Main Page: Difference between revisions

From UCSB Nanofab Wiki
Jump to navigation Jump to search
(BIG update - pasted from Homepage_Draft1)
(added Tutorials <-- NEW)
 
(5 intermediate revisions by 2 users not shown)
Line 1: Line 1:
<!-- hide table of contents -->__NOTOC__
<!-- hide table of contents -->__NOTOC__
<!-- hide number -->__NONUMBEREDHEADINGS__
<!-- Hide "Main Page" title -->{{DISPLAYTITLE:<span style="position: absolute; clip: rect(1px 1px 1px 1px); clip: rect(1px, 1px, 1px, 1px);">{{FULLPAGENAME}}</span>}}
<!-- Hide "Main Page" title -->{{DISPLAYTITLE:<span style="position: absolute; clip: rect(1px 1px 1px 1px); clip: rect(1px, 1px, 1px, 1px);">{{FULLPAGENAME}}</span>}}
{{Homepage_Topbanners}}
{{Homepage_Topbanners}}
Line 11: Line 10:
!Recipes + Processes
!Recipes + Processes
!Data + Info
!Data + Info
|style="background: #fff;" rowspan=2|
| rowspan="2" style="background: #fff;" |
<div align="center" valign="top" style="font-weight: bold;">Other Links:</div>
<div align="center" style="font-weight: bold;" valign="top">Other Links:</div>
<!--| style="color:#000; background:#fff" |<div id="mp-tfa" style="padding:2px 5px"-->
<!--| style="color:#000; background:#fff" |<div id="mp-tfa" style="padding:2px 5px"-->

*[http://signupmonkey.ece.ucsb.edu SignUpMonkey]
*[http://signupmonkey.ece.ucsb.edu SignUpMonkey]
*[https://nanofab.ucsb.edu/services Get into the Lab]
*[https://nanofab.ucsb.edu/services Get into the Lab]
Line 20: Line 20:


*[http://nanofab.ucsb.edu NanoTech Homepage]
*[http://nanofab.ucsb.edu NanoTech Homepage]
*[[Nanofab Job Postings|NanoFab Job Postings]]
*[http://www.ece.ucsb.edu UCSB ECE Dept.]
*[http://www.ece.ucsb.edu UCSB ECE Dept.]
|- style="vertical-align:top;"
|- style="vertical-align:top;"
Line 29: Line 30:
*[[:Category:Thermal Processing|Thermal Process]]
*[[:Category:Thermal Processing|Thermal Process]]
*[[:Category:Packaging|Packaging/Bonding]]
*[[:Category:Packaging|Packaging/Bonding]]
*[[:Category:Inspection, Test and Characterization|Metrology/Test]]
*[[Tool List#Measurement .26 Characterization|Metrology/Test]]
|
|
*[[Lithography Recipes|Lithography]]
*[[Lithography Recipes|Lithography]]
Line 39: Line 40:
|
|
*[[Process Group - Process Control Data|Process Control Data]]
*[[Process Group - Process Control Data|Process Control Data]]
*[[Tutorials]] '''← NEW'''
*[[Calculators + Utilities|Calculators + Utilities]]
*[[Calculators + Utilities|Calculators + Utilities]]



Latest revision as of 21:10, 13 May 2025


Welcome to the UCSB Nanofab Wiki
Arrowleft3.png See sidebar for
             Equipment & Recipes
Make sure you know the
Lab Rules
Equipment Info Recipes + Processes Data + Info
Other Links:


Chemical processing is UP

There was a short ~30min campus water outage, but it has now been restored. Chemical usage/processing is now allowed as normal. // Demis D. John 18:36, 16 June 2025 (UTC)

Raith EBL Update

Unfortunately the fix discussed in the last update turned out to be a good news/bad news thing. The good news is that the majority of the field distortion problem we have experienced since the install has been addressed. However the bad news is that there is still a residual settling effect that is distorting the field in one part of the field only and prevents the tool from fully meeting specifications. So it turned out to a layers of an onion kind of thing – because of course it did.

So the suspect now is the fine focus coil in the column (one of the factory engineers predicted stitch shifts when a faulty fine focus coil is present which essentially replicated the errors we are now seeing) and the question now is how to get one of these sent to UCSB. They are a factory install item so for us to get one, and one that has been tested and confirmed to be fully operational, would require it to be taken from a tool currently under fabrication on the production line.

We are close, very close, but still not quite there. And I am really sorry that is still the case… -Bill // Demis D. John 22:53, 13 June 2025 (UTC)

SignupMonkey + Wiki: Off-Campus Access

Due to a DDoS attack affecting the Signupmonkey server, we have restricted access to the website to US locations only, including both the Nanofab Wiki and Signupmonkey.

