowers Diffraction Limit in Centimeter Scale: Metasurface Grating Antenna for Phased Array LiDAR arXiv, arXiv:1810.00106, September 28, 2018.
D. Inoue, D. Jung, J. Norman, Y. Wan, N. Nishiyama, S. Arai, A. C. Gossard, J. E. Bowers Directly modulated 1.3 μm quantum dot lasers epitaxially grown on silicon Optics Express, (26)6, 7022-7033, March 7, 2018.
Y. Wan, D. Inoue, D. Jung, J.C. Norman, C. Shang, A.C. Gossard, J.E. Bowers Directly modulated quantum dot lasers on silicon with a milliampere threshold and high temperature stability Photonics Research Vol. 6, Issue 8, pp. 776-781 (2018) •https://doi.org/10.1364/PRJ.6.000776
D. Jung, D.J. Ironside, S.R. Bank, A.C. Gossard, J.E. Bowers Effect of growth interruption in 1.55 μm InAs/InAlGaAs quantum dots on InP grown by molecular beam epitaxy Journal of Applied Physics 123, 205302 (2018); https://doi.org/10.1063/1.5031772
J. Kim, H. Kim, M. E. Kilic, C. Gayner, R. Koltun, H. Park, A. Soon, J. Bowers, C. Palmstrøm, W. Kim Effect of phonon confinement on the thermal conductivity of In0.53Ga0.47As nanofilms Journal of Applied Physics, 123, 245103, June 25, 2018.
Z. Zhang, D. Jung, J. C. Norman, P. Patel, W. W. Chow, J. E. Bowers Effects of modulation p doping in InAs quantum dot lasers on silicon Applied Physics Letters, 113, 061105, August 7, 2018.
P. B. Marshall, K. Ahadi, H. Kim, S. Stemmer Electron nematic fluid in a strained Sr3Ru2O7 film Phys. Rev. B 97, 155160 (2018).
J. A. Frey, H. J. Snijders, J. Norman, A. C. Gossard, J. E. Bowers, W. Loffler, D. Bouwmeester Electro-optic polarization tuning of microcavities with a single quantum dot Optics letters 43 (17), 4280-4283
J. A. Frey, H. J. Snijders, J. Norman, A. C. Gossard, J. E. Bowers, W. Lӧffler, D. Bouwmeester Electro-optic tuning of microcavities with a single quantum dot arXiv, arXiv:1805.03387, May 9, 2018.
A. A. Zibrov, R. Peng, C. Kometter, J.I.A. Li, C. R. Dean, T. Taniguchi, K. Watanabe, M. Serbyn, A. F. Young Emergent Dirac gullies and gully nematic quantum Hall states in ABA trilayer graphene Physical Review Letters  121, 167601.
C. Conner, T. de Visser, J. Loessberg, S. Sherman, A. Smith, S. Ma, M.T. Napoli, S. Pennathur, D. Weld Energy Harvesting with a Liquid-Metal Microfluidic Influence Machine Phys. Rev. Applied 9, 044008 (2018)
H. Li, S. Wienecke, B. Romanczyk, E. Ahmadi, M. Guidry, X. Zheng, S. Keller, U.K. Mishra Enhanced mobility in vertically scaled N-polar high-electron-mobility transistors using GaN/InGaN composite channels Applied Physics Letters, Vol. 112, No. 7, 13 Feb 2018
A. A. Zibrov,E.M.Spanton, H.Zhou, C. Kometter, T. Taniguchi, K. Watanabe, A.F. Young Even denominator fractional quantum Hall states at an isospin transition in monolayer graphene Nature Physics 14, 930-935 (2018).
H. Snijders, J. A. Frey, J. Norman, V. P. Post, A. C. Gossard, J. E. Bowers, M. P. van Exter, W. Löffler, D. Bouwmeester Fiber-coupled Cavity-QED Source of Identical Single Photons Physical Review Applied,  9, 031002, March 28, 2018.
P. V. Klimov, J. Kelly, J. Chen, M. Neeley, A. Megrant, B. Burkett, R. Barends, K. Arya, B. Chiaro, Y. Chen, A. Dunsworth, A. Fowler, B. Foxen, C. Gidney, M. Giustina, R. Graff, T. Huang, E. Jeffrey, Erik Lucero, J. Mutus, O. Naaman, C. Neill, C. Quintana, P. Roushan, Daniel Sank, A. Vainsencher, J. Wenner, T. White, S. Boixo, R. Babbush, V. Smelyanskiy, H. Neven, John M. Martinis Fluctuations of Energy-Relaxation Times in Superconducting Qubits arXiv:1809.01043, September 2018
K. Scida, A. Eden, N. Arroyo-Curras, S. MacKenzie, Y. Satik, C.D. Meinhart, J.C. Eijkel, S. Pennathur Fluorescence-Based Observation of Transient Electrochemical and Electrokinetic Effects at Nanoconfined Bipolar Electrodes ACS applied materials & interfaces. 2019 Mar 18.
R.-L. Chao, L. Liang, J.-W. Shi, T. Komljenovic, J. Hulme, M. J. Kennedy, J. E. Bowers Fully Integrated Photonic Millimeter-Wave Tracking Generators on Heterogeneous III-V/Si Platform IEEE Photonics Technology Letters, (30)10, 919-922, April 10, 2018.
S.G. Lee, C.A. Forman, C. Lee, J. Kearns, E.C. Young, J.T. Leonard, D.A. Cohen, J.S. Speck, S. Nakamura, S.P. DenBaars GaN-based vertical-cavity surface-emitting lasers with tunnel junction contacts grown by metal-organic chemical vapor deposition Applied Physics Express, Vol. 11, Issue 6, 062703, 2018.
M.N. Fireman, H. Li, S. Keller, U. K. Mishra, J. S. Speck Growth of N-polar GaN by ammonia molecular beam epitaxy Journal of Crystal Growth, vol. 481: North-Holland, pp. 65–70, 2018.
H. Nili, G.C. Adam, B. Hoskins, M. Prezioso, J. Kim, M.R. Mahmoodi, F. Merrikh Bayat, O. Kavehei, D.B. Strukov Hardware-intrinsic security primitives enabled by analogue state and nonlinear conductance variations in integrated memristors Nature Electronics 1, pp. 197–202, 2018 (Journal Cover).
J.E. Bowers, L. Chang Heterogeneous integration for optical signal processing Roadmap on Optical Signal Processing submitted (2018).
M. L. Davenport, M. A. Tran, T. Komljenovic, J. E. Bowers Heterogeneous Integration of III-V lasers on Si by Bonding Book Chapter 6, Semiconductors and Semimetals, Vol. 99, Academic Press, October 8, 2018.
W. Xie, T. Komljenovic, J. Huang, M. Tran, M.L. Davenport, A. Torres, P. Pintus,  J. Bowers Heterogeneous Silicon Photonics Sensing for Autonomous Cars Optics Express (2018).
L. Chang, A. Boes, X. Guo, D. T. Spencer, MJ. Kennedy, J. D. Peters, N. Volet, J. Chiles, A. Kowligy, N. Nader,  D. D. Hickstein, E. J. Stanton, S. A. Diddams, S. B. Papp, J. E. Bowers Heterogeneously Integrated GaAs waveguides on Insulator for Efficient Frequency Conversion Laser and Photonics Reviews, (12)10, 1800149, August 14, 2018.
R. Jones, P. Doussiere, J. B. Driscoll, W. Lin, H. Yu, Y. Akulova, T. Komljenovic, J. E. Bowers Heterogeneously Integrated Photonics Nanotechnology Magazine (2018).
M.S. Wong, D. Hwang, A.I. Alhassan, C. Lee, R. Ley, S. Nakamura, S.P. DenBaars High efficiency of III-nitride micro-light-emitting diodes by sidewall passivation using atomic layer deposition Optics Express, Vol. 26, Issue 16, 2018.
R. Helkey, A. Saleh, J. Buckwalter, J.E. Bowers High Performance Photonic Integrated Circuits on Silicon JSTQE Dec. 2018.
J.C. Norman, D. Jung, Z. Zhang, Y. Wan, S. Liu, C. Shang, R.W. Herrick, W.W. Chow, A.C. Gossard, J.E. Bowers High Performance Quantum Dot Lasers on Silicon JQE Sept 2018.
B.P. Yonkee, E.C. Young, S.P. DenBaars, J.S. Speck, S. Nakamura High reflectivity Ohmic contacts to n-GaN utilizing vacuum annealed aluminum Semiconductor Science and Technology, Vol. 33, Issue 1, 015015, 2018.
N. Arroyo-Curras, K. Scida, K.L. Ploense, T.E. Kippin, K.W. Plaxco High Surface Area Electrodes Generated via Electrochemical Roughening Improve the Signaling of Electrochemical Aptamer-Based Biosensors Anal. Chem. 2017, 89, 12185-12191.
B.E. Tew, P. Vempati, L.E. Clinger, N.I. Halaszynski, Gilles, Pernot, T. Favaloro, C.C. Bomberger, A. Shakouri, J.E. Bowers, J-H. Bahk,  J. M. O. Zide High Thermoelectric Power Factor and ZT in TbAs:InGaAs EpitaxialNanocomposite Material submitted High Thermoelectric Power Factor (2018).
S. Liu, X. Wu, D. Jung, J.C. Norman, M. Kennedy, H.K. Tsang, A.C. Gossard, J.E. Bowers High-channel-count low-noise 20 GHz passively mode locked quantum dot laser directly grown on Si with 4.1 Tbit/s transmission capacity submitted to Optica (2018).
C. Weisbuch Historical perspective on the physics of artificial lighting Comptes Rendus Physique 19, 3, 2018.
D.J. Myers, , K. Gelžinytė, W. Ying Ho, J. Iveland, L. Martinelli, J. Peretti, C. Weisbuch, J. S. Speck Identification of low-energy peaks in electron emission spectroscopy of InGaN/GaN light-emitting diodes Journal of Applied Physics, vol. 124, pp. 055703, 2018.
R. Hermann, M.J. Gordon Imaging Intermolecular Exciton Coupling in Metal-Free Phthalocyanine Nanofilms Using Tip-Enhanced Near-Field Optical Microscopy J. Phys. Chem. C 2018, 122, 26, 14796-14804.
M. Monovarian, A. Rashidi, A. A. Aragon, S. H. Oh, A. K. Rishinaramangalam, Steven P. DenBaars, D. Feezell Impact of crystal orientation on the modulation bandwidth of InGaN/GaN light-emitting diodes Applied Physics Letters, 2018.
D. Jung, R. Herrick, J. Norman, K. Turnlund, C. Jan, K. Feng, A. C. Gossard, J. E. Bowers Impact of threading dislocation density on the lifetime of InAs quantum dot laser on Si Applied Physics Letters, 112, 153507, April 13, 2018.
F. Merrikh Bayat, M. Prezioso, B. Chakrabarti, H. Nili, I. Kataeva, D. Strukov Implementation of multilayer perceptron network with highly uniform passive memristive crossbar circuits Nature Communications 9, art. 2331, 2018.
M. L. Davenport, S. Liu, J. E. Bowers Integrated heterogeneous silicon/III-V mode-locked lasers Photonics Research, (6)5, 468-478, April 20, 2018.
T. A. Huffman, G. M. Brodnik, C. Pinho, S. Gundavarapu, D. Baney, D. J. Blumenthal Integrated Resonators in an Ultralow Loss Si3N4/SiO2 Platform for Multifunction Applications IEEE Journal of Selected Topics in Quantum Electronics, vol. 24, no. 4, pp. 1-9, July-Aug (2018).
Y. Liu et al. Integrated Silicon Nitride Optical Beamforming Networks for Wideband Communications Integrated Photonics Research, Silicon and Nanophotonics, 2018, p. ITh3B–4.
P. Bhasker, J. Norman, J. Bowers, N. Dagli Intensity and Phase Modulators at 1.55 μm in GaAs/AlGaAs Layers Directly Grown on Silicon IEEE/OSA J. of Lightwave Technology, vol. LT-36, No. 18, pp. 4205-4210, September 15, 2018.
A. Spott, E. J. Stanton, A. Torres, M. L. Davenport, C. L. Canedy, I. Vurgaftman, M. Kim, C. S. Kim, C. D. Merritt, W. W. Bewley, J. R. Meyer, J. E. Bowers Interband Cascade Laser on Silicon Optica, (5)8, 996-1005, August 16, 2018.
C-C. Chang, A. Nowbahar, V. Mansard, I. Williams, J. Mecca, A. Schmitt, T. Kalantar, T-C. Kuo, T.M. Squires Interfacial rheology and heterogeneity of aging asphaltene layers at the water-oil interface Langmuir , 34, 5409−5415 (2018) 10.1021/acs.langmuir.8b00176.
S. Gundavarapu, M. Belt, T.A. Huffman, M.A. Tran, T. Komljenovic, J.E. Bowers, D.J. Blumenthal Interferometric Optical Gyroscope Based on an Integrated Si3N4 Low-Loss Waveguide Coil J. Lightwave Technol. 36, 1185-1191 (2018).
D. Feezell, S. Nakamura Invention, development, and status of the blue light-emitting diode, the enabler of solid-state lighting C.R.Physique 19 113–133
C. Lund, A. Agarwal, B. Romanczyk, T. Mates, S. Nakamura, S.P. Denbaars, U.K. Mishra, S. Keller Investigation of Mg delta-doping for low resistance N-polar p-GaN films grown at reduced temperatures by MOCVD Semiconductor Science and Technology, Vol. 33, Issue 9, 2018.
B.A. Mazin, G.D. Becker, G. Cancelo, K. France, W.C. Fraser, T. Jones, S.R. Meeker, K. O'Brien, J.X. Prochaska, S. Tendulkar, G. Vasisht KRAKENS: a superconducting MKID integral field spectrograph concept for the Keck I telescope SPIE, Volume 10702, id. 107020H 20 pp. (2018).
C. Weisbuch, E. Spitz, A. David LEDs: The new revolution in lighting Foreword Comptes Rendus Physique 19, 3, 2018.
J. Wu,Y. Fang, B. Markman, H-Y. Tseng, M.J. W. Rodwell, Lg=30 nm InAs Channel MOSFETs Exhibitingfmax=410 GHz andft=357 GHz IEEE ELECTRON DEVICE LETTERS, VOL. 39, NO. 4, APRIL 2018
K. Sun, D. Jung, C. Shang, A. Liu, J. Morgan, J. Zang, Q. Li, J. Klamkin, J. E. Bowers, A. Beling Low dark current III–V on silicon photodiodes by heteroepitaxy Optics Express, (26)10, 13605-13613, May 11, 2018.
D. Inoue, Y. Wan, D. Jung, J. Norman, C. Shang, N. Nishiyama, S. Arai, A. C. Gossard, J. E. Bowers Low-dark current 10 Gbit/s operation of InAs/InGaAs quantum dot p-i-n photodiode grown on on-axis (001) GaP/Si Applied Physics Letters, 113, 093506, August 30, 2018.
Y. Liu, B. Isaac, J. Kalkavage, E. Adles, T. Clark, J. Klamkin Low-loss silicon nitride integrated optical beamforming network for wideband communication Terahertz, RF, Millimeter, and Submillimeter-Wave Technology and Applications XI, 2018, vol. 10531, p. 1053 118.
Y. Wan, D. Jung, C. Shang, N. Collins, I. MacFarlane, J. Norman, M. Dumont, A. C. Gossard, J. E. Bowers Low-Threshold Continuous-Wave Operation of Electrically-Pumped 1.55 μm InAs Quantum Dash Microring Lasers ACS Photonics, December 26, 2018.
A. Nowbahar, V. Mansard, J.  Mecca, M. Paul, T.  Arrowood, T. M. Squires Measuring Interfacial Polymerization Kinetics Using Microfluidic Interferometry J. Am. Chem. Soc. 140 , 3173 - 3176 (2018).
H. Wu, C. Li, L. Song, H.-K. Tsang, J. E. Bowers, and D. Dai Meta-surface-enabled ultra-sharp multimode waveguide bends on silicon arXiv:1811.06914, October 14, 2018.
D. Hwang, A.J. Mughal, M.S. Wong, A.I. Alhassan,S. Nakamura, S,P. DenBaars Micro-light-emitting diodes with III-nitride tunnel junction contacts grown by metalorganic chemical vapor deposition Appl. Physics Express, Vol. 11, Issue 1, 012102, 2018.
N. Volet, X. Yi, Q.-F. Yang, E. J. Stanton, P. A. Morton, K. Y. Yang, K. J. Vahala and J. E. Bowers Micro-Resonator Soliton Generated Directly with a Diode Laser Laser & Photonic Reviews, (12)5, 1700307, April 17, 2018.
T. N. Do, H. Phan, T.-Q. Nguyen, and Y. Visell Miniature Soft Electromagnetic Actuators for Robotic Applications Advanced Functional Materials, 2018. Cover article.
R.Dodkins, S.Mahashabde, K.O’Brien, N.Thatte, N.Fruitwala, A.B.Walter, S.R.Meeker, P.Szypryt, B.A.Mazin MKID digital readout tuning with deep learning Astronomy and Computing

