Difference between revisions of "Dry Etching Recipes"
Jump to navigation
Jump to search
m (Change A to R1 per Demis, almost all A have been done before.) |
|||
(27 intermediate revisions by 3 users not shown) | |||
Line 6: | Line 6: | ||
{| class="wikitable" style="border: 1px solid #D0E7FF; background-color:#ffffff; text-align:center; font-size: 95%" border="1" |
{| class="wikitable" style="border: 1px solid #D0E7FF; background-color:#ffffff; text-align:center; font-size: 95%" border="1" |
||
|- |
|- |
||
− | ! colspan=" |
+ | ! colspan="15" width="725" height="45" |<div style="font-size: 150%;">Dry Etching Recipes</div> |
|- bgcolor="#d0e7ff" |
|- bgcolor="#d0e7ff" |
||
| bgcolor="#eaecf0" |<!-- INTENTIONALLY LEFT BLANK --> |
| bgcolor="#eaecf0" |<!-- INTENTIONALLY LEFT BLANK --> |
||
− | ! colspan=" |
+ | ! colspan="2" |'''[[RIE Etching Recipes|RIE Etching]]''' |
− | ! colspan=" |
+ | ! colspan="5" |'''[[ICP Etching Recipes|ICP Etching]]''' |
! colspan="4" bgcolor="#d0e7ff" align="center" |'''[[Oxygen Plasma System Recipes|Oxygen Plasma Systems]]''' |
! colspan="4" bgcolor="#d0e7ff" align="center" |'''[[Oxygen Plasma System Recipes|Oxygen Plasma Systems]]''' |
||
! colspan="3" bgcolor="#d0e7ff" align="center" |'''[[Other Dry Etching Recipes|Other Dry Etchers]]''' |
! colspan="3" bgcolor="#d0e7ff" align="center" |'''[[Other Dry Etching Recipes|Other Dry Etchers]]''' |
||
Line 16: | Line 16: | ||
! bgcolor="#d0e7ff" align="center" |'''Material''' |
! bgcolor="#d0e7ff" align="center" |'''Material''' |
||
| bgcolor="#daf1ff" |[[RIE_Etching_Recipes#RIE_2_.28MRC.29|RIE 2<br> <span style="font-size: 88%;">(MRC)</span>]] |
| bgcolor="#daf1ff" |[[RIE_Etching_Recipes#RIE_2_.28MRC.29|RIE 2<br> <span style="font-size: 88%;">(MRC)</span>]] |
||
− | | bgcolor="#daf1ff" |[[RIE_Etching_Recipes#RIE_3_.28MRC.29|RIE 3<br> <span style="font-size: 88%;">(MRC)</span>]] |
||
| bgcolor="#daf1ff" |[[RIE_Etching_Recipes#RIE_5_.28PlasmaTherm.29|RIE 5<br><span style="font-size: 88%;">(PlasmaTherm)</span>]] |
| bgcolor="#daf1ff" |[[RIE_Etching_Recipes#RIE_5_.28PlasmaTherm.29|RIE 5<br><span style="font-size: 88%;">(PlasmaTherm)</span>]] |
||
| bgcolor="#daf1ff" |[[ICP_Etching_Recipes#DSEIII_.28PlasmaTherm.2FDeep_Silicon_Etcher.29|DSEIII<br><span style="font-size: 88%;">(PlasmaTherm)</span>]] |
| bgcolor="#daf1ff" |[[ICP_Etching_Recipes#DSEIII_.28PlasmaTherm.2FDeep_Silicon_Etcher.29|DSEIII<br><span style="font-size: 88%;">(PlasmaTherm)</span>]] |
||
Line 23: | Line 22: | ||
| bgcolor="#daf1ff" |[[ICP Etching Recipes#ICP Etch 2 .28Panasonic E626I.29|ICP Etch 2<br><span style="font-size: 88%;">(Panasonic E626I)</span>]] |
| bgcolor="#daf1ff" |[[ICP Etching Recipes#ICP Etch 2 .28Panasonic E626I.29|ICP Etch 2<br><span style="font-size: 88%;">(Panasonic E626I)</span>]] |
||
| bgcolor="#daf1ff" |[[ICP Etching Recipes#Oxford ICP Etcher .28PlasmaPro 100 Cobra.29|Oxford ICP <span style="font-size: 88%;">(PlasmaPro 100)</span>]] |
| bgcolor="#daf1ff" |[[ICP Etching Recipes#Oxford ICP Etcher .28PlasmaPro 100 Cobra.29|Oxford ICP <span style="font-size: 88%;">(PlasmaPro 100)</span>]] |
||
− | | bgcolor="#daf1ff" |[[ICP_Etching_Recipes#ICP-Etch_.28Unaxis_VLR.29|ICP-Etch<br><span style="font-size: 88%;">(Unaxis VLR)</span>]] |
||
