===Dry Etching Tools/Materials Table=== |
===Dry Etching Tools/Materials Table=== |
||
==== Process Maturity Ranking ==== |
|||
* <code>'''R6'''</code> - most mature process with regular calibrations recorded on SPC charts. |
|||
* … |
|||
* <code>'''R1'''</code> - least mature - only run once ever. |
|||
''The Key/Legend for this table's <code>A...R6</code> values is at the [[Dry Etching Recipes#Process Ranking Table|bottom of the page]].'' |
''The Key/Legend for this table's <code>A...R6</code> values is at the [[Dry Etching Recipes#Process Ranking Table|bottom of the page]].'' |
||
{| class="wikitable" style="border: 1px solid #D0E7FF; background-color:#ffffff; text-align:center; font-size: 95%" border="1" |
{| class="wikitable" style="border: 1px solid #D0E7FF; background-color:#ffffff; text-align:center; font-size: 95%" border="1" |
||
| Line 44: | Line 51: | ||
| |
| |
||
| |
| |
||
| |
|R1 |
||
|- bgcolor="#ffffff" |
|- bgcolor="#ffffff" |
||
! bgcolor="#d0e7ff" align="center" |Al |
! bgcolor="#d0e7ff" align="center" |Al |
||
| |
| |
||
|[[RIE Etching Recipes| |
|[[RIE Etching Recipes|R2]] |
||
| |
| |
||
| |
| |
||
|{{rl|ICP Etching Recipes|Al Etch (Panasonic 1)}} |
|{{rl|ICP Etching Recipes|Al Etch (Panasonic 1)|R1}} |
||
|[[ICP Etching Recipes#Al Etch .28Panasonic 2.29|R2]] |
|||
|[https://wiki.nanofab.ucsb.edu/wiki/ICP_Etching_Recipes#Al_Etch_.28Panasonic_2.29 R2] |
|||
| |
| |
||
| |
| |
||
| Line 60: | Line 67: | ||
| |
| |
||
| |
| |
||
| |
|R1 |
||
|- bgcolor="#eeffff" |
|- bgcolor="#eeffff" |
||
! bgcolor="#d0e7ff" align="center" |Au |
! bgcolor="#d0e7ff" align="center" |Au |
||
| Line 76: | Line 83: | ||
| |
| |
||
| |
| |
||
| |
|[[Other Dry Etching Recipes|R3]] |
||
|- bgcolor="#ffffff" |
|- bgcolor="#ffffff" |
||
! bgcolor="#d0e7ff" align="center" |Cr |
! bgcolor="#d0e7ff" align="center" |Cr |
||
| |
| |
||
|[[RIE Etching Recipes|R2]] |
|||
|A |
|||
| |
| |
||
| |
| |
||
| Line 92: | Line 99: | ||
| |
| |
||
| |
| |
||
| |
|R1 |
||
|- bgcolor="#eeffff" |
|- bgcolor="#eeffff" |
||
! bgcolor="#d0e7ff" align="center" |Cu |
! bgcolor="#d0e7ff" align="center" |Cu |
||
| Line 108: | Line 115: | ||
| |
| |
||
| |
| |
||
| |
|R1 |
||
|- bgcolor="#ffffff" |
|- bgcolor="#ffffff" |
||
! bgcolor="#d0e7ff" align="center" |Ge |
! bgcolor="#d0e7ff" align="center" |Ge |
||
| Line 122: | Line 129: | ||
| |
| |
||
| |
| |
||
|[[Other Dry Etching Recipes|R2]] |
|||
|A |
|||
| |
| |
||
| |
|R1 |
||
|- bgcolor="#eeffff" |
|- bgcolor="#eeffff" |
||
! bgcolor="#d0e7ff" align="center" |Mo |
! bgcolor="#d0e7ff" align="center" |Mo |
||
| Line 140: | Line 147: | ||
| |
| |
||
| |
| |
||
| |
|R1 |
||
|- |
|- |
||
!Nb |
!Nb |
||
| Line 172: | Line 179: | ||
| |
| |
||
| |
| |
||
| |
|[[Other Dry Etching Recipes|R3]] |
||
|- |
|- |
||
!Os |
!Os |
||
| Line 204: | Line 211: | ||
| |
| |
||
| |
| |
||
| |
|[[Other Dry Etching Recipes|R3]] |
||
