Dry Etching Recipes: Difference between revisions
Jump to navigation
Jump to search
Content deleted Content added
Oxford links to GaN+GaAs recipes |
updated FL-ICP Si + SIO2 link cuz changed header title |
||
| (63 intermediate revisions by 4 users not shown) | |||
| Line 1: | Line 1: | ||
===<u>[[Process Group - Process Control Data#Etching .28Process Control Data.29|Process Control Data]]</u>=== |
|||
{{Recipe Table Explanation}} |
|||
<small>''See above [[Process Group - Process Control Data#Etching .28Process Control Data.29|linked page]] for [https://en.wikipedia.org/wiki/Statistical_process_control process control data] (dep rate/stress etc. over time), for a selection of often-used dry etches''</small> |
|||
===Dry Etching Tools/Materials Table=== |
|||
''The Key/Legend for this table's <code>A...R6</code> values is at the [[Dry Etching Recipes#Process Ranking Table|bottom of the page]].'' |
|||
{| class="wikitable" style="border: 1px solid #D0E7FF; background-color:#ffffff; text-align:center; font-size: 95%" border="1" |
{| class="wikitable" style="border: 1px solid #D0E7FF; background-color:#ffffff; text-align:center; font-size: 95%" border="1" |
||
|- |
|||
! colspan="15" width="725" height="45" |<div style="font-size: 150%;">Dry Etching Recipes</div> |
|||
|- bgcolor="#d0e7ff" |
|- bgcolor="#d0e7ff" |
||
| bgcolor="#eaecf0" |<!-- INTENTIONALLY LEFT BLANK --> |
|||
! colspan="18" width="725" height="45" |<div style="font-size: 150%;">Dry Etching Recipes</div> |
|||
! colspan="2" |'''[[RIE Etching Recipes|RIE Etching]]''' |
|||
! colspan="5" |'''[[ICP Etching Recipes|ICP Etching]]''' |
|||
! colspan="4" bgcolor="#d0e7ff" align="center" |'''[[Oxygen Plasma System Recipes|Oxygen Plasma Systems]]''' |
|||
! colspan="3" bgcolor="#d0e7ff" align="center" |'''[[Other Dry Etching Recipes|Other Dry Etchers]]''' |
|||
|- bgcolor="#d0e7ff" |
|- bgcolor="#d0e7ff" |
||
|<!-- INTENTIONALLY LEFT BLANK --> |
|||
! colspan="3" |'''[[RIE Etching Recipes|RIE Etching]]''' |
|||
! colspan="6" |'''[[ICP Etching Recipes|ICP Etching]]''' |
|||
! colspan="5" bgcolor="#d0e7ff" align="center" |'''[[Oxygen Plasma System Recipes|Oxygen Plasma Systems]]''' |
|||
! colspan="3" bgcolor="#d0e7ff" align="center" |'''[[Other Dry Etching Recipes|Other Dry Etchers]]''' |
|||
|- |
|||
! bgcolor="#d0e7ff" align="center" |'''Material''' |
! bgcolor="#d0e7ff" align="center" |'''Material''' |
||
| bgcolor="#daf1ff" |[[RIE_Etching_Recipes#RIE_2_.28MRC.29|RIE 2<br> <span style="font-size: 88%;">(MRC)</span>]] |
| bgcolor="#daf1ff" |[[RIE_Etching_Recipes#RIE_2_.28MRC.29|RIE 2<br> <span style="font-size: 88%;">(MRC)</span>]] |
||
| bgcolor="#daf1ff" |[[RIE_Etching_Recipes#RIE_3_.28MRC.29|RIE 3<br> <span style="font-size: 88%;">(MRC)</span>]] |
|||
| bgcolor="#daf1ff" |[[RIE_Etching_Recipes#RIE_5_.28PlasmaTherm.29|RIE 5<br><span style="font-size: 88%;">(PlasmaTherm)</span>]] |
| bgcolor="#daf1ff" |[[RIE_Etching_Recipes#RIE_5_.28PlasmaTherm.29|RIE 5<br><span style="font-size: 88%;">(PlasmaTherm)</span>]] |
||
| bgcolor="#daf1ff" |[[ICP_Etching_Recipes#DSEIII_.28PlasmaTherm.2FDeep_Silicon_Etcher.29|DSEIII<br><span style="font-size: 88%;">(PlasmaTherm)</span>]] |
| bgcolor="#daf1ff" |[[ICP_Etching_Recipes#DSEIII_.28PlasmaTherm.2FDeep_Silicon_Etcher.29|DSEIII<br><span style="font-size: 88%;">(PlasmaTherm)</span>]] |
||
| bgcolor="#daf1ff" |[[ICP Etching Recipes#PlasmaTherm.2FSLR Fluorine Etcher|Fluorine ICP <span style="font-size: 88%;">(PlasmaTherm)</span>]] |
| bgcolor="#daf1ff" |[[ICP Etching Recipes#PlasmaTherm.2FSLR Fluorine Etcher|Fluorine ICP <span style="font-size: 88%;">(PlasmaTherm)</span>]] |
||
| bgcolor="#daf1ff" |[[ |
| bgcolor="#daf1ff" |[[ICP Etching Recipes#ICP Etch 1 .28Panasonic E646V.29|ICP Etch 1<br><span style="font-size: 88%;">(Panasonic E646V)</span>]] |
