Research Pubs 2026-04-24

From UCSB Nanofab Wiki
Revision as of 16:32, 24 April 2026 by John d (talk | contribs) (pasted from AI)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search
UCSB Nanofabrication Facility — Research Groups & Publications
A curated directory of research groups utilizing the UCSB Nanofab, organized by discipline. Each section highlights recent high-impact publications and representative research imagery.
Last updated: April 2026


Photonics and Integrated Optics

Silicon photonics, III-V integration, optical communications, nanophotonic devices, and metasurfaces — enabling next-generation data links, sensing, and on-chip light manipulation.


Optical Communications & Photonic Integration Group — Prof. Daniel Blumenthal

PI: Prof. Daniel Blumenthal (Google Scholar) • Group Website

Develops ultra-low-loss silicon nitride (Si3N4) photonic integrated circuits for stimulated Brillouin lasers, optical gyroscopes, optical frequency synthesis, and emerging atom-photonic quantum integration on chip.

Selected Recent Publications:

  • Integrated optical frequency division for microwave and mmWave generationNature 627, 540–545 (2024). DOI
  • Integrated photonic molecule Brillouin laser with a high-power sub-100-mHz fundamental linewidthOptics Letters 49(1), 45–48 (2024). DOI
Ultra-low-loss silicon nitride photonic coil resonator chip used for Brillouin lasers and high-Q resonators.
PZT-integrated silicon nitride microcomb resonator for chip-based optical frequency division.


Silicon Photonics, AIM Photonics & Institute for Energy Efficiency — Prof. John Bowers

PI: Prof. John Bowers (Google Scholar) • Silicon PhotonicsAIM PhotonicsIEE

Leads research on heterogeneous integration of III-V materials on silicon for lasers, amplifiers, and modulators, as well as advanced silicon photonic platforms for datacom, telecom, and ultra-narrow-linewidth laser sources.

Selected Recent Publications:

  • Roadmapping the next generation of silicon photonicsNature Communications 15, 751 (2024). DOI
  • Lithium niobate photonics: Unlocking the electromagnetic spectrumScience 379(6627) (2023). DOI
3D photonic integrated circuit: heterogeneous III-V on silicon architecture without an isolator (Nature, 2023).
Novel conjoined racetrack resonator geometry for silicon photonics.


Integrated Photonics Laboratory — Prof. Jonathan Klamkin

PI: Prof. Jonathan Klamkin (Google Scholar) • Group Website

Specializes in III-V photonic integrated circuits for free-space optical communications, LiDAR, microwave photonics, and monolithic integration of III-V quantum dot lasers on silicon via selective area heteroepitaxy.

Selected Recent Publications:

  • Selective area heteroepitaxy of low dislocation density antiphase boundary free GaAs microridges on flat-bottom (001) Si for integrated silicon photonicsJournal of Applied Physics 129, 123103 (2021). DOI
  • Towards fully monolithic silicon-based integrated photonics: MOCVD grown lasers on silicon by blanket and selective area heteroepitaxyProc. SPIE (Photonics West, 2022). DOI
3D hybrid integrated silicon photonics platform merging InP and GaAs devices with SiPh.
Laser communication terminal for free-space optical links (NASA-funded research).


Schow Lab — Prof. Clint Schow

PI: Prof. Clint Schow (Google Scholar) • Group Website

Develops energy-efficient optical interconnects for data centers, with emphasis on analog coherent detection architectures that eliminate power-hungry DSP, leveraging silicon photonics and co-packaged optics.

Selected Recent Publications:

  • A Monolithic O-Band Coherent Optical Receiver for Energy-Efficient Intra-Data Center LinksJournal of Lightwave Technology 42(7) (2024). DOI
  • Analog Coherent Detection for Energy Efficient Intra-Data Center Links at 200 Gbps Per WavelengthJournal of Lightwave Technology 39(2) (2021). DOI
Low-power coherent optical links for datacenter interconnects.
Cryogenic silicon photonic optical links for classical and quantum computing.


