Dry Etching Recipes: Difference between revisions
Jump to navigation
Jump to search
Content deleted Content added
changed "Process Control Data" link at the top so it didn't have an "f" at the front of it. |
linked W etch FICP |
||
| (46 intermediate revisions by 3 users not shown) | |||
| Line 3: | Line 3: | ||
===Dry Etching Tools/Materials Table=== |
===Dry Etching Tools/Materials Table=== |
||
==== Process Maturity Ranking ==== |
|||
* <code>'''R6'''</code> - most mature process with regular calibrations recorded on SPC charts. |
|||
* … |
|||
* <code>'''R1'''</code> - least mature - only run once ever. |
|||
''The Key/Legend for this table's <code>A...R6</code> values is at the [[Dry Etching Recipes#Process Ranking Table|bottom of the page]].'' |
''The Key/Legend for this table's <code>A...R6</code> values is at the [[Dry Etching Recipes#Process Ranking Table|bottom of the page]].'' |
||
{| class="wikitable" style="border: 1px solid #D0E7FF; background-color:#ffffff; text-align:center; font-size: 95%" border="1" |
{| class="wikitable" style="border: 1px solid #D0E7FF; background-color:#ffffff; text-align:center; font-size: 95%" border="1" |
||
|- |
|- |
||
! colspan=" |
! colspan="15" width="725" height="45" |<div style="font-size: 150%;">Dry Etching Recipes</div> |
||
|- bgcolor="#d0e7ff" |
|- bgcolor="#d0e7ff" |
||
| bgcolor="#eaecf0" |<!-- INTENTIONALLY LEFT BLANK --> |
| bgcolor="#eaecf0" |<!-- INTENTIONALLY LEFT BLANK --> |
||
! colspan=" |
! colspan="2" |'''[[RIE Etching Recipes|RIE Etching]]''' |
||
! colspan=" |
! colspan="5" |'''[[ICP Etching Recipes|ICP Etching]]''' |
||
! colspan="4" bgcolor="#d0e7ff" align="center" |'''[[Oxygen Plasma System Recipes|Oxygen Plasma Systems]]''' |
! colspan="4" bgcolor="#d0e7ff" align="center" |'''[[Oxygen Plasma System Recipes|Oxygen Plasma Systems]]''' |
||
! colspan="3" bgcolor="#d0e7ff" align="center" |'''[[Other Dry Etching Recipes|Other Dry Etchers]]''' |
! colspan="3" bgcolor="#d0e7ff" align="center" |'''[[Other Dry Etching Recipes|Other Dry Etchers]]''' |
||
| Line 16: | Line 23: | ||
! bgcolor="#d0e7ff" align="center" |'''Material''' |
! bgcolor="#d0e7ff" align="center" |'''Material''' |
||
| bgcolor="#daf1ff" |[[RIE_Etching_Recipes#RIE_2_.28MRC.29|RIE 2<br> <span style="font-size: 88%;">(MRC)</span>]] |
| bgcolor="#daf1ff" |[[RIE_Etching_Recipes#RIE_2_.28MRC.29|RIE 2<br> <span style="font-size: 88%;">(MRC)</span>]] |
||
| bgcolor="#daf1ff" |[[RIE_Etching_Recipes#RIE_3_.28MRC.29|RIE 3<br> <span style="font-size: 88%;">(MRC)</span>]] |