||
| bgcolor="#daf1ff" |[[ |
| bgcolor="#daf1ff" |[[ICP Etching Recipes#ICP Etch 2 .28Panasonic E626I.29|ICP Etch 2<br><span style="font-size: 88%;">(Panasonic E626I)</span>]] |
||
| bgcolor="#daf1ff" |[[ICP Etching Recipes#Oxford ICP Etcher .28PlasmaPro 100 Cobra.29|Oxford ICP <span style="font-size: 88%;">(PlasmaPro 100)</span>]] |
| bgcolor="#daf1ff" |[[ICP Etching Recipes#Oxford ICP Etcher .28PlasmaPro 100 Cobra.29|Oxford ICP <span style="font-size: 88%;">(PlasmaPro 100)</span>]] |
||
| bgcolor="#daf1ff" |[[ICP_Etching_Recipes#ICP-Etch_.28Unaxis_VLR.29|ICP-Etch<br><span style="font-size: 88%;">(Unaxis VLR)</span>]] |
|||
| bgcolor="#daf1ff" |[[Oxygen_Plasma_System_Recipes#Ashers_.28Technics_PEII.29|Ashers<br><span style="font-size: 88%;">(Technics PEII)</span>]] |
| bgcolor="#daf1ff" |[[Oxygen_Plasma_System_Recipes#Ashers_.28Technics_PEII.29|Ashers<br><span style="font-size: 88%;">(Technics PEII)</span>]] |
||
| bgcolor="#daf1ff" |[[Oxygen_Plasma_System_Recipes#Plasma_Clean_.28Gasonics_2000.29|Plasma Clean<br><span style="font-size: 88%;">(Gasonics 2000)</span>]] |
|||
| bgcolor="#daf1ff" |[[Oxygen Plasma System Recipes#Plasma Clean .28YES EcoClean.29|Plasma Clean <span style="font-size: 88%;">(YES EcoClean)</span>]] |
| bgcolor="#daf1ff" |[[Oxygen Plasma System Recipes#Plasma Clean .28YES EcoClean.29|Plasma Clean <span style="font-size: 88%;">(YES EcoClean)</span>]] |
||
| bgcolor="#daf1ff" |[[Oxygen_Plasma_System_Recipes#UV_Ozone_Reactor|UV Ozone Reactor]] |
| bgcolor="#daf1ff" |[[Oxygen_Plasma_System_Recipes#UV_Ozone_Reactor|UV Ozone Reactor]] |
||
| Line 44: | Line 44: | ||
| |
| |
||
| |
| |
||
| |
|R1 |
||
| |
|||
| |
|||
|A |
|||
|- bgcolor="#ffffff" |
|- bgcolor="#ffffff" |
||
! bgcolor="#d0e7ff" align="center" |Al |
! bgcolor="#d0e7ff" align="center" |Al |
||
| |
| |
||
|[[RIE Etching Recipes|R2]] |
|||
| |
| |
||
|[[RIE Etching Recipes|A]] |
|||
| |
| |
||
|{{rl|ICP Etching Recipes|Al Etch (Panasonic 1)|R1}} |
|||
|[[ICP Etching Recipes#Al Etch .28Panasonic 2.29|R2]] |
|||
| |
| |
||
|{{rl|ICP Etching Recipes|Al Etch (Panasonic 1)}} |
|||
|{{rl|ICP Etching Recipes|Al Etch (Panasonic 2)}} |
|||
| |
| |
||
| |
| |
||
| Line 63: | Line 60: | ||
| |
| |
||
| |
| |
||
| |
|R1 |
||
| |
|||
| |
|||
|A |
|||
|- bgcolor="#eeffff" |
|- bgcolor="#eeffff" |
||
! bgcolor="#d0e7ff" align="center" |Au |
! bgcolor="#d0e7ff" align="center" |Au |
||
| Line 82: | Line 76: | ||
| |
| |
||
| |
| |
||
|[[Other Dry Etching Recipes|R4]] |
|||
| |
|||
| |
|||
| |
|||
|{{rl|Other Dry Etching Recipes|Other Dry Etch (CAIBE (Oxford Ion Mill))}} |
|||
|- bgcolor="#ffffff" |
|- bgcolor="#ffffff" |
||
! bgcolor="#d0e7ff" align="center" |Cr |
! bgcolor="#d0e7ff" align="center" |Cr |
||
| |
| |
||
|[[RIE Etching Recipes|R2]] |
|||
| |
|||
|A |
|||
| |
| |
||
| |
| |
||
|{{rl|ICP Etching Recipes|Cr Etch (Panasonic 1)}} |
|{{rl|ICP Etching Recipes|Cr Etch (Panasonic 1)}} |
||
| |
|R1 |
||
| |
| |
||
| |
| |
||
| Line 102: | Line 92: | ||
| |
| |
||
| |
| |
||
| |
|R1 |
||
| |
|||
|A |
|||
|- bgcolor="#eeffff" |
|- bgcolor="#eeffff" |
||
! bgcolor="#d0e7ff" align="center" |Cu |
! bgcolor="#d0e7ff" align="center" |Cu |
||
| Line 119: | Line 107: | ||
| |
| |
||
| |
| |
||
| |
|||
|R1 |
|||
|- bgcolor="#ffffff" |
|||
! bgcolor="#d0e7ff" align="center" |Ge |
|||
| |
| |
||
| |
| |
||
| Line 124: | Line 116: | ||
| |
| |
||
|A |
|A |
||
|R1 |
|||
|- bgcolor="#ffffff" |
|||
! bgcolor="#d0e7ff" align="center" |Ge |
|||
| |
| |
||
| |
| |
||
| Line 131: | Line 122: | ||
| |
| |
||
| |
| |
||
|[[Other Dry Etching Recipes|R2]] |
|||
| |
| |
||
|R1 |
|||
|- bgcolor="#eeffff" |
|||
! bgcolor="#d0e7ff" align="center" |Mo |
|||
| |
| |
||
| |
| |
||
| Line 140: | Line 135: | ||