| bgcolor="#daf1ff" |[[Oxygen_Plasma_System_Recipes#Ashers_.28Technics_PEII.29|Ashers<br><span style="font-size: 88%;">(Technics PEII)</span>]] |
| bgcolor="#daf1ff" |[[Oxygen_Plasma_System_Recipes#Ashers_.28Technics_PEII.29|Ashers<br><span style="font-size: 88%;">(Technics PEII)</span>]] |
||
| bgcolor="#daf1ff" |[[Oxygen Plasma System Recipes#Plasma Clean .28YES EcoClean.29|Plasma Clean <span style="font-size: 88%;">(YES EcoClean)</span>]] |
| bgcolor="#daf1ff" |[[Oxygen Plasma System Recipes#Plasma Clean .28YES EcoClean.29|Plasma Clean <span style="font-size: 88%;">(YES EcoClean)</span>]] |
||
Line 46: | Line 44: | ||
| |
| |
||
| |
| |
||
− | | |
+ | |R1 |
− | | |
||
− | |A |
||
|- bgcolor="#ffffff" |
|- bgcolor="#ffffff" |
||
! bgcolor="#d0e7ff" align="center" |Al |
! bgcolor="#d0e7ff" align="center" |Al |
||
| |
| |
||
+ | |[[RIE Etching Recipes|R2]] |
||
| |
| |
||
− | |[[RIE Etching Recipes|A]] |
||
| |
| |
||
+ | |{{rl|ICP Etching Recipes|Al Etch (Panasonic 1)|R1}} |
||
+ | |[[ICP Etching Recipes#Al Etch .28Panasonic 2.29|R2]] |
||
| |
| |
||
− | |{{rl|ICP Etching Recipes|Al Etch (Panasonic 1)}} |
||
− | |{{rl|ICP Etching Recipes|Al Etch (Panasonic 2)}} |
||
| |
| |
||
| |
| |
||
Line 64: | Line 60: | ||
| |
| |
||
| |
| |
||
− | | |
+ | |R1 |
− | | |
||
− | |A |
||
|- bgcolor="#eeffff" |
|- bgcolor="#eeffff" |
||
! bgcolor="#d0e7ff" align="center" |Au |
! bgcolor="#d0e7ff" align="center" |Au |
||
Line 82: | Line 76: | ||
| |
| |
||
| |
| |
||
+ | |[[Other Dry Etching Recipes|R4]] |
||
− | | |
||
− | | |
||
− | |{{rl|Other Dry Etching Recipes|Other Dry Etch (CAIBE (Oxford Ion Mill))}} |
||
|- bgcolor="#ffffff" |
|- bgcolor="#ffffff" |
||
! bgcolor="#d0e7ff" align="center" |Cr |
! bgcolor="#d0e7ff" align="center" |Cr |
||
| |
| |
||
+ | |[[RIE Etching Recipes|R2]] |
||
− | | |
||
− | |A |
||
| |
| |
||
| |
| |
||
|{{rl|ICP Etching Recipes|Cr Etch (Panasonic 1)}} |
|{{rl|ICP Etching Recipes|Cr Etch (Panasonic 1)}} |
||
− | | |
+ | |R1 |
| |
| |
||
| |
| |
||
Line 101: | Line 92: | ||
| |
| |
||
| |
| |
||
− | | |
+ | |R1 |
− | |A |
||
|- bgcolor="#eeffff" |
|- bgcolor="#eeffff" |
||
! bgcolor="#d0e7ff" align="center" |Cu |
! bgcolor="#d0e7ff" align="center" |Cu |
||
Line 118: | Line 108: | ||
| |
| |
||
| |
| |
||
− | | |
+ | |R1 |
− | | |
||
− | |A |
||
|- bgcolor="#ffffff" |
|- bgcolor="#ffffff" |
||
! bgcolor="#d0e7ff" align="center" |Ge |
! bgcolor="#d0e7ff" align="center" |Ge |
||
− | | |
||
| |
| |
||
| |
| |
||
Line 129: | Line 116: | ||
| |
| |
||
|A |
|A |
||
− | | |
+ | |R1 |
| |
| |
||
| |
| |
||
Line 135: | Line 122: | ||
| |
| |
||
| |
| |
||
+ | |[[Other Dry Etching Recipes|R2]] |
||
| |
| |
||
− | | |
+ | |R1 |
− | | |
||
− | |A |
||
|- bgcolor="#eeffff" |
|- bgcolor="#eeffff" |
||
! bgcolor="#d0e7ff" align="center" |Mo |
! bgcolor="#d0e7ff" align="center" |Mo |
||
Line 154: | Line 140: | ||
| |
| |
||
| |
| |
||
− | | |
+ | |R1 |
− | | |
||
− | |A |
||
|- |
|- |
||
!Nb |
!Nb |
||
− | | |
||
| |
| |
||
| |
| |
||
Line 165: | Line 148: | ||
| |
| |
||
|A |
|A |
||
− | | |
+ | |R1 |
− | | |
||
| |
| |
||
| |
| |
||
Line 190: | Line 172: | ||
| |
| |
||
| |
| |
||
+ | |[[Other Dry Etching Recipes|R4]] |
||
− | | |
||
− | | |
||
− | |{{rl|Other Dry Etching Recipes|Other Dry Etch (CAIBE (Oxford Ion Mill))}} |
||
|- |
|- |
||
!Os |
!Os |
||
− | | |
||
| |
| |
||
| |
| |
||
Line 201: | Line 180: | ||
| |
| |