Schuller Lab — Prof. Jon Schuller

PI: Prof. Jon Schuller (Google Scholar) • Group Website

Investigates light-matter interactions at the nanoscale, designing dielectric and semiconductor metasurfaces for directional light emission, magneto-optical traps, and active reconfigurable photonic devices.

Selected Recent Publications:

  • High efficiency large-angle polarization-insensitive retroreflecting metasurface for magneto-optical trapsApplied Physics Letters 124, 251704 (2024). DOI
  • Optimizing Polarization Selective Unidirectional Photoluminescence from Phased-Array MetasurfacesAdvanced Optical Materials (2024). DOI
Hybrid organic/inorganic crystalline microstructures with quantum-confinement-induced red luminescence.
Tunable dielectric metasurface beam deflector for engineered light steering.


Quantum Computing, Quantum Sensing & Quantum Materials

Quantum optics, entangled photon sources, NV-center sensing, topological qubits, and correlated electron systems — building the hardware foundations for quantum information science.


Quantum Optics & Quantum Information Group — Prof. Dirk Bouwmeester

PI: Prof. Dirk Bouwmeester (Google Scholar) • Group Website

Explores quantum optics and cavity quantum electrodynamics with semiconductor quantum dots, optomechanical systems using phononic crystal membranes, and quantum decoherence phenomena.

Selected Recent Publications:

  • Single-emitter quantum key distribution over 175 km of fibre with optimised finite key ratesNature Communications 14, 3573 (2023). DOI
  • Phononically shielded photonic-crystal mirror membranes for cavity quantum optomechanicsQuantum Science and Technology 10(4), 045004 (2025). DOI
File:Bouwmeester micropillar quantum dot.png
Micropillar samples with embedded quantum dots for cavity-QED experiments and single-photon sources.
File:Bouwmeester phononic crystal membrane.png
Phononically shielded photonic-crystal membrane for cavity quantum optomechanics.


Quantum Photonics Laboratory — Prof. Galan Moody

PI: Prof. Galan Moody (Google Scholar) • Group Website

Develops integrated quantum photonic devices on chip-scale platforms, including entangled photon-pair sources from microring resonators, 2D material quantum emitters, and scalable single-photon technologies for quantum networking.

Selected Recent Publications:

  • 2022 Roadmap on integrated quantum photonicsJournal of Physics: Photonics 4, 012501 (2022). DOI
  • Defect and strain engineering of monolayer WSe2 enables site-controlled single-photon emission up to 150 KNature Communications 12, 3585 (2021). DOI
File:Moody AlGaAsOI entanglement chip.jpg
AlGaAs-on-insulator chip with microring array devices for high-rate entangled photon-pair generation.
File:Moody NanoLetters cover 2D emitters SiN.jpg
Nano Letters cover: 2D material quantum emitters (hBN) integrated with silicon nitride microring resonators.


Quantum Sensing & Imaging Group — Prof. Ania Jayich

PI: Prof. Ania Bleszynski Jayich (Google Scholar) • Group Website (10−9 Lab)

Engineers nitrogen-vacancy (NV) centers in diamond for ultra-sensitive nanoscale magnetometry and quantum sensing. Recent breakthroughs leverage many-body quantum dynamics for signal amplification in solid-state quantum sensors.

Selected Recent Publications:

  • Signal amplification in a solid-state sensor through asymmetric many-body echoNature 646, 68–73 (2025). DOI
  • Scalable nanoscale positioning of highly coherent color centers in prefabricated diamond nanostructuresNature Communications 16 (2025). DOI
File:Jayich NV diamond probe.jpg
Diamond scanning probe tip with embedded NV center for nanoscale magnetometry of condensed matter systems.
File:Jayich diamond NV AoS Hughes.jpg
Diamond NV center engineering for quantum sensing applications.