|- bgcolor="#ffffff" |
|- bgcolor="#ffffff" |
||
! bgcolor="#d0e7ff" align="center" |Ru |
! bgcolor="#d0e7ff" align="center" |Ru |
||
| Line 212: | Line 219: | ||
| |
| |
||
|A |
|A |
||
|[ |
|[[ICP Etching Recipes#Ru .28Ruthenium.29 Etch .28Panasonic 2.29|R3]] |
||
| |
| |
||
| |
| |
||
| Line 220: | Line 227: | ||
| |
| |
||
| |
| |
||
| |
|R1 |
||
|- bgcolor="#eeffff" |
|- bgcolor="#eeffff" |
||
! bgcolor="#d0e7ff" align="center" |Si |
! bgcolor="#d0e7ff" align="center" |Si |
||
| |
| |
||
| |
| |
||
|[[ICP Etching Recipes#High Rate Bosch Etch (DSEIII)|R6]], [[ICP Etching Recipes#Analogous FICP Recipes (DSEiii)|R3]] |
|||
|{{rl|ICP Etching Recipes|DSEIII_(PlasmaTherm/Deep_Silicon_Etcher)}} |
|||
|[[ICP Etching Recipes#Si |
|[[ICP Etching Recipes#Si Etch Recipes (Fluorine ICP Etcher)|R6]] |
||
| |
| |
||
| |
| |
||
| Line 234: | Line 241: | ||
| |
| |
||
| |
| |
||
| |
|[[Other Dry Etching Recipes|R3]] |
||
| |
| |
||
| |
|R1 |
||
|- bgcolor="#ffffff" |
|- bgcolor="#ffffff" |
||
! bgcolor="#d0e7ff" align="center" |Ta |
! bgcolor="#d0e7ff" align="center" |Ta |
||
| Line 252: | Line 259: | ||
| |
| |
||
| |
| |
||
| |
|R1 |
||
|- bgcolor="#eeffff" |
|- bgcolor="#eeffff" |
||
! bgcolor="#d0e7ff" align="center" |Ti |
! bgcolor="#d0e7ff" align="center" |Ti |
||
| Line 268: | Line 275: | ||
| |
| |
||
| |
| |
||
| |
|R1 |
||
|- bgcolor="#ffffff" |
|||
! bgcolor="#d0e7ff" align="center" |W |
|||
| |
|||
| |
|||
| |
|||
|R3 |
|||
|{{rl|ICP Etching Recipes|W-TiW Etch (Panasonic 1)}} |
|||
|R1 |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|R1 |
|||
|- |
|||
!TiW |
|||
| |
|||
| |
|||
| |
|||
|R3 |
|||
| |
|||
|R1 |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|- bgcolor="#ffffff" |
|- bgcolor="#ffffff" |
||
! bgcolor="#d0e7ff" align="center" |Al<sub>2</sub>O<sub>3</sub> |
! bgcolor="#d0e7ff" align="center" |Al<sub>2</sub>O<sub>3</sub> |
||
| Line 276: | Line 315: | ||
| |
| |
||
|A |
|A |
||
|[[ICP Etching Recipes#Al2O3 Etching .28Panasonic 2.29|R3]] |
|||
|[https://wiki.nanotech.ucsb.edu/w/index.php?title=ICP_Etching_Recipes#Al2O3_Etching_.28Panasonic_2.29 R3] |
|||
| |
| |
||
| |
| |
||
| Line 284: | Line 323: | ||
| |
| |
||
| |
| |
||
| |
|R1 |
||
|- bgcolor="#eeffff" |
|- bgcolor="#eeffff" |
||
! bgcolor="#d0e7ff" align="center" |Al<sub>2</sub>O<sub>3 (Sapphire)</sub> |
! bgcolor="#d0e7ff" align="center" |Al<sub>2</sub>O<sub>3 (Sapphire)</sub> |
||
| Line 300: | Line 339: | ||
| |
| |
||
| |
| |
||
| |
|R1 |
||
|- bgcolor="#ffffff" |
|- bgcolor="#ffffff" |
||
! bgcolor="#d0e7ff" align="center" |AlGaAs |
! bgcolor="#d0e7ff" align="center" |AlGaAs |
||
| |
| |
||
| |
|[[RIE Etching Recipes|R3]] |
||
| |
| |
||
| |
| |
||
| Line 316: | Line 355: | ||
| |
| |
||
| |
| |
||
| |
|R1 |
||
|- bgcolor="#eeffff" |
|- bgcolor="#eeffff" |
||
! bgcolor="#d0e7ff" align="center" |AlGaN |
! bgcolor="#d0e7ff" align="center" |AlGaN |
||
| Line 332: | Line 371: | ||