||
|A |
|A |
||
− | | |
+ | |R1 |
− | | |
||
| |
| |
||
| |
| |
||
Line 226: | Line 204: | ||
| |
| |
||
| |
| |
||
+ | |[[Other Dry Etching Recipes|R4]] |
||
− | | |
||
− | | |
||
− | |{{rl|Other Dry Etching Recipes|Other Dry Etch (CAIBE (Oxford Ion Mill))}} |
||
|- bgcolor="#ffffff" |
|- bgcolor="#ffffff" |
||
! bgcolor="#d0e7ff" align="center" |Ru |
! bgcolor="#d0e7ff" align="center" |Ru |
||
− | | |
||
| |
| |
||
| |
| |
||
Line 237: | Line 212: | ||
| |
| |
||
|A |
|A |
||
− | | |
+ | |[[ICP Etching Recipes#Ru .28Ruthenium.29 Etch .28Panasonic 2.29|R3]] |
| |
| |
||
| |
| |
||
Line 245: | Line 220: | ||
| |
| |
||
| |
| |
||
− | | |
+ | |R1 |
− | |A |
||
|- bgcolor="#eeffff" |
|- bgcolor="#eeffff" |
||
! bgcolor="#d0e7ff" align="center" |Si |
! bgcolor="#d0e7ff" align="center" |Si |
||
| |
| |
||
| |
| |
||
+ | |[[ICP Etching Recipes#DSEIII .28PlasmaTherm.2FDeep Silicon Etcher.29|R4]] |
||
− | | |
||
+ | |[[ICP Etching Recipes#Si Etching .28Fluorine ICP Etcher.29|R5]] |
||
− | |{{rl|ICP Etching Recipes|DSEIII_(PlasmaTherm/Deep_Silicon_Etcher)}} |
||
− | |[[ICP Etching Recipes#Si Etching .28Fluorine ICP Etcher.29|R3]] |
||
| |
| |
||
| |
| |
||
Line 261: | Line 234: | ||
| |
| |
||
| |
| |
||
+ | |[[Other Dry Etching Recipes|R4]] |
||
| |
| |
||
+ | |R1 |
||
− | |{{rl|Other Dry Etching Recipes|Other Dry Etch (XeF2 Etcher)}} |
||
− | | |
||
− | |A |
||
|- bgcolor="#ffffff" |
|- bgcolor="#ffffff" |
||
! bgcolor="#d0e7ff" align="center" |Ta |
! bgcolor="#d0e7ff" align="center" |Ta |
||
− | | |
||
| |
| |
||
| |
| |
||
Line 273: | Line 244: | ||
| |
| |
||
|A |
|A |
||
− | | |
+ | |R1 |
| |
| |
||
| |
| |
||
Line 281: | Line 252: | ||
| |
| |
||
| |
| |
||
− | | |
+ | |R1 |
− | |A |
||
|- bgcolor="#eeffff" |
|- bgcolor="#eeffff" |
||
! bgcolor="#d0e7ff" align="center" |Ti |
! bgcolor="#d0e7ff" align="center" |Ti |
||
− | | |
||
| |
| |
||
| |
| |
||
Line 291: | Line 260: | ||
| |
| |
||
|{{rl|ICP Etching Recipes|Ti Etch (Panasonic 1)}} |
|{{rl|ICP Etching Recipes|Ti Etch (Panasonic 1)}} |
||
− | | |
+ | |R1 |
| |
| |
||
| |
| |
||
Line 299: | Line 268: | ||
| |
| |
||
| |
| |
||
− | | |
+ | |R1 |
− | |A |
||
|- bgcolor="#ffffff" |
|- bgcolor="#ffffff" |
||
− | ! bgcolor="#d0e7ff" align="center" | |
+ | ! bgcolor="#d0e7ff" align="center" |W |
| |
| |
||
| |
| |
||
| |
| |
||
+ | |R2 |
||
+ | |{{rl|ICP Etching Recipes|W-TiW Etch (Panasonic 1)}} |
||
+ | |R1 |
||
| |
| |
||
| |
| |
||
− | |A |
||
− | |[https://wiki.nanotech.ucsb.edu/w/index.php?title=ICP_Etching_Recipes#Al2O3_Etching_.28Panasonic_2.29 R] |
||
| |
| |
||
| |
| |
||
| |
| |
||
| |
| |
||
+ | | |
||
+ | |R1 |
||
+ | |- |
||
+ | !TiW |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | |R2 |
||
+ | | |
||
+ | |R1 |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | |- bgcolor="#ffffff" |
||
+ | ! bgcolor="#d0e7ff" align="center" |Al<sub>2</sub>O<sub>3</sub> |
||
| |
| |
||
| |
| |
||
Line 319: | Line 308: | ||
| |
| |
||
|A |
|A |
||
+ | |[[ICP Etching Recipes#Al2O3 Etching .28Panasonic 2.29|R3]] |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | |R1 |
||
|- bgcolor="#eeffff" |
|- bgcolor="#eeffff" |
||
! bgcolor="#d0e7ff" align="center" |Al<sub>2</sub>O<sub>3 (Sapphire)</sub> |
! bgcolor="#d0e7ff" align="center" |Al<sub>2</sub>O<sub>3 (Sapphire)</sub> |
||
− | | |
||
| |
| |
||
| |
| |