Palmstrom Group — Prof. Chris Palmstrom

PI: Prof. Chris Palmstrom (Google Scholar) • Group Website

Grows quantum materials by molecular beam epitaxy (MBE), including III-V semiconductor heterostructures, Heusler compounds, and superconductor/semiconductor hybrids for topological quantum computing and superconducting circuits.

Selected Recent Publications:

  • Cryogenic Growth of Tantalum Thin Films for Low-Loss Superconducting CircuitsPhysical Review Applied 23(3), 034025 (2025). DOI
  • Fabrication and Characterization of Low-Loss Al/Si/Al Parallel Plate Capacitors for Superconducting Quantum Information Applicationsnpj Quantum Information 11 (2025). DOI
File:Palmstrom hashtag nanowire Majorana SEM.jpg
SEM of InSb "hashtag" nanowire networks grown by MBE, partially coated with superconducting aluminum for Majorana quasiparticle experiments.
File:Palmstrom MBE lab UCSB.jpg
The Palmstrom MBE lab at UCSB for growing novel quantum materials. Photo: Lilli McKinney.


Young Lab — Prof. Andrea Young

PI: Prof. Andrea Young (Google Scholar) • Group Website

Investigates correlated electronic phases in van der Waals heterostructures, including superconductivity, magnetism, and quantum Hall physics in graphene-based systems using nanofabrication and low-temperature transport measurements.

Selected Recent Publications:

  • Superconductivity in rhombohedral trilayer grapheneNature 598, 434–438 (2021). DOI
  • Isospin magnetism and spin-polarized superconductivity in Bernal bilayer grapheneScience 375(6582) (2022). DOI
File:Young nanoSQUID microscope.jpg
NanoSQUID-on-tip cryogenic microscope for nanoscale magnetic and thermal imaging of quantum materials.
File:Young graphene Corbino device.jpg
Corbino-geometry monolayer graphene device for quantum Hall measurements and correlated electron state studies.


High-Speed Electronics & RF

Sub-THz transistors, 2D-material nanoelectronics, and advanced CMOS architectures — driving the next generation of wireless communications and computing.


High Speed Electronics Group — Prof. Mark Rodwell

PI: Prof. Mark Rodwell (Google Scholar) • Group Website

Develops InP heterojunction bipolar transistor (HBT) integrated circuits and transceiver modules operating at 100–300 GHz for next-generation sub-THz wireless communication systems with multi-Gbps data rates.

Selected Recent Publications:

  • 100–300 GHz Wireless: Transistors, ICs, and SystemsIEEE Microwave Magazine (2025). DOI
  • A 280 GHz InP HBT Direct-Conversion Receiver with 10.8 dB NFIEEE RFIC Symposium (2023). DOI
File:Rodwell InP HBT CrossSection SEM.png
Cross-sectional SEM of a UCSB InP HBT showing sub-micron emitter, base, and collector mesa layers.
File:Rodwell THz Transceiver IC.png
130 nm InP HBT transceiver IC layout for 100–300 GHz wireless systems.


Nanoelectronics Research Lab — Prof. Kaustav Banerjee

PI: Prof. Kaustav Banerjee (Google Scholar) • Group Website

Pioneers 2D material-based transistor architectures for future CMOS scaling, including 3D transistors with 2D semiconductors, neuromorphic computing platforms using tunnel-FETs, and cryogenic CMOS for quantum computing.

Selected Recent Publications:

  • Three-dimensional Transistors with Two-dimensional Semiconductors for Future CMOS ScalingNature Electronics (2024). DOI
  • An Ultra Energy-efficient Hardware Platform for Neuromorphic Computing Enabled by 2D-TMD Tunnel-FETsNature Communications (2024). DOI
File:Banerjee Graphene Kinetic Inductor.png
Intercalated multilayer graphene on-chip spiral inductors — the first kinetic inductors achieving 1.5× higher inductance density than copper.
3D nano-plate FET architecture using 2D WS2 semiconductors in gate-all-around configuration.


