Maskless Aligner (Raith PicoMaster XF)
| ||||||||||||||||||||||||||||||||||
| |
| |
|
| |
| |
|
Work In Progress This article is still under construction. It may contain factual errors. Content is subject to change. |
About
The Raith PicoMaster XF 200 allows for arbitrary direct-write patterning of I-Line photoresists from an uploaded CAD drawing/file (GDS, DXF, CIF etc.). The system uses a Grating Light Valve ("GLV") for patterning the exposure light-field, to programmatically expose digitized patterns directly onto the sample - no glass photomasks/reticles are required.
Depending on the exposure options and write area, the PicoMaster is able to expose a 100mm wafer in about 60min, and achieves minimum features sizes around 0.5µm, with overlay/alignment accuracy better than 200nm.
Detailed Specifications
- Maximum Writeable Area: TBD
- Substrate size: 200mm round down to 1cm pieces
- Wafer / substrate thickness: Max. / Min. TBD
- Exposure optics:
- Digital micromirror device (DMD)
- Laser: 405nm
- Lens NA = TBD
- Alignment Accuracy: Global ≤ 500nm; Local ("Field") ≤ 250nm
- Linewidth variation: ≤100nm (relevant to stitched exposure fields)
- Minimum Features: ~0.40µm line/space demonstrated with 0.5µm-thick PR. Requires additional effort. ≥1µm is relatively straightforward.
- Write Grid (Address Unit): TBD
- Additional manufacturer options:
- Backside alignment
Operating Procedures
Standard Operating Procedures
- PicoMaster XF 200- Standard Operating Procedure - updated Sept 26th 2026
- Includes File-upload procedure, CAD Conversion, Exposure and Alignment.
- User manuals are available at the tool and on the tool's computer.
Training Procedure
To get authorized on this tool:
| Request Training |
|---|
Design Info - CAD layout
- Design Guidelines + Tips - Important info for designing your CAD files, alignment marks etc.
- CAD Files and Templates - example CAD designs and useful CAD structures.
Recipes
- Recipes > Lithography > Direct-Write_Lithography_Recipes#Maskless_Aligner_(Raith_PicoMasterXF)
- Starting recipes for various I-Line photoresists
Calibrate your own Litho process
- Use Exposure Matrix mode exposure for doing an FEM ("Focus-Exposure Matrix").
- Lithography Calibration - Analyzing a Focus-Exposure Matrix - how to analyze an FEM for repeatable processes
Litho. recipes for all our photolith. tools can be found on the Photolithography Recipes page.