| |
| |
||
| |
| |
||
|A |
|||
| |
| |
||
|A |
|||
|- bgcolor="#eeffff" |
|||
! bgcolor="#d0e7ff" align="center" |Mo |
|||
| |
| |
||
| |
| |
||
| |
| |
||
| |
| |
||
|R1 |
|||
|- |
|||
!Nb |
|||
| |
| |
||
| |
| |
||
| |
| |
||
| |
| |
||
|A |
|||
|R1 |
|||
| |
| |
||
| |
| |
||
| Line 161: | Line 157: | ||
| |
| |
||
| |
| |
||
|A |
|||
|- bgcolor="#ffffff" |
|- bgcolor="#ffffff" |
||
! bgcolor="#d0e7ff" align="center" |Ni |
! bgcolor="#d0e7ff" align="center" |Ni |
||
| Line 177: | Line 172: | ||
| |
| |
||
| |
| |
||
|[[Other Dry Etching Recipes|R4]] |
|||
|- |
|||
!Os |
|||
| |
| |
||
| |
| |
||
| |
| |
||
|{{rl|Other Dry Etching Recipes|Other Dry Etch (CAIBE (Oxford Ion Mill))}} |
|||
|- bgcolor="#eeffff" |
|||
! bgcolor="#d0e7ff" align="center" |Pt |
|||
| |
| |
||
|A |
|||
|R1 |
|||
| |
| |
||
| |
| |
||
| |
| |
||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|- bgcolor="#eeffff" |
|||
! bgcolor="#d0e7ff" align="center" |Pt |
|||
| |
| |
||
| |
| |
||
| Line 199: | Line 203: | ||
| |
| |
||
| |
| |
||
| |
|||
|{{rl|Other Dry Etching Recipes|Other Dry Etch (CAIBE (Oxford Ion Mill))}} |
|||
|[[Other Dry Etching Recipes|R4]] |
|||
|- bgcolor="#ffffff" |
|- bgcolor="#ffffff" |
||
! bgcolor="#d0e7ff" align="center" |Ru |
! bgcolor="#d0e7ff" align="center" |Ru |
||
| |
|||
| |
| |
||
| |
| |
||
| Line 208: | Line 212: | ||
| |
| |
||
|A |
|A |
||
| |
|[[ICP Etching Recipes#Ru .28Ruthenium.29 Etch .28Panasonic 2.29|R3]] |
||
| |
| |
||
| |
| |
||
| Line 216: | Line 220: | ||
| |
| |
||
| |
| |
||
| |
|R1 |
||
| |
|||
|A |
|||
|- bgcolor="#eeffff" |
|- bgcolor="#eeffff" |
||
! bgcolor="#d0e7ff" align="center" |Si |
! bgcolor="#d0e7ff" align="center" |Si |
||
| |
| |
||
| |
| |
||
|[[ICP Etching Recipes#DSEIII .28PlasmaTherm.2FDeep Silicon Etcher.29|R6]] |
|||
|[[ICP Etching Recipes#Si Etch Recipes (Fluorine ICP Etcher)|R6]] |
|||
| |
| |
||
|{{rl|ICP Etching Recipes|DSEIII_(PlasmaTherm/Deep_Silicon_Etcher)}} |
|||
|{{Rl|ICP Etching Recipes|Si Etching}} |
|||
| |
| |
||
|R1 |
|||
| |
| |
||
|A |
|||
| |
| |
||
| |
| |
||
| |
| |
||
|[[Other Dry Etching Recipes|R4]] |
|||
| |
|||
|R1 |
|||
|- bgcolor="#ffffff" |
|||
! bgcolor="#d0e7ff" align="center" |Ta |
|||
| |
| |
||
| |
| |
||
| |
| |
||
|{{rl|Other Dry Etching Recipes|Other Dry Etch (XeF2 Etcher)}} |
|||
| |
| |
||
|A |
|A |
||
|R1 |
|||
|- bgcolor="#ffffff" |
|||
! bgcolor="#d0e7ff" align="center" |Ta |
|||
| |
| |
||
| |
| |
||
| Line 247: | Line 252: | ||
| |
| |
||
| |
| |
||
|R1 |
|||
|- bgcolor="#eeffff" |
|||
! bgcolor="#d0e7ff" align="center" |Ti |
|||
| |
| |
||
| |
| |
||
| |
| |
||
| |
| |
||
|{{rl|ICP Etching Recipes|Ti Etch (Panasonic 1)}} |
|||
|R1 |
|||
| |
| |
||
| |
| |
||
| Line 256: | Line 266: | ||
| |
| |
||
| |
| |
||
|A |
|||
|- bgcolor="#eeffff" |
|||
! bgcolor="#d0e7ff" align="center" |Ti |
|||
| |
| |
||
| |
| |
||
|R1 |
|||
|- bgcolor="#ffffff" |
|||
! bgcolor="#d0e7ff" align="center" |W |
|||
| |
| |
||
| |
| |
||
| |
| |
||
|R2 |
|||
|{{rl|ICP Etching Recipes|Ti Etch (Panasonic 1)}} |
|||
|{{rl|ICP Etching Recipes|W-TiW Etch (Panasonic 1)}} |
|||
|A |
|||
|R1 |
|||
| |
| |
||
| |
| |
||
| Line 273: | Line 284: | ||
| |
| |
||
| |
| |
||
|R1 |
|||
|- |
|||
!TiW |
|||
| |
| |
||
| |
| |
||
|A |
|||
|- bgcolor="#ffffff" |
|||
! bgcolor="#d0e7ff" align="center" |Al<sub>2</sub>O<sub>3</sub> |
|||
| |
| |
||
|R2 |
|||
| |
| |
||
|R1 |
|||
| |
| |
||
| |
| |
||
| |
| |
||
| |
|||
|[https://wiki.nanotech.ucsb.edu/w/index.php?title=ICP_Etching_Recipes#Al2O3_Etching_.28Panasonic_2.29 R] |
|||
| |
| |
||
| |
| |
||
| Line 290: | Line 301: | ||
| |
| |
||
| |
| |
||
|- bgcolor="#ffffff" |
|||
! bgcolor="#d0e7ff" align="center" |Al<sub>2</sub>O<sub>3</sub> |
|||
| |
| |
||
| |
| |
||
| Line 295: | Line 308: | ||
| |