|||
| bgcolor="#daf1ff" |[[RIE_Etching_Recipes#RIE_5_.28PlasmaTherm.29|RIE 5<br><span style="font-size: 88%;">(PlasmaTherm)</span>]] |
| bgcolor="#daf1ff" |[[RIE_Etching_Recipes#RIE_5_.28PlasmaTherm.29|RIE 5<br><span style="font-size: 88%;">(PlasmaTherm)</span>]] |
||
| bgcolor="#daf1ff" |[[ICP_Etching_Recipes#DSEIII_.28PlasmaTherm.2FDeep_Silicon_Etcher.29|DSEIII<br><span style="font-size: 88%;">(PlasmaTherm)</span>]] |
| bgcolor="#daf1ff" |[[ICP_Etching_Recipes#DSEIII_.28PlasmaTherm.2FDeep_Silicon_Etcher.29|DSEIII<br><span style="font-size: 88%;">(PlasmaTherm)</span>]] |
||
| Line 23: | Line 29: | ||
| bgcolor="#daf1ff" |[[ICP Etching Recipes#ICP Etch 2 .28Panasonic E626I.29|ICP Etch 2<br><span style="font-size: 88%;">(Panasonic E626I)</span>]] |
| bgcolor="#daf1ff" |[[ICP Etching Recipes#ICP Etch 2 .28Panasonic E626I.29|ICP Etch 2<br><span style="font-size: 88%;">(Panasonic E626I)</span>]] |
||
| bgcolor="#daf1ff" |[[ICP Etching Recipes#Oxford ICP Etcher .28PlasmaPro 100 Cobra.29|Oxford ICP <span style="font-size: 88%;">(PlasmaPro 100)</span>]] |
| bgcolor="#daf1ff" |[[ICP Etching Recipes#Oxford ICP Etcher .28PlasmaPro 100 Cobra.29|Oxford ICP <span style="font-size: 88%;">(PlasmaPro 100)</span>]] |
||
| bgcolor="#daf1ff" |[[ICP_Etching_Recipes#ICP-Etch_.28Unaxis_VLR.29|ICP-Etch<br><span style="font-size: 88%;">(Unaxis VLR)</span>]] |
|||
| bgcolor="#daf1ff" |[[Oxygen_Plasma_System_Recipes#Ashers_.28Technics_PEII.29|Ashers<br><span style="font-size: 88%;">(Technics PEII)</span>]] |
| bgcolor="#daf1ff" |[[Oxygen_Plasma_System_Recipes#Ashers_.28Technics_PEII.29|Ashers<br><span style="font-size: 88%;">(Technics PEII)</span>]] |
||
| bgcolor="#daf1ff" |[[Oxygen Plasma System Recipes#Plasma Clean .28YES EcoClean.29|Plasma Clean <span style="font-size: 88%;">(YES EcoClean)</span>]] |
| bgcolor="#daf1ff" |[[Oxygen Plasma System Recipes#Plasma Clean .28YES EcoClean.29|Plasma Clean <span style="font-size: 88%;">(YES EcoClean)</span>]] |
||
| Line 46: | Line 51: | ||
| |
| |
||
| |
| |
||
| |
|R1 |
||
| |
|||
|A |
|||
|- bgcolor="#ffffff" |
|- bgcolor="#ffffff" |
||
! bgcolor="#d0e7ff" align="center" |Al |
! bgcolor="#d0e7ff" align="center" |Al |
||
| |
| |
||
|[[RIE Etching Recipes|R2]] |
|||
| |
| |
||
|[[RIE Etching Recipes|A]] |
|||
| |
| |
||
|{{rl|ICP Etching Recipes|Al Etch (Panasonic 1)|R1}} |
|||
|[[ICP Etching Recipes#Al Etch .28Panasonic 2.29|R2]] |
|||
| |
| |
||
|{{rl|ICP Etching Recipes|Al Etch (Panasonic 1)}} |
|||
|[https://wiki.nanofab.ucsb.edu/wiki/ICP_Etching_Recipes#Al_Etch_.28Panasonic_2.29 R2] |
