CHEMICAL DESCRIPTION VENDOR Other Names/Notes
Acetone, 4L, 4 bt = 1 cs ACETONE ACS SAFE-COTE 4L Percent Purity ≥99.5% FISHER SCIENTIFIC ACE
Propanol, 4L, 4 bt = 1 cs 2-PROPANOL OPTIM AGRADE Percent Purity ≥99.9% FISHER SCIENTIFIC ISO, IPA, Isopropanol
Ethanol DEHYDRATED ALCOHOL, 200 PROOF, UNDENATURED, USP GRADE- 4LGLASS SPECTRUM CHEMICALS & LAB
Methanol, 4L, 4 bt = 1 cs METHANOL OPTIMA GRADE 4L Percent Purity ≥99.9% FISHER SCIENTIFIC
Toluene, 4 L TOLUENE OPTIMA GRADE 4L Percent Purity ≥99.8% FISHER SCIENTIFIC
Ethylene Glycol ETHYLENE GLYCOL LABORATORY GRADE FISHER SCIENTIFIC
Amyl Acetate, 4L bottle AMYL ACETATE LABORATORY GRADE 4L FISHER SCIENTIFIC
MIBK, 4L bottle Methyl iso-Butyl Ketone (Certified ACS), Grade Certified ACS Reagent FISHER SCIENTIFIC
Chloroform, 2.5 L Chloroform, 99+%, Acros Organics FISHER SCIENTIFIC
Xylenes, 1 liter XYLENES ACS 4L Percent Purity ≥98.5% FISHER SCIENTIFIC
T1100 BCB rinse solvent RINSE T1100 4 LITER GLASS BOTTLE MICROCHEM CORP.
Nitric, 500ml. NITRIC ACID IND SAFECOTE 2,5L, Assay Percent Range 70% FISHER SCIENTIFIC
Sulfuric, 2.5 L SULFURIC AC 21/2L IND SAFECOTE Assay Percent Range 95.0 to 98.0 w/w % FISHER SCIENTIFIC H2SO4
O-Phosphoric, 2.5 L O-PHOSPHORIC ACID Percent Purity ≥85.0% (w/w) FISHER SCIENTIFIC H3PO4
Citric acid, liquid, 1.0 M, 1L CITRIC ACID, 1.00 Molar FISHER SCIENTIFIC C6H8O7, solution
50/50 w/w Citric Acid Monohydrate in Water PREMIX CITRIC ACID CAW 1:1 TRANSENE COMPANY, INC. C6H8O7, solution
Citric acid, granular, monohydrate, 3 kg CITRIC ACID GRAN CERT ACS 3KG Percent Purity 99.0 to 102.0% FISHER SCIENTIFIC C6H8O7, powder
Acetic, 2.5L ACETIC ACID GLACIAL ACS 2.5L IND SAF-CT Assay Percent Range: ≥99.7% w/w FISHER SCIENTIFIC
Hydrochloric, 2.5L HYDROCHLORIC ACID Percent Purity 36.5 to 38.0% (w/w) FISHER SCIENTIFIC HCl
Hydrofluoric, 49%, 500 Ml HYDROFLUORIC ACID RGT 500ML Assay (HF) 48 - 51% VWR INTERNATIONAL HF
Hydrofluoric, Buffered HF, 1 gal BUFFER-HF TRANSENE COMPANY, INC. BHF, "Buffered oxide etch"

4-8% HF

Hydrobromic, 500 mL HYDROBROMIC ACID 48% CERT ACS 500ML Percent Purity 47.0 to 49.0% FISHER SCIENTIFIC HBr
Chrome mask etchant, 1 qt CHROMIUM ETCHANT 1020 TRANSENE COMPANY, INC.
Aluminum etchant, A, 1 qt ALUMINUM ETCHANT TYPE A TRANSENE COMPANY, INC.
Aluminum etchant, D, 1 qt ALUMINUM ETCHANT TYPE D TRANSENE COMPANY, INC.
Gold etchant, TFA, 1 qt GOLD ETCHANT TFA TRANSENE COMPANY, INC.
Nickel etchant, TFB, 1 qt. NICKEL ETCH TFB TRANSENE COMPANY, INC.
Titanium etchant, TFTN TITANIUM ETCHANT TFTN TRANSENE COMPANY, INC.
