Dry Etching Recipes: Difference between revisions

From UCSB Nanofab Wiki
Jump to navigation Jump to search
(ICP2 AL2O3 R link)
(testing)
Line 2: Line 2:
{| class="wikitable" style="border: 1px solid #D0E7FF; background-color:#ffffff; text-align:center; font-size: 95%" border="1"
{| class="wikitable" style="border: 1px solid #D0E7FF; background-color:#ffffff; text-align:center; font-size: 95%" border="1"
|- bgcolor="#d0e7ff"
|- bgcolor="#d0e7ff"
! width="725" height="45" colspan="17" | <div style="font-size: 150%;">Dry Etching Recipes</div>
! colspan="17" width="725" height="45" | <div style="font-size: 150%;">Dry Etching Recipes</div>
|- bgcolor="#d0e7ff"
|- bgcolor="#d0e7ff"
| <!-- INTENTIONALLY LEFT BLANK -->
| <!-- INTENTIONALLY LEFT BLANK -->
! width="300" height="35" align="center" bgcolor="#d0e7ff" colspan="4" | '''[[RIE Etching Recipes|RIE Etching]]'''
! colspan="4" width="300" height="35" align="center" bgcolor="#d0e7ff" | '''[[RIE Etching Recipes|RIE Etching]]'''
! colspan="5" |'''[[ICP Etching Recipes|ICP Etching]]'''
! colspan="5" |'''[[ICP Etching Recipes|ICP Etching]]'''
! align="center" bgcolor="#d0e7ff" colspan="4" |'''[[Oxygen Plasma System Recipes|Oxygen Plasma Systems]]'''
! colspan="4" align="center" bgcolor="#d0e7ff" |'''[[Oxygen Plasma System Recipes|Oxygen Plasma Systems]]'''
! align="center" bgcolor="#d0e7ff" colspan="3" |'''[[Other Dry Etching Recipes|Other Dry Etchers]]'''
! colspan="3" align="center" bgcolor="#d0e7ff" |'''[[Other Dry Etching Recipes|Other Dry Etchers]]'''
|-
|-
! width="65" align="center" bgcolor="#d0e7ff" | '''Material'''
! width="65" align="center" bgcolor="#d0e7ff" | '''Material'''
Line 33: Line 33:
|
|
|
|
|[https://www.nanotech.ucsb.edu/wiki/index.php/TEST_PAGE?venotify=created TEST]
|
|
|
|
|

Revision as of 16:31, 6 April 2018

  • R = Recipe is available. Clicking this link will take you to the recipe.
  • A = Material is available for use, but no recipes are provided.
Dry Etching Recipes
RIE Etching ICP Etching Oxygen Plasma Systems Other Dry Etchers
Material RIE 1
(Retired)
RIE 2
(MRC)
RIE 3
(MRC)
RIE 5
(PlasmaTherm)
DSEIII
(PlasmaTherm)
Si Deep RIE
(PTI/Bosch)
ICP Etch 1
(Panasonic 1)
ICP Etch 2
(Panasonic 2)
ICP-Etch
(Unaxis VLR)
Ashers
(Technics PEII)
Plasma Clean
(Gasonics 2000)
UV Ozone Reactor Plasma Activation
(EVG 810)
XeF2 Etch
(Xetch)
Vapor HF Etch
(uETCH)
CAIBE
(Oxford)
Ag TEST
Al A R1 R1
Au R1
Cr A R1 A
Cu
Ge A
Mo
Ni R1
Pt R1
Ru
Si R1 R1 R1
Ta
Ti R1 A
Al2O3 R
Al2O3 (Sapphire) R1 A
AlGaAs R1 R1 GaAs-AlGaAs Etch (Unaxis VLR)
AlGaN R1
AlN R1
CdZnTe R1
GaAs R1 R1 R1 GaAs-AlGaAs Etch (Unaxis VLR)
GaN R1 R1 R1
GaSb A GaSb Etch Unaxis VLR)
HfO2
InGaAlAs InP-InGaAsP-InGaAlAs Etching (RIE 2) InP-InGaAs-InAlAs Etch (Unaxis VLR)
InGaAsP InP-InGaAsP-InGaAlAs Etching (RIE 2) InP-InGaAs-InAlAs Etch (Unaxis VLR)
InP InP-InGaAsP-InGaAlAs Etching (RIE 2) A A InP-InGaAs-InAlAs Etch (Unaxis VLR)
ITO R1
Photoresist

& ARC

A A A R A A
SiC R1 A
SiN SiNx Etching (RIE 3) R1 R1 A
SiO2 SiO2 Etching (RIE 3) R1 R1 R1
SiOxNy A A
Ta2O5 A
TiN
TiO2
W-TiW R1 A
ZnO2
ZnS R1
ZnSe R1
ZrO2
Material RIE 1
(Retired)
RIE 2
(MRC)
RIE 3
(MRC)
RIE 5
(PlasmaTherm)
DSEIII
(PlasmaTherm)
Si Deep RIE
(PlasmaTherm/Bosch Etch)
ICP Etch 1
(Panasonic E626I)
ICP Etch 2
(Panasonic E640)
ICP-Etch
(Unaxis VLR)
Ashers
(Technics PEII)
Plasma Clean
(Gasonics 2000)
UV Ozone Reactor Plasma Activation
(EVG 810)
XeF2 Etch
(Xetch)
Vapor HF Etch
(uETCH)
CAIBE
(Oxford)