||
Line 327: | Line 324: | ||
| |
| |
||
|{{rl|ICP Etching Recipes|Sapphire Etch (Panasonic 1)}} |
|{{rl|ICP Etching Recipes|Sapphire Etch (Panasonic 1)}} |
||
− | | |
+ | |R1 |
| |
| |
||
| |
| |
||
Line 335: | Line 332: | ||
| |
| |
||
| |
| |
||
− | | |
+ | |R1 |
− | |A |
||
|- bgcolor="#ffffff" |
|- bgcolor="#ffffff" |
||
! bgcolor="#d0e7ff" align="center" |AlGaAs |
! bgcolor="#d0e7ff" align="center" |AlGaAs |
||
| |
| |
||
+ | |[[RIE Etching Recipes|R3]] |
||
− | | |
||
− | |{{rl|RIE Etching Recipes|AlGaAs\GaAs Etching (RIE 5)}} |
||
| |
| |
||
| |
| |
||
Line 347: | Line 342: | ||
| |
| |
||
|[[ICP Etching Recipes#GaAs Etch .28Oxford ICP Etcher.29|R3]] |
|[[ICP Etching Recipes#GaAs Etch .28Oxford ICP Etcher.29|R3]] |
||
− | |{{rl|ICP Etching Recipes|ICP-Etch (Unaxis VLR)|GaAs-AlGaAs Etch (Unaxis VLR)|AlGaAs Etch (Unaxis VLR)}} |
||
| |
| |
||
| |
| |
||
Line 354: | Line 348: | ||
| |
| |
||
| |
| |
||
− | | |
+ | |R1 |
|- bgcolor="#eeffff" |
|- bgcolor="#eeffff" |
||
! bgcolor="#d0e7ff" align="center" |AlGaN |
! bgcolor="#d0e7ff" align="center" |AlGaN |
||
− | | |
||
| |
| |
||
| |
| |
||
Line 365: | Line 358: | ||
| |
| |
||
|[[ICP Etching Recipes#GaN Etch .28Oxford ICP Etcher.29|R2]] |
|[[ICP Etching Recipes#GaN Etch .28Oxford ICP Etcher.29|R2]] |
||
− | |{{rl|ICP Etching Recipes|GaN Etch (Unaxis VLR)}} |
||
| |
| |
||
| |
| |
||
Line 372: | Line 364: | ||
| |
| |
||
| |
| |
||
− | | |
+ | |R1 |
|- bgcolor="#ffffff" |
|- bgcolor="#ffffff" |
||
! bgcolor="#d0e7ff" align="center" |AlN |
! bgcolor="#d0e7ff" align="center" |AlN |
||
Line 383: | Line 375: | ||
| |
| |
||
| |
| |
||
− | |{{rl|ICP Etching Recipes|GaN Etch (Unaxis VLR)}} |
||
| |
| |
||
| |
| |
||
Line 389: | Line 380: | ||
| |
| |
||
| |
| |
||
− | | |
+ | |R1 |
− | |A |
||
|- |
|- |
||
!BCB |
!BCB |
||
− | | |
||
| |
| |
||
| |
| |
||
Line 399: | Line 388: | ||
| |
| |
||
|A |
|A |
||
− | | |
||
| |
| |
||
| |
| |
||
Line 411: | Line 399: | ||
|- bgcolor="#eeffff" |
|- bgcolor="#eeffff" |
||
! bgcolor="#d0e7ff" align="center" |CdZnTe |
! bgcolor="#d0e7ff" align="center" |CdZnTe |
||
− | | |
+ | |[[RIE Etching Recipes|R3]] |
| |
| |
||
| |
| |
||
Line 424: | Line 412: | ||
| |
| |
||
| |
| |
||
− | | |
+ | |R1 |
− | | |
||
− | |A |
||
|- bgcolor="#ffffff" |
|- bgcolor="#ffffff" |
||
! bgcolor="#d0e7ff" align="center" |GaAs |
! bgcolor="#d0e7ff" align="center" |GaAs |
||
| |
| |
||
+ | |[[RIE Etching Recipes|R4]] |
||
− | | |
||
− | |{{rl|RIE Etching Recipes|AlGaAs\GaAs Etching (RIE 5)}} |
||
| |
| |
||
| |
| |
||
|{{rl|ICP Etching Recipes|GaAs-AlGaAs Etch (Panasonic 1)}} |
|{{rl|ICP Etching Recipes|GaAs-AlGaAs Etch (Panasonic 1)}} |
||
− | | |
+ | |[[ICP Etching Recipes#GaAs Etch .28Panasonic 2.29|R3]] |
|[[ICP Etching Recipes#GaAs Etch .28Oxford ICP Etcher.29|R3]] |
|[[ICP Etching Recipes#GaAs Etch .28Oxford ICP Etcher.29|R3]] |
||
− | |{{rl|ICP Etching Recipes|ICP-Etch (Unaxis VLR)|GaAs-AlGaAs Etch (Unaxis VLR)|GaAs Etch (Unaxis VLR)}} |
||
| |
| |
||
| |
| |
||
Line 444: | Line 428: | ||
| |
| |
||
| |
| |
||
− | | |
+ | |R1 |
|- bgcolor="#eeffff" |
|- bgcolor="#eeffff" |
||
! bgcolor="#d0e7ff" align="center" |GaN |
! bgcolor="#d0e7ff" align="center" |GaN |
||
| |
| |
||
+ | |[[RIE Etching Recipes|R4]] |
||
− | | |
||
− | |{{rl|RIE Etching Recipes|GaN Etching (RIE 5)}} |
||
| |
| |
||