Nanostrip KMG-Nanostrip INTEGRATED MICRO MATERIALS
Oxalic Acid OXALIC ACID CERTIF ACS 500G Percent Purity 99.5 to 102.5% FISHER SCIENTIFIC
Formic Acid FORMIC ACID 2.5LT 98% (ACS) FISHER SCIENTIFIC
Chromic Acid (Chromium Trioxide) Chromium Trioxide (Crystalline/Certified ACS) Percent Purity ≥98.0% FISHER SCIENTIFIC CrO3
Ammonium hydroxide, 2.5 L AMMONIUM HYDROXIDE ACS Assay Percent Range: 28.0 to 30.0 w/w % FISHER SCIENTIFIC NH4OH
Ammonium sulfide, 500 mL AMMONIUM SULFIDE SOLUTION Assay Percent Range 20 to 24% (aqueous) FISHER SCIENTIFIC (NH4)2S
Sodium hydroxide, 1L SODIUM HYDROX SOL 50% CERT 1L Percent Purity Inclusive between 50% FISHER SCIENTIFIC NaOH
Potassium hydroxide, 43. POT HYDROX SOL 45% CERT 4L Concentration or Composition (by Analyte or Components) 45% FISHER SCIENTIFIC KOH
Hydrogen peroxide, 500 mL HYDROGEN PEROXIDE 30% Percent Purity 30.0 to 32.0% FISHER SCIENTIFIC H2O2
Hydrogen peroxide, 1 gal HYDROGEN PEROXIDE 30% Percent Purity 30.0 to 32.0% FISHER SCIENTIFIC H2O2
TMAH, 25%, per liter TETRAMETHYLAMMONIUM HYDROXIDE, 25% TRANSENE COMPANY, INC.
Saturated Bromine Water (SBW), 1L BROMINE WATER RGT 500ML Percent Purity ≥99.5% FISHER SCIENTIFIC Br2 : H2O
AZ400k developer, concentrated, 1 gal AZ 400K CONCENTRATE PHOTORESIST DEVELOPER INTEGRATED MICRO MATERIALS
AZ400k developer, 1:4 diluted, 1 gal AZ 400k 1:4 PHOTORESIST DEVELOPER INTEGRATED MICRO MATERIALS Pre-diluted
AZ 726 MIF developer, 1 gal AZ 726 MIF DEVELOPER INTEGRATED MICRO MATERIALS
AZ NMP Rinse & Photoresist Stripper AZ® NMP Rinse & Photoresist Stripper INTEGRATED MICRO MATERIALS
AZ 300 T, stripper, 1 gal. AZ 300T STRIPPER INTEGRATED MICRO MATERIALS
MicroChem 101A Developer, 1 gal 101A DEVELOPER MICROCHEM CORP. SAL 101A, XP 101A
AZ 300 MIF Developer AZ 300 MIF DEVELOPER INTEGRATED MICRO MATERIALS
SU-8 Developer SU-8 DEVELOPER - 4 X 4L MICROCHEM CORP.
DS2100 BCB Developer DEVELOPER DS2100 MICROCHEM CORP. BCB Developer
EC 11 EC SOLVENT 11 - 4 GL CS MICROCHEM CORP.
AZ EBR AZ EBR EDGE BEAD REMOVER INTEGRATED MICRO MATERIALS
KwikStrip, gallon size AZ KWIK STRIP PHOTORESIST STRIPPER INTEGRATED MICRO MATERIALS
Remover PG, SU-8 stripper REMOVER PG - 4 X 4L MICROCHEM CORP.
SPR 955 CM-0.9, 1 Gal. SPR 955CM-0.9 - 1 GL MICROCHEM CORP. Photoresist, PR
SPR 955 CM-1.8, 1 Gal. SPR 955CM-1.8 - 1 GL MICROCHEM CORP. Photoresist, PR
SPR 220-3.0, 1 gal. SPR 220-3.0 P.R. 1GL MICROCHEM CORP. Photoresist, PR
SPR 220-7.0, 1 GAL, SPR 220-7.0 P.R. 1GL MICROCHEM CORP. Photoresist, PR
CEM-365 IS, for stepper, 1 pint. CEM365IS-QT SHIN-ETSU MICROSI, INC. Photoresist, PR contrast enhancer
AZ P4110 1Qt. AZ P4110 PHOTORESIST INTEGRATED MICRO MATERIALS Photoresist, PR
AZ P4210  1Qt. AZ P4210 G-LINE/BROADBAND PHOTORESIST INTEGRATED MICRO MATERIALS Photoresist, PR
AZ P4330 RS  1QT. AZ P4330-RS INTEGRATED MICRO MATERIALS Photoresist, PR
AZ 5214-EIR  1QT. AZ 5214-E IR PHOTORESIST INTEGRATED MICRO MATERIALS Photoresist, PR
AZ P4620 1QT AZP4620-1Q INTEGRATED MICRO MATERIALS Photoresist, PR