|||
| |
| |
||
| |
| |
||
| Line 64: | Line 67: | ||
| |
| |
||
| |
| |
||
| |
|R1 |
||
| |
|||
|A |
|||
|- bgcolor="#eeffff" |
|- bgcolor="#eeffff" |
||
! bgcolor="#d0e7ff" align="center" |Au |
! bgcolor="#d0e7ff" align="center" |Au |
||
| Line 82: | Line 83: | ||
| |
| |
||
| |
| |
||
|[[Other Dry Etching Recipes|R3]] |
|||
| |
|||
| |
|||
|{{rl|Other Dry Etching Recipes|Other Dry Etch (CAIBE (Oxford Ion Mill))}} |
|||
|- bgcolor="#ffffff" |
|- bgcolor="#ffffff" |
||
! bgcolor="#d0e7ff" align="center" |Cr |
! bgcolor="#d0e7ff" align="center" |Cr |
||
| |
| |
||
|[[RIE Etching Recipes|R2]] |
|||
| |
|||
|A |
|||
| |
| |
||
| |
| |
||
|{{rl|ICP Etching Recipes|Cr Etch (Panasonic 1)}} |
|{{rl|ICP Etching Recipes|Cr Etch (Panasonic 1)}} |
||
|[[ICP Etching Recipes#Cr Etching (Panasonic 2)|R3]] |
|||
|R1 |
|||
| |
| |
||
| |
| |
||
| Line 101: | Line 99: | ||
| |
| |
||
| |
| |
||
| |
|R1 |
||
|A |
|||
|- bgcolor="#eeffff" |
|- bgcolor="#eeffff" |
||
! bgcolor="#d0e7ff" align="center" |Cu |
! bgcolor="#d0e7ff" align="center" |Cu |
||
| Line 118: | Line 115: | ||
| |
| |
||
| |
| |
||
| |
|R1 |
||
| |
|||
|A |
|||
|- bgcolor="#ffffff" |
|- bgcolor="#ffffff" |
||
! bgcolor="#d0e7ff" align="center" |Ge |
! bgcolor="#d0e7ff" align="center" |Ge |
||
| |
|||
| |
| |
||
| |
| |
||
| Line 135: | Line 129: | ||
| |
| |
||
| |
| |
||
|[[Other Dry Etching Recipes|R2]] |
|||
| |
| |
||
| |
|R1 |
||
| |
|||
|A |
|||
|- bgcolor="#eeffff" |
|- bgcolor="#eeffff" |
||
! bgcolor="#d0e7ff" align="center" |Mo |
! bgcolor="#d0e7ff" align="center" |Mo |
||
| Line 154: | Line 147: | ||
| |
| |
||
| |
| |
||
| |
|R1 |
||
| |
|||
|A |
|||
|- |
|- |
||
!Nb |
!Nb |
||
| |
|||
| |
| |
||
| |
| |
||
| Line 166: | Line 156: | ||
|A |
|A |
||
|R1 |
|R1 |
||
| |
|||
| |
| |
||
| |
| |
||
| Line 190: | Line 179: | ||
| |
| |
||
| |
| |
||
|[[Other Dry Etching Recipes|R3]] |
|||
| |
|||
| |
|||
|{{rl|Other Dry Etching Recipes|Other Dry Etch (CAIBE (Oxford Ion Mill))}} |
|||
|- |
|- |
||
!Os |
!Os |
||
| |
|||
| |
| |
||
| |
| |
||
| Line 202: | Line 188: | ||
|A |
|A |
||
|R1 |
|R1 |
||
| |
|||
| |
| |
||
| |
| |
||
| Line 226: | Line 211: | ||
| |
| |
||
| |
| |
||
|[[Other Dry Etching Recipes|R3]] |
|||
| |
|||
| |
|||
|{{rl|Other Dry Etching Recipes|Other Dry Etch (CAIBE (Oxford Ion Mill))}} |
|||
|- bgcolor="#ffffff" |
|- bgcolor="#ffffff" |
||
! bgcolor="#d0e7ff" align="center" |Ru |
! bgcolor="#d0e7ff" align="center" |Ru |
||
| |
|||
| |
| |
||
| |
| |
||
| Line 237: | Line 219: | ||