Volume 23, April 2018, Pages 60-71

S. Liu,  J. C. Norman,  D. Jung, MJ Kennedy, A. C. Gossard and J. E. Bowers Monolithic 9 GHz passively mode locked quantum dot lasers directly grown on on-axis (001) Si Applied Physics Letters, (113)4, 041108, July 27, 2018.
L.C. Chan, D.E. Morse, and M.J. Gordon Moth eye-inspired anti-reflective surfaces for improved IR optical systems & visible LEDs fabricated with colloidal lithography and etching Bioinspir. & Biomim. 13, 041001 (2018).
R. Jiang, X. Shen, J. Fang, P. Wang, E.X. Zhang, J. Chen, D.M. Fleetwood, R.D. Schrimpf, S.W.Kaun, E,C.H. Kyle, et al. Multiple Defects Cause Degradation After High Field Stress in AlGaN/GaN HEMTs IEEE Transactions on Device and Materials Reliability, vol. 18, pp. 364-376, Sept, 2018.
E.J. Stanton, A. Spott, J. Peters, M.L. Davenport, A. Malik, N. Volet, J. Liu, C.D. Merritt, W.W. Bewley, I. Vurgaftman, C.S. Kim, J.R. Meyer, J.E. Bowers Multi-spectral quantum cascade lasers on silicon with integrated multiplexers Submitted 2018.
A. S. P. Khope, M. Saeidi, R. Yu, X. Wu, A. Netherton, Y. Liu, Z. Zhang, Y. Zia, G. Fleeman, A. Spott, S. Pinna, C. Schow, R. Helkey, L. Theogarajan, R. C. Alferness, A. Saleh, and J. E. Bowers Multi-wavelength selective crossbar switch submitted to Optics Express, 2018.
R. Katsumata, R. Limary, Y. Zhang, B.C. Popere, A.T. Heitsch, M. Li, P. Trefonas, R.A. Segalman Mussel-inspired strategy for stabilizing ultrathin polymer films and its application to spin-on doping of semiconductors Chem. Mater., 30, 5285-5292 (2018). [DOI]
A. Ariyaratne, D. Bluvstein, B. A. Myers & A. C. Bleszynski Jayich Nanoscale electrical conductivity imaging using anitrogen-vacancy center in diamond Nature Communications volume 9, Article number: 2406 (2018)
R. Hermann and M.J. Gordon Nanoscale optical microscopy and spectroscopy using near-field probes Ann. Rev. Chem. Bio. Eng. 9, 1 (2018).
L. Galletti, T. Schumann, T. E. Mates, and S. Stemmer Nitrogen surface passivation of the Dirac semimetal Cd3As2 Phys. Rev. Mater. 2, 124202 (2018).
O.S. Koksaldi, J. Haller, H. Li, B. Romanczyk, M. Guidry, S. Wienecke, S. Keller, U.Mishra N-Polar GaN HEMTs Exhibiting Record Breakdown Voltage Over 2000 V and Low Dynamic On-Resistance EDL, July 2018
S-H. Han, A. Mauze, E. Ahmadi, T. Mates, Y. Oshima, and J. S. Speck n-type dopants in (001) β-Ga2O3 grown on (001) β-Ga2O3 substrates by plasma-assisted molecular beam epitaxy Semiconductor Science and Technology, vol. 33, no. 4: IOP Publishing, pp. 045001, 2018.
E. M. Spanton, A. A. Zibrov, H. Zhou, T. Taniguchi, K. Watanabe, M. P. Zaletel, A. F. Young Observation of fractional Chern insulators in a van der Waals heterostructure Science 360, 62–66 (2018).L. Galletti, T. Schumann, T. E. Mates, and S. Stemmer, Nitrogen surface passivation of the Dirac semimetal Cd3As2, Phys. Rev. Mater. 2, 124202 (2018).
T. Schumann, L. Galletti, D. A. Kealhofer, H. Kim, M. Goyal, and S. Stemmer Observation of the quantum Hall effect in confined films of the three-dimensional Dirac semimetal Cd3As2 Phys. Rev. Lett. 120, 016801 (2018).
H. J. Snijders,J. A. Frey,J. Norman,H. Flayac,V. Savona,A. C. Gossard,J. E. Bowers,M. P. van Exter,D. Bouwmeester,W. Löffler Observation of the Unconventional Photon Blockade PHYSICAL REVIEW LETTERS121,043601 (2018)
J. Kang, Y. Matsumoto, X. Li, J. Jiang, X. Xie, K. Kawamoto, M. Kenmoku, J. H. Chu, W. Liu, J. Mao, K. Ueno, K. Banerjee On-Chip Intercalated-Graphene Inductors for Next-Generation Radio Frequency Electronics Nature Electronics, Vol. 1, No. 1, pp. 46-51, 2018.
D. Valovcin, H.B. Banks, S. Mack, A. Gossard, K. West, L.  Pfeiffer, M.S. Sherwin Optical Frequency Combs from High-Order Sideband Generation Optics Express 26, 29807-29816 (2018) [www][arXiv]
N. Dagli Optical Modulators Handbook of Optoelectronics, 2nd Edition: Concepts, Devices and Techniques, vol. 1, Chapter 14, pp. 457-514, CRC Press, Taylor and Francis, 2018.
T. Mizumoto, R. Baets, and J. E. Bowers Optical nonreciprocal devices for silicon photonics using wafer-bonded magneto-optical garnet materials MRS Bulletin, (43)6, 419-424, June 11, 2018.
J. C. Norman, D. Jung, Y. Wan, and John E. Bowers Perspective: The Future of Quantum Dot Photonic Integrated Circuits Applied Physics Letters Photonics, (3)3, 030901, March 27, 2018.
M. J. Weaver, D. Newsom, F. Luna, W. Löffler, D. Bouwmeester Phonon interferometry for measuring quantum decoherence Phys. Rev. A 97, 063832 – Published 14 June 2018
T. Komljenovic, D. Huang, P. Pintus, M. A. Tran, M. L. Davenport, and J. E. Bowers Photonic Integrated Circuits Using Heterogeneous Integration on Silicon Proceedings of the IEEE, (106)12, 2246-2257, August 30, 2018.
A. Y. Liu and J. Bowers Photonic Integration with Epitaxial III-V on Silicon IEEE Journal of Selected Topics in Quantum Electronics, (24)6, 6000412, July 9, 2018.
M. Buffolo, F. Samparisi, C. De Santi, G. Meneghesso, E. Zanoni, D. Jung, J. Bowers, R. W. Herrick, and M. Meneghini Physical Origin of the Optical Degradation of InAs Quantum Dot Lasers submitted to Journal of Quantum Electronics (JQE) (2018).
W. Jin, R. G. Polcawich, P. Morton, and J. Bowers Piezoelectrically tuned silicon nitride ring resonator Optics Express, (26)3, 3174-3187, February 5, 2018.
A.E. Cetin,P. Iyidogan, Y. Hayashi, M. Wallen, K. Vijayan,†E. Tu, M. Nguyen, A. Oliphant Plasmonic Sensor Could Enable Label-Free DNA Sequencing ACS Sens. 2018, 3, 561−568.
H.J. Snijders, D.N.L. Kok, M.F. van de Stolpe, J. A. Frey, J. Norman A. C. Gossard, J. E. Bowers, M.P. van Exter, D. Bouwmeester, and W. Löffler Polarized quantum dot cavity-QED and single photons submitted Physical Review Applied (2018).
D. Ding, D. van Driel, L. M. C. Pereira, J. F. Bauters, M. J. R. Heck, G. Welker, M. J. A. de Dood, A. Vantomme, J. E. Bowers, W. Loer, and D. Bouwmeester Probing interacting two-level systems with rare-earth ions arXiv, arXiv:1811.05248, November 13, 2018.
L.Y. Kuritzky, C. Weisbuch, and J. S. Speck Prospects for 100% wall-plug efficient III-nitride LEDs Opt. Express, vol. 26, pp. 16600–16608, Jun, 2018.
?. Polshyn, H. Zhou, E. M. Spanton, T. Taniguchi, K. Watanabe, and A. F. Young Quantitative transport measurements of fractional quantum Hall energy gaps in edgeless graphene devices Physical Review Letters 121, 226801 (2018).
J.C. Norman, D. Jung, Z. Zhang, Y. Wan, S. Liu, C. Shang, R. Herrick, W.W. Chow, A.C. Gossard, J.E. Bowers Quantum Dot Lasers for Monolithic Photonic Integration JQE (2018).
D. Jung, J. Norman, Y. Wan, S. Liu, R. Herrick, J. Selvidge, K. Mukherjee, A. C. Gossard, and J. E. Bowers Recent Advances in InAs Quantum Dot Lasers Grown on on-axis (001) Silicon by Molecular Beam Epitaxy Physica Status Solidi A, (216)1, 1800602, January 9, 2019.
A.I. Alhassan, E.C. Young, A.Y. Alyamani, .Albadri, S.Nakamura, S.P. DenBaars, J.S. Speck Reduced-droop green III-nitride light-emitting diodes utilizing GaN tunnel junction Applied Physics Express, Vol. 11, Issue 4, 042101, 2018.
Z. Gu, S. Pandya, A. Samanta, S. Liu, G. Xiao, C. J. G. Meyers, A. R. Damodaran, H. Barak, A. Dasgupta, S. Saremi, A. Polemi, L. Wu, A.A. Podpirka, A. Will-Cole,C.J. Hawley, P.K.Davies, R.A. York, I. Grinberg, L.W. Martin, J.E. Spanier Resonant domain-wall-enhanced tunable microwave ferroelectrics 2018 Springer Nature Limited, https://doi.org/10.1038/s41586-018-0434-2.
Y. Kalcheim, N.A. Butakov, N. Vargas, M.H. Lee, J.D.V. Grande, J. Trastoy, P. Salev, J.A. Schuller, and I.K. Schuller
Robust Coupling between Structural and Electronic Transitions in a Mott Material Physical Review Letters 122, pp. 057601, 1-6 Journal
G. Yu, A. Jenkins, X. Ma, S. A. Razavi, C. He, G. Yin, Q. Shao, Q. L. He, H. Wu, W. Li, W. Jiang, X. Han, X. Li, A. C. Bleszynski Jayich, P. Khalili Amiri, and K. L. Wang Room-Temperature Skyrmions in an Antiferromagnet-Based Heterostructure Nano Lett., 2018, 18 (2), pp 980–986