| |
| |
||
|{{rl|ICP Etching Recipes|GaN Etch (Panasonic 1)}} |
|{{rl|ICP Etching Recipes|GaN Etch (Panasonic 1)}} |
||
− | | |
+ | |R1 |
|[[ICP Etching Recipes#GaN Etch .28Oxford ICP Etcher.29|R2]] |
|[[ICP Etching Recipes#GaN Etch .28Oxford ICP Etcher.29|R2]] |
||
− | |{{rl|ICP Etching Recipes|GaN Etch (Unaxis VLR)}} |
||
| |
| |
||
| |
| |
||
Line 462: | Line 444: | ||
| |
| |
||
| |
| |
||
− | | |
+ | |R1 |
|- bgcolor="#ffffff" |
|- bgcolor="#ffffff" |
||
! bgcolor="#d0e7ff" align="center" |GaSb |
! bgcolor="#d0e7ff" align="center" |GaSb |
||
− | | |
||
| |
| |
||
| |
| |
||
Line 471: | Line 452: | ||
| |
| |
||
|A |
|A |
||
− | |A |
||
|R1 |
|R1 |
||
+ | |R1 |
||
− | |{{rl|ICP Etching Recipes|ICP-Etch (Unaxis VLR)|GaSb Etch Unaxis VLR)}} |
||
| |
| |
||
| |
| |
||
Line 480: | Line 460: | ||
| |
| |
||
| |
| |
||
− | | |
+ | |R1 |
|- bgcolor="#eeffff" |
|- bgcolor="#eeffff" |
||
! bgcolor="#d0e7ff" align="center" |HfO<sub>2</sub> |
! bgcolor="#d0e7ff" align="center" |HfO<sub>2</sub> |
||
Line 496: | Line 476: | ||
| |
| |
||
| |
| |
||
− | | |
+ | |R1 |
− | | |
||
− | |A |
||
|- bgcolor="#ffffff" |
|- bgcolor="#ffffff" |
||
! bgcolor="#d0e7ff" align="center" |InGaAlAs |
! bgcolor="#d0e7ff" align="center" |InGaAlAs |
||
− | | |
+ | |[[RIE Etching Recipes|R4]] |
− | | |
||
| |
| |
||
| |
| |
||
Line 509: | Line 486: | ||
| |
| |
||
|R1 |
|R1 |
||
− | |{{rl|ICP Etching Recipes|ICP-Etch (Unaxis VLR)|InP-InGaAs-InAlAs Etch (Unaxis VLR)|InP Etch (Unaxis VLR)}} |
||
| |
| |
||
| |
| |
||
Line 516: | Line 492: | ||
| |
| |
||
| |
| |
||
− | | |
+ | |R1 |
|- bgcolor="#eeffff" |
|- bgcolor="#eeffff" |
||
! bgcolor="#d0e7ff" align="center" |InGaAsP |
! bgcolor="#d0e7ff" align="center" |InGaAsP |
||
− | | |
+ | |[[RIE Etching Recipes|R4]] |
− | | |
||
| |
| |
||
| |
| |
||
Line 527: | Line 502: | ||
| |
| |
||
|[[ICP Etching Recipes#InP Ridge Etch .28Oxford ICP Etcher.29|R3]] |
|[[ICP Etching Recipes#InP Ridge Etch .28Oxford ICP Etcher.29|R3]] |
||
− | |{{rl|ICP Etching Recipes|ICP-Etch (Unaxis VLR)|InP-InGaAs-InAlAs Etch (Unaxis VLR)|InP Etch (Unaxis VLR)}} |
||
| |
| |
||
| |
| |
||
Line 534: | Line 508: | ||
| |
| |
||
| |
| |
||
− | | |
+ | |R1 |
|- bgcolor="#ffffff" |
|- bgcolor="#ffffff" |
||
! bgcolor="#d0e7ff" align="center" |InP |
! bgcolor="#d0e7ff" align="center" |InP |
||
− | | |
+ | |[[RIE Etching Recipes|R4]] |
− | | |
||
| |
| |
||
| |
| |
||
| |
| |
||
|A |
|A |
||
− | | |
+ | |R1 |
|[[ICP Etching Recipes#InP Ridge Etch .28Oxford ICP Etcher.29|R6]] |
|[[ICP Etching Recipes#InP Ridge Etch .28Oxford ICP Etcher.29|R6]] |
||
− | |{{rl|ICP Etching Recipes|ICP-Etch (Unaxis VLR)|InP-InGaAs-InAlAs Etch (Unaxis VLR)|InP Etch (Unaxis VLR)}} |
||
| |
| |
||
| |
| |
||
Line 552: | Line 524: | ||
| |
| |
||
| |
| |
||
− | | |
+ | |[[Other Dry Etching Recipes|R4]] |
|- bgcolor="#eeffff" |
|- bgcolor="#eeffff" |
||
! bgcolor="#d0e7ff" align="center" |ITO |
! bgcolor="#d0e7ff" align="center" |ITO |
||
− | | |
+ | |[[RIE Etching Recipes|R4]] |
| |
| |
||
| |
| |
||
Line 568: | Line 540: | ||
| |
| |
||
| |
| |
||
− | | |
+ | |R1 |
− | | |
||
− | |A |
||
|- |
|- |
||
!LiNbO3 |
!LiNbO3 |
||
Line 586: | Line 556: | ||
| |
| |
||
| |
| |
||
− | | |
+ | |R1 |
− | | |
||
− | |A |
||
|- bgcolor="#ffffff" |
|- bgcolor="#ffffff" |
||
− | !Photoresist |
+ | !Photoresist & Organics |