| |
| |
||
| |
| |
||
| |
|R1 |
||
|- bgcolor="#ffffff" |
|- bgcolor="#ffffff" |
||
! bgcolor="#d0e7ff" align="center" |AlN |
! bgcolor="#d0e7ff" align="center" |AlN |
||
| Line 348: | Line 387: | ||
| |
| |
||
| |
| |
||
| |
|R1 |
||
|- |
|- |
||
!BCB |
!BCB |
||
| Line 367: | Line 406: | ||
|- bgcolor="#eeffff" |
|- bgcolor="#eeffff" |
||
! bgcolor="#d0e7ff" align="center" |CdZnTe |
! bgcolor="#d0e7ff" align="center" |CdZnTe |
||
| |
|[[RIE Etching Recipes|R3]] |
||
| |
| |
||
| |
| |
||
| Line 380: | Line 419: | ||
| |
| |
||
| |
| |
||
| |
|R1 |
||
|- bgcolor="#ffffff" |
|- bgcolor="#ffffff" |
||
! bgcolor="#d0e7ff" align="center" |GaAs |
! bgcolor="#d0e7ff" align="center" |GaAs |
||
| |
| |
||
| |
|[[RIE Etching Recipes|R3]] |
||
| |
| |
||
| |
| |
||
|{{rl|ICP Etching Recipes|GaAs-AlGaAs Etch (Panasonic 1)}} |
|{{rl|ICP Etching Recipes|GaAs-AlGaAs Etch (Panasonic 1)}} |
||
|[[ICP Etching Recipes#GaAs Etch .28Panasonic 2.29|R6]] |
|||
|[https://wiki.nanofab.ucsb.edu/wiki/ICP_Etching_Recipes#GaAs_Etch_.28Panasonic_2.29 R3] |
|||
|[[ICP Etching Recipes#GaAs Etch .28Oxford ICP Etcher.29|R3]] |
|[[ICP Etching Recipes#GaAs Etch .28Oxford ICP Etcher.29|R3]] |
||
| |
| |
||
| Line 396: | Line 435: | ||
| |
| |
||
| |
| |
||
| |
|R1 |
||
|- bgcolor="#eeffff" |
|- bgcolor="#eeffff" |
||
! bgcolor="#d0e7ff" align="center" |GaN |
! bgcolor="#d0e7ff" align="center" |GaN |
||
| |
| |
||
| |
|[[RIE Etching Recipes|R3]] |
||
| |
| |
||
| |
| |
||
|{{rl|ICP Etching Recipes|GaN Etch (Panasonic 1)}} |
|{{rl|ICP Etching Recipes|GaN Etch (Panasonic 1)}} |
||
|R1 |
|R1 |
||
|[[ICP Etching Recipes#GaN Etch .28Oxford ICP Etcher.29| |
|[[ICP Etching Recipes#GaN Etch .28Oxford ICP Etcher.29|R6]] |
||
| |
| |
||
| |
| |
||
| Line 412: | Line 451: | ||
| |
| |
||
| |
| |
||
| |
|R1 |
||
|- bgcolor="#ffffff" |
|- bgcolor="#ffffff" |
||
! bgcolor="#d0e7ff" align="center" |GaSb |
! bgcolor="#d0e7ff" align="center" |GaSb |
||
| Line 428: | Line 467: | ||
| |
| |
||
| |
| |
||
| |
|R1 |
||
|- bgcolor="#eeffff" |
|- bgcolor="#eeffff" |
||
! bgcolor="#d0e7ff" align="center" |HfO<sub>2</sub> |
! bgcolor="#d0e7ff" align="center" |HfO<sub>2</sub> |
||
| Line 444: | Line 483: | ||
| |
| |
||
| |
| |
||
| |
|R1 |
||
|- bgcolor="#ffffff" |
|- bgcolor="#ffffff" |
||
! bgcolor="#d0e7ff" align="center" |InGaAlAs |
! bgcolor="#d0e7ff" align="center" |InGaAlAs |
||
| |
|[[RIE Etching Recipes|R3]] |
||
| |
| |
||
| |
| |
||
| Line 460: | Line 499: | ||
| |
| |
||
| |
| |
||
| |
|R1 |
||
|- bgcolor="#eeffff" |
|- bgcolor="#eeffff" |
||
! bgcolor="#d0e7ff" align="center" |InGaAsP |
! bgcolor="#d0e7ff" align="center" |InGaAsP |
||
| |
|[[RIE Etching Recipes|R3]] |
||
| |
| |
||
| |
| |
||
| Line 476: | Line 515: | ||
| |
| |
||
| |
| |
||
| |
|R1 |
||
|- bgcolor="#ffffff" |
|- bgcolor="#ffffff" |
||
! bgcolor="#d0e7ff" align="center" |InP |
! bgcolor="#d0e7ff" align="center" |InP |