Wide-Bandgap Semiconductors & Power Electronics

GaN and Ga2O3 devices for solid-state lighting, micro-LEDs, laser diodes, and high-voltage power conversion — from Nobel Prize-winning blue LEDs to next-generation ultra-wide-bandgap power electronics.


Krishnamoorthy Research Group — Prof. Sriram Krishnamoorthy

PI: Prof. Sriram Krishnamoorthy (Google Scholar) • Group Website

Advances ultra-wide-bandgap semiconductor device technology, particularly β-Ga2O3 power electronics including kilovolt-class MOSFETs and Schottky barrier diodes grown by MOCVD for high-voltage, high-efficiency power conversion.

Selected Recent Publications:

  • Kilovolt-Class β-Ga2O3 MOSFETs on 1-inch Bulk SubstratesApplied Physics Letters (2024). DOI
  • 2.1 kV (001)-β-Ga2O3 Vertical Schottky Barrier Diode with High-k Oxide Field PlateApplied Physics Letters (2023). DOI
File:Krishnamoorthy Ga2O3 TriGate MESFET.png
Tri-gate β-Ga2O3 MESFET with SiNx passivation, achieving record 0.95 GW/cm2 power figure of merit.
File:Krishnamoorthy Ga2O3 SiC MOSFET.png
β-Ga2O3-on-SiC MOSFET for enhanced thermal management of UWBG power devices.


Solid State Lighting & Electronic Center (SSLEEC) — Prof. Steven DenBaars & Prof. Shuji Nakamura

Directors: Prof. Steven DenBaars (Google Scholar) • Prof. Shuji Nakamura (Nobel Laureate, 2014 — Google Scholar) • SSLEEC Website

Leads development of III-nitride (InGaN/GaN) optoelectronic devices including micro-LEDs scaled to the single-micron regime for AR/VR displays, edge-emitting laser diodes, and advanced LED architectures with metasurface and distributed Bragg reflector integration.

Selected Recent Publications:

  • High External Quantum Efficiency in Ultra-small Amber InGaN MicroLEDs Scaled to 1 μmApplied Physics Letters (2024). DOI
  • Metasurface Light-Emitting Diodes with Directional and Focused EmissionNano Letters (2023). DOI
Angled SEM of a 10×10 μm InGaN/GaN micro-LED with distributed Bragg reflectors achieving 130% higher light output.
File:SSLEEC GaN LED DeviceStack.png
GaN-based LED/laser diode epitaxial device stack for blue-violet emission.


Advanced Materials & Novel Devices

Topological semimetals, memristive crossbar arrays, plasma nanoscience, and neuromorphic hardware — pushing the boundaries of materials science and unconventional computing architectures.


Stemmer Research Group — Prof. Susanne Stemmer

PI: Prof. Susanne Stemmer (Google Scholar) • Group Website

Investigates quantum materials including functional and correlated complex oxides and topological semimetals, with emphasis on thin-film epitaxial growth (MBE), quantum transport, and electronic structure engineering at heterostructure interfaces.

Selected Recent Publications:

  • Two-Dimensional Topological Insulator State in Cadmium Arsenide Thin FilmsPhysical Review Letters 130, 046201 (2023). DOI
  • Similarity in the Critical Thicknesses for Superconductivity and Ferroelectricity in Strained SrTiO3 FilmsApplied Physics Letters (2022). DOI
File:Stemmer Cd3As2 HAADF STEM.png
High-resolution HAADF-STEM of a Cd3As2 topological semimetal thin film grown by MBE, revealing ordered cadmium vacancies at atomic resolution.
File:Stemmer SrTiO3 QSTEM Vacancy.png
Quantitative STEM image revealing individual strontium vacancy sites in SrTiO3 with picometer-scale displacement mapping.


Strukov Research Group — Prof. Dmitri Strukov

PI: Prof. Dmitri Strukov (Google Scholar) • Group Website

Develops novel memristive (resistive switching) devices and hybrid CMOS/memristor circuits for neuromorphic computing, in-memory computing, and hardware accelerators for neural networks and optimization problems.