J. Lozi, O. Guyon, N. Jovanovic, S. Goebel, P. Prashant N. Skaf, A. Sahoo, B. Norris, F. Martinache M. N'Diaye, B. Mazin, A.B. Walter, P. Tuthill, T. Kudo, H. Kawahara, T. Kotani, M. Ireland, N. Cvetojevic, E. Huby, S. Lacour, V. Sébastien; T.D. Groff, J.K. Chilcote, J. Kasdin, J. Knight, F. Snik, D. Doelman, Y Minowa, C. Clergeon, N. Takato, M. Tamura, T. Currie, H. Takami, M. Hayashi SCExAO, an instrument with a dual purpose: perform cutting-edge science and develop new technologies SPIE, Volume 10703, id. 1070359 12 pp. (2018).
J.S. Lee, S. Choi, M. Pendhakar, D.J. Pennachio, B. Markman, M.J.W. Rodwell, P. Krogstrup, and C.J. Palmstrom Selective-area chemical beam epitaxy of in-plane one-dimensional channels grown on InP(001) and InP(111)B surfaces Submitted(2018) – arXiv:1808.04563.
J. Duan, H. Huang, D. Jung,  Z. Zhang, J. Norman, J. E. Bowers, and F. Grillot Semiconductor quantum dot lasers epitaxially grown on silicon with low linewidth enhancement factor Applied Physics Letters, 112, 251111, June 21, 2018.
M. Khoury, H. Li, B.Bonef, L.Y. Kuritzky, A.J. Mughal,S.Nakamura, J.S. Speck, S.P. DenBaars Semipolar (20(2)over-bar1) GaN templates on sapphire: 432nm InGaN light-emitting diodes and light extraction simulations Applied Physics Express, Vol. 11, Issue 3, 036501, 2018.
C. Lee, C. Shen, C. Cozzan, R. M. Farrell, S. Nakamura, A. Y. Alyamani, B. S. Ooi, J. E. Bowers, S. P. DenBaars, and J. S. Speck Semipolar GaN-based laser diodes for Gbit/s white lighting communication: devices to systems Gallium Nitride Materials and Devices XIII, vol. 10532: International Society for Optics and Photonics, pp. 105321N, 2018.
S. Mehari, D.A. Cohen, D.L Becerra, S. Nakamura, S.P. DenBaars Semipolar InGaN blue laser diodes with a low optical loss and a high material gain obtained by suppression of carrier accumulation in the p-waveguide region Japanese Journal of Applied Physics 58, 2
C. Shen, T.K. Ng, C. Lee, S. Nakamura, J.S. Speck, S.P. Denbaars, A.Y. Alyamani, M.M. El-Desouki, B.S. Ooi Semipolar InGaN quantum-well laser diode with integrated amplifier for visible light communications Optics express, vol. 26, no. 6: Optical Society of America, pp. A219–A226, 2018.
D.J. Blumenthal, R. Heideman, D. Geuzebroek, A. Leinse and C. Roeloffzen Silicon nitride in silicon photonics Proceedings of the IEEE Special Issue on Silicon Photonics, Vol. 106 No. 12 DOI: 10.1109/JPROC.2018.2861576 (2018)
H.J. Snijders, J. A. Frey, J. Norman, H. Flayac, V. Savona, A. C. Gossard, J. E. Bowers, M. P. van Exter, D. Bouwmeester, W. Löffler Single photons and unconventional photon blockade in quantum dot cavity-QED arXiv.org > quant-ph > arXiv:1803.10992
A. Jenkins, M. Pelliccione, G. Yu, X. Ma, X. Li, K. L. Wang, A. C. Bleszynski Jayich Single spin sensing of domain wall structure and dynamics in a thin film skyrmion host arXiv:1812.01764, December 2018
M. Prezioso, M. Mahmoodi, F. Merrikh Bayat, H. Kim, H. Nili, A. Vincent, and D. Strukov Spike-timing-dependent plasticity learning of coincidence detection with passively integrated memristive circuits Nature Communications 9, art. 5311, 2018.
C. Zube, J. Malindretos, L. Watschke, R.R. Zamani, D. Disterheft, R.G. Ulbrich, A.Rizzi, M. Iza, S. Keller, S.P. DenBaars Spin injection in epitaxial MnGa(111)/GaN(0001) heterostructures Journal of Applied Physics Vol. 123, Issue 3, 2018
K. Ahadi, H. Kim, and S. Stemmer Spontaneous Hall effects in the electron system at the SmTiO3/EuTiO3 interface APL Mater. 6, 056102 (2018).
A. Boes, B. Corcoran, L. Chang, J. Bowers, and A. Mitchell Status and Potential of Lithium Niobate on Insulator (LNOI) for Photonic Integrated Circuits Laser & Photonics Reviews, (12)4, 1700256, February 23, 2018.
L. Megalini, S. T. Š. Brunelli, W. O. Charles, A. Taylor, B. Isaac, J. E. Bowers, and J. Klamkin Strain-Compensated InGaAsP Superlattices for Defect Reduction of InP Grown on Exact-Oriented (001) Patterned Si Substrates by Metal Organic Chemical Vapor Deposition Materials, 11, 337, February 28, 2018.
L. Chang, A. Boes, P. Pintus, J. Peters, M. Kennedy, X-W. Guo, N. Volet, S-P. Yu, S. Papp, J. Bowers Strong frequency conversion in heterogeneously integrated GaAs resonators submitted to Optica (2018).
S. Sonar, V. Fedoseev, M.J. Weaver, F.Luna,E. Vlieg, H. van der Meer,D. Bouwmeester, W. Löffler Strong thermomechanical squeezing in a far-detuned membrane-in-the-middle system PHYSICAL REVIEW A98, 013804 (2018)
S. Gundavarapu, G.M. Brodnik, M. Puckett, T. Huffman, D. Bose, R. Behunin, J. Wu, T. Qiu, C. Pinho, N. Chauhan, J. Nohava, P.T. Rakich, K.D. Nelson, M. Salit, D.J. Blumenthal Sub-hertz fundamental linewidth photonic integrated Brillouin laser Nat. Photon., 13(1): 60-67 (2019).
S. Lal, J. Lu, B.J. Thibeault, M.H. Wong, S.P. DenBaars, U.K. Mishra Suppression of Anomalously Large Threshold Voltage in Wafer-Bonded Vertical Transistors by Enhancing Critical Field to Impact Ionization IEEE Transactions on Electron Devices, 2018.
N.A. Butakov, I. Valmianski, T. Lewi, C. Urban, Z. Ren, A.A. Mikhailovsky, S.D. Wilson, I.K. Schuller, J.A. Schuller
Switchable Plasmonic-Dielectric Resonators with Metal-Insulator Transitions ACS Photonics 5, pp. 371 Journal
T. Lewi, N.A. Butakov, and J.A. Schuller
Thermal Tuning Capabilities of Semiconductor Metasurface Resonators Nanophotonics 8, pp.331-338 Journal
N. Liu, J. Peters, J.A. Floro, A. Ramu, J.E. Bowers, M. Zebarjadi Thermoelectric transport at F4TCNQ-silicon interface submitted to APL Materials (2018).
M. Goyal, L. Galletti, S. Salmani-Rezaie, T. Schumann, D. A. Kealhofer, and S. Stemmer Thickness dependence of the quantum Hall effect in films of the three-dimensional Dirac semimetal Cd3As2 APL Mater. 6, 026105 (2018).
H-H. Chen, J.S. Speck, C. Weisbuch, Y-R Wu Three dimensional simulation on the transport and quantum efficiency of UVC-LEDs with random alloy fluctuations Appl. Phys. Lett. 113, 153504, 2018.
D. Huang, P. Pintus and J. E. Bowers Towards heterogeneous integration of optical isolators and circulators with lasers on silicon Optical Materials Express, (8)9, 2471-2483, August 1, 2018.
M. Monavarian, A. Rashidi, A. A. Aragon, M. Nami, S. H. Oh, S. P. DenBaars, D. Feezell Trade-off between bandwidth and efficiency in semipolar (20(2)over-bar(1)over-bar) InGaN/GaN single- and multiple-quantum-well light-emitting diodes Applied Physics Letters, Vol. 112, Issue 19, 2018.
R. Kaminker, I.Kaminker, W.R. Gutekunst, Y. Luo, S. Lee, J. Niu, S. Han, C.J. Hawker Tuning conformation and properties of peptidomimetic backbones through dual N/Cα-substitution Chem. Commun. 2018 54, 5237-5240.
R. Kaminker, A. Anastasaki, W.R. Gutekunst, Y. Luo, S-H. Lee, C.J. Hawker Tuning of protease resistance in oligopeptides through N-alkylation Chem. Commun. 2018 54, 9631-9634.
L. Galletti, T. Schumann, O. F. Shoron, M. Goyal, D. A. Kealhofer, H. Kim, and S. Stemmer Two-Dimensional Dirac Fermions in Thin Films of Cd3As2 Phys. Rev. B 97, 115132 (2018).
Y. Liu et al. Ultra-Low-Loss Silicon Nitride Optical Beamforming Network for Wideband Wireless Applications IEEE J. Sel. Topics Quantum Electron., vol. 24, no. 4, pp. 1–10, 2018.
M. A. Tran, D. Huang, T. Komljenovic, J. Peters, A. Malik, and J. E. Bowers Ultra-Low-Loss Silicon Waveguides for Heterogeneously Integrated Silicon/III-V Photonics Applied Sciences, 8, 1139, July 12, 2018.
D. Dai, J. Bowers Ultra-sharp multimode waveguide bends with subwavelength gratings Laser & Photonics Reviews (2018).
H.A. Dobbs, Y. Kaufman, J. Scott, K. Kristiansen, A.M. Schrader, S.Y. Chen, P. Duda III, J.N. Israelachvili Ultra‐Smooth, Chemically Functional Silica Surfaces for Surface Interaction Measurements and Optical/Interferometry‐Based Techniques Advanced Engineering Materials 20 (2), 1700630
C. Conner, T. de Visser,  J. Loessberg , S. Sherman, A. Smith, S. Ma, M.T. Napoli, S. Pennathur Weld D. Energy Harvesting with a Liquid-Metal Microfluidic Influence Machine Physical Review Applied. 2018 Apr 5;9(4):044008.  
A. Myzaferi, A.J. Mughal, D.A. Cohen, R.M. Farrell, S.Nakamura, J.S. Speck, S.P. Denbaars Zinc oxide clad limited area epitaxy semipolar III-nitride laser diodes Optics Express, Vol. 26, Issue 10,  12490 , 2018.

