Dicing Saw (ADT): Difference between revisions
Jump to navigation
Jump to search
(Updated SOP) |
(Added UV tape TDS link) |
||
(4 intermediate revisions by the same user not shown) | |||
Line 4: | Line 4: | ||
|super= Lee Sawyer |
|super= Lee Sawyer |
||
|super2= Aidan Hopkins |
|super2= Aidan Hopkins |
||
|location= |
|location=Backend Lab: ESB 1111 |
||
|description = ADT Dicing Saw |
|description = ADT Dicing Saw |
||
|model = ADT 7100 |
|model = ADT 7100 |
||
Line 12: | Line 12: | ||
}} |
}} |
||
==About== |
==About== |
||
The Model 7100 Series is a semi-automatic dicing saw. Semiconductor, glass, and plastic substrates of all types can be automatically or manually cut. This dicing Saw is optimized for multi-angle dicing of tight tolerance substrates up to 200 mm diameter in size. |
|||
⚫ | |||
⚫ | |||
⚫ | |||
⚫ | |||
⚫ | |||
⚫ | |||
==Detailed Specifications== |
==Detailed Specifications== |
||
*Maximum Wafer Size: 8" |
*Maximum Wafer Size: 8" |
||
*Parts mounted to UV-release tape for |
*Parts mounted to UV-release tape for dicing |
||
*Automated cut maps at multiple angles (0° and 90° typical) |
*Automated cut maps at multiple angles (0° and 90° typical) |
||
*~ |
*~Few micron alignment to on-wafer features. |
||
*Thermocarbon Resnoid dicing blades provided by |
*Thermocarbon Resnoid dicing blades provided by Staff |
||
==Operating Procedures== |
==Operating Procedures== |
||
*[https://wiki. |
*[https://wiki.nanofab.ucsb.edu/w/images/b/b0/ADT_SOP_Rev_I.pdf ADT Dicing Saw Standard Operating Procedure] |
||
*[https://wiki.nanotech.ucsb.edu/w/images/0/01/Tape_Station_SOP_Rev_A.pdf Tape Station Standard Operating Procedure] |
*[https://wiki.nanotech.ucsb.edu/w/images/0/01/Tape_Station_SOP_Rev_A.pdf Tape Station Standard Operating Procedure] |
||
*[https://wiki.nanofab.ucsb.edu/w/images/5/5a/Ultron_1042R_Film_specs.pdf Ultron Systems, Inc. 1042R Anti-Static Ultraviolet Film TDS] |
|||
*[[ADT 7100 - Recovering an Old Recipe (2019)|Recovering an Old Recipe]] |
*[[ADT 7100 - Recovering an Old Recipe (2019)|Recovering an Old Recipe]] |
||
Revision as of 15:24, 13 September 2023
|
About
The Model 7100 Series is a semi-automatic dicing saw. Semiconductor, glass, and plastic substrates of all types can be automatically or manually cut. This dicing Saw is optimized for multi-angle dicing of tight tolerance substrates up to 200 mm diameter in size.
Check the Dicing Saw Recipes page for the blades we currently stock.
An ADT WM-966 tape applicator is used to mount samples to UV-release tape for dicing and an Ultron Systems UH104-8 UV lamp system is used to release samples post dicing.
Contact Staff for blades and dicing frames for your group.
Detailed Specifications
- Maximum Wafer Size: 8"
- Parts mounted to UV-release tape for dicing
- Automated cut maps at multiple angles (0° and 90° typical)
- ~Few micron alignment to on-wafer features.
- Thermocarbon Resnoid dicing blades provided by Staff
Operating Procedures
- ADT Dicing Saw Standard Operating Procedure
- Tape Station Standard Operating Procedure
- Ultron Systems, Inc. 1042R Anti-Static Ultraviolet Film TDS
- Recovering an Old Recipe
Recipes
- Recipes > Packaging > Dicing Saw Recipes (ADT 7100)
Be sure to also see the recipes for protecting your sample from dicing dust, and mounting/unmounting.