| |
||
|A |
|A |
||
|[[ICP Etching Recipes#Al2O3 Etching .28Panasonic 2.29|R3]] |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|R1 |
|||
|- bgcolor="#eeffff" |
|- bgcolor="#eeffff" |
||
! bgcolor="#d0e7ff" align="center" |Al<sub>2</sub>O<sub>3 (Sapphire)</sub> |
! bgcolor="#d0e7ff" align="center" |Al<sub>2</sub>O<sub>3 (Sapphire)</sub> |
||
| |
|||
| |
| |
||
| |
| |
||
| Line 303: | Line 324: | ||
| |
| |
||
|{{rl|ICP Etching Recipes|Sapphire Etch (Panasonic 1)}} |
|{{rl|ICP Etching Recipes|Sapphire Etch (Panasonic 1)}} |
||
| |
|R1 |
||
| |
| |
||
| |
| |
||
| Line 311: | Line 332: | ||
| |
| |
||
| |
| |
||
| |
|R1 |
||
| |
|||
|A |
|||
|- bgcolor="#ffffff" |
|- bgcolor="#ffffff" |
||
! bgcolor="#d0e7ff" align="center" |AlGaAs |
! bgcolor="#d0e7ff" align="center" |AlGaAs |
||
| |
| |
||
|[[RIE Etching Recipes|R3]] |
|||
| |
| |
||
|{{rl|RIE Etching Recipes|AlGaAs\GaAs Etching (RIE 5)}} |
|||
| |
| |
||
|{{rl|ICP Etching Recipes|GaAs-AlGaAs Etch (Panasonic 1)}} |
|||
| |
| |
||
| |
|[[ICP Etching Recipes#GaAs Etch .28Oxford ICP Etcher.29|R3]] |
||
| |
| |
||
|[[ICP Etching Recipes#GaAs Etch .28Oxford ICP Etcher.29|R]] |
|||
|{{rl|ICP Etching Recipes|ICP-Etch (Unaxis VLR)|GaAs-AlGaAs Etch (Unaxis VLR)|AlGaAs Etch (Unaxis VLR)}} |
|||
| |
| |
||
| |
| |
||
| Line 330: | Line 348: | ||
| |
| |
||
| |
| |
||
| |
|R1 |
||
| |
|||
|A |
|||
|- bgcolor="#eeffff" |
|- bgcolor="#eeffff" |
||
! bgcolor="#d0e7ff" align="center" |AlGaN |
! bgcolor="#d0e7ff" align="center" |AlGaN |
||
| Line 341: | Line 357: | ||
| |
| |
||
| |
| |
||
|[[ICP Etching Recipes#GaN Etch .28Oxford ICP Etcher.29|R2]] |
|||
| |
| |
||
|[[ICP Etching Recipes#GaN Etch .28Oxford ICP Etcher.29|R]] |
|||
|{{rl|ICP Etching Recipes|GaN Etch (Unaxis VLR)}} |
|||
| |
| |
||
| |
| |
||
| Line 349: | Line 364: | ||
| |
| |
||
| |
| |
||
| |
|R1 |
||
| |
|||
|A |
|||
|- bgcolor="#ffffff" |
|- bgcolor="#ffffff" |
||
! bgcolor="#d0e7ff" align="center" |AlN |
! bgcolor="#d0e7ff" align="center" |AlN |
||
| Line 362: | Line 375: | ||
| |
| |
||
| |
| |
||
|{{rl|ICP Etching Recipes|GaN Etch (Unaxis VLR)}} |
|||
| |
| |
||
| |
| |
||
| |
| |
||
| |
|||
| |
|||
|R1 |
|||
|- |
|||
!BCB |
|||
| |
| |
||
| |
| |
||
| Line 371: | Line 388: | ||
| |
| |
||
|A |
|A |
||
|- bgcolor="#eeffff" |
|||
! bgcolor="#d0e7ff" align="center" |CdZnTe |
|||
|{{rl|RIE Etching Recipes|CdZnTe Etch (RIE 2)}} |
|||
| |
| |
||
| |
| |
||
| Line 383: | Line 397: | ||
| |
| |
||
| |
| |
||
|- bgcolor="#eeffff" |
|||
! bgcolor="#d0e7ff" align="center" |CdZnTe |
|||
|[[RIE Etching Recipes|R3]] |
|||
| |
| |
||
| |
| |
||
| Line 389: | Line 406: | ||
| |
| |
||
| |
| |
||
| |
| |
||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|R1 |
|||
|- bgcolor="#ffffff" |
|- bgcolor="#ffffff" |
||
! bgcolor="#d0e7ff" align="center" |GaAs |
! bgcolor="#d0e7ff" align="center" |GaAs |
||
| |
| |
||
|[[RIE Etching Recipes|R4]] |
|||
| |
| |
||
|{{rl|RIE Etching Recipes|AlGaAs\GaAs Etching (RIE 5)}} |
|||
| |
| |
||
|{{rl|ICP Etching Recipes|GaAs-AlGaAs Etch (Panasonic 1)}} |
|||
|[[ICP Etching Recipes#GaAs Etch .28Panasonic 2.29|R6]] |
|||
|[[ICP Etching Recipes#GaAs Etch .28Oxford ICP Etcher.29|R2]] |
|||
| |
| |
||
|{{rl|ICP Etching Recipes|GaAs-AlGaAs_Etch_.28Panasonic_1.29}} |
|||
|{{rl|ICP Etching Recipes|GaAs Etch (Panasonic 2)}} |
|||
|[[ICP Etching Recipes#GaAs Etch .28Oxford ICP Etcher.29|R]] |
|||
|{{rl|ICP Etching Recipes|ICP-Etch (Unaxis VLR)|GaAs-AlGaAs Etch (Unaxis VLR)|GaAs Etch (Unaxis VLR)}} |
|||
| |
| |
||
| |
| |
||
| Line 406: | Line 428: | ||
| |
| |
||
| |
| |
||
| |
|R1 |
||
| |
|||
|A |
|||
|- bgcolor="#eeffff" |
|- bgcolor="#eeffff" |
||
! bgcolor="#d0e7ff" align="center" |GaN |
! bgcolor="#d0e7ff" align="center" |GaN |
||
| |
| |
||
|[[RIE Etching Recipes|R4]] |