Internal User - Conference Papers

Authors Title Conference
M.J.W. Rodwell, Y. Fang, J. Rode, J. Wu, B. Markman, S. T. S. Brunelli, J. Klamkin, M Urteaga 100-340GHz Systems: Transistors and Applications 2018 IEEE International Electron Devices Meeting (IEDM), 14.3. 1-14.3. 4
J.S. Lee, S. Choi, M. Pendharkar, A.P. McFadden, and C.J. Palmstrom 1D InAs channels byselective-area growth for topological superconductivity applications Am. Phys. Soc. March Meeting (Los Angeles CA  2018)
B. Song, S. Pinna, Y. Liu, L. Megalini, and J. Klamkin 3D hybrid integrated lasers for silicon photonics vol. 10537. International Society for Optics and Photonics 2018 p. 105370V.
B. Song, C. Stagarescu, W. Jin, P. Abolghasem, S. Ristic, N. Bickel, J. Bowker, A. Behfar, and J. Klamkin 3D Integrated Silicon Photonic External Cavity Laser Conference on Lasers and Electro-Optics, paper SM4G.5.
S. Liu, J.C. Norman, D.Jung, M. Kennedy, A.C. Gossard, J.E. Bowers 9 GHz passively mode locked quantum dot lasers directly grown on Si Device Research Conference (DRC) 2018
J. Norman, S. Liu, D. Jung, M. Kennedy, A. Gossard, J. Bowers 96 GHz Colliding Pulse Mode-locked Quantum Dot Lasers Grown on Silicon NAMBE (2018).
L. Chang, X. Guo, D.T. Spencer, J. Chiles, A. Kowligy, N. Nader, D. Hickstein, M. Kennedy, A. Boes, N. Volet, S.A. Diddams, S.B. Papp, J.E. Bowers A gallium arsenide nonlinear platform on silicon CLEO (2018)
S. Liu, T. Komljenovic, S. Srinivasan, E. Norberg, G. Fish, J.E Bowers A Heterogeneously Integrated III-V/Si Colliding Pulse Mode-locked Laser with On-chip Feedback The Optical Fiber Communication Conference and Exposition (OFC); San Diego, CA; March 11-14, 2018
M. Tran, T. Komljenovic, D. Huang, L. Liang, M. Kennedy,J.E. Bowers A Widely-Tunable High-SMSR Narrow-Linewidth Laser Heterogeneously Integrated on Silicon CLEO (2018)
Z. Zhang, D. Jung, J.C. Norman, P. Patel, W.W. Chow, J.E. Bowers Across Zero Continuously Tunable Linewidth Enhancement Factor in 1.3 µm InAs Quantum Dot Lasers on Silicon postdeadline paper at ISLC (2018).
P. Bhasker, S. Dogru and N. Dagli Active-Passive Integration using a-Si waveguides for Substrate Removed Electro-Optic Modulators 2018 IEEE Photonics Conference (IPC), DOI: 10.1109/IPCon.2018.8527092, Reston, VA, 30 September-4 October 2018.
J. Bowers Advanced laser designs for large-scale photonic integration 3rd WestLake Photonics Symposium (WPS), Zhejiang University, Hangzhou, China (2018).
D.B. Strukov Analog neurocomputing with emerging memory devices APS Society March Meeting, Los Angeles, CA, Mar. 2018
P. A. Morton, Jacob, J. E. Bowers Beyond Moore's Law’ Photonic Integrated Circuits for RF Photonics and Sensing Systems GOMAC (2018).
K. Scida, N. Arroyo-Currás, Y.Satik, A. Eden, J.C.T. Eijkel, S. Pennathur Bipolar electrode-induced electrokinetic effects in nanochannels generate fluorescence enhancement and sharp pH gradients in the absence of a voltage bias 256th ACS National Meeting & Exposition 2018: Nanoscience, Nanotechnology …
J. Jiang, J.H. Chu, K. Banerjee CMOS-Compatible Doped-Multilayer-Graphene Interconnects for Next-Generation VLSI IEEE International Electron Devices Meeting (IEDM), San Francisco, December 1-5, 2018, pp. 34.5.1-34.5.4. (One of the two IEDM 2018 papers selected in  Research Highlights of Nature Electronics, Nov 30, 2018) .
M. Weaver, J. Luna, V. Fedoseev, S. Sonar, F. Buters, D. Newsom, K. Heeck, W. LöFfler, D. Bouwmeester Coherent Coupling between Different Mechanical Modes APS March Meeting 2018, abstract id.B27.011
C.A. Forman, S. Lee, E.C. Young, J.A. Kearns, D.A. Cohen, J.T. Leonard, T.Margalith, S.P. DenBaars, S. Nakamura Continuous-wave operation of nonpolar GaN-based vertical-cavity surface-emitting lasers Gallium Nitride Materials and Devices XIII, 2018
L. Megalini, S.T. Suran Brunelli, W. Charles, A. Taylor, B. Isaac, J. Bowers and J. Klamkin Defect Filtering in InP-on-Si via Strain-Compensated InGaAsP Superlattices in MOCVD 2018 Compound Semiconductor Week (CSW), Cambridge, MA 2018
M. Buffolo, M. Pietrobona, C. De Santia, M. L. Davenport, J. E. Bowers, G. Meneghesso, E. Zanonia, M. Meneghinia Degradation mechanisms of heterogeneous III-V/Silicon loop-mirror laser diodes for photonic integrated circuits ESREF conference 2018.
M. Buffolo, M. Meneghini, C. D. Santi, M. L. Davenport, J. E. Bowers, G. Menegheso, and E. Zanoni Degradation Mechanisms of Heterogenous III-V 1.55 μm DBR Laser Diodes Photonics West 2018
C. D. Merritt, W. W. Bewley, C. L. Canedy, C. S. Kim, I. Vurgaftman, J. R. Meyer, A. Spott, J. Peters, M. L. Davenport, E. J. Stanton, C. Zhang, J, E. Bowers, J. Kirch, L. J. Mawst, and D. Botez Development of Quantum and Interband Cascade Lasers on Silicon submitted to Photonics West 2018, Smart Photonic and Optoelectronic Integrated Circuits Conference.
J. Meyer, A. Spott, E. Stanton, J.Bowers Development of Quantum and Interband Cascade Lasers on Silicon, Smart Photonic and Optoelectronic Integrated Circuits XX part of SPIE OPTO, http://spie.org/OE111 (2018).
B. SaifAddin, C.J. Zollner, A.Almogbel, H. Foronda, F. Wu, A. Albadri, A.A. Yamani, M. Iza, S. Nakamura, S.P. DenBaars, J.S. Speck Developments in AlGaN and UV-C LEDs grown on SiC Light-Emitting Diodes: Materials Devices and Applications for Solid State Lighting XXII 2018
Y. Wan, D. Inoue, D. Jung, J. Norman, C. Shang, A.C. Gossard, J. E. Bowers Directly modulated quantum dot micro-ring lasers at 1.3 µm on (001) GaP/Si with low-threshold current 2018 Progress In Electromagnetics Research Symposium (PIERS 2018) Toyama, Japan, on 1-4 August, 2018.
N.A. Butakov, M.W. Knight, T.Lewi, P.P. Iyer, H.T. Chorsi, J.D.V. Grande, Y. Kalcheim, P.W.C. Hon, I.K. Schuller, and J.A. Schuller

