Nanofab Staff Internal Pages: Difference between revisions
Jump to navigation
Jump to search
(added placeholders for other sections) |
Mehalana v (talk | contribs) (restic update) |
||
(41 intermediate revisions by 2 users not shown) | |||
Line 1: | Line 1: | ||
This page is intended for NanoFab Staff, internal. |
|||
==Equipment Group== |
|||
== Video Training procedures == |
|||
* Recording your Training Video: |
|||
*[[Equipment Group - Video Training Procedures|Video Training Procedures]] - How to record, edit and publish a video training. |
|||
** [[GoPro Hero8 Black (Internal)|GoPro Hero8 Black]] - used for recording training videos. |
|||
* Uploading your files to the Video Editing workstation: TBA |
|||
==Process Group== |
|||
* Uploading your files to GauchoCast/Panopto: TBA |
|||
*[[Process Group - Remote Fabrication Jobs|'''Job Tracking''']] - pages to organize and track our remote 'fab service jobs |
|||
*[[Process Group - Billing Instructions|Billing Instructions (RechargeApp)]] - info on entering billing into RechargeApp. |
|||
**''Includes [[Process Group - Billing Instructions#Supplies Costs|Supplies Costs]].'' |
|||
*[[ASML Stepper 3 Dicing Guide Programming|ASML Dicing Guide Programming]] - how to print dicing guides on a wafer |
|||
*[[Process Group - Process Control Data|Process Control Data]] - all the links to process calibration/repeatability data in one place. |
|||
==NanoFab IT== |
|||
''Computers, Networks, FTP/File-Sync etc.'' |
|||
*Instructions+Procedures can be found in ''gDrive > Facilities Group > Computer Systems'' |
|||
*'''Unifi Network SDN''' |
|||
*#Network Hardware Maintenance |
|||
*##Add/Remover User for Unifi Network Controller |
|||
*#Switch Maintenance |
|||
*##Restart |
|||
*##Reset |
|||
*#Add/Replace new Switch visit [https://store.ui.com/us/en store.ui.com/us/en] we are using follow switch below |
|||
*##switching-standard 48/24/16 ports |
|||
*##switching-aggregation 8 Ports |
|||
*##Flex Mini 5 Ports |
|||
*#Add/ Replace Fail SFP Receiver When searching in the Maintenance Shop, locate the bin labeled SFP Receiver & look for 1000 BASE-LX 1310-nm SFP Receiver |
|||
*#Add/ Replace Fail Fiber Cable When searching in the Maintenance Shop, locate the bin labeled Fiber LC to SC and search for the Optical Fiber Patch Cable. |
|||
*#Add/Replace the Ethernet patch We have four length of the patch cable 3/5/10/15 ft located in the Tel/Data RM#1117 In both case please update the [https://docs.google.com/spreadsheets/d/1iPc4Sxh8ge2mc0hhXlqS6ofckT8nzfrw9QcWefoLMa8/edit?usp=sharing IT Hardware Log] Sheet: '''Eth Ports''', '''Endpoints''' |
|||
*##Patch Pannel to Switch Label format : <<sw-name>>-<<port-number>> |
|||
*##System to Wall Port Lable format : Nanofile-Network 10.1.1.1/16 |
|||
*'''Synology''' |
|||
*#Active Backup for Business |
|||
*##Add new device |
|||
*##Add new server |
|||
*##Restore a device |
|||
*#Create a new Network Share Folder |
|||
*#Add a Device to Apple Time Machine |
|||
*#Server Maintenance |
|||
*'''Nanofiles''' |
|||
*#Failover (CARP) |
|||
*#Restart |
|||
*#Restore |
|||
*#[[Nanofab-IT - Add Device to Network|Add Device to Network]] |
|||
*#Nanofile Sync |
|||
*##Add a new Device |
|||
*###Make sure Device is connected to Nanofiles |
|||
*###Connect the Network drive \\nanofiles\staff |
|||
*###Copy '''grsync''' directory from the network and paste it to '''c:\''' drive |
|||
*###Run the '''Init.bat''' in the grsync directory, press enter twice (make sure do not enter any password) besides remember the part of the stored SSH key |
|||
*###open the sync.bat in notepad change |
|||
*####'''<code>SET MACHINE=[host-name]</code>''' |
|||
*####create a nanofiles - userdata directory in public folder Note : In case of Drive change use this syntax '''<code>/cygdrive/[drive-letter]/</code>''' |