Selected Recent Publications:

  • Recent Advances and Future Prospects for Memristive Materials, Devices, and SystemsACS Nano (2023). DOI
  • 4K-Memristor Analog-Grade Passive Crossbar CircuitNature Communications 12 (2021). DOI
SEM of a 64×64 passive memristive crossbar array (4,096 devices) with Ti/Al/TiN electrodes and Al2O3/TiO2-x switching layers.
4K-pixel grayscale Einstein image programmed into the memristive crossbar with <4% tuning error, demonstrating analog-grade conductance control.


Gordon Lab — Prof. Mike Gordon

PI: Prof. Michael J. Gordon (Google Scholar) • Group Website

Works on plasma science and engineering (atmospheric and non-thermal plasmas), catalysis in molten metals for methane pyrolysis and hydrogen production, and nanoscale fabrication including colloidal lithography and micro-LED characterization.

Selected Recent Publications:

  • AC Plasmas Directly Excited in Liquid-Phase Hydrocarbons for H2 and Unsaturated C2 Hydrocarbon ProductionJournal of the American Chemical Society (2025). DOI
  • Dry Reforming of Methane Catalysed by Molten Metal AlloysNature Catalysis 3, 83–89 (2020). DOI
Laser shadowgraph of a nanosecond-pulsed plasma discharge in liquid hexane showing streamer propagation and shock waves.
File:Gordon AC Plasma Hexane Timelapse.png
Time-resolved high-speed images of AC arc discharges in liquid hexane at 17.3 kHz for hydrogen production.


Microfluidics & MEMS

Nanofluidic transport, lab-on-chip biosensors, and microfabricated biomedical devices — bridging nanofabrication with biological and chemical applications.


Pennathur Lab — Prof. Sumita Pennathur

PI: Prof. Sumita Pennathur (Google Scholar) • Group Website

Studies electrokinetic transport in nanofluidic channels, ionic current rectification in bipolar nanochannels, and the design of nanofluidic diodes and biosensors, combining experimental micro/nanofabrication with computational modeling.

Selected Recent Publications:

  • Coupling Charge-Regulated Interfacial Chemistry to Electrokinetic Ion Transport in Bipolar SiO2–Al2O3 Nanofluidic DiodesAdvanced Materials Interfaces (2024). DOI
  • Nanofluidic Diodes Based on Asymmetric Bio-Inspired Surface Coatings in Straight Glass NanochannelsFaraday Discussions (2023). DOI
Cross-section schematic and SEM of a fused silica nanofluidic channel with embedded electrodes for electric double layer modulation.
SEM of silicon microneedle array for minimally invasive biofluid extraction, fabricated using MEMS techniques.


Astronomical Instrumentation

Superconducting photon-counting detectors for ground-based astronomy — fabricating the cameras that image exoplanets.


Mazin Laboratory — Prof. Ben Mazin

PI: Prof. Benjamin MazinINSPIRE-HEP PublicationsLab Publication List

Pioneers Microwave Kinetic Inductance Detectors (MKIDs) — superconducting photon-counting sensors with zero read noise that measure each photon's energy, arrival time, and position. Deploys MKID-based cameras (MEC, XKID) at major telescopes for direct imaging of exoplanets.

Selected Recent Publications:

  • Characterization of Photon Arrival Timing Jitter in Microwave Kinetic Inductance Detector ArraysApplied Physics Letters (2024). DOI
  • Characterizing the Dark Count Rate of a Large-Format MKID ArrayOptics Express (2023). DOI
The MEC 20,440-pixel MKID array mounted in its gold-plated copper package — deployed at the Subaru 8m Telescope for high-contrast exoplanet imaging.
File:Mazin MKID 10K Array Zoom.jpg
10,000-pixel MKID array in gold sample box with progressive zoom-ins showing pixel grid and individual lumped-element resonator structures.



Publication Archives

Research Presentations

Research Image Galleries