Difference between revisions of "Microscopes"
Jump to navigation
Jump to search
(→Documentation: link to microscope training) |
(added LEXT) |
||
Line 7: | Line 7: | ||
|manufacturer = Nikon (3) & Olympus (1) |
|manufacturer = Nikon (3) & Olympus (1) |
||
}} |
}} |
||
− | =Nikon= |
+ | ==Nikon== |
The lab currently has 3 Nikon Microscopes (Microscopes #2, #3 & #4). These are located in bays 6 and 7. The scopes are connected to computers via Jenoptik ProgRes software which allows users to digitally capture images through the microscope and make calibrated measurements. |
The lab currently has 3 Nikon Microscopes (Microscopes #2, #3 & #4). These are located in bays 6 and 7. The scopes are connected to computers via Jenoptik ProgRes software which allows users to digitally capture images through the microscope and make calibrated measurements. |
||
− | =Olympus= |
+ | ==Olympus== |
The lab currently has one Olympus microscope (Microscope #1) which is located in bay 3. |
The lab currently has one Olympus microscope (Microscope #1) which is located in bay 3. |
||
+ | == Olympus LEXT Confocal Microscope == |
||
⚫ | |||
+ | YOU ARE REQUIRED TO GET TRAINED on this tool before you are allowed to use it! Please contact the Tool Owner to get training. |
||
+ | The LEXT has a motorized stage, image stitching capabilities and some image measurement capabilities, in addition to the primary topographical measurement capabilities afforded by the laser-scanning confocal microscopy function. |
||
+ | |||
+ | See the main tool page for more info: [[Laser Scanning Confocal M-scope (Olympus LEXT)]] |
||
+ | |||
⚫ | |||
* [[UCSB NanoFab Microscope Training|Microscope Training]] - General procedures and info for using our microscopes |
* [[UCSB NanoFab Microscope Training|Microscope Training]] - General procedures and info for using our microscopes |
||
Revision as of 10:53, 25 July 2018
|
Nikon
The lab currently has 3 Nikon Microscopes (Microscopes #2, #3 & #4). These are located in bays 6 and 7. The scopes are connected to computers via Jenoptik ProgRes software which allows users to digitally capture images through the microscope and make calibrated measurements.
Olympus
The lab currently has one Olympus microscope (Microscope #1) which is located in bay 3.
Olympus LEXT Confocal Microscope
YOU ARE REQUIRED TO GET TRAINED on this tool before you are allowed to use it! Please contact the Tool Owner to get training.
The LEXT has a motorized stage, image stitching capabilities and some image measurement capabilities, in addition to the primary topographical measurement capabilities afforded by the laser-scanning confocal microscopy function.
See the main tool page for more info: Laser Scanning Confocal M-scope (Olympus LEXT)
Documentation
- Microscope Training - General procedures and info for using our microscopes