|||
*##Replace a Device |
|||
*#Generating New WireGard VPN Credentials |
|||
*##Server-Side |
|||
*###Commend for generating the keys: <code>cd /etc/wiregard</code> <code>wg genkey tee privatekey_<<replace it with username>> | wg pubkey > publickey_<<replace it with username>></code> |
|||
*###Add a new line in /etc/hostname.wg0: <code>wgpeer <<public_key_of_new_user>> wgaip 10.1.10.XXX/32</code> |
|||
*###Service Restart: <code>sh /etc/netstart wg0</code> |
|||
*##Client-Side |
|||
*###'''Generate the a new file with .conf extension''' <code>[Interface]</code> <code>PrivateKey = <<privatekey_of_new_user>></code> <code>Address = 10.1.10.XXX/32</code> <code>DNS = 10.1.1.1</code> <code>[Peer]</code> <code>PublicKey = hHngYmJZUxRfLAmCxhC00m80hjsNDKl4LKV4iDYN+TY= </code> <code>AllowedIPs = 10.1.0.0/16</code> <code>Endpoint = nanofiles1.ece.ucsb.edu:5900</code> <code>PersistentKeepalive = 25</code> |
|||
*'''Signupmonkey''' |
|||
**Failover |
|||
**Restart |
|||
**Restore |
|||
*'''RechargeApp''' |
|||
**Failover |
|||
**Restart |
|||
**Restore |
|||
*'''Nanofabserver2''' |
|||
**Restart |
|||
**Restore |
|||
*'''DataGrove''' |
|||
**Restore Backup |
|||
**#Login to nanofiles2 |
|||
**#Get the list of the Snapshots: <code>restic -p /etc/restic-pwd --repo sftp:restic@datagrove:/srv/backup snapshots</code> |
|||
**#To view files within a snapshot: <code>restic -p /etc/restic-pwd --repo sftp:restic@datagrove:/srv/backup ls -l [snapshort-id] | grep "[dir-path-to-search]"</code> |
|||
**#To restore a single directory: <code>restic -p /etc/restic-pwd --repo sftp:restic@datagrove:/srv/backup restore [snapshort-id] --target [dir-path-save-restore-data] --include [dir-path-to-restore]</code> |
|||
**Note: Please replace all value in [square-bracket] as mention |
|||
*'''NanoFab Wiki''' |
|||
**Restart |
|||
**Restore |
|||
*'''NanoFab Server UPS''' |
|||
**Battery Test |
|||
*'''Utilities Software''' |
|||
*#LogMeIn |
|||
*##Add a new Device |
|||
*##Add a new user |
|||
*##Remove a External/Internal User <br /> |
|||
==Administration== |
|||
*[[Nanofab New User Onboarding|Nanofab New User Onboarding - UCSB Users]] - To-do list for new internal-UCSB users |
|||
*[[Nanofab New User Onboarding - External Users]] - To-do list for new External users traveling from elsewhere |
|||
==Useful UCSB Pages== |
|||
*[https://www.dfss.ucsb.edu/facilities-management/work-request Facilities Work Requests] - Here's where you report facilities repair requests, like replacing light bulbs, building problems (doors, elevators) etc. |
|||
==Old / Defunct== |
|||
''Old pages we don't use on the Wiki anymore, but are kept for possible utility later on.'' |
|||
*[[Process Group - Lab Stocking/Supplies Tasks|Lab Stocking/Supplies Tasks]] - Not needed anymore 2021-02 |
|||
*[[Old Deposition Data - 2021-12-15]] - removed from main Dep pages |
|||
**New [[Old Deposition Data - NastaziaM 2021-11-22|Deposition Data - NastaziaM 2021-11-22]] - combo of old & new links. Can probably be safely deleted. |
|||
**[[Deposition Data - temporary 2021-12-15|Deposition Data - temporary 2021-12-15]] - staging for new links, copied to PECVD/Sputter Recipes pages on 2021-12-15. This can probably be safely deleted. |
Revision as of 00:39, 7 November 2023
This page is intended for NanoFab Staff, internal.
Equipment Group
- Video Training Procedures - How to record, edit and publish a video training.
Process Group
- Job Tracking - pages to organize and track our remote 'fab service jobs
- Billing Instructions (RechargeApp) - info on entering billing into RechargeApp.
- Includes Supplies Costs.
- ASML Dicing Guide Programming - how to print dicing guides on a wafer
- Process Control Data - all the links to process calibration/repeatability data in one place.
NanoFab IT
Computers, Networks, FTP/File-Sync etc.