|||
| |
|||
|{{rl|RIE Etching Recipes|GaN Etching (RIE 5)}} |
|||
| |
| |
||
| |
| |
||
|{{rl|ICP Etching Recipes|GaN Etch (Panasonic 1)}} |
|{{rl|ICP Etching Recipes|GaN Etch (Panasonic 1)}} |
||
|R1 |
|||
|[[ICP Etching Recipes#GaN Etch .28Oxford ICP Etcher.29|R6]] |
|||
| |
| |
||
|[[ICP Etching Recipes#GaN Etch .28Oxford ICP Etcher.29|R]] |
|||
|{{rl|ICP Etching Recipes|GaN Etch (Unaxis VLR)}} |
|||
| |
| |
||
| |
| |
||
| Line 425: | Line 444: | ||
| |
| |
||
| |
| |
||
| |
|R1 |
||
| |
|||
|A |
|||
|- bgcolor="#ffffff" |
|- bgcolor="#ffffff" |
||
! bgcolor="#d0e7ff" align="center" |GaSb |
! bgcolor="#d0e7ff" align="center" |GaSb |
||
| |
|||
| |
|||
| |
| |
||
| |
| |
||
| Line 437: | Line 452: | ||
| |
| |
||
|A |
|A |
||
|R1 |
|||
|R1 |
|||
| |
| |
||
|{{rl|ICP Etching Recipes|ICP-Etch (Unaxis VLR)|GaSb Etch Unaxis VLR)}} |
|||
| |
| |
||
| |
| |
||
| Line 444: | Line 460: | ||
| |
| |
||
| |
| |
||
| |
|R1 |
||
| |
|||
|A |
|||
|- bgcolor="#eeffff" |
|- bgcolor="#eeffff" |
||
! bgcolor="#d0e7ff" align="center" |HfO<sub>2</sub> |
! bgcolor="#d0e7ff" align="center" |HfO<sub>2</sub> |
||
| Line 462: | Line 476: | ||
| |
| |
||
| |
| |
||
| |
|R1 |
||
| |
|||
| |
|||
|A |
|||
|- bgcolor="#ffffff" |
|- bgcolor="#ffffff" |
||
! bgcolor="#d0e7ff" align="center" |InGaAlAs |
! bgcolor="#d0e7ff" align="center" |InGaAlAs |
||
| |
|[[RIE Etching Recipes|R4]] |
||
| |
| |
||
| |
| |
||
| Line 474: | Line 485: | ||
| |
| |
||
| |
| |
||
|R1 |
|||
| |
| |
||
|A |
|||
|{{rl|ICP Etching Recipes|ICP-Etch (Unaxis VLR)|InP-InGaAs-InAlAs Etch (Unaxis VLR)|InP Etch (Unaxis VLR)}} |
|||
| |
| |
||
| |
| |
||
| Line 482: | Line 492: | ||
| |
| |
||
| |
| |
||
| |
|R1 |
||
| |
|||
|A |
|||
|- bgcolor="#eeffff" |
|- bgcolor="#eeffff" |
||
! bgcolor="#d0e7ff" align="center" |InGaAsP |
! bgcolor="#d0e7ff" align="center" |InGaAsP |
||
| |
|[[RIE Etching Recipes|R4]] |
||
| |
| |
||
| |
| |
||
| Line 493: | Line 501: | ||
| |
| |
||
| |
| |
||
|[[ICP Etching Recipes#InP Ridge Etch .28Oxford ICP Etcher.29|R3]] |
|||
| |
| |
||
|[[ICP Etching Recipes#InP Ridge Etch .28Oxford ICP Etcher.29|R]] |
|||
|{{rl|ICP Etching Recipes|ICP-Etch (Unaxis VLR)|InP-InGaAs-InAlAs Etch (Unaxis VLR)|InP Etch (Unaxis VLR)}} |
|||
| |
| |
||
| |
| |
||
| Line 501: | Line 508: | ||
| |
| |
||
| |
| |
||
| |
|R1 |
||
| |
|||
|A |
|||
|- bgcolor="#ffffff" |
|- bgcolor="#ffffff" |
||
! bgcolor="#d0e7ff" align="center" |InP |
! bgcolor="#d0e7ff" align="center" |InP |
||
| |
|[[RIE Etching Recipes|R4]] |
||
| |
|||
| |
| |
||
| |
| |
||
| |
| |
||
|A |
|A |
||
| |
|R1 |
||
|[[ICP Etching Recipes#InP Ridge Etch .28Oxford ICP Etcher.29| |
|[[ICP Etching Recipes#InP Ridge Etch .28Oxford ICP Etcher.29|R6]] |
||
|{{rl|ICP Etching Recipes|ICP-Etch (Unaxis VLR)|InP-InGaAs-InAlAs Etch (Unaxis VLR)|InP Etch (Unaxis VLR)}} |
|||
| |
|||
| |
| |
||
| |
| |
||
| Line 522: | Line 524: | ||
| |
| |
||
| |
| |
||
| |
|[[Other Dry Etching Recipes|R4]] |
||
|- bgcolor="#eeffff" |
|- bgcolor="#eeffff" |
||
! bgcolor="#d0e7ff" align="center" |ITO |
! bgcolor="#d0e7ff" align="center" |ITO |
||
| |
|[[RIE Etching Recipes|R4]] |
||
| |
| |
||
| |
| |
||
| Line 538: | Line 540: | ||
| |
| |
||
| |
| |
||
|R1 |
|||
|- |
|||
!LiNbO3 |
|||
| |
| |
||
| |
| |
||
| |
| |
||
|A |
|||
|- bgcolor="#ffffff" |
|||
!Photoresist |
|||
& ARC |
|||
| |
| |
||
|A |
|||
|[https://wiki.nanotech.ucsb.edu/wiki/RIE_Etching_Recipes#Photoresist_and_ARC_.28RIE_5.29 R] |
|||
| |
| |
||
|[https://wiki.nanotech.ucsb.edu/wiki/ICP_Etching_Recipes#Photoresist_.26_ARC_.28Fluorine_ICP_Etcher.29 R] |
|||
|[https://wiki.nanotech.ucsb.edu/wiki/ICP_Etching_Recipes#Photoresist_and_ARC_Etching_.28Panasonic_1.29 R] |
|||
|[https://wiki.nanotech.ucsb.edu/wiki/ICP_Etching_Recipes#Photoresist_and_ARC_etching_.28Panasonic_2.29 R] |