− | & ARC |
||
| |
| |
||
+ | |[[RIE Etching Recipes|R3]] |
||
− | |A |
||
− | |[https://wiki.nanotech.ucsb.edu/wiki/RIE_Etching_Recipes#Photoresist_and_ARC_.28RIE_5.29 R] |
||
| |
| |
||
+ | |[[ICP Etching Recipes#Photoresist .26 ARC .28Fluorine ICP Etcher.29|R3]] |
||
− | |[https://wiki.nanotech.ucsb.edu/wiki/ICP_Etching_Recipes#Photoresist_.26_ARC_.28Fluorine_ICP_Etcher.29 R4] |
||
|[https://wiki.nanotech.ucsb.edu/wiki/ICP_Etching_Recipes#Photoresist_and_ARC_Etching_.28Panasonic_1.29 R] |
|[https://wiki.nanotech.ucsb.edu/wiki/ICP_Etching_Recipes#Photoresist_and_ARC_Etching_.28Panasonic_1.29 R] |
||
+ | |[[ICP Etching Recipes#Al2O3 Etching .28Panasonic 2.29|R3]] |
||
− | |[https://wiki.nanotech.ucsb.edu/wiki/ICP_Etching_Recipes#Photoresist_and_ARC_etching_.28Panasonic_2.29 R] |
||
| |
| |
||
+ | |R3 |
||
+ | |[[Oxygen Plasma System Recipes#O2 Ashing|R3]] |
||
+ | |[[Oxygen Plasma System Recipes#O2 Ashing|R3]] |
||
| |
| |
||
− | |[[Oxygen Plasma System Recipes#O2 Ashing|R]] |
||
− | |[[Oxygen Plasma System Recipes#Plasma Clean .28YES EcoClean.29|R]] |
||
| |
| |
||
| |
| |
||
− | | |
+ | |R1 |
− | | |
||
− | |A |
||
|- |
|- |
||
+ | !ARC (Anti Reflective Coating) |
||
− | !Ru |
||
| |
| |
||
| |
| |
||
| |
| |
||
+ | |[[ICP Etching Recipes#Photoresist .26 ARC .28Fluorine ICP Etcher.29|R3]] |
||
| |
| |
||
− | | |
||
− | |A |
||
− | |[[ICP Etching Recipes#Ru .28Ruthenium.29 Etch .28Panasonic 2.29|R]] |
||
| |
| |
||
| |
| |
||
Line 628: | Line 591: | ||
|- bgcolor="#eeffff" |
|- bgcolor="#eeffff" |
||
! bgcolor="#d0e7ff" align="center" |SiC |
! bgcolor="#d0e7ff" align="center" |SiC |
||
− | | |
||
| |
| |
||
| |
| |
||
Line 634: | Line 596: | ||
| |
| |
||
|{{rl|ICP Etching Recipes|SiC Etch (Panasonic 1)}} |
|{{rl|ICP Etching Recipes|SiC Etch (Panasonic 1)}} |
||
− | | |
+ | |R1 |
| |
| |
||
| |
| |
||
Line 642: | Line 604: | ||
| |
| |
||
| |
| |
||
− | | |
+ | |R1 |
− | |A |
||
|- bgcolor="#ffffff" |
|- bgcolor="#ffffff" |
||
! bgcolor="#d0e7ff" align="center" |SiN |
! bgcolor="#d0e7ff" align="center" |SiN |
||
| |
| |
||
− | |{{rl|RIE Etching Recipes|RIE 3 (MRC)|SiN<sub>x</sub> Etching (RIE 3)}} |
||
| |
| |
||
| |
| |
||
− | |[[ICP Etching Recipes#Si3N4 Etching .28Fluorine ICP Etcher.29| |
+ | |[[ICP Etching Recipes#Si3N4 Etching .28Fluorine ICP Etcher.29|R3]] |
|{{rl|ICP Etching Recipes|SiNx Etching (Panasonic 1)}} |
|{{rl|ICP Etching Recipes|SiNx Etching (Panasonic 1)}} |
||
− | | |
+ | |[[ICP Etching Recipes#SiNx Etching .28Panasonic 2.29|R3]] |
| |
| |
||
+ | |[[Oxygen Plasma System Recipes#O2 Ashing|R3]] |
||
| |
| |
||
− | |A |
||
| |
| |
||
| |
| |
||
| |
| |
||
| |
| |
||
− | | |
+ | |R1 |
− | |A |
||
|- bgcolor="#eeffff" |
|- bgcolor="#eeffff" |
||
! bgcolor="#d0e7ff" align="center" |SiO<sub>2</sub> |
! bgcolor="#d0e7ff" align="center" |SiO<sub>2</sub> |
||
| |
| |
||
− | |{{rl|RIE Etching Recipes|RIE 3 (MRC)|SiO<sub>2</sub> Etching (RIE 3)}} |
||
| |
| |
||
| |
| |
||
|[[ICP Etching Recipes#SiO2 Etching .28Fluorine ICP Etcher.29|R6]] |
|[[ICP Etching Recipes#SiO2 Etching .28Fluorine ICP Etcher.29|R6]] |
||
|{{rl|ICP Etching Recipes|SiO2 Etching (Panasonic 1)}} |
|{{rl|ICP Etching Recipes|SiO2 Etching (Panasonic 1)}} |
||
− | | |
+ | |[[ICP Etching Recipes#SiO2 Etching .28Panasonic 2.29|R6]] |
| |
| |
||
| |
| |
||
Line 677: | Line 635: | ||