 

Electrically Switchable Infrared Nanophotonic Devices with VO2 2018 76th IEEE Device Research Conference (DRC) Conference Proceedings
L. Chan, R. Ley, P. Shapturenka, C.D. Pynn, S.P. DenBaars, M. Gordon Enhancing Light Extraction from Free-standing InGaN/GaN Light Emitters Using Bio-inspired Backside Surface Structuring AVS annual meeting
L.C. Chan, M.J. Gordon Fabrication Chemical Lift-Off and Optical Characterization of Nanoscale III-Nitride Light Emitters   AVS annual meeting
J-W Shi,  R-L Chao, J.C. Hulme, T. Komljenovic, J.E. Bowers Fully Integrated Photonic Microwave/Millimeter-Waves Frequency Tracking Synthesizer on Heterogeneous III-V/Si Platform CO-24 at Japan (8/21).
Z. Zhang, D. Jung, J. Norman, P. Patel, A.C. Gossard, J.E. Bowers Gain Characterization and Parameter Extraction of 1.3 μm InAs Quantum Dot Lasers on Silicon CLEO (2018)
Z. Ahang, D. Jung, J.C. Norman, P.Patel, W.W. Chow, J.E. Bowers Gain Characterization of p-doped 1.3 μm InAs Quantum Dot Lasers on Silicon: Theory and Experiment International Semiconductor Laser Conference (2018).
C.C. Evans, A. Spott, C.D. Merritt, W.W. Bewley, I.Vurgaftman, C.S. Kim, J.R. Meyer, J.M. Hensley, J.E. Bowers, M.B. Frish Gas Sensing Using Heterogeneously Integrated Quantum Cascade Lasers on Silicon CLEO (2018)
A.Malik, E.J. Stanton, J.Liu, A.Spott,J.E. Bowers Ge-on-Si wavelength division multiplexing components near 4.7 μm CLEO (2018)
J. Bowers Heterogeneous integration on silicon Tutorial at European Conference on Communications (ECOC), Rome, Italy, Sept.23-27, 2018.
J. Bowers High Efficiency Quantum Dot Photonic Integrated Circuits on Si CLEO 2018
L. Chang, A. Boes, P. Pintus, J.D. Peters, M. Kennedy, X. Guo, N. Volet, S. Yu, S.A. Diddams, S.B. Papp, J.E. Bowers High efficiency SHG in heterogenous integrated GaAs ring resonators postdeadline paper at IPC 2018
D. Jung, R. Herrick, J. Norman, Y. Wan, A.C. Gossard, J.E. Bowers High performance and reliable 1.3 μm InAs quantum dot lasers epitaxially grown on Si 2018 23rd Opto-Electronics and Communications Conference (OECC)
D. Jung, J. Norman, MJ Kennedy, C. Shang, R. Herrick, Y. Wan, B. Shin, I. MacFarlane, C. Jan, A. C. Gossard, J. E. Bowers High performance InAs quantum dot lasers grown on on-axis (001) Si with low threading dislocation density PCSI 2018.
J.C. Norman, Z. Zhang, D. Jung, Y. Wan, M. J. Kennedy, A. Torres, R.W. Herrick, A.C. Gossard, J.E. Bowers High performance quantum dot lasers epitaxially integrated on Si Proceedings Volume 10771, Quantum Communications and Quantum Imaging XVI; 107710D (2018) https://doi.org/10.1117/12.2319627

Event: SPIE Optical Engineering + Applications, 2018, San Diego, California, United States

D. Jung, R.Herrick, J.Norman, C. Jan, N. Caranto, A. Torres, Y. Wan, A.C. Gossard, J.E. Bowers Highly Improved Reliability of Low Threshold 1.3 μm III/V Quantum Dot Laser Epitaxially Grown on On-axis Si 2018 Conference on Lasers and Electro-Optics (CLEO)
P.A. Morton, M.J. Morton, C.Zhang, J.B. Khurgin, J.Peters, C.D. Morton, J.E. Bowers High-Power, High-SFDR, Heterogeneously Integrated III-V on Si MZI Modulators Research and Applications of Photonics in Defense Conference (RAPID) 2018
D.Inoue, D.Jung, Y. Wan, J.Norman, N. Nishiyama, S. Arai, A.C. Gossard,  J.E. Bowers High-speed direct modulation of 1.3 μm InAs quantum dot laser grown on on-axis (001) Si substrate 65th JSAP Spring Meeting (2018).
D.Inoue, D.Jung, Y. Wan, J.Norman, N. Nishiyama, S. Arai, A.C. Gossard,  J.E. Bowers High-speed direct modulation of 1.3 μm InAs quantum dot laser grown on on-axis (001) Si substrate 79th JSAP Autumn Meeting, September 2018.
J. C. Norman, D. Jung, P. Pintus, Y. Wan, Q. Li, P. Bhasker, Z. Zhang, C. Shang, M. Kennedy, N. Dagli, K. M. Lau, A. C. Gossard, J. E. Bowers InAs Quantum Dot Devices for Epitaxial Photonic Integrated Circuits on Silicon ICMBE (2018)
D. Jung, J. Norman, Y. Wan, S. Liu, R. Herrick, A. Gossard, J. Bowers InAs quantum dot lasers epitaxially grown on on-axis (001) silicon Group IV Photonics, Cancun, Mexico, Aug. 29 (2018).
D. Jung, J. Norman, Y. Wan, S. Liu, R. Herrick, A. Gossard, J. Bowers InAs Quantum dot Lasers Epitaxially Grown on On-Axis (001) Silicon 2018 IEEE 15th International Conference on Group IV Photonics (GFP).
B. Isaac, B. Song, S. Pinna, S. Arafin, L. Coldren and J. Klamkin Indium Phosphide Photonic Integrated Circuit Transmitter with Integrated Linewidth Narrowing for Laser Communications and Sensing 2018 IEEE International Semiconductor Laser Conference (ISLC), Santa Fe, NM, 2018, pp. 1-2.
M. Kassis, D. Chan, S. Kwok, T. Krasuski, J.E. Lyke, S. Ragland, S. Lilley, S. Cetre, P. Wizinowich, H.A. Lewis, P. Gomez, L. Rizzi, J.E. Larkin, T. Do, M.P. Fitzgerald, A. Skemer, J.X. Prochaska, K. Westfall, B. Mazin, D. Mawet, K. Matthews, C. Martin, A.W. Howard, J.R. Lu, M.R. Chun Innovations and advances in instrumentation at the W. M. Keck Observatory Proceedings Volume 10702, Ground-based and Airborne Instrumentation for Astronomy VII; 1070207 (2018) https://doi.org/10.1117/12.2312316

Event: SPIE Astronomical Telescopes + Instrumentation, 2018, Austin, Texas, United States

D. J. Blumenthal, S. Gundavarapu, D. Bose, G. Brodnik, T. Huffman, R. Behunin,  P. Rakich Integrated Low Linewidth Brillouin Lasers in Ultra Low Loss Si3N4 Waveguide Platform Conference on Lasers and Electro-Optics, OSA Technical Digest, paper FW3E.3 (2018).
P. Pintus, D. Huang, P. Morton, Y. Shoji, T. Mizumoto, J.E. Bowers Integrated optical isolator and circulator in silicon photonics European Conference on Communications (ECOC)  Rome, Italy  Sept.23-27, 2018
P. Bhasker, J. Norman, J. Bowers, and N. Dagli Intensity and Phase Modulators at 1.55 µm with InAs/InGaAs Quantum Dots Epitaxially Grown on Silicon Conference on Lasers and Electro-Optics - Pacific Rim, Hong Kong, China, July 29-August 3, 2018.
C. D. Merritt, A. Spott, E. J. Stanton, I. Vurgaftman, C. L. Canedy, A. Torres, M. Kim, M. L. Davenport, C. S. Kim, N. Volet, W. W. Bewley, A. Malik J. Liu, J. R. Meyer, and J. E. Bowers Interband and Quantum Cascade Lasers Integrated on Silicon, Mid-IR Optoelectronic Materials and Devices (MIOMD), Flagstaff, Arizona, October, 2018.
C. D. Merritt, W. W. Bewley, C. L. Canedy, C. S. Kim, I. Vurgaftman, and J. R. Meyer, M. Kim, A. Spott, E. J. Stanton, A. Torres, M. L. Davenport, and John E. Bowers Interband Cascade Lasers Integrated on Silicon SPIE Defense and Commercial Sensing conference in Orlando, April 19, 2018.
T. Squires Keynote lecture 16th International Conference on Surface Forces Kazan Russia August 20-25  2018
B. A. Mazin, G.D. Becker, G. Cancelo, K. France, W.C. Fraser, T. Jones, S.R. Meeker, K. O'Brien, J.X. Prochaska, S. Tendulkar, G. Vasisht KRAKENS: a superconducting MKID integral field spectrograph concept for the Keck I telescope Proceedings Volume 10702, Ground-based and Airborne Instrumentation for Astronomy VII; 107020H (2018) https://doi.org/10.1117/12.2312221

