Thermal Evaporation Recipes: Difference between revisions

From UCSB Nanofab Wiki
Jump to navigation Jump to search
Content deleted Content added
Biljana (talk | contribs)
Biljana (talk | contribs)
 
(20 intermediate revisions by 2 users not shown)
Line 3: Line 3:
=[[Thermal Evaporator 1]]=
=[[Thermal Evaporator 1]]=


=Materials Table=
==Materials Table==


{| border="1" style="border: 1px solid #D0E7FF; background-color:#ffffff; text-align:center; font-size: 95%" class="collapsible collapsed wikitable"
{| border="1" style="border: 1px solid #D0E7FF; background-color:#ffffff; text-align:center; font-size: 95%" class="collapsible collapsed wikitable"
Line 67: Line 67:
|15.86
|15.86
|23.96
|23.96
⚫
||
|
|
|
|
⚫
|
|Used often
⚫
|
|-
|-
|Gold/Palladium
|Gold/Palladium
Line 76: Line 76:
|16.40
|16.40
|23.80
|23.80
⚫
||
|
|
|
|
|
|Used often
|
|-
|-
Gold/Zinc
|Gold/Zinc
|Au.95/Zn.05
|Au.95/Zn.05
|18.72
|18.72
Line 89: Line 89:
|
|
|
|
|Used often
|-
|-
Gold/Zinc
|Gold/Zinc
|Au.90/Zn.10
|Au.90/Zn.10
|18.07
|18.07
Line 99: Line 98:
|
|
|
|
|Used often
|-
|-
|Magnezium
|Magnesium
|Mg
|Mg
|1.74
|1.74
Line 182: Line 180:
|
|
|-
|-
|Strontium Fluoride
|StrontiumFluoride
|SrF<sub>2
|SrF<sub>2
|4.28
|4.28
Line 201: Line 199:
|-
|-
|ITO(IndiumTinOxide)
|ITO(IndiumTinOxide)
|In<sub>2O<sub>3-SnO<sub>2
|In<sub>2</sub>O<sub>3</sub> - SnO<sub>2
|5.43-7.14
|6.43-7.14
|0.841
|0.841
|
|
Line 210: Line 208:
|-
|-
|Permalloy
|Permalloy
|Ni<sub>0.1Fe<sub>0.2
|Ni<sub>0.1</sub>Fe<sub>0.2</sub>
|8.7
|8.7
|26.40
|26.40
Line 217: Line 215:
|0.1
|0.1
|
|
|-
|}


=[[Thermal Evaporator 2]]=
=[[Thermal Evaporator 2]]=


= Materials Table =
== Materials Table ==


{| border="1" style="border: 1px solid #D0E7FF; background-color:#ffffff; text-align:center; font-size: 95%" class="collapsible collapsed wikitable"
{| border="1" style="border: 1px solid #D0E7FF; background-color:#ffffff; text-align:center; font-size: 95%" class="collapsible collapsed wikitable"
Line 358: Line 356:
|0.841
|0.841
|120
|120
|Used often
|Used often, tooling factor needs adjustment
|-
|-
|Indium antimonide
|Indium antimonide
Line 574: Line 572:
|7.30
|7.30
|0.724
|0.724
|
|197
|Program #9, Tooling factor=200%, cold fixture
|Used often
|-
|-
|Titanium
|Titanium
Line 646: Line 644:
|
|
|
|
|-
|}

== In Deposition (Thermal Evaporator 2) ==
*[[Media:Thermal evaporator 2-new Sheet1.pdf|Indium evaporation Data]]

Latest revision as of 21:27, 19 June 2025

Back to Vacuum Deposition Recipes.

Thermal Evaporator 1

Materials Table

Thermal Evaporator 2

Materials Table

In Deposition (Thermal Evaporator 2)