||
| |
|[[RIE Etching Recipes|R3]] |
||
| |
| |
||
| |
| |
||
| Line 492: | Line 531: | ||
| |
| |
||
| |
| |
||
| |
|[[Other Dry Etching Recipes|R3]] |
||
|- bgcolor="#eeffff" |
|- bgcolor="#eeffff" |
||
! bgcolor="#d0e7ff" align="center" |ITO |
! bgcolor="#d0e7ff" align="center" |ITO |
||
| |
|[[RIE Etching Recipes|R3]] |
||
| |
| |
||
| |
| |
||
| Line 508: | Line 547: | ||
| |
| |
||
| |
| |
||
| |
|R1 |
||
|- |
|- |
||
!LiNbO3 |
!LiNbO3 |
||
| Line 524: | Line 563: | ||
| |
| |
||
| |
| |
||
| |
|R1 |
||
|- bgcolor="#ffffff" |
|- bgcolor="#ffffff" |
||
!Photoresist |
!Photoresist & Organics |
||
| |
|||
& ARC |
|||
|[[RIE Etching Recipes#Photoresist and ARC (RIE 5)|R3]] |
|||
| |
|||
|[[ICP Etching Recipes#Photoresist .26 ARC .28Fluorine ICP Etcher.29|R3]] |
|||
|[https://wiki.nanotech.ucsb.edu/wiki/ICP_Etching_Recipes#Photoresist_and_ARC_Etching_.28Panasonic_1.29 R3] |
|||
|[[ICP Etching Recipes#Al2O3 Etching .28Panasonic 2.29|R3]] |
|||
| |
|||
|R3 |
|||
|[[Oxygen Plasma System Recipes#O2 Ashing|R3]] |
|||
|[[Oxygen Plasma System Recipes#O2 Ashing|R3]] |
|||
| |
|||
| |
|||
| |
|||
|R1 |
|||
|- |
|||
!ARC (Anti Reflective Coating) |
|||
| |
|||
| |
|||
| |
|||
|[[ICP Etching Recipes#Photoresist .26 ARC .28Fluorine ICP Etcher.29|R3]] |
|||
| |
|||
| |
|||
| |
|||
| |
| |
||
|[https://wiki.nanotech.ucsb.edu/wiki/RIE_Etching_Recipes#Photoresist_and_ARC_.28RIE_5.29 R] |
|||
| |
| |
||
|[https://wiki.nanotech.ucsb.edu/wiki/ICP_Etching_Recipes#Photoresist_.26_ARC_.28Fluorine_ICP_Etcher.29 R4] |
|||
|[https://wiki.nanotech.ucsb.edu/wiki/ICP_Etching_Recipes#Photoresist_and_ARC_Etching_.28Panasonic_1.29 R] |
|||
|[https://wiki.nanotech.ucsb.edu/wiki/ICP_Etching_Recipes#Photoresist_and_ARC_etching_.28Panasonic_2.29 R3] |
|||
| |
| |
||
|[[Oxygen Plasma System Recipes#O2 Ashing|R]] |
|||
|[[Oxygen Plasma System Recipes#Plasma Clean .28YES EcoClean.29|R]] |
|||
| |
| |
||
| |
| |
||
| |
| |
||
| |
| |
||
|A |
|||
|- bgcolor="#eeffff" |
|- bgcolor="#eeffff" |
||
! bgcolor="#d0e7ff" align="center" |SiC |
! bgcolor="#d0e7ff" align="center" |SiC |
||
| Line 557: | Line 611: | ||
| |
| |
||
| |
| |
||
| |
|R1 |
||
|- bgcolor="#ffffff" |
|- bgcolor="#ffffff" |
||
! bgcolor="#d0e7ff" align="center" |SiN |
! bgcolor="#d0e7ff" align="center" |SiN |
||
| Line 563: | Line 617: | ||
| |
| |
||
| |
| |
||
|[[ICP Etching Recipes#Si3N4 Etching .28Fluorine ICP Etcher.29| |
|[[ICP Etching Recipes#Si3N4 Etching .28Fluorine ICP Etcher.29|R3]] |
||
|{{rl|ICP Etching Recipes|SiNx Etching (Panasonic 1)}} |
|{{rl|ICP Etching Recipes|SiNx Etching (Panasonic 1)}} |
||
|[[ICP Etching Recipes#SiNx Etching .28Panasonic 2.29|R3]] |
|||
|[https://wiki.nanofab.ucsb.edu/wiki/ICP_Etching_Recipes#SiNx_Etching_.28Panasonic_2.29 R3] |
|||
| |
| |
||
|[[Oxygen Plasma System Recipes#O2 Ashing|R3]] |
|||
|A |
|||
| |
| |
||
| |
| |
||
| Line 573: | Line 627: | ||
| |
| |
||
| |
| |
||