| |
| |
||
|A |
|A |
||
|[ |
|[[ICP Etching Recipes#Ru .28Ruthenium.29 Etch .28Panasonic 2.29|R3]] |
||
| |
| |
||
| |
| |
||
| Line 245: | Line 227: | ||
| |
| |
||
| |
| |
||
| |
|R1 |
||
|A |
|||
|- bgcolor="#eeffff" |
|- bgcolor="#eeffff" |
||
! bgcolor="#d0e7ff" align="center" |Si |
! bgcolor="#d0e7ff" align="center" |Si |
||
| |
| |
||
| |
| |
||
|[[ICP Etching Recipes#High Rate Bosch Etch (DSEIII)|R6]], [[ICP Etching Recipes#Silicon: Single-Step, Low Etch Rate, Smooth Sidewall Process (DSEIII)|R3]] |
|||
| |
|||
| |
|[[ICP Etching Recipes#Si Etch Recipes (Fluorine ICP Etcher)|R6]] |
||
|[[ICP Etching Recipes#Si Etching .28Fluorine ICP Etcher.29|R3]] |
|||
| |
| |
||
| |
| |
||
| Line 261: | Line 241: | ||
| |
| |
||
| |
| |
||
|[[Other Dry Etching Recipes|R3]] |
|||
| |
| |
||
|R1 |
|||
|{{rl|Other Dry Etching Recipes|Other Dry Etch (XeF2 Etcher)}} |
|||
| |
|||
|A |
|||
|- bgcolor="#ffffff" |
|- bgcolor="#ffffff" |
||
! bgcolor="#d0e7ff" align="center" |Ta |
! bgcolor="#d0e7ff" align="center" |Ta |
||
| |
|||
| |
| |
||
| |
| |
||
| Line 281: | Line 259: | ||
| |
| |
||
| |
| |
||
| |
|R1 |
||
|A |
|||
|- bgcolor="#eeffff" |
|- bgcolor="#eeffff" |
||
! bgcolor="#d0e7ff" align="center" |Ti |
! bgcolor="#d0e7ff" align="center" |Ti |
||
| |
|||
| |
| |
||
| |
| |
||
| Line 291: | Line 267: | ||
| |
| |
||
|{{rl|ICP Etching Recipes|Ti Etch (Panasonic 1)}} |
|{{rl|ICP Etching Recipes|Ti Etch (Panasonic 1)}} |
||
|R1 |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|R1 |
|||
|- bgcolor="#ffffff" |
|||
! bgcolor="#d0e7ff" align="center" |W |
|||
| |
|||
| |
|||
| |
|||
|[[ICP Etching Recipes#W Etching (Fluorine ICP Etcher)|R3]] |
|||
|{{rl|ICP Etching Recipes|W-TiW Etch (Panasonic 1)}} |
|||
|R1 |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|R1 |
|||
|- |
|||
!TiW |
|||
| |
|||
| |
|||
| |
|||
|R3 |
|||
| |
|||
|R1 |
|R1 |
||
| |
| |
||
| Line 300: | Line 308: | ||
| |
| |
||
| |
| |
||
|A |
|||
|- bgcolor="#ffffff" |
|- bgcolor="#ffffff" |
||
! bgcolor="#d0e7ff" align="center" |Al<sub>2</sub>O<sub>3</sub> |
! bgcolor="#d0e7ff" align="center" |Al<sub>2</sub>O<sub>3</sub> |
||
| |
|||
| |
| |
||
| |
| |
||
| Line 309: | Line 315: | ||
| |
| |
||
|A |
|A |
||
|[[ICP Etching Recipes#Al2O3 Etching .28Panasonic 2.29|R3]] |
|||
|[https://wiki.nanotech.ucsb.edu/w/index.php?title=ICP_Etching_Recipes#Al2O3_Etching_.28Panasonic_2.29 R3] |
|||
| |
| |
||
| |
| |
||
| Line 317: | Line 323: | ||
| |
| |
||
| |
| |
||
| |
|R1 |
||
|A |
|||
|- bgcolor="#eeffff" |
|- bgcolor="#eeffff" |