Event: SPIE Astronomical Telescopes + Instrumentation, 2018, Austin, Texas, United States

J. Bowers Large Scale Photonic Integrated Circuits Plenary Talk,ACP, Hangzhou, China, Oct. 26-29, 2018.
A. Jain, X. Wu, J. E. Bowers, R. Helkey, and J. Buckwalter Linear Ring Modulators with DC Kerr Phase Shifters 2018 IEEE Avionics and Vehicle Fiber-Optics and Photonics Conference (AVFOP), Portland, OR, USA, Nov 13-14, 2018.
X. Wu, W.Zhou, D.Huang, Z.Zhang, Y.Wang, J.Bowers, H.K. Tsang Low Crosstalk Bent Multimode Waveguide for On-chip Mode-Division Multiplexing Interconnects CLEO (2018)
J. Duan, H. Huang, D. Jung, J. Norman, J. E. Bowers, and F. Grillot Low linewidth enhancement factor and high optical feedback resistance of p-doped silicon based quantum dot lasers IPC (2018).
J. E. Bowers Low threshold, high gain 1300 nm quantum dot lasers epitaxially grown on Si PQE, 2018.
P. Bhasker, J. Norman, J. Bowers, and N. Dagli Low Voltage, High Optical Power Handling, Bulk GaAs/AlGaAs Electro-optic Modulators Integrated Photonics Research, Silicon, and Nano-Photonics Conference proceedings, paper IW3B.4, Zurich, Switzerland, 2-5 July 2018.
D.B. Strukov Mixed-signal nanoelectronic neurocomputing keynote talk at AI Design Forum at Applied Materials Inc., San Jose, CA, May 2018
D.B. Strukov Mixed-signal neurocomputing IEEE Custom Integrated Circuits Conference (CICC’18), San Diego, CA, Apr. 2018
D.B. Strukov Mixed-signal neuromorphic inference accelerators International Workshop on Future Computing (IWOFC'18), Shenzhen, China, Dec. 2018.
D.B. Strukov Mixed-signal neuromorphic inference accelerators ARL workshop on Nanotechnology-Enabled Beyond von Neumann Computing, Adelphi, Maryland, Nov. 2018
D.B. Strukov Mixed-signal vector-by-matrix multiplication with nonvolatile memories Non-Volatile Memory Technology Symposium (NVMTS'18), Sendai, Japan, Oct. 2018
Y. Zhang+, R. Katsumata+, S.P.O. Danielsen, B.C. Popere, A.T. Heitsch, M. Li, P. Trefonas, R.A. Segalman(+equally contributing authors) Molecular Design Strategies of Polymeric Spin-on Doping for Silicon Gordon Research Seminar and Conference, Polymer Physics, South Hadley, MA July 2018.
M.A. Tran, D. Huang, T.Komljenovic, S. Liu, L. Liang, M. Kennedy, J. E. Bowers Multi-ring Mirror-based Narrow-Linewidth Widely-Tunable Lasers in Heterogeneous Silicon Photonics European Conference on Communications (ECOC)  Rome  Italy Sept.23-27 2018
A.K. Rishinaramangalam, A. Rashidi, S.M.U. Masabih, A.A. Aragon, M. Monavarian, C. Lee, S.P. DenBaars, D. F. Feezell Nonpolar GaN-Based Superluminescent Diode with 2.5 GHz Modulation Bandwidth 2018 IEEE International Semiconductor Laster Conference
O.S. Koksaldi, J. Haller, H. Li, N. Hatui, B. Romanczyk, M. Guidry, S. Wienecke, S. Keller, U. Mishra N-Polar GaN HEMTs for High Voltage Switching Applications Demonstrating Negligible Dispersion at 450 V Quiescent Bias ISCS, May 2018, Boston, MA
D. Inoue, D. Jung, J.Norman, Y. Wan, N. Nishiyama, S. Arai, A.C. Gossard, J.E. Bowers NRZ and PAM-4 direct modulation of 1.3 μm quantum dot lasers grown directly on on-axis (001) Si European Conference and Exhibition on Optical Communication (ECOC) Rome  Italy (2018).
O. J. Ohanian, A. A. Yakusheva, S. T. Kreger, D. Kominsky, B. J. Soller, M. Tran, T. Komljenovic, and J. E. Bowers OFDR on Photonic Circuits: Fiber Optic Sensing Infrastructure and Applications 26th International Conference on Optical Fiber Sensors, OSA Technical Digest (Optical Society of America, 2018), paper WB1.
Y.Wan, D.Jung, D. Inoue, J.C. Norman, C. Shang, A.C. Gossard, J.E. Bowers On-chip detection from directly modulated quantum dot microring lasers on Si PIERS 2018
D.B. Strukov Opportunities and challenges for neurocomputing with nonvolatile memories International Memory Workshop (IMW’18), Kyoto, Japan, May 2018
S. Mehari, D.A. Cohen, D.L Becerrea, C. Weisbuch, S. Nakamura, S.P. DenBaars Optical Gain and Loss Measurements of Semipolar III-nitride Laser Diodes with ITO/thin-p-GaN Cladding Layers 2018 76TH DEVICE RESEARCH CONFERENCE (DRC)
J. Bowers Optical Integration: The Path to Terabit Transceivers IPC, Virginia, (2018).
T. Komljenovic, J. Bowers Path to Tbps Silicon Photonic Transceivers First North American Conference on Silicon Photonics for High Performance Computing, Colorado Springs, (2018).
P. J. M. Suni, J. Bowers, L. Coldren, S.J. Ben Yoo Photonic Integrated Circuits for Coherent Lidar 19th Coherent Laser Radar Conference (CLRC), Okinawa, Japan, June 18-21, 2018.
I.P. Marko, A. Baltusis, A.R. Adams, D. Jung, J.C. Norman, J.E. Bowers, S.J. Sweeney Physical properties of 1.3 µm InAs-based quantum dot laser on silicon ISLC (2018)
T. Squires Plenary Lecture European Fluid Mechanics Conference (Euromech), Vienna, Austria, September 9-13, 2018
J.A. Frey, H.J Snijders, J. Norman, A.C. Gossard, J.E. Bowers, W. Löffler, D. Bouwmeester Polarization tuning for high-fidelity fiber-coupled single photon sources PROCEEDINGS VOLUME 10733 SPIE NANOSCIENCE + ENGINEERING | 19-23 AUGUST 2018 Quantum Photonic Devices 2018
Y. Wan, D. Jung, J. Norman, K. Feng, A. Dagli, A.C. Gossard, J.E. Bowers Quadruple reduction of threshold current density for micro-ring quantum dot lasers epitaxially grown on (001) Si CLEO: Science and Innovations 2018 San Jose, California United States 13–18 May 2018 ISBN: 978-1-943580-42-2
E.J. Stanton, A. Spott, J.D. Peters, M.L. Davenport, N.Volet, A. Malik, J. Liu, C.D. Merritt, W.W. Bewley, I. Vurgaftman, C.S. Kim, J.R. Meyer, J.E. Bowers Quantum cascade multi-spectral laser with integrated beam combiner on silicon CLEO (2018)
J. Bowers Quantum dot lasers on Si CSW conference Boston May (2018)
C. Shang, Y. Wan, D. Jung, J. Norman, M.J. Kennedy, D. Liang, C. Zhang, A.C. Gossard, J.E. Bowers Quantum dot micro-lasers integrated with photodetectors and optical amplifiers on (001) Si via waveguide coupling 2018 Conference on Lasers and Electro-Optics (CLEO)
Y. Zhang, A. D’Ambra, R. Katsumata, R. Burns, M. Somervell, R. Segalman, C. Hawker, C. Bates Rapid and Selective Deposition of Patterned Thin Films via Spin Coating. Semiconductor Research Corporation (SRC) Global Research Collaboration (GRC) Technology Transfer e-Workshop. 04/24/2019
D. Seo, A.M. Schrader, S.Y. Chen, Y. Kaufman, T.R. Cristiani, S.H. Page, P.H. Koenig, Y. Gizaw, D.W. Lee, J.N.  Israelachvili Rates of cavity filling by liquids Proceedings of the National Academy of Sciences 115 (32), 8070-8075
D.B. Strukov Recent results and future prospects for mixed-signal nanoelectronic neurocomputing DARPA ERI Workshop, San Francisco, CA, July 2018
D. Jung, R. Herrick, J. Norman, J. Selvidge, M. Kennedy, C. Jan, K. Mukherjee, A.C. Gossard, J.E. Bowers Reliability study of InAs quantum dot lasers on Si MRS Annual Meeting (2018).
M.R. Mahmoodi, H. Nili, and D.B. Strukov RX-PUF: Low power, dense, reliable, and resilient physically unclonable functions based on analog passive RRAM crossbar arrays in: Proc. VLSI Symp’18, Honolulu, HI, June 2018, art. 176.
P. Shapturenka, S. Denbaars, and M.J. Gordom Scalable & Tunable High-Contrast Gratings for Integration into Resonant-Cavity micro-LEDs AVS annual meeting
Y. Zhang, R. Katsumata, M. Somervell, R. Burns, R. Segalman, C. Hawker, C. Bates Selective Spin Dewetting on Heterogeneous Surfaces Induced by Imperfect Self-Assembled Monolayers Semiconductor Research Corporation TECHCON, Austin, TX. 09/17/2018
Y. Zhang, R. Katsumata, M. Somervell, R. Burns, R. Segalman, C. Hawker, C. Bates Selective Spin Dewetting on Heterogeneous Surfaces Induced by Imperfect Self-Assembled Monolayers. Chemical Engineering Graduate Student Symposium, Santa Barbara, CA. 10/05/2018
Y. Zhang, A. D’Ambra, R. Katsumata, R. Segalman, C. Hawker, C. Bates Selective Spin-on Deposition Enabled by Imperfect Self-Assembled Monolayers. The International Society for Optics and Photonics (SPIE) Advanced Lithography Conference, San Jose, CA. 02/27/2019
Y. Zhang, A. D’Ambra, R. Katsumata, R. Burns, M. Somervell, C. Hawker, R. Segalman, C. Bates, Selective Spin-on Deposition of Polymers on Heterogeneous Surfaces American Physical Society (APS) March Meeting, Boston, MA. 03/04/2019
Y. Zhang, R. Katsumata, M. Somervell, R. Burns, C. Hawker, R. Segalman, C. Bates Selective Spin-on Deposition of Polymers on Heterogeneous Surfaces Materials Research Outreach Program, Santa Barbara, CA. 01/30/2019
J. Duan, K. Schires, D. Jung, J. E. Bowers, and F. Grillot Silicon quantum dot lasers with long delay optical feedback ISPALD (2018).
R. Ley, M. Wong, C. Pynn, S.P. DenBaars, M.J. Gordon Strain Relaxation in InGaN NanoLEDs   AVS annual meeting
L. Megalini, S. Tommaso, Š. Brunelli, W.O. Charles, A. Taylor, B. Isaac, J.E. Bowers, J. Klamkin Strain-compensated InGaAsP superlattices for defect reduction of InP grown on exact-oriented (001) patterned Si substrates by Metal Organic Chemical Vapor Deposition Compound Semiconductor Workshop (2018).
J.S. Lee, S. Choi, M. Pendharkar, A.P. McFadden, S. Koelling, M.A. Verheijen, E.P.A.M. Bakkers, and C.J. Palmstrom Structural and electronic characterization of in-plane InAs one-dimensional nanowires grown by selective-area epitaxy 60th Electronic Materials Conference (Santa Barbara, CA, 2018).
A. Goswami, D.J. Pennachio, B. Markman, H.Y. Tseng, S.T.S. Brunelli, S. Choi, A. Taylor, J. Klamkin, M. Rodwell, C.J. Palmstrom Structural characterization of epitaxial InP layers laterally overgrown inside dielectric templates 60thElectronic Materials Conference (Santa Barbara CA  2018).
S.T. Suran Brunelli, B. Markman, J. Wu, H.Y. Tseng, A. Goswami, M. Rodwell, C. Palmstrom, and J. Klamkin Template assisted selective epitaxy of InP via MOVPE towards horizontal heterojunctions for tunnel field effect transistors 19th International Conference on Metalorganic Vapor Phase Epitaxy (ICMOVPE-XIX), Nara, Japan, June 3-8, 2018.
N. Volet, X.Yi, Q-F. Yang, E.J. Stanton, P. Morton, K.Y. Yang, K.Vahala, J.Bowers Temporal soliton generated in a micro-resonator directly with a diode laser Integrated Photonics Research, Silicon, and Nano-Photonics (2018).
N. Volet, X.Yi, Q-F. Yang, E.J. Stanton, P.A. Morton, K.Y. Yang, K.J. Vahala, J.E. Bowers Temporal soliton locked in a micro-resonator pumped by a diode laser without an amplifier The Optical Fiber Communication Conference and Exposition (OFC); San Diego, CA; March 11-14, 2018
T. Squires Title not provided Student Contributed Talks:  Peter Chang 2018 American Institute of Chemical Engineers
T. Squires Title not provided Student Contributed Talks:   Xiaoyu Tang, 2018 American Institute of Chemical Engineers,2018 American Chemical Society Colloids
T. Squires Title not provided Student Contributed Talks:  Alexandra Bayles: 2018 American Institute of Chemical Engineers 2018 APS March Meeting
T. Squires Title not provided Student Contributed Talks:  Ian Williams, 2018 APS March Meeting
T. Squires Title not provided Student Contributed Talks: Anirudha Banerjee 2018 American Institute of Chemical Engineers, 2018 Gordon Research Seminar, Colloidal & Macromolecular Systems, 2018 APS March Meeting.
T. Squires Title not provided UCLA CNSI Workshop on Mathematical NanoSystems Jan 17 2018
Y. Zhao, H. Fu, G.T. Wang, S. Nakamura Toward ultimate efficiency: progress and prospects on planar and 3D nanostructured nonpolar and semipolar InGaN light-emitting diodes ADVANCES IN OPTICS AND PHOTONICS REVIEW
S.T. Suran Brunelli, B. Markman, J. Wu, H.Y. Tseng, A. Goswami, C. Palmstrom, M. Rodwell, J. Klamkin Towards Horizontal Heterojunctions for Tunnel Field Effect transistors with Template Assisted Selective Epitaxy via MOCVD 2018 Compound Semiconductor Week (CSW), Cambridge, MA 2018
B. Song, S. Pina, S. Ristic, and J. Klamkin Tunable 3D Integrated Hybrid Silicon Laser Asia Communications and Photonics Conference, paper Su3L.3.
W. Löffler,  et al. Unconventional photon blockade in polarized quantum dot cavity-QED for bright single photon sources Quantum Communications and Quantum Imaging XVI, part of SPIE Optical Engineering + Applications. a MOCVD 2018 Compound Semiconductor Week (CSW), Cambridge, MA 2018
R. Katsumata, R. Limary, B. Popere, Y. Zhang, M. Li, J. Kozhukh, A. Heitsch, P. Trefonas, R. A. Segalman Universal strategy for stabilizing ultrathin polymer films for spin-on doping applications APS March Meeting, Los Angels, CA, March 2018.
D. Huang, P. Pintus, J. Peters, P. Morton, Y. Shoji, T. Mizumoto, J.E. Bowers Widely tunable Ce:YIG on Si microring isolators for TE mode operation submitted to Group IV Photonics, Cancun, Mexico, Aug. 29-31 (2018).
C.Xiang, P.A. Morton, J.Khurgin, C. Morton, J.E. Bowers Widely tunable Si3N4 triple-ring and quad-ring resonator laser reflectors and filters Group IV Photonics, Cancun, Mexico, Aug. 29 (2018).