- Instructions+Procedures can be found in gDrive > Facilities Group > Computer Systems
- Unifi Network SDN
- Network Hardware Maintenance
- Add/Remover User for Unifi Network Controller
- Switch Maintenance
- Restart
- Reset
- Add/Replace new Switch visit store.ui.com/us/en we are using follow switch below
- switching-standard 48/24/16 ports
- switching-aggregation 8 Ports
- Flex Mini 5 Ports
- Add/ Replace Fail SFP Receiver When searching in the Maintenance Shop, locate the bin labeled SFP Receiver & look for 1000 BASE-LX 1310-nm SFP Receiver
- Add/ Replace Fail Fiber Cable When searching in the Maintenance Shop, locate the bin labeled Fiber LC to SC and search for the Optical Fiber Patch Cable.
- Add/Replace the Ethernet patch We have four length of the patch cable 3/5/10/15 ft located in the Tel/Data RM#1117 In both case please update the IT Hardware Log Sheet: Eth Ports, Endpoints
- Patch Pannel to Switch Label format : <<sw-name>>-<<port-number>>
- System to Wall Port Lable format : Nanofile-Network 10.1.1.1/16
- Network Hardware Maintenance
- Synology
- Active Backup for Business
- Add new device
- Add new server
- Restore a device
- Create a new Network Share Folder
- Add a Device to Apple Time Machine
- Server Maintenance
- Active Backup for Business
- Nanofiles
- Failover (CARP)
- Restart
- Restore
- Add Device to Network
- Nanofile Sync
- Add a new Device
- Make sure Device is connected to Nanofiles
- Connect the Network drive \\nanofiles\staff
- Copy grsync directory from the network and paste it to c:\ drive
- Run the Init.bat in the grsync directory, press enter twice (make sure do not enter any password) besides remember the part of the stored SSH key
- open the sync.bat in notepad change
SET MACHINE=[host-name]
- create a nanofiles - userdata directory in public folder Note : In case of Drive change use this syntax
/cygdrive/[drive-letter]/
- Replace a Device
- Add a new Device
- Generating New WireGard VPN Credentials
- Server-Side
- Commend for generating the keys:
cd /etc/wiregard
wg genkey tee privatekey_<<replace it with username>> | wg pubkey > publickey_<<replace it with username>>
- Add a new line in /etc/hostname.wg0:
wgpeer <<public_key_of_new_user>> wgaip 10.1.10.XXX/32
- Service Restart:
sh /etc/netstart wg0
- Commend for generating the keys:
- Client-Side
- Generate the a new file with .conf extension
[Interface]
PrivateKey = <<privatekey_of_new_user>>
Address = 10.1.10.XXX/32
DNS = 10.1.1.1
[Peer]
PublicKey = hHngYmJZUxRfLAmCxhC00m80hjsNDKl4LKV4iDYN+TY=
AllowedIPs = 10.1.0.0/16
Endpoint = nanofiles1.ece.ucsb.edu:5900
PersistentKeepalive = 25
- Generate the a new file with .conf extension
- Server-Side
- Signupmonkey
- Failover
- Restart
- Restore
- RechargeApp
- Failover
- Restart
- Restore
- Nanofabserver2
- Restart
- Restore
- DataGrove
- Restore Backup
- Login to nanofiles2
- Get the list of the Snapshots:
restic -p /etc/restic-pwd --repo sftp:restic@datagrove:/srv/backup snapshots
- To view files within a snapshot:
restic -p /etc/restic-pwd --repo sftp:restic@datagrove:/srv/backup ls -l [snapshort-id] | grep "[dir-path-to-search]"
- To restore a single directory:
restic -p /etc/restic-pwd --repo sftp:restic@datagrove:/srv/backup restore [snapshort-id] --target [dir-path-save-restore-data] --include [dir-path-to-restore]
- Note: Please replace all value in [square-bracket] as mention
- Restore Backup
- NanoFab Wiki
- Restart
- Restore
- NanoFab Server UPS
- Battery Test
- Utilities Software
- LogMeIn
- Add a new Device
- Add a new user
- Remove a External/Internal User
- LogMeIn
Administration
- Nanofab New User Onboarding - UCSB Users - To-do list for new internal-UCSB users
- Nanofab New User Onboarding - External Users - To-do list for new External users traveling from elsewhere
Useful UCSB Pages
- Facilities Work Requests - Here's where you report facilities repair requests, like replacing light bulbs, building problems (doors, elevators) etc.
Old / Defunct
Old pages we don't use on the Wiki anymore, but are kept for possible utility later on.
- Lab Stocking/Supplies Tasks - Not needed anymore 2021-02
- Old Deposition Data - 2021-12-15 - removed from main Dep pages
- New Deposition Data - NastaziaM 2021-11-22 - combo of old & new links. Can probably be safely deleted.
- Deposition Data - temporary 2021-12-15 - staging for new links, copied to PECVD/Sputter Recipes pages on 2021-12-15. This can probably be safely deleted.