Process Group Interns: Difference between revisions
Jump to navigation
Jump to search
Content deleted Content added
added Leyna |
→Current Interns: Rudro only did <1mo of work so taking him off |
||
| (11 intermediate revisions by 2 users not shown) | |||
| Line 8: | Line 8: | ||
! align="center" bgcolor="#D0E7FF" width="150" |'''Tasks''' |
! align="center" bgcolor="#D0E7FF" width="150" |'''Tasks''' |
||
!Semesters |
!Semesters |
||
| ⚫ | |||
| ⚫ | |||
| ⚫ | |||
| ⚫ | |||
|Spring 2025–present |
|||
| ⚫ | |||
| ⚫ | |||
| ⚫ | |||
| ⚫ | |||
|Spring 2025–present |
|||
| ⚫ | |||
| ⚫ | |||
| ⚫ | |||
| ⚫ | |||
|Spring 2025–present |
|||
| ⚫ | |||
| ⚫ | |||
| ⚫ | |||
| ⚫ | |||
|Spring 2025–present |
|||
| ⚫ | |||
| ⚫ | |||
| ⚫ | |||
| ⚫ | |||
| ⚫ | |||
|- |
|- |
||
|Ana Jevremoviç |
|Ana Jevremoviç |
||
|Santa Barbara City College: Materials Science and Engineering |
|Santa Barbara City College: Materials Science and Engineering |
||
|PECVD Dep |
|PECVD Dep, Dry Etch/SEM, Litho |
||
|Fall 2025–present |
|Fall 2025–present |
||
|- |
|- |
||
| Line 46: | Line 21: | ||
|Leyna Chau |
|Leyna Chau |
||
|Chemical Engineering |
|Chemical Engineering |
||
|Litho, Dry Etch/SEM |
|Litho, Dry Etch/SEM, Sputter/EBeam Dep |
||
|Fall 2025–present |
|Fall 2025–present |
||
| ⚫ | |||
|Trace Chadwick |
|||
|Highschool (no major) |
|||
| ⚫ | |||
|Jan 2026–present |
|||
| ⚫ | |||
|Alex West |
|||
| ⚫ | |||
| ⚫ | |||
|Jan 2026–present |
|||
|} |
|} |
||
| Line 57: | Line 42: | ||
! align="center" bgcolor="#D0E7FF" width="150" |'''Tasks''' |
! align="center" bgcolor="#D0E7FF" width="150" |'''Tasks''' |
||
!Semesters |
!Semesters |
||
| ⚫ | |||
| ⚫ | |||
| ⚫ | |||
| ⚫ | |||
| ⚫ | |||
| ⚫ | |||
| ⚫ | |||
| ⚫ | |||
|Dry Etch & Litho, LithoCal development |
|||
|Spring 2025–Fall 2025 |
|||
| ⚫ | |||
| ⚫ | |||
| ⚫ | |||
|Glass Dep, Litho, Dry Etch |
|||
|Spring 2025–Fall 2025 |
|||
|- |
|||
| ⚫ | |||
| ⚫ | |||
| ⚫ | |||
|Spring 2025–Fall 2025 |
|||
|- |
|||
| ⚫ | |||
|Electrical Engineering |
|||
| ⚫ | |||
|Spring 2025–Fall 2025 |
|||
|- |
|- |
||
|Terry Guerrero |
|Terry Guerrero |
||
| Line 65: | Line 75: | ||
|Javier Zamora Juarez |
|Javier Zamora Juarez |
||
|Electrical Engineering |
|Electrical Engineering |
||
|PECVD Dep, Dry Etch, Lithography, E-Beam Dep (Developed), |
|PECVD Dep, Dry Etch, Lithography, E-Beam Dep (Developed), Litho Development |
||
|Summer 2024-Spring 2025 |
|Summer 2024-Spring 2025 |
||
|- |
|- |
||
|Jiaheng "Robin" Teng |
|Jiaheng "Robin" Teng |
||
|Mechanical Engineering |
|Mechanical Engineering |
||
|PECVD Deposition, Dry Etch, Lithography, Ion Beam Dep, ICP-PEVCD Dep |
|PECVD Deposition, Dry Etch, Lithography, Ion Beam Dep, ICP-PEVCD Dep, Litho Development |
||
|Spring 2024–July 2025 |
|Spring 2024–July 2025 |
||
|- |
|- |
||
Latest revision as of 17:19, 31 March 2026
The process group hosts a number of interns each year! Find out more on our internship page.