External Users - Journal Publications

Authors Title Publication
Z. Yang, D. Follman, A. R. Albrecht, P. Heu, N. Giannini, G. D. Cole, M. Sheik-Bahae 16 W DBR-free membrane semiconductor disk laser with dual-SiC-heatspreader Electronics Letters, vol. 54, no. 7, pp. 430-432, 5 April 2018
M.J. Yap, J. Cripe, G.L. Mansell, T.G. McRae, R.L. Ward, B.J.J. Slagmolen, D.A. Shaddock, P.Heu, D.Follman, G.D. Cole, D.E. McClelland, T. Corbitt Broadband reduction of quantum radiation pressure noise via squeezed light injection arXiv.org > quant-ph > arXiv:1812.09804
G. Kurczveil, A. Seyedi, D. Liang, M. Fiorentino, and R. G. Beausoleil Error-free operation in a hybrid-silicon quantum dot comb laser Photonics Technology Letters, vol. 30, pp. 71-74, 2018
P. V. Klimov, J. Kelly, J. Chen, M. Neeley, A. Megrant, B. Burkett, R. Barends, K. Arya, B. Chiaro, Y. Chen, A. Dunsworth, A. Fowler, B. Foxen, C. Gidney, M. Giustina, R. Graff, T. Huang, E. Jeffrey, Erik Lucero, J. Mutus, O. Naaman, C. Neill, C. Quintana, P. Roushan, Daniel Sank, A. Vainsencher, J. Wenner, T. White, S. Boixo, R. Babbush, V. Smelyanskiy, H. Neven, John M. Martinis Fluctuations of Energy-Relaxation Times in Superconducting Qubits PRL 121, 090502 (2018).. PRL | PDF | arXiv:1803.03226 | Google AI Blog
V. J. Kitsmiller, M. Dummer, K. Johnson, G. D. Cole, T. D. O’Sullivan Frequency domain diffuse optical spectroscopy with a near-infrared tunable vertical cavity Optics Express, vol. 26, no. 16, pp. 21033-21043, 6 August 2018
D. Liang, G. Kurczveil, X. Huang, C. Zhang, S. Srinivasan, Z. Huang, A. Seyedi, K. Norris, M. Fiorentino, J. E. Bowers, and R. G. Beausoleil Heterogeneous silicon light sources for datacom applications Optical Fiber Technology, vol. 44, pp. 43-52, 2018
J.Schwender, I.Tsioutsios, A.Tavernarakis, Q.Dong, Y. Jin, U. Staufer, A. Bachtold Improving the read-out of the resonance frequency of nanotube mechanical resonators Appl. Phys. Lett. 113, 063104 (2018)
J.A. Fincher, J.E. Dyer, A.R. Korte, S.Yadavilli, N.J. Morris, A. Vertes Matrix-free Mass Spectrometry Imaging of Mouse Brain Tissue Sections on Silicon Nanopost Arrays J. Comp. Neurol., 2018, 1-21. https://doi.org/10.1002/cne.24566
Y. Zhao, et al. Metal Organic Framework-Coated Optical VOC Gas Sensor 2018 IEEE Photonics Conference (IPC). IEEE, 2018.  
A. Belushkin, F. Yesilkoy, H. Altug Nanoparticle-Enhanced Plasmonic Biosensor for Digital Biomarker Detection in a Microarray ACS Nano 2018, 12, 5, pp. 4453-4461, https://doi.org/10.1021/acsnano.8b00519 2018
A. Boriskin, V. Drazic, R. Keating, M. Damghanian, O. Shramkova, L. Blonde Near field focusing by edge diffraction Vol. 43, No. 16 / 15 August 2018 / Optics Letters 4053
Jonathan Cripe, Nancy Aggarwal, Robert Lanza, Adam Libson, Robinjeet Singh, Paula Heu, David Follman, Garrett D. Cole, Nergis Mavalvala, Thomas Corbitt Observation of a room-temperature oscillator's motion dominated by quantum fluctuations over a broad audio-frequency band arXiv.org > quant-ph > arXiv:1802.10069v1
J. Cripe, B. Danz, B. Lane, M.-C. Lorio, J. Falcone, G. D. Cole, T. Corbitt Observation of an optical spring with a beamsplitter Optics Letters, vol. 43, no. 9, pp. 2193-2196, 1 May 2018
M. Marchiò, R. Flaminio, L. Pinard, D. Forest, C. Deutsch, P. Heu, D. Follman, G.D. Cole Optical performance of large-area crystalline coatings Optics Express Vol. 26, Issue 5, pp. 6114-6125 (2018)
F. Yesilkoy, R.A. Terborg, J. Pello, A.A. Belushkin, Y. Jahani, V. Pruneri, H. Altug Phase-sensitive plasmonic biosensor using a portable and large field-of-view interferometric microarray imager Light: Science & Applications volume 7, page 17152 (2018)
A.E. Cetin, P. Iyidogan, Y. Hayashi, M. Wallen, K. Vijayan, E. Tu, M. Nguyen, A. Oliphant Plasmonic Sensor Could Enable Label-Free DNA Sequencing ACS Sens. 2018, 3, 561−568; DOI: 10.1021/acssensors.7b00957 2018
V. Jayaraman, C. Burgner, A. Cazabat, S. Segal, K. Lascola, and F. Towner Propelling MEMS-VCSELs into the Mid-Infrared Compound Semiconductor, vol. 24, no. 7, 2018.
J. Cripe, T. Cullen, Y. Chen, P. Heu, D. Follman, G.D. Cole, T. Corbitt Quantum back action cancellation in the audio band arXiv.org > quant-ph > arXiv:1812.10028
J. Cripe, N. Aggarwal, R. Singh, R. Lanza, A. Libson, M.-J. Yap, G. D. Cole, D. E. McClelland, N. Mavalvala, T. Corbitt Radiation-pressure-mediated control of an optomechanical cavity Physical Review A, vol. 97, 013827, 18 January 2018
J. Pohl, G. D. Cole, U. Zeimer, M. Aspelmeyer, M. Weyers Reduction of absorption losses in MOVPE-grown AlGaAs Bragg mirrors Optics Letters, vol. 43, no. 15, pp. 3522-3525, 1 August 2018
N. Aggarwal, T. Cullen, J. Cripe, G.D. Cole, R. Lanza, A. Libson, D. Follman, P. Heu, T. Corbitt, N. Mavalvala Room temperature optomechanical squeezing arXiv.org > quant-ph > arXiv:1812.09942
V. Jayaraman, S. Segal, K. Lascola, C. Burgner, F. Towner, A. Cazabat, G.D. Cole, D. Follman, P. Heu, C. Deutsch Room-temperature continuous-wave mid-Infrared VCSEL operating at 3.35um Vertical-Cavity Surface-Emitting Lasers XXII, p. 105520B, Photonics West 2018, San Francisco, CA.
M. MacDougal, A. Hood, J. Thomas, G. Wicks, T. Golding, E.K. Huang Thermoelectrically-cooled extended-SWIR FPAs using unipolar barrier detector Proc. SPIE 10624, Infrared Technology and Applications XLIV, 1062402 (9 May 2018); https://doi.org/10.1117/12.2304388
S.A. Stopka, X.A. Holmes, A.R. Korte, L.R. Compton, S.T. Retterer, A.Vertes Trace Analysis and Reaction Monitoring by Nanophotonic Ionization Mass Spectrometry from Elevated Bowtie and Silicon Nanopost Arrays Adv. Funct. Mater., 2018, 28, 1801730. http://dx.doi.org/10.1002/adfm.201801730
S. L. de Bonis, C. Urgell, W. Yang, C. Samanta, A. Noury, J. Vergara-Cruz, Q. Dong, Y. Jin, A. Bachtold Ultrasensitive Displacement Noise Measurement of Carbon Nanotube Mechanical Resonators Nano Letters 18, 5324 (2018)
M. J. Senger, D. R. McCulley, N. Lotfizadeh, V. V. Deshpande, & E. D. Minot Universal interaction-driven gap in metallic carbon nanotubes Physical Review B 97, 035445 (2018)
Z. Li, O. Polat, E. Seker Voltage-gated closed-loop control of small-molecule release from alumina-coated nanoporous gold thin film electrodes Advanced Functional Materials 28:1801292 (2018).  

