Holographic Lith/PL Setup (Custom): Difference between revisions

From UCSB Nanofab Wiki
Jump to navigation Jump to search
m (→‎About: added term "holography" for searching, changed PR to THMR and linked)
mNo edit summary
 
(7 intermediate revisions by the same user not shown)
Line 1: Line 1:
{{tool|{{PAGENAME}}
{{tool2|{{PAGENAME}}
|picture=Holograph.jpg
|picture=Holograph.jpg
|type = Lithography
|type = Lithography
|super= Ning Cao
|super= Demis D. John
|super2 = Brian Thibeault
|phone=(805) 839-5689
|location=Bay 6
|location=Bay 6
|description = Custom Interference Lithography
|email=Ningcao@ece.ucsb.edu
|description = Custom Built Interference Lithography
|manufacturer = Custom-Built Free-Space Optics
|manufacturer = Kimmon
|toolid=35
|toolid=35
}}
}}
= About =
==About==
===Holography Lithography===
The interference lithography system (aka. Holography) at UCSB uses a 15mW, single-mode, 325 nm HeCd laser that is filtered and expanded by pinhole filters to produce the large area exposure beam. The system uses a simple mirror configuration with a fixed 90 degree angle between the mirror and sample. The entire mirror/sample assembly is rotated in 0.1 degree increments to change the grating pitch from ~ 200 nm to ~ 280 nm (35 to 55 degrees) over an ~ 2 cm x 2 cm exposure area.
The interference lithography system (aka. Holography) at UCSB uses a 15mW, single-mode, 325 nm HeCd laser that is filtered and expanded by pinhole filters to produce the large area exposure beam. The system uses a simple mirror configuration with a fixed 90 degree angle between the mirror and sample. The entire mirror/sample assembly is rotated in 0.1 degree increments to change the grating pitch from ~ 200 nm to ~ 280 nm (35 to 55 degrees) over an ~ 2 cm x 2 cm exposure area.


[[Lithography Recipes#Chemicals Stocked .2B Datasheets|THMR-3600HP]] resist spin-coated to ~ 80 nm thickness is used for grating exposure. 2-D gratings can be formed by rotating the sample and doing multiple exposures. Total exposure times are controlled by a manual shutter and are generally several minutes in length.
[https://wiki.nanofab.ucsb.edu/w/images/3/33/XHRiC-Anti-Reflective-Coating.pdf XHRiC] bottom anti-reflection coating (BARC) & [[Lithography Recipes#Chemicals Stocked .2B Datasheets|THMR-3600HP]] imaging resist spin-coated to ~80 nm thickness is used for grating exposure. 2-D gratings can be formed by rotating the sample and doing multiple exposures. Total exposure times are controlled by a manual shutter and are generally several minutes in length.


===Photoluminescence Measurement===
=Detailed Specifications=
A photoluminescence measurement setup is co-located on the optical table. Please see the page for the PL system for more info:
*15 mW single TEM mode HeCd laser

*~ 2 cm x 2 cm uniform exposure area
*[[Photoluminescence PL Setup (Custom)|'''Photoluminescence PL Setup (Custom)''']]
*~ several minute exposure times

*Grating period adjustable from ~200 to ~280 nm with a single stage
==Detailed Specifications==

*15 mW single TEM mode HeCd laser (Kimmon)
*Max sample size: ~1.5 inch square uniform exposure area
*~2 cm x 2 cm uniform exposure area
*Several-minute exposure times (manual shutter)
*Grating period adjustable from ~200 to ~280 nm with rotation stage
*Manual optics alignment.
*1-D and 2-D gratings possible, see recipes below.

==Recipes==

*[[Lithography Recipes#Holography%20Recipes|Lithography Recipes > Holography Recipes]] - developed recipes for 1D (line/space) and 2D (pillars) gratings.

Latest revision as of 23:54, 5 February 2025

Holographic Lith/PL Setup (Custom)
Holograph.jpg
Location Bay 6
Tool Type Lithography
Manufacturer Custom-Built Free-Space Optics
Description Custom Interference Lithography

Primary Supervisor Demis D. John
(805) 893-5934
demis@ucsb.edu

Secondary Supervisor

Brian Thibeault


Recipes

SignupMonkey: Sign up for this tool


About

Holography Lithography

The interference lithography system (aka. Holography) at UCSB uses a 15mW, single-mode, 325 nm HeCd laser that is filtered and expanded by pinhole filters to produce the large area exposure beam. The system uses a simple mirror configuration with a fixed 90 degree angle between the mirror and sample. The entire mirror/sample assembly is rotated in 0.1 degree increments to change the grating pitch from ~ 200 nm to ~ 280 nm (35 to 55 degrees) over an ~ 2 cm x 2 cm exposure area.

XHRiC bottom anti-reflection coating (BARC) & THMR-3600HP imaging resist spin-coated to ~80 nm thickness is used for grating exposure. 2-D gratings can be formed by rotating the sample and doing multiple exposures. Total exposure times are controlled by a manual shutter and are generally several minutes in length.

Photoluminescence Measurement

A photoluminescence measurement setup is co-located on the optical table. Please see the page for the PL system for more info:

Detailed Specifications

  • 15 mW single TEM mode HeCd laser (Kimmon)
  • Max sample size: ~1.5 inch square uniform exposure area
  • ~2 cm x 2 cm uniform exposure area
  • Several-minute exposure times (manual shutter)
  • Grating period adjustable from ~200 to ~280 nm with rotation stage
  • Manual optics alignment.
  • 1-D and 2-D gratings possible, see recipes below.

Recipes