||
! bgcolor="#d0e7ff" align="center" |Al<sub>2</sub>O<sub>3 (Sapphire)</sub> |
! bgcolor="#d0e7ff" align="center" |Al<sub>2</sub>O<sub>3 (Sapphire)</sub> |
||
| |
|||
| |
| |
||
| |
| |
||
| Line 335: | Line 339: | ||
| |
| |
||
| |
| |
||
| |
|R1 |
||
|A |
|||
|- bgcolor="#ffffff" |
|- bgcolor="#ffffff" |
||
! bgcolor="#d0e7ff" align="center" |AlGaAs |
! bgcolor="#d0e7ff" align="center" |AlGaAs |
||
| |
| |
||
|[[RIE Etching Recipes|R3]] |
|||
| |
|||
|{{rl|RIE Etching Recipes|AlGaAs\GaAs Etching (RIE 5)}} |
|||
| |
| |
||
| |
| |
||
| Line 347: | Line 349: | ||
| |
| |
||
|[[ICP Etching Recipes#GaAs Etch .28Oxford ICP Etcher.29|R3]] |
|[[ICP Etching Recipes#GaAs Etch .28Oxford ICP Etcher.29|R3]] |
||
|{{rl|ICP Etching Recipes|ICP-Etch (Unaxis VLR)|GaAs-AlGaAs Etch (Unaxis VLR)|AlGaAs Etch (Unaxis VLR)}} |
|||
| |
| |
||
| |
| |
||
| Line 354: | Line 355: | ||
| |
| |
||
| |
| |
||
| |
|R1 |
||
|- bgcolor="#eeffff" |
|- bgcolor="#eeffff" |
||
! bgcolor="#d0e7ff" align="center" |AlGaN |
! bgcolor="#d0e7ff" align="center" |AlGaN |
||
| |
|||
| |
| |
||
| |
| |
||
| Line 365: | Line 365: | ||
| |
| |
||
|[[ICP Etching Recipes#GaN Etch .28Oxford ICP Etcher.29|R2]] |
|[[ICP Etching Recipes#GaN Etch .28Oxford ICP Etcher.29|R2]] |
||
|{{rl|ICP Etching Recipes|GaN Etch (Unaxis VLR)}} |
|||
| |
| |
||
| |
| |
||
| Line 372: | Line 371: | ||
| |
| |
||
| |
| |
||
| |
|R1 |
||
|- bgcolor="#ffffff" |
|- bgcolor="#ffffff" |
||
! bgcolor="#d0e7ff" align="center" |AlN |
! bgcolor="#d0e7ff" align="center" |AlN |
||
| Line 383: | Line 382: | ||
| |
| |
||
| |
| |
||
|{{rl|ICP Etching Recipes|GaN Etch (Unaxis VLR)}} |
|||
| |
| |
||
| |
| |
||
| Line 389: | Line 387: | ||
| |
| |
||
| |
| |
||
| |
|R1 |
||
|A |
|||
|- |
|- |
||
!BCB |
!BCB |
||
| |
|||
| |
| |
||
| |
| |
||
| Line 399: | Line 395: | ||
| |
| |
||
|A |
|A |
||
| |
|||
| |
| |
||
| |
| |
||
| Line 411: | Line 406: | ||
|- bgcolor="#eeffff" |
|- bgcolor="#eeffff" |
||
! bgcolor="#d0e7ff" align="center" |CdZnTe |
! bgcolor="#d0e7ff" align="center" |CdZnTe |
||
| |
|[[RIE Etching Recipes|R3]] |
||
| |
| |
||
| |
| |
||
| Line 424: | Line 419: | ||
| |
| |
||
| |
| |
||
| |
|R1 |
||
| |
|||
|A |
|||
|- bgcolor="#ffffff" |
|- bgcolor="#ffffff" |
||
! bgcolor="#d0e7ff" align="center" |GaAs |
! bgcolor="#d0e7ff" align="center" |GaAs |
||
| |
| |
||
|[[RIE Etching Recipes|R3]] |
|||
| |
|||
|{{rl|RIE Etching Recipes|AlGaAs\GaAs Etching (RIE 5)}} |
|||
| |
| |
||
| |
| |
||
|{{rl|ICP Etching Recipes|GaAs-AlGaAs Etch (Panasonic 1)}} |