|||
| |
| |
||
| |
| |
||
|A |
|||
|A |
|||
|A |
|||
| |
| |
||
| |
| |
||
| |
| |
||
| |
| |
||
|A |
|||
|- bgcolor="#eeffff" |
|||
! bgcolor="#d0e7ff" align="center" |SiC |
|||
| |
| |
||
| |
| |
||
|R1 |
|||
|- bgcolor="#ffffff" |
|||
!Photoresist & Organics |
|||
| |
| |
||
|[[RIE Etching Recipes|R3]] |
|||
| |
| |
||
|[[ICP Etching Recipes#Photoresist .26 ARC .28Fluorine ICP Etcher.29|R3]] |
|||
|[https://wiki.nanotech.ucsb.edu/wiki/ICP_Etching_Recipes#Photoresist_and_ARC_Etching_.28Panasonic_1.29 R] |
|||
|[[ICP Etching Recipes#Al2O3 Etching .28Panasonic 2.29|R3]] |
|||
| |
| |
||
|R3 |
|||
|{{rl|ICP Etching Recipes|SiC Etch (Panasonic 1)}} |
|||
|[[Oxygen Plasma System Recipes#O2 Ashing|R3]] |
|||
|A |
|||
|[[Oxygen Plasma System Recipes#O2 Ashing|R3]] |
|||
| |
| |
||
| |
| |
||
| |
| |
||
|R1 |
|||
|- |
|||
!ARC (Anti Reflective Coating) |
|||
| |
| |
||
| |
| |
||
| |
| |
||
|[[ICP Etching Recipes#Photoresist .26 ARC .28Fluorine ICP Etcher.29|R3]] |
|||
| |
| |
||
| |
| |
||
| |
| |
||
|A |
|||
|- bgcolor="#ffffff" |
|||
! bgcolor="#d0e7ff" align="center" |SiN |
|||
| |
| |
||
|{{rl|RIE Etching Recipes|RIE 3 (MRC)|SiN<sub>x</sub> Etching (RIE 3)}} |
|||
| |
| |
||
| |
| |
||
|A |
|||
|{{rl|ICP Etching Recipes|SiNx Etching (Panasonic 1)}} |
|||
|{{rl|ICP Etching Recipes|SiNx Etching (Panasonic 2)}} |
|||
| |
| |
||
| |
| |
||
|A |
|||
| |
| |
||
| |
| |
||
|- bgcolor="#eeffff" |
|||
! bgcolor="#d0e7ff" align="center" |SiC |
|||
| |
| |
||
| |
| |
||
| |
| |
||
| |
| |
||
|{{rl|ICP Etching Recipes|SiC Etch (Panasonic 1)}} |
|||
|A |
|||
|R1 |
|||
|- bgcolor="#eeffff" |
|||
! bgcolor="#d0e7ff" align="center" |SiO<sub>2</sub> |
|||
| |
| |
||
|{{rl|RIE Etching Recipes|RIE 3 (MRC)|SiO<sub>2</sub> Etching (RIE 3)}} |
|||
| |
| |
||
| |
| |
||
|{{rl|ICP Etching Recipes|SiO2 Etching (Fluorine ICP Etcher)}} |
|||
|{{rl|ICP Etching Recipes|SiO2 Etching (Panasonic 1)}} |
|||
|{{rl|ICP Etching Recipes|SiO2 Etching (Panasonic 2)}} |
|||
| |
| |
||
| |
| |
||
| |
| |
||
| |
| |
||
|R1 |
|||
|- bgcolor="#ffffff" |
|||
! bgcolor="#d0e7ff" align="center" |SiN |
|||
| |
| |
||
| |
| |
||
| |
| |
||
|[[ICP Etching Recipes#Si3N4 Etching .28Fluorine ICP Etcher.29|R3]] |
|||
|{{rl|ICP Etching Recipes|SiNx Etching (Panasonic 1)}} |
|||
|[[ICP Etching Recipes#SiNx Etching .28Panasonic 2.29|R3]] |
|||
| |
| |
||
|[[Oxygen Plasma System Recipes#O2 Ashing|R3]] |
|||
|{{rl|Other Dry Etching Recipes|Other Dry Etch (Vapor HF Etcher)}} |
|||
|A |
|||
|- bgcolor="#ffffff" |
|||
! bgcolor="#d0e7ff" align="center" |SiOxNy |
|||
| |
| |
||
| |
| |
||
| Line 626: | Line 620: | ||
| |
| |
||
| |
| |
||
| |
|R1 |
||
|- bgcolor="#eeffff" |
|||
|A |
|||
! bgcolor="#d0e7ff" align="center" |SiO<sub>2</sub> |
|||
| |
| |
||
| |
| |
||
| |
| |
||
|[[ICP Etching Recipes#SiO2 Etch Recipes (Fluorine ICP Etcher)|R6]] |
|||
|{{rl|ICP Etching Recipes|SiO2 Etching (Panasonic 1)}} |
|||
|[[ICP Etching Recipes#SiO2 Etching .28Panasonic 2.29|R6]] |
|||
| |
| |
||
| |
| |
||
| Line 637: | Line 635: | ||
| |
| |
||
| |
| |
||
|[[Other Dry Etching Recipes|R4]] |
|||
|A |
|||
|R1 |
|||
|- bgcolor="#eeffff" |
|||
|- bgcolor="#ffffff" |
|||
! bgcolor="#d0e7ff" align="center" |Ta<sub>2</sub>O<sub>5</sub> |
|||
! bgcolor="#d0e7ff" align="center" |SiOxNy |
|||
| |
| |
||
| |
| |
||
| |
| |
||
| |
| |
||
|A |
|||
|R1 |
|||
| |
| |
||
| |
| |
||
|[https://www.osapublishing.org/optica/abstract.cfm?uri=optica-4-5-532 A] |
|||
| |
| |
||
| |
| |
||
| Line 652: | Line 652: | ||
| |
| |
||
| |
| |
||
|R1 |
|||
|- |
|||
!SU8 |
|||
| |
| |
||
| |
| |
||
| Line 657: | Line 660: | ||
| |
| |
||
|A |
|A |
||
|- bgcolor="#ffffff" |
|||
! bgcolor="#d0e7ff" align="center" |TiN |
|||
| |
| |
||
| |
| |
||