Current Interns
| Name | Major | Tasks | Semesters |
|---|---|---|---|
| Ana Jevremoviç | Santa Barbara City College: Materials Science and Engineering | PECVD Dep, Dry Etch/SEM, Litho | Fall 2025–present |
| Akhila Johny | Electrical Engineering | PECVD Dep, Dry Etch/SEM, Litho | Fall 2025–present |
| Leyna Chau | Chemical Engineering | Litho, Dry Etch/SEM, Sputter/EBeam Dep | Fall 2025–present |
| Trace Chadwick | Highschool (no major) | PECVD Glass Deps, Litho | Jan 2026–present |
| Alex West | Electrical Engineering | Dry Etch/SEM, Litho | Jan 2026–present |
Alumni
| Name | Major | Tasks | Semesters |
|---|---|---|---|
| Diego Caceres Ceballos | Physics | Dry Etch, PECVD Dep, Sputter Development, Bosch etch development | Summer 2025-Fall 2025 |
| Ornob Barua | Mechanical Engineering | Dry Etch & Litho, LithoCal development | Spring 2025–Fall 2025 |
| Tanvi Kamath | Chemical Engineering | Glass Dep, Litho, Dry Etch | Spring 2025–Fall 2025 |
| William Cheng | Electrical & Computer Engineering | Dry Etch, Glass Dep & Litho | Spring 2025–Fall 2025 |
| Shiven Bhatt | Electrical Engineering | Dry Etch, PECVD Dep | Spring 2025–Fall 2025 |
| Terry Guerrero | Physics | Dry Etch, PECVD Dep, Dry Etch, Lithography, Metal Dep, ICP-PECVD, Ion-Beam Dep | Fall 2024-Spring 2025 |
| Javier Zamora Juarez | Electrical Engineering | PECVD Dep, Dry Etch, Lithography, E-Beam Dep (Developed), Litho Development | Summer 2024-Spring 2025 |
| Jiaheng "Robin" Teng | Mechanical Engineering | PECVD Deposition, Dry Etch, Lithography, Ion Beam Dep, ICP-PEVCD Dep, Litho Development | Spring 2024–July 2025 |
| Dhruv Patel | Computer Science | Dry Etch, PECVD Dep, Lithography | Summer 2024–Winter 2025 |
| Haley Hughes | Electrical Engineering | PECVD Dep, ICP-PECVD Dep., Dry Etch, Lithography | Winter 2024–Winter 2025 |
| William Matthews | Dos Pueblos High School | PECVD Dep, Dry Etch, Lithography | Summer 2023–Summer 2024 |
| Phineas Lehan | Chemical Engineering | Dry Etch, PECVD Deposition | Winter 2023–Spring 2024 |
| Allison Lebus | Electrical Engineering | PECVD Deposition, ICP-PECVD Dep, Ion Beam Dep., Traveler/spreadsheet Automation | Winter 2023–Spring 2024 |
| Judas Strayer | Physics | PECVD Dep., Dry Etch, Data Analysis | Fall 2022–Summer 2023 |
| Henry Allen | Mechanical Engineering | PECVD Deposition | Summer 2022–Fall 2022 |
| Noah Dutra | Chemical Engineering | Dry Etch, Lithography Development | Spring 2022–Spring 2023 |
| Nirav Pakala | Electrical Engineering | Dry Etch & Dry Etch Development/DOE | Winter 2022–Summer 2022 |
| Salim Tarazi | Electrical Engineering | PECVD Deposition | Winter 2022–Summer 2022 |
| Nastazia Moshirfatemi | Physics | PECVD Deposition, ICP-PECVD Dep, Ion Beam Dep, Data Analysis & Visualization | Summer 2021–Winter 2022 |