| |
|R1 |
||
|- bgcolor="#eeffff" |
|- bgcolor="#eeffff" |
||
! bgcolor="#d0e7ff" align="center" |SiO<sub>2</sub> |
! bgcolor="#d0e7ff" align="center" |SiO<sub>2</sub> |
||
| |
| |
||
| |
| |
||
|[[ICP Etching Recipes#Analogous FICP Recipes (DSEiii)|R3]] |
|||
| |
|||
|[[ICP Etching Recipes#SiO2 |
|[[ICP Etching Recipes#SiO2 Etch Recipes (Fluorine ICP Etcher)|R6]] |
||
|{{rl|ICP Etching Recipes|SiO2 Etching (Panasonic 1)}} |
|{{rl|ICP Etching Recipes|SiO2 Etching (Panasonic 1)}} |
||
|[[ICP Etching Recipes#SiO2 Etching .28Panasonic 2.29|R6]] |
|||
|[https://wiki.nanofab.ucsb.edu/wiki/ICP_Etching_Recipes#SiO2_Etching_.28Panasonic_2.29 R6] |
|||
| |
| |
||
| |
| |
||
| Line 588: | Line 642: | ||
| |
| |
||
| |
| |
||
| |
|[[Other Dry Etching Recipes|R3]] |
||
| |
|R1 |
||
|- bgcolor="#ffffff" |
|- bgcolor="#ffffff" |
||
! bgcolor="#d0e7ff" align="center" |SiOxNy |
! bgcolor="#d0e7ff" align="center" |SiOxNy |
||
| Line 605: | Line 659: | ||
| |
| |
||
| |
| |
||
| |
|R1 |
||
|- |
|- |
||
!SU8 |
!SU8 |
||
| Line 629: | Line 683: | ||
| |
| |
||
|A |
|A |
||
|R1 |
|||
|[https://www.osapublishing.org/optica/abstract.cfm?uri=optica-4-5-532 R1] |
|||
| |
| |
||
| |
| |
||
| Line 637: | Line 691: | ||
| |
| |
||
| |
| |
||
| |
|R1 |
||
|- bgcolor="#ffffff" |
|- bgcolor="#ffffff" |
||
! bgcolor="#d0e7ff" align="center" |TiN |
! bgcolor="#d0e7ff" align="center" |TiN |
||
| Line 653: | Line 707: | ||
| |
| |
||
| |
| |
||
| |
|R1 |
||
|- bgcolor="#eeffff" |
|- bgcolor="#eeffff" |
||
! bgcolor="#d0e7ff" align="center" |TiO<sub>2</sub> |
! bgcolor="#d0e7ff" align="center" |TiO<sub>2</sub> |
||
| Line 669: | Line 723: | ||
| |
| |
||
| |
| |
||
|A |
|||
|- bgcolor="#ffffff" |
|||
! bgcolor="#d0e7ff" align="center" |W-TiW |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|{{rl|ICP Etching Recipes|W-TiW Etch (Panasonic 1)}} |
|||
|R1 |
|R1 |
||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|A |
|||
|- bgcolor="#eeffff" |
|- bgcolor="#eeffff" |
||
! bgcolor="#d0e7ff" align="center" |ZnO<sub>2</sub> |
! bgcolor="#d0e7ff" align="center" |ZnO<sub>2</sub> |
||
| Line 701: | Line 739: | ||
| |
| |
||
| |
| |
||
| |
|R1 |
||
|- bgcolor="#ffffff" |
|- bgcolor="#ffffff" |
||
! bgcolor="#d0e7ff" align="center" |ZnS |
! bgcolor="#d0e7ff" align="center" |ZnS |
||
| |
|[[RIE Etching Recipes|R3]] |
||
| |
| |
||
| |
| |
||
| Line 717: | Line 755: | ||
| |
| |
||
| |
| |
||
| |
|R1 |
||
|- bgcolor="#eeffff" |
|- bgcolor="#eeffff" |
||
! bgcolor="#d0e7ff" align="center" |ZnSe |
! bgcolor="#d0e7ff" align="center" |ZnSe |
||
| |
|[[RIE Etching Recipes|R2]] |
||
| |
| |
||
| |
| |
||
| Line 733: | Line 771: | ||
| |
| |
||
| |
| |
||
| |
|R1 |
||
|- bgcolor="#ffffff" |
|- bgcolor="#ffffff" |
||
! bgcolor="#d0e7ff" align="center" |ZrO<sub>2</sub> |
! bgcolor="#d0e7ff" align="center" |ZrO<sub>2</sub> |
||
| Line 749: | Line 787: | ||
| |
| |
||
| |
| |
||
| |
|R1 |
||