| Line 668: | Line 669: | ||
| |
| |
||
| |
| |
||
|- bgcolor="#eeffff" |
|||
! bgcolor="#d0e7ff" align="center" |Ta<sub>2</sub>O<sub>5</sub> |
|||
| |
| |
||
| |
| |
||
| |
| |
||
| |
| |
||
|A |
|||
|R1 |
|||
| |
| |
||
| |
| |
||
| |
| |
||
|A |
|||
|- bgcolor="#eeffff" |
|||
! bgcolor="#d0e7ff" align="center" |TiO<sub>2</sub> |
|||
| |
| |
||
| |
| |
||
| |
| |
||
| |
| |
||
|R1 |
|||
|- bgcolor="#ffffff" |
|||
! bgcolor="#d0e7ff" align="center" |TiN |
|||
| |
| |
||
| |
| |
||
| Line 694: | Line 699: | ||
| |
| |
||
| |
| |
||
|A |
|||
|- bgcolor="#ffffff" |
|||
! bgcolor="#d0e7ff" align="center" |W-TiW |
|||
| |
| |
||
|R1 |
|||
|- bgcolor="#eeffff" |
|||
! bgcolor="#d0e7ff" align="center" |TiO<sub>2</sub> |
|||
| |
| |
||
| |
| |
||
| |
| |
||
| |
| |
||
|{{rl|ICP Etching Recipes|W-TiW Etch (Panasonic 1)}} |
|||
|A |
|||
| |
| |
||
| |
| |
||
| Line 713: | Line 716: | ||
| |
| |
||
| |
| |
||
| |
|R1 |
||
|- bgcolor="#eeffff" |
|- bgcolor="#eeffff" |
||
! bgcolor="#d0e7ff" align="center" |ZnO<sub>2</sub> |
! bgcolor="#d0e7ff" align="center" |ZnO<sub>2</sub> |
||
| Line 729: | Line 732: | ||
| |
| |
||
| |
| |
||
| |
|R1 |
||
| |
|||
| |
|||
|A |
|||
|- bgcolor="#ffffff" |
|- bgcolor="#ffffff" |
||
! bgcolor="#d0e7ff" align="center" |ZnS |
! bgcolor="#d0e7ff" align="center" |ZnS |
||
| |
|[[RIE Etching Recipes|R3]] |
||
| |
| |
||
| |
| |
||
| Line 748: | Line 748: | ||
| |
| |
||
| |
| |
||
| |
|R1 |
||
| |
|||
| |
|||
|A |
|||
|- bgcolor="#eeffff" |
|- bgcolor="#eeffff" |
||
! bgcolor="#d0e7ff" align="center" |ZnSe |
! bgcolor="#d0e7ff" align="center" |ZnSe |
||
| |
|[[RIE Etching Recipes|R2]] |
||
| |
| |
||
| |
| |
||
| Line 767: | Line 764: | ||
| |
| |
||
| |
| |
||
| |
|R1 |
||
| |
|||
| |
|||
|A |
|||
|- bgcolor="#ffffff" |
|- bgcolor="#ffffff" |
||
! bgcolor="#d0e7ff" align="center" |ZrO<sub>2</sub> |
! bgcolor="#d0e7ff" align="center" |ZrO<sub>2</sub> |
||
| Line 786: | Line 780: | ||
| |
| |
||
| |
| |
||
| |
|R1 |
||
| |
|||
| |
|||
|A |
|||
|- bgcolor="#eeffff" |
|- bgcolor="#eeffff" |
||
! bgcolor="#d0e7ff" align="center" |'''Material''' |
! bgcolor="#d0e7ff" align="center" |'''Material''' |
||
| bgcolor="#daf1ff" |[[RIE_Etching_Recipes#RIE_2_.28MRC.29|RIE 2<br> <span style="font-size: 88%;">(MRC)</span>]] |
| bgcolor="#daf1ff" |[[RIE_Etching_Recipes#RIE_2_.28MRC.29|RIE 2<br> <span style="font-size: 88%;">(MRC)</span>]] |
||
| bgcolor="#daf1ff" |[[RIE_Etching_Recipes#RIE_3_.28MRC.29|RIE 3<br> <span style="font-size: 88%;">(MRC)</span>]] |
|||
| bgcolor="#daf1ff" |[[RIE_Etching_Recipes#RIE_5_.28PlasmaTherm.29|RIE 5<br><span style="font-size: 88%;">(PlasmaTherm)</span>]] |
| bgcolor="#daf1ff" |[[RIE_Etching_Recipes#RIE_5_.28PlasmaTherm.29|RIE 5<br><span style="font-size: 88%;">(PlasmaTherm)</span>]] |
||
| bgcolor="#daf1ff" |[[ICP_Etching_Recipes#DSEIII_.28PlasmaTherm.2FDeep_Silicon_Etcher.29|DSEIII<br><span style="font-size: 88%;">(PlasmaTherm)</span>]] |
| bgcolor="#daf1ff" |[[ICP_Etching_Recipes#DSEIII_.28PlasmaTherm.2FDeep_Silicon_Etcher.29|DSEIII<br><span style="font-size: 88%;">(PlasmaTherm)</span>]] |
||
| bgcolor="#daf1ff" |[[ICP Etching Recipes#PlasmaTherm.2FSLR Fluorine Etcher|Fluorine ICP <span style="font-size: 88%;">(PlasmaTherm)</span>]] |
| bgcolor="#daf1ff" |[[ICP Etching Recipes#PlasmaTherm.2FSLR Fluorine Etcher|Fluorine ICP <span style="font-size: 88%;">(PlasmaTherm)</span>]] |
||
| bgcolor="#daf1ff" |[[ |
| bgcolor="#daf1ff" |[[ICP Etching Recipes#ICP Etch 1 .28Panasonic E646V.29|ICP Etch 1<br><span style="font-size: 88%;">(Panasonic E626I)</span>]] |
||
| bgcolor="#daf1ff" |[[ |
| bgcolor="#daf1ff" |[[ICP Etching Recipes#ICP Etch 2 .28Panasonic E626I.29|ICP Etch 2<br><span style="font-size: 88%;">(Panasonic E640)</span>]] |
||