|{{rl|ICP Etching Recipes|GaAs-AlGaAs Etch (Panasonic 1)}} |
||
|[[ICP Etching Recipes#GaAs Etch .28Panasonic 2.29|R6]] |
|||
|[https://wiki.nanofab.ucsb.edu/wiki/ICP_Etching_Recipes#GaAs_Etch_.28Panasonic_2.29 R3] |
|||
|[[ICP Etching Recipes#GaAs Etch .28Oxford ICP Etcher.29|R3]] |
|[[ICP Etching Recipes#GaAs Etch .28Oxford ICP Etcher.29|R3]] |
||
|{{rl|ICP Etching Recipes|ICP-Etch (Unaxis VLR)|GaAs-AlGaAs Etch (Unaxis VLR)|GaAs Etch (Unaxis VLR)}} |
|||
| |
| |
||
| |
| |
||
| Line 444: | Line 435: | ||
| |
| |
||
| |
| |
||
| |
|R1 |
||
|- bgcolor="#eeffff" |
|- bgcolor="#eeffff" |
||
! bgcolor="#d0e7ff" align="center" |GaN |
! bgcolor="#d0e7ff" align="center" |GaN |
||
| |
| |
||
|[[RIE Etching Recipes|R3]] |
|||
| |
|||
|{{rl|RIE Etching Recipes|GaN Etching (RIE 5)}} |
|||
| |
| |
||
| |
| |
||
|{{rl|ICP Etching Recipes|GaN Etch (Panasonic 1)}} |
|{{rl|ICP Etching Recipes|GaN Etch (Panasonic 1)}} |
||
|R1 |
|R1 |
||
|[[ICP Etching Recipes#GaN Etch .28Oxford ICP Etcher.29| |
|[[ICP Etching Recipes#GaN Etch .28Oxford ICP Etcher.29|R6]] |
||
|{{rl|ICP Etching Recipes|GaN Etch (Unaxis VLR)}} |
|||
| |
| |
||
| |
| |
||
| Line 462: | Line 451: | ||
| |
| |
||
| |
| |
||
| |
|R1 |
||
|- bgcolor="#ffffff" |
|- bgcolor="#ffffff" |
||
! bgcolor="#d0e7ff" align="center" |GaSb |
! bgcolor="#d0e7ff" align="center" |GaSb |
||
| |
|||
| |
| |
||
| |
| |
||
| Line 473: | Line 461: | ||
|R1 |
|R1 |
||
|R1 |
|R1 |
||
|{{rl|ICP Etching Recipes|ICP-Etch (Unaxis VLR)|GaSb Etch Unaxis VLR)}} |
|||
| |
| |
||
| |
| |
||
| Line 480: | Line 467: | ||
| |
| |
||
| |
| |
||
| |
|R1 |
||
|- bgcolor="#eeffff" |
|- bgcolor="#eeffff" |
||
! bgcolor="#d0e7ff" align="center" |HfO<sub>2</sub> |
! bgcolor="#d0e7ff" align="center" |HfO<sub>2</sub> |
||
| Line 491: | Line 478: | ||
| |
| |
||
| |
| |
||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|R1 |
|||
|- |
|||
!Hf |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|R2 |
|||
| |
| |
||
| |
| |
||
| Line 498: | Line 500: | ||
| |
| |
||
| |
| |
||
|A |
|||
|- bgcolor="#ffffff" |
|- bgcolor="#ffffff" |
||
! bgcolor="#d0e7ff" align="center" |InGaAlAs |
! bgcolor="#d0e7ff" align="center" |InGaAlAs |
||
| |
|[[RIE Etching Recipes|R3]] |
||
| |
|||
| |
| |
||
| |
| |
||
| Line 509: | Line 509: | ||
| |
| |
||
|R1 |
|R1 |
||
|{{rl|ICP Etching Recipes|ICP-Etch (Unaxis VLR)|InP-InGaAs-InAlAs Etch (Unaxis VLR)|InP Etch (Unaxis VLR)}} |
|||
| |
| |
||
| |
| |
||
| Line 516: | Line 515: | ||
| |
| |
||
| |
| |
||
| |
|R1 |
||
|- bgcolor="#eeffff" |
|- bgcolor="#eeffff" |