|- bgcolor="#eeffff" |
|- bgcolor="#eeffff" |
||
! bgcolor="#d0e7ff" align="center" |'''Material''' |
! bgcolor="#d0e7ff" align="center" |'''Material''' |
||
| Line 768: | Line 806: | ||
|} |
|} |
||
=== |
===Process Ranking Table=== |
||
Processes in the table above are ranked by their "''Process Maturity Level''" as follows: |
Processes in the table above are ranked by their "''Process Maturity Level''" as follows: |
||
{| class="wikitable" |
{| class="wikitable" |
||
| Line 778: | Line 816: | ||
|- |
|- |
||
|R1 |
|R1 |
||
| colspan="11" |Process has been |
| colspan="11" |Process has been ran at least once |
||
|- |
|- |
||
|R2 |
|R2 |
||
| colspan="11" |Process has been |
| colspan="11" |Process has been ran and procedure is documented |
||
|- |
|- |
||
|R3 |
|R3 |
||
| colspan="11" |Process has been |
| colspan="11" |Process has been ran, procedure is documented, and data is available |
||
|- |
|- |
||
|R4 |
|R4 |
||
| colspan="11" |Process has a documented procedure with regular |
| colspan="11" |Process has a documented procedure with regular (≥4x per year) data '''no''' in-Situ control available |
||
|- |
|- |
||
|R5 |
|R5 |
||
| colspan="11" |Process has a documented procedure with regular |
| colspan="11" |Process has a documented procedure with regular (≥4x per year) data '''and''' in-Situ control available |
||
|- |
|- |
||
|R6 |
|R6 |
||
| colspan="11" |Process has a documented procedure |
| colspan="11" |Process has a documented procedure and control charts/limits available. Controlled process. |
||
|} |
|} |
||
[[Category:Processing]] |
[[Category:Processing]] |
||
Latest revision as of 01:16, 10 February 2026
Process Control Data
See above linked page for process control data (dep rate/stress etc. over time), for a selection of often-used dry etches
Dry Etching Tools/Materials Table
Process Maturity Ranking
R6- most mature process with regular calibrations recorded on SPC charts.- …
R1- least mature - only run once ever.
The Key/Legend for this table's A...R6 values is at the bottom of the page.
Process Ranking Table
Processes in the table above are ranked by their "Process Maturity Level" as follows:
| Process Level | Description of Process Level Ranking | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| A | Process Allowed and materials available but never done | ||||||||||
| R1 | Process has been ran at least once | ||||||||||
| R2 | Process has been ran and procedure is documented | ||||||||||
| R3 | Process has been ran, procedure is documented, and data is available | ||||||||||
| R4 | Process has a documented procedure with regular (≥4x per year) data no in-Situ control available | ||||||||||
| R5 | Process has a documented procedure with regular (≥4x per year) data and in-Situ control available | ||||||||||
| R6 | Process has a documented procedure and control charts/limits available. Controlled process. | ||||||||||