| bgcolor="#daf1ff" |[[ICP Etching Recipes#Oxford ICP Etcher .28PlasmaPro 100 Cobra.29|Oxford ICP <span style="font-size: 88%;">(PlasmaPro 100)</span>]] |
| bgcolor="#daf1ff" |[[ICP Etching Recipes#Oxford ICP Etcher .28PlasmaPro 100 Cobra.29|Oxford ICP <span style="font-size: 88%;">(PlasmaPro 100)</span>]] |
||
| bgcolor="#daf1ff" |[[ICP_Etching_Recipes#ICP-Etch_.28Unaxis_VLR.29|ICP-Etch<br><span style="font-size: 88%;">(Unaxis VLR)</span>]] |
|||
| bgcolor="#daf1ff" |[[Oxygen_Plasma_System_Recipes#Ashers_.28Technics_PEII.29|Ashers<br><span style="font-size: 88%;">(Technics PEII)</span>]] |
| bgcolor="#daf1ff" |[[Oxygen_Plasma_System_Recipes#Ashers_.28Technics_PEII.29|Ashers<br><span style="font-size: 88%;">(Technics PEII)</span>]] |
||
| bgcolor="#daf1ff" |[[Oxygen_Plasma_System_Recipes#Plasma_Clean_.28Gasonics_2000.29|Plasma Clean<br><span style="font-size: 88%;">(Gasonics 2000)</span>]] |
|||
| bgcolor="#daf1ff" |[[Oxygen Plasma System Recipes#Plasma Clean .28YES EcoClean.29|Plasma Clean <span style="font-size: 88%;">(YES EcoClean)</span>]] |
| bgcolor="#daf1ff" |[[Oxygen Plasma System Recipes#Plasma Clean .28YES EcoClean.29|Plasma Clean <span style="font-size: 88%;">(YES EcoClean)</span>]] |
||
| bgcolor="#daf1ff" |[[Oxygen_Plasma_System_Recipes#UV_Ozone_Reactor|UV Ozone Reactor]] |
| bgcolor="#daf1ff" |[[Oxygen_Plasma_System_Recipes#UV_Ozone_Reactor|UV Ozone Reactor]] |
||
| Line 811: | Line 799: | ||
|} |
|} |
||
==='''Process Ranking Table'''=== |
|||
Processes in the table above are ranked by their "''Process Maturity Level''" as follows: |
|||
{| class="wikitable" |
|||
!Process Level |
|||
! colspan="11" |Description of Process Level Ranking |
|||
|- |
|||
|A |
|||
| colspan="11" |Process '''A'''llowed and materials available but never done |
|||
|- |
|||
|R1 |
|||
| colspan="11" |Process has been run at least once |
|||
|- |
|||
|R2 |
|||
| colspan="11" |Process has been run and/or procedure is documented or/and data available |
|||
|- |
|||
|R3 |
|||
| colspan="11" |Process has been run, procedure is documented, and data is available |
|||
|- |
|||
|R4 |
|||
| colspan="11" |Process has a documented procedure with regular (≥4x per year) data '''or''' lookahead/in-situ control available |
|||
|- |
|||
|R5 |
|||
| colspan="11" |Process has a documented procedure with regular (≥4x per year) data '''and''' lookahead/in-situ control available |
|||
|- |
|||
|R6 |
|||
| colspan="11" |Process has a documented procedure, regular ( ≥4x per year) data, and control charts & limits available |
|||
|} |
|||
[[Category:Processing]] |
[[Category:Processing]] |
||
Revision as of 18:55, 9 March 2025
Process Control Data
See above linked page for process control data (dep rate/stress etc. over time), for a selection of often-used dry etches
Dry Etching Tools/Materials Table
The Key/Legend for this table's A...R6 values is at the bottom of the page.
Process Ranking Table
Processes in the table above are ranked by their "Process Maturity Level" as follows:
| Process Level | Description of Process Level Ranking | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| A | Process Allowed and materials available but never done | ||||||||||
| R1 | Process has been run at least once | ||||||||||
| R2 | Process has been run and/or procedure is documented or/and data available | ||||||||||
| R3 | Process has been run, procedure is documented, and data is available | ||||||||||
| R4 | Process has a documented procedure with regular (≥4x per year) data or lookahead/in-situ control available | ||||||||||
| R5 | Process has a documented procedure with regular (≥4x per year) data and lookahead/in-situ control available | ||||||||||
| R6 | Process has a documented procedure, regular ( ≥4x per year) data, and control charts & limits available | ||||||||||