Lift-Off Techniques
Description/Tutorial
Bi-Layer Process with PMGI Underlayer and Contact Aligner
Chemical Datasheets
Positive Photoresists
AZP4000 (AZ4110, AZ4210, AZ4330)
OCG825
SPR220 (SPR220-3, SPR220-7)
SPR950-0.8
SPR955CM (SPR955CM-0.9, SPR955CM-1.8)
UV6-0.7
UV210-0.3
Negative Photoresists
AZ5214
AZnLOF5510
AZnLOF2000 (AZnLOF2020, AZnLOF2035, AZnLOF2070)
UVN2300-0.5
Underlayers
PMGI (PMGI SF-11, PMGI SF-13, PMGI SF-15)
Shipley LOL2000
E-beam resists
PMMA (PMMA, P(MMA-MAA) copolymer)
maN 2403
Nanoimprinting
NX1020
MRI-7020
Contrast Enhancement Materials
CEM365iS
Anti-Reflection Coatings
XHRiC
AR2
DS-K101 (developable BARC)
Developers
AZ400K (AZ400K, AZ400K1:4)
AZ300MIF
Photoresist Removers
1165
AZ300T
PRX-127
Recipes
R
= Recipe is available. Clicking this link will take you to the recipe.
A
= Material is available for use, but no recipes are provided.
Lithography Recipes
Contact Aligners
Steppers
Flood Expose
E-Beam Lithography
Positive Resists
SUSS MJB-3
SUSS MA-6
Stepper 1
(GCA 6300)
Stepper 2
(AutoStep 200)
Stepper 3
(ASML DUV)
MLA150
(Heidelberg)
AZ4110
R1
R1
A
A
AZ4210
R1
R1
A
A
AZ4330RS
R1
R1
A
A
OCG 825-35CS
A
A
A
A
SPR 950-0.8
A
A
A
A
SPR 955 CM-0.9
A
A
R1
R1
SPR 955 CM-1.8
A
A
R1
R1
SPR 220-3.0
R1
R1
R1
R1
SPR 220-7.0
R1
R1
R1
R1
THMR-IP3600 HP D
A
A
UV6-0.7
A
UV210-0.7
A
Negative Resists
SUSS MJB-3
SUSS MA-6
Stepper 1
(GCA 6300)
Stepper 2
(AutoStep 200)
Stepper 3
(ASML DUV)
MLA150
(Heidelberg)
AZ5214-EIR
R1
R1
R1
R1
AZnLOF 2020
R1
R1
R1
R1
AZnLOF 2035
A
A
A
A
AZnLOF 2070
A
A
A
A
AZnLOF 5510
A
A
R1
R1
UVN30-0.5
A
SU-8 2015
A
A
A
A
Underlayers
SUSS MJB-3
SUSS MA-6
Stepper 1
(GCA 6300)
Stepper 2
(AutoStep 200)
Stepper 3
(ASML DUV)
MLA150
(Heidelberg)
PMGI SF-11
PMGI SF-15
LOL 2000
XHRIC-11 (BARC)
AR-2 (BARC)
DS-K 101-307 (BARC)
Overlayers
SUSS MJB-3
SUSS MA-6
Stepper 1
(GCA 6300)
Stepper 2
(AutoStep 200)
Stepper 3
(ASML DUV)
MLA150
(Heidelberg)
CEM-365 IS
E-Beam Resists
SUSS MJB-3
SUSS MA-6
Stepper 1
(GCA 6300)
Stepper 2
(AutoStep 200)
Stepper 3
(ASML DUV)
MLA150
(Heidelberg)
??????
???????
Nanoimprint Resists
SUSS MJB-3
SUSS MA-6
Stepper 1
(GCA 6300)
Stepper 2
(AutoStep 200)
Stepper 3
(ASML DUV)
MLA150
(Heidelberg)
MR-I 7020
Nanonex NX-1020
SUSS MJB-3
SUSS MA-6
Stepper 1
(GCA 6300)
Stepper 2
(AutoStep 200)
Stepper 3
(ASML DUV)
MLA150
(Heidelberg)
Navigation menu
Personal tools
Create account
Log in
Namespaces
Page
Discussion
English
Views
Read
View source
View history
More
Search
InvisibleMenu
QuickLinks
Lab Rules
Common Questions/FAQ
Staff List
Equipment Signup
Chemicals + MSDS
Protofab
Equipment
Full Tool List
Lithography
Vacuum Deposition
Dry Etch
Wet Processing
Thermal Processing
Packaging
Metrology & Test
Recipes and Data
Lithography
Vacuum Deposition
Dry Etching
Wet Etching
Thermal Processing
Packaging Tools