If you are off-campus and experiencing issues, please utilize the UCSB VPN to access our sites. Here are the installation instructions for VPN on your device. You will need your UCSB NetID for download and installation - you would have received a UCSB NetID when you started using the NanoFab:

https://it.ucsb.edu/ivanti-secure-access-campus-vpn/get-connected-campus-vpn

-- Vraj // Demis D. John 20:08, 22 April 2025 (UTC)

Suss SB6-8E

We found a blown resistor (and a questionable op amp) on one of the boards that contains the z-axis motor circuit. However, we still cannot get the tool to initialize. Next we will try swapping out the hard drive again and run some more tests.

I will send out an update once we have one. -Aidan // Demis D. John 00:35, 8 December 2024 (UTC)

ICP1 Down

The board we were waiting on arrived, but it did not resolve the tool issue. We are working with Panasonic on the next steps. //Vraj Mehalana 14:17, 1 March 2024 (PST)

News & Announcements

News from the U.C. Santa Barbara Nanofabrication Facility.

DREAMS Hub awarded 2 projects in GaN and 5G/6G technologies

CA DREAMS Hub is awarded $31.9 million in funding under the Microelectronics Commons -

  • $16.2 Million to develop advanced gallium nitride (GaN) semiconductor technologies, with partners including USC, Northrop Grumman, Teledyne Technologies, HRL Laboratories, PseudolithIC, Monde Wireless Inc., Transphorm, UCLA and UC Santa Barbara.
  • $15.7 Million in Funding for 5G/6G millimeter-wave Phased-Array Prototypes, with team USC, Northrop Grumman, HRL Laboratories, Teledyne, Caltech, UCLA, UC Santa Barbara, UC San Diego, Vorago, Global Foundries.

// Demis D. John 16:32, 23 September 2024 (PDT)

NSF-ATE Award for SBCC and UCSB: New Semiconductor Pathway

The UCSB NanoFab and CNSI were recently awarded a project by NSF-ATE to build a semiconductor pathway (associates degree or certificate) at Santa Barbara City College, utilizing UCSB Cleanrooms. The project "Expansion of CCPRIME: Central Coast Partnership for Regional Industry-Focused Micro/Nanotechnology Education" is one of 6 projects funded by an Intel-NSF partnership. The project builds on the existing "Cleanroom Bootcamps" already being run twice a year in the CNSI QSF cleanroom. // Demis D. John 13:15, 14 August 2024 (PDT)

CHIPS Act Award Announced to USC and UCSB NanoFab

U.S. Congressman Salud Carbajal congratulates UCSB and the NanoFab on receiving a CHIPS & Science Act award, as part of the California DREAMS Hub (Microelectronics Commons) led by USC. -- Demis 12:06, 4 October 2023 (PDT)

RIE#3 Removed

We have removed RIE#3 from the Nanofab, it has gone to the Teaching Cleanroom. All user's processes have been transferred to the Fluorine ICP Etcher. // Demis D. John 15:58, 6 August 2024 (PDT)

NanoFab staff awarded Goleta's Innovator of the Year 2023

NanoFab staff member Demis D. John has been awarded the City of Goleta's "Innovator of the Year" for 2023! The award stems from the UCSB Nanofab's impact on the communities of Santa Barbara County and surrounding regions, in enabling cutting edge technology companies to thrive, which also enables many local careers in advanced high-tech. See the full announcement by the Santa Barbara South Coast Chamber of Commerce. // Demis D. John 13:58, 7 November 2023 (PST)

NanoFab Featured in Regional Tech Videos

The UCSB NanoFab is showcased as a driver of innovation and enabler of the regional high-tech industry.

See the videos here:

Santa Barbara County: This is TechTopia
Techtopia Vid - Thumbnail PlayButton.jpg
UCSB NanoFab: An Innovation Center
NanoFab COE Engineering Vid - thumbnail 2 crop.jpg

// John d 09:26, 1 November 2023 (PST)

See older articles at this link


General Information

  • NanoFab Users are responsible for understanding their chemistry, risks and usage of various chemicals. Please read the MSDS sheets for the chemicals you use!
  • Users can add qualified processing data to the Wiki pages; see the Editing_Tutorials for how to do that.
Bay3 v1.jpg
GowningRoom v2.jpg

  • Supervisors of individuals using the facility, e.g., UCSB Principal Investigators and external user managers are ultimately responsible for ensuring that their supervisees have the appropriate knowledge and training to work safely in the facility.
  • They are also responsible for ensuring that all applicable regulatory requirements are met. This includes having a compliant "Chemical Hygiene Plan" per OSHA regulations.
  • The information on this site should be considered as providing "general supporting information" to the Chemical Hygiene Plan of a particular supervisor. Supervisors can reference all or some of this site information within their Plans. UCSB EH&S can provide assistance to supervisors in preparing their Plans.


For any questions, comments or concerns regarding the wiki, please contact the NanoFab IT Team.