Nanofab Staff Internal Pages

From UCSB Nanofab Wiki
Revision as of 23:13, 24 July 2023 by Mehalana v (talk | contribs) (Procedure Added Nanofiles,LMI,synology)
Jump to navigation Jump to search

Pages intended for NanoFab Staff, internal.

Equipment Group

Process Group

NanoFab IT

Computers, Networks, FTP/File-Sync etc.

  • Jobs List for NanoFab-IT tasks (OnDema)
  • Instructions+Procedures can be found in gDrive > Facilities Group > Computer Systems
  • Unifi Network SDN
    1. Add/Replace new Switch visit store.ui.com/us/en we are using follow switch below
      1. switching-standard 48/24/16 ports
      2. switching-aggregation 8 Ports
      3. Flex Mini 5 Ports
    2. Add/ Replace Fail SFP Receiver When searching in the Maintenance Shop, locate the bin labeled SFP Receiver & look for 1000 BASE-LX 1310-nm SFP Receiver
    3. Add/ Replace Fail Fiber Cable When searching in the Maintenance Shop, locate the bin labeled Fiber LC to SC and search for the Optical Fiber Patch Cable.
    4. Add/Replace the Ethernet patch We have four length of the patch cable 3/5/10/15 ft located in the Tel/Data RM#1117 In both case please update the IT Hardware Log Sheet: Eth Ports, Endpoints
      1. Patch Pannel to Switch Label format : <<sw-name>>-<<port-number>>
      2. System to Wall Port Lable format : Nanofile-Network 10.1.1.1/16
  • Synology
    1. Active Backup for Business
      1. Add new device
      2. Add new server
      3. Restore a device
    2. Create a new Network Share Folder
    3. Add a Device to Apple Time Machine
  • Nanofiles
    1. Add Device to Network
    2. Nanofile Sync
      1. Add a new Device
      2. Replace a Device
    3. Generating New WireGard VPN Credentials
      1. Server-Side
        1. Commend for generating the keys cd /etc/wireguard wg genkey | tee privatekey_<<replace it with username>> | wg pubkey > publickey_<<replace it with username>>
        2. Add a new line in /etc/hostname.wg0 PublicKey = <<public_key_of_new_user>> AllowedIPs = 10.1.10.XXX/32
        3. Service Restart sh /etc/netstart wg0
      2. Client-Side
        1. Generate the a new file with .conf extension [Interface] Address = 10.1.10.XXX/32 DNS = 10.1.1.1 PrivateKey = <<privatekey_of_new_user>>
          [Peer] PublicKey = hHngYmJZUxRfLAmCxhC00m80hjsNDKl4LKV4iDYN+TY= Endpoint = nanofiles1.ece.ucsb.edu:5900 AllowedIPs = 10.1.0.0/16 PersistentKeepalive = 25
  • Utilities Software
    1. LogMeIn
      1. Add a new Device
      2. Add a new user
      3. Remove a External/Internal User

Useful UCSB Pages

  • Facilities Work Requests - Here's where you report facilities repair requests, like replacing light bulbs, building problems (doors, elevators) etc.

Old / Defunct