| |
| |
||
| |
| |
||
+ | |[[Other Dry Etching Recipes|R4]] |
||
− | | |
||
+ | |R1 |
||
− | |{{rl|Other Dry Etching Recipes|Other Dry Etch (Vapor HF Etcher)}} |
||
− | |A |
||
|- bgcolor="#ffffff" |
|- bgcolor="#ffffff" |
||
! bgcolor="#d0e7ff" align="center" |SiOxNy |
! bgcolor="#d0e7ff" align="center" |SiOxNy |
||
− | | |
||
| |
| |
||
| |
| |
||
Line 688: | Line 644: | ||
| |
| |
||
|A |
|A |
||
− | | |
+ | |R1 |
| |
| |
||
| |
| |
||
Line 696: | Line 652: | ||
| |
| |
||
| |
| |
||
− | | |
+ | |R1 |
− | |A |
||
|- |
|- |
||
!SU8 |
!SU8 |
||
− | | |
||
| |
| |
||
| |
| |
||
Line 706: | Line 660: | ||
| |
| |
||
|A |
|A |
||
− | | |
||
| |
| |
||
| |
| |
||
Line 718: | Line 671: | ||
|- bgcolor="#eeffff" |
|- bgcolor="#eeffff" |
||
! bgcolor="#d0e7ff" align="center" |Ta<sub>2</sub>O<sub>5</sub> |
! bgcolor="#d0e7ff" align="center" |Ta<sub>2</sub>O<sub>5</sub> |
||
− | | |
||
| |
| |
||
| |
| |
||
Line 724: | Line 676: | ||
| |
| |
||
|A |
|A |
||
+ | |R1 |
||
− | |[https://www.osapublishing.org/optica/abstract.cfm?uri=optica-4-5-532 A] |
||
| |
| |
||
| |
| |
||
Line 732: | Line 684: | ||
| |
| |
||
| |
| |
||
− | | |
+ | |R1 |
− | |A |
||
|- bgcolor="#ffffff" |
|- bgcolor="#ffffff" |
||
! bgcolor="#d0e7ff" align="center" |TiN |
! bgcolor="#d0e7ff" align="center" |TiN |
||
Line 749: | Line 700: | ||
| |
| |
||
| |
| |
||
− | | |
+ | |R1 |
− | | |
||
− | |A |
||
|- bgcolor="#eeffff" |
|- bgcolor="#eeffff" |
||
! bgcolor="#d0e7ff" align="center" |TiO<sub>2</sub> |
! bgcolor="#d0e7ff" align="center" |TiO<sub>2</sub> |
||
Line 767: | Line 716: | ||
| |
| |
||
| |
| |
||
− | | |
+ | |R1 |
− | | |
||
− | |A |
||
− | |- bgcolor="#ffffff" |
||
− | ! bgcolor="#d0e7ff" align="center" |W-TiW |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | |{{rl|ICP Etching Recipes|W-TiW Etch (Panasonic 1)}} |
||
− | |A |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | |A |
||
|- bgcolor="#eeffff" |
|- bgcolor="#eeffff" |
||
! bgcolor="#d0e7ff" align="center" |ZnO<sub>2</sub> |
! bgcolor="#d0e7ff" align="center" |ZnO<sub>2</sub> |
||
Line 803: | Line 732: | ||
| |
| |
||
| |
| |
||
− | | |
+ | |R1 |
− | | |
||
− | |A |
||
|- bgcolor="#ffffff" |
|- bgcolor="#ffffff" |
||
! bgcolor="#d0e7ff" align="center" |ZnS |
! bgcolor="#d0e7ff" align="center" |ZnS |
||
− | | |
+ | |[[RIE Etching Recipes|R3]] |
| |
| |
||
| |
| |
||
Line 821: | Line 748: | ||
| |
| |
||
| |
| |
||
− | | |
+ | |R1 |
− | | |
||
− | |A |
||
|- bgcolor="#eeffff" |
|- bgcolor="#eeffff" |
||
! bgcolor="#d0e7ff" align="center" |ZnSe |
! bgcolor="#d0e7ff" align="center" |ZnSe |
||
− | | |
+ | |[[RIE Etching Recipes|R2]] |
| |
| |
||
| |
| |
||
Line 839: | Line 764: | ||
| |
| |
||
| |
| |
||
− | | |
+ | |R1 |
− | | |
||
− | |A |
||
|- bgcolor="#ffffff" |
|- bgcolor="#ffffff" |
||
! bgcolor="#d0e7ff" align="center" |ZrO<sub>2</sub> |
! bgcolor="#d0e7ff" align="center" |ZrO<sub>2</sub> |
||
Line 857: | Line 780: | ||
| |
| |
||
| |
| |
||
− | | |
+ | |R1 |
− | | |
||
− | |A |
||
|- bgcolor="#eeffff" |
|- bgcolor="#eeffff" |
||
! bgcolor="#d0e7ff" align="center" |'''Material''' |
! bgcolor="#d0e7ff" align="center" |'''Material''' |
||
| bgcolor="#daf1ff" |[[RIE_Etching_Recipes#RIE_2_.28MRC.29|RIE 2<br> <span style="font-size: 88%;">(MRC)</span>]] |