External Users - Conference Papers

Authors Title Conference Details
E.H. Miyasaki, G. Pettersson, K. Zaw, D. John, B. Thibeault, , B. Lynch, J. Hernandez, S. Abrahamsson 25 Plane Multifocus Microscopy Live 3D Imaging System for Neural Circuits BPS 19’ Annual Meeting, 2019
A. Roshan-Zamir, K. Yu, D. Liang, C. Zhang, C. Li, G. Fan, B. Wang, M. Fiorentino, R. Beausoleil, and S. Palermo A 14 Gb/s Directly Modulated Hybrid Microring Laser Transmitter in OFC San Diego, CA, USA, 2018, p. M1l.7.
B. Wang, Z. Huang, X. Zeng, R. Wu, W. V. Sorin, D. Liang, and R. G. Beausoleil A Compact Model for Si–Ge Avalanche Photodiodes in Group IV Photonics Kankun, Mexico, 2018.
D. Liang, C. Zhang, A. Roshan-Zamir, K. Yu, C. Li, G. Kurczveil, Y. Hu, W. Shen, M. Fiorentino, S. Kumar, S. Palermo, and R. Beausoleil A Fully-integrated Multi-λ Hybrid DML Transmitter in OFC San Diego, CA, USA, 2018, p. Th3B.5.
A. Seyedi, D. Liang, G. Kurczveil, Z. Huang, M. Fiorentino, and R. Beausoleil Comb and hybrid laser-driven WDM silicon photonic interconnects for exascale and HPC applications in SPIE Photonics West San Francisco, CA, USA, 2018, pp. Paper 10538-45.
A. Korte, A. Vertes Complementary Analysis and Quantitation of Metabolites by MALDI- and Silicon Nanopost Array-LDI-MS Proceedings of the 66th ASMS Conference on Mass Spectrometry and Allied Topics, San Diego, CA, June 3-7, 2018
J.E. Dyer, J.A. Fincher, N.J. Morris, M.J. Powell, D. Jones, V.K. Shanmugam, S. Yadavilli, J. Nazarian, R.K. Pirlo, A. Vertes Complementary Features of Laser Desorption Ionization from Silicon Nanopost Arrays and MALDI for Mass Spectrometry Imaging Proceedings of the 66th ASMS Conference on Mass Spectrometry and Allied Topics, San Diego, CA, June 3-7, 2018
Y. Hu, D. Liang, C. Zhang, G. Kurczveil, X. Huang, K. Mukherjee, and R. Beausoleil Electrically-pumped 1.31 um MQW lasers by direct epitaxy on wafer-bonded InP-on-SOI substrate in IEEE Photonics Conference Reston, VA, USA, 2018.
C. Zhang, D. Liang, G. Kurczveil, A. Descos, and R. G. Beausoleil Error-Free 12.5 Gb/s Direct Modulation of Low-Threshold Hybrid QD Microring Laser in ECOC Rome, Italy, 2018.
D. Liang, G. Kurczveil, C. Zhang, A. Descos, Y. Hu, M. Fiorentino, and R. Beausoleil Heterogeneous multi-wavelength quantum-dot light sources on silicon in European Semiconductor Laser Workshop Bari, Italy, 2018.
C. Zhang, D. Liang, G. Kurczveil, and R. G. Beausoleil High Speed QDs Microring Lasers on Silicon in ECIO Valencia, Spain, 2018.
D. McCulley, E. Minot Highly efficient carbon nanotube photodiodes enabled by field-enhanced exciton dissociation (March 2018) Materials Research Society Spring Meeting, Phoenix, AZ
Z. Yanga, D. Follman, A.R. Albrecht, P. Heu, G.D. Cole, M. Sheik-Bahae High-Power DBR-Free Membrane Semiconductor Disk Lasers CLEO 2018 © OSA 2
B. Tossoun, G. Kurczveil, C. Zhang, D. Liang, and R. G. Beausoleil High-speed 1310 nm Hybrid Silicon Quantum Dot Photodiodes with Ultra-low Dark Current in Device Research Conference Santa Barbara, CA, USA, 2018, p. Late Late News paper.
D. Liang Integrated Photonic Interconnect Reliability for Datacom Applications in Electronic Design Process Symposium Milpitas, CA, USA, 2018.
G.D. Cole, D. Follman, P. Heu, G-W. Truong, C. Deutsch, C. Franz, A. Alexandrovski, B. Ma, X. Cheng Laser-induced damage measurements of crystalline coatings (Conference Presentation) Proceedings Volume 10805, Laser-Induced Damage in Optical Materials 2018: 50th Anniversary Conference; 108050E (2018) https://doi.org/10.1117/12.2326769

Event: SPIE Laser Damage, 2018, Boulder, Colorado, United States

A. Bachtold Mechanical resonators based on nanotubes and graphene 2nd Quantum User Meeting 2018 in London, November 2018 (ICFO)
A. Bachtold Mechanical resonators based on nanotubes and graphene GDRI Graphene and Co in Sète, October 2018 (ICFO)
A. Bachtold Mechanical resonators based on nanotubes and graphene MRS, Phoenix, April 2018 (ICFO)
A. Bachtold Mechanical resonators based on nanotubes and graphene Spin mechanics & nanoMRI meeting, Les Houches, February 2018 (ICFO)
A. Bachtold Mechanical resonators based on nanotubes and graphene TNT2015 in Lecce, September 2018(ICFO)
A. Bachtold Mechanical resonators based on nanotubes and graphene workshop on Workshop on the interaction of light with quantum and topological materials, Barcelona, June 2018 (ICFO)
E. Seker Nanoporous Gold: From an Ancient Material to Biomedical Devices IEEE Micro and Nanotechnology in Medicine, Kauai, HI, December 2018.
G. Kurczveil, C. Zhang, A. Descos, D. Liang, M. Fiorentino, and R. Beausoleil On-chip Hybrid Silicon Quantum Dot Comb Laser With 14 Error-Free Channels in ISLC 2018 Santa Fe, NM, USA, 2018.
C. Shang, Y. Wan, D. Jung, J. Norman, M. Kennedy, D. Liang, C. Zhang, A. C. Gossard, and J. E. Bowers Quantum dot micro-lasers integrated with photodetectors and optical amplifiers on (001) Si via waveguide coupling in CLEO San Jose, CA, USA, 2018.
A. Bushmaker Rad Hard Thin-Film Flexible Electronics for Spaceflight Applications Microelectronics Reliability and Qualification Workshop (MRQW), El Segundo, CA (Feb 2018)
A. Vertes, A. Arul, P. Avar, A. Korte, C. Lombard-Banek, P. Nemes, L. Parvin, Z. Sahab, B. Shrestha, S.A.  Stopka, W. Yuan, D. Bunin, M. Knapp, A. Poggio, C. Talcott, B. Davis, C. Morton, C. Sevinsky, M. Zavodszky Systems Biology Approach for Mechanism of Action Identification in 30 Days, Proceedings of the 66th ASMS Conference on Mass Spectrometry and Allied Topics, San Diego, CA, June 3-7, 2018
M. Senger, E. Minot The relationship between carbon nanotube structure, dielectric environment and physical properties revealed by spectrally-resolved photocurrent microscopy Materials Research Society Spring Meeting, Phoenix, AZ, (March 2018).
W. Shen, D. Liang, C. Zhang, and R. G. Beausoleil Thermal Management of Hybrid Silicon Microring Laser in InterPACK San Francisco, CA, USA, 2018.