AZ P9260 1gal. AZ® 9260 i-line / Broadband Photoresist INTEGRATED MICRO MATERIALS Photoresist, PR
AZnLOF 2020, 1 gal. AZ nLoF 2020 NEGATIVE TONE LIFT-OFF PHOTORESIST INTEGRATED MICRO MATERIALS Photoresist, PR
AZnLOF 2035, 1 qt. AZ Nlof 2035 NEGATIVE TONE LIFT-OFF PHOTORESIST INTEGRATED MICRO MATERIALS Photoresist, PR
AZnLOF 2070, 1 qt AZ NLOF2070 NEGATIVE TONE LIFT-OFF PHOTORESIST INTEGRATED MICRO MATERIALS Photoresist, PR
NR9-1000PY Negative Resist NR9-1000PY Futurrex, Inc. Photoresist, PR
NR9-3000PY Negative Resist NR9-3000PY Futurrex, Inc. Photoresist, PR
NR9-6000PY Negative Resist NR9-6000PY Futurrex, Inc. Photoresist, PR
LOL 2000, 1 qt. LOL 2000 -1 QT MICROCHEM CORP. Photoresist, PR Underlayer
AZ nLOF P5510 photoresist, 1 gallon AZ nLoF 5510 NEGATIVE TONE LIFT-OFF PHOTORESIST. INTEGRATED MICRO MATERIALS Photoresist, PR
THMR-IP3600 HP D THMR-IP3600 HP TOK AMERICA, INC. Photoresist, PR
XHRIC-11 1 LITER XHRIC-11 1 LITER BREWER SCIENCE, INC. Photoresist, PR, BARC
PMGI, SF 3, 500 ml PMGI SF 3 - 500ml Glass MICROCHEM CORP. Photoresist, PR
PMGI, SF 5, 500 ml PMGI SF 5 - 500ml Glass MICROCHEM CORP. Photoresist, PR
PMGI, SF 8, 500 ml PMGI SF-8, glass 500ml MICROCHEM CORP. Photoresist, PR
PMGI, SF11, 500 ml PMGI SF 11 - 500ML GLASS MICROCHEM CORP. Photoresist, PR
PMGI, SF15, 500 ml PMGI SF 15 - 500ML GLASS MICROCHEM CORP. Photoresist, PR
Dow Advanced Electronic, 4024-40, photo BCB CYCLOTENE* 4024 - 40 / 0.95 LITERS (BCB) MICROCHEM CORP. Photo-BCB
Cyclotene 3022-46 CYCLOTENE* 3022-46 MICROCHEM CORP. BCB
AP3000 BCB Adhesion Promoter, gall. ADHESION PROMOTER AP3000 MICROCHEM CORP. BCB Adhesion Promoter
Omnicoat, adhesion promoter for SU-8 OMNICOAT - 500ML GLASS MICROCHEM CORP. Resist
HMDS, (Fineline adhes.), 1 bt. MPHP-PT MICROPRIMER HIGH PURITY SHIN-ETSU MICROSI, INC. Photoresist Adhesion Promoter
Tergitol Spectrum Chemical Manufacturing Corporation TERGITOL NP-10 SURFCTNT 500ML   T1273500ML FISHER SCIENTIFIC Detergent
SU-8 2005 Photoresist SU-8 2005 - 500ml GLASS MICROCHEM CORP. Photoresist, PR
SU-8 2010 Photoresist SU-8 2010 - 500ml GLASS MICROCHEM CORP. Photoresist, PR
SU-8 2015 Photoresist SU-8 2015 - 500ml GLASS MICROCHEM CORP. Photoresist, PR
SU-8 2075 Photoresist SU-8 2075 - 500ml Glass Resist MICROCHEM CORP. Photoresist, PR
UV-6 0.8 Photoresist UV6-0.8 MICROCHEM CORP. Photoresist, PR
DUV42P-6 DUV42P-6 BREWER SCIENCE, INC Photoresist, PR, BARC
UVN 30-0.8L (UVN 2300-0.5) UVN 30-0.8L-1 GL NOWPAK MICROCHEM CORP. Photoresist, PR
Brewer Science DS-K101-304, 1 gal bt. ARC DS-K101-304, 1 LITER BREWER SCIENCE, INC. Photoresist, PR, BARC
UV 210GS-0.3, 1 gal. bt. UV 210GS-0.3 - 1 GL NOWPAK MICROCHEM CORP. Photoresist, PR
mr-UV Cur 21 100 nm, 100ml. MRT-mr-UV Cur 21, 100nm - 100ml Glass MICROCHEM CORP. Nanoimprint Resist
Santovac 5P Santovac 5P Ultra Polyphenyl Ether Pump Fluid KURT J LESKER Oil
SF1 Polishing Fluid SF1 Polishing Fluid LOGITECH LIMITED CMP Slurry
CrystalBond Wax Crystalbond 509 (Clear Color) Mounting Adhesive, Stick (round shape) Mounting wax, ~135°C melting point, acetone soluble.