| bgcolor="#daf1ff" |[[RIE_Etching_Recipes#RIE_2_.28MRC.29|RIE 2<br> <span style="font-size: 88%;">(MRC)</span>]] |
||
− | | bgcolor="#daf1ff" |[[RIE_Etching_Recipes#RIE_3_.28MRC.29|RIE 3<br> <span style="font-size: 88%;">(MRC)</span>]] |
||
| bgcolor="#daf1ff" |[[RIE_Etching_Recipes#RIE_5_.28PlasmaTherm.29|RIE 5<br><span style="font-size: 88%;">(PlasmaTherm)</span>]] |
| bgcolor="#daf1ff" |[[RIE_Etching_Recipes#RIE_5_.28PlasmaTherm.29|RIE 5<br><span style="font-size: 88%;">(PlasmaTherm)</span>]] |
||
| bgcolor="#daf1ff" |[[ICP_Etching_Recipes#DSEIII_.28PlasmaTherm.2FDeep_Silicon_Etcher.29|DSEIII<br><span style="font-size: 88%;">(PlasmaTherm)</span>]] |
| bgcolor="#daf1ff" |[[ICP_Etching_Recipes#DSEIII_.28PlasmaTherm.2FDeep_Silicon_Etcher.29|DSEIII<br><span style="font-size: 88%;">(PlasmaTherm)</span>]] |
||
Line 870: | Line 790: | ||
| bgcolor="#daf1ff" |[[ICP Etching Recipes#ICP Etch 2 .28Panasonic E626I.29|ICP Etch 2<br><span style="font-size: 88%;">(Panasonic E640)</span>]] |
| bgcolor="#daf1ff" |[[ICP Etching Recipes#ICP Etch 2 .28Panasonic E626I.29|ICP Etch 2<br><span style="font-size: 88%;">(Panasonic E640)</span>]] |
||
| bgcolor="#daf1ff" |[[ICP Etching Recipes#Oxford ICP Etcher .28PlasmaPro 100 Cobra.29|Oxford ICP <span style="font-size: 88%;">(PlasmaPro 100)</span>]] |
| bgcolor="#daf1ff" |[[ICP Etching Recipes#Oxford ICP Etcher .28PlasmaPro 100 Cobra.29|Oxford ICP <span style="font-size: 88%;">(PlasmaPro 100)</span>]] |
||
− | | bgcolor="#daf1ff" |[[ICP_Etching_Recipes#ICP-Etch_.28Unaxis_VLR.29|ICP-Etch<br><span style="font-size: 88%;">(Unaxis VLR)</span>]] |
||
| bgcolor="#daf1ff" |[[Oxygen_Plasma_System_Recipes#Ashers_.28Technics_PEII.29|Ashers<br><span style="font-size: 88%;">(Technics PEII)</span>]] |
| bgcolor="#daf1ff" |[[Oxygen_Plasma_System_Recipes#Ashers_.28Technics_PEII.29|Ashers<br><span style="font-size: 88%;">(Technics PEII)</span>]] |
||
| bgcolor="#daf1ff" |[[Oxygen Plasma System Recipes#Plasma Clean .28YES EcoClean.29|Plasma Clean <span style="font-size: 88%;">(YES EcoClean)</span>]] |
| bgcolor="#daf1ff" |[[Oxygen Plasma System Recipes#Plasma Clean .28YES EcoClean.29|Plasma Clean <span style="font-size: 88%;">(YES EcoClean)</span>]] |
Revision as of 11:06, 23 August 2024
Process Control Data
See above linked page for process control data (dep rate/stress etc. over time), for a selection of often-used dry etches
Dry Etching Tools/Materials Table
The Key/Legend for this table's A...R6
values is at the bottom of the page.
Process Ranking Table
Processes in the table above are ranked by their "Process Maturity Level" as follows:
Process Level | Description of Process Level Ranking | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
A | Process Allowed and materials available but never done | ||||||||||
R1 | Process has been run at least once | ||||||||||
R2 | Process has been run and/or procedure is documented or/and data available | ||||||||||
R3 | Process has been run, procedure is documented, and data is available | ||||||||||
R4 | Process has a documented procedure with regular (≥4x per year) data or lookahead/in-situ control available | ||||||||||
R5 | Process has a documented procedure with regular (≥4x per year) data and lookahead/in-situ control available | ||||||||||
R6 | Process has a documented procedure, regular ( ≥4x per year) data, and control charts & limits available |