||
! bgcolor="#d0e7ff" align="center" |InGaAsP |
! bgcolor="#d0e7ff" align="center" |InGaAsP |
||
| |
|[[RIE Etching Recipes|R3]] |
||
| |
|||
| |
| |
||
| |
| |
||
| Line 527: | Line 525: | ||
| |
| |
||
|[[ICP Etching Recipes#InP Ridge Etch .28Oxford ICP Etcher.29|R3]] |
|[[ICP Etching Recipes#InP Ridge Etch .28Oxford ICP Etcher.29|R3]] |
||
|{{rl|ICP Etching Recipes|ICP-Etch (Unaxis VLR)|InP-InGaAs-InAlAs Etch (Unaxis VLR)|InP Etch (Unaxis VLR)}} |
|||
| |
| |
||
| |
| |
||
| Line 534: | Line 531: | ||
| |
| |
||
| |
| |
||
| |
|R1 |
||
|- bgcolor="#ffffff" |
|- bgcolor="#ffffff" |
||
! bgcolor="#d0e7ff" align="center" |InP |
! bgcolor="#d0e7ff" align="center" |InP |
||
| |
|[[RIE Etching Recipes|R3]] |
||
| |
|||
| |
| |
||
| |
| |
||
| Line 545: | Line 541: | ||
|R1 |
|R1 |
||
|[[ICP Etching Recipes#InP Ridge Etch .28Oxford ICP Etcher.29|R6]] |
|[[ICP Etching Recipes#InP Ridge Etch .28Oxford ICP Etcher.29|R6]] |
||
|{{rl|ICP Etching Recipes|ICP-Etch (Unaxis VLR)|InP-InGaAs-InAlAs Etch (Unaxis VLR)|InP Etch (Unaxis VLR)}} |
|||
| |
| |
||
| |
| |
||
| Line 552: | Line 547: | ||
| |
| |
||
| |
| |
||
| |
|[[Other Dry Etching Recipes|R3]] |
||
|- bgcolor="#eeffff" |
|- bgcolor="#eeffff" |
||
! bgcolor="#d0e7ff" align="center" |ITO |
! bgcolor="#d0e7ff" align="center" |ITO |
||
| |
|[[RIE Etching Recipes|R3]] |
||
| |
| |
||
| |
| |
||
| Line 561: | Line 556: | ||
| |
| |
||
| |
| |
||
|R1 |
|||
| |
| |
||
| |
| |
||
| Line 567: | Line 563: | ||
| |
| |
||
| |
| |
||
|R1 |
|||
|- |
|||
!LiNbO3 |
|||
| |
| |
||
| |
| |
||
| |
| |
||
| |
|R1 |
||
|- |
|||
!LiNbO3 |
|||
| |
| |
||
| |
| |
||
| Line 582: | Line 579: | ||
| |
| |
||
| |
| |
||
|R1 |
|||
|- bgcolor="#ffffff" |
|||
!Photoresist & Organics |
|||
| |
| |
||
|[[RIE Etching Recipes#Photoresist and ARC (RIE 5)|R3]] |
|||
| |
| |
||
|[[ICP Etching Recipes#Photoresist .26 ARC .28Fluorine ICP Etcher.29|R3]] |
|||
|[https://wiki.nanotech.ucsb.edu/wiki/ICP_Etching_Recipes#Photoresist_and_ARC_Etching_.28Panasonic_1.29 R3] |
|||
|[[ICP Etching Recipes#Al2O3 Etching .28Panasonic 2.29|R3]] |
|||
| |
| |
||
|R3 |
|||
|[[Oxygen Plasma System Recipes#O2 Ashing|R3]] |
|||
|[[Oxygen Plasma System Recipes#O2 Ashing|R3]] |
|||
| |
| |
||
| |
| |
||
| |
| |
||
| |
|R1 |
||
|- |
|||
|- bgcolor="#ffffff" |
|||
!ARC (Anti Reflective Coating) |
|||
!Photoresist |
|||
| |
|||
& ARC |
|||
| |
|||
| |
|||
|[[ICP Etching Recipes#Photoresist .26 ARC .28Fluorine ICP Etcher.29|R3]] |
|||
| |
|||
| |
|||
| |
| |
||
|A |
|||
|[https://wiki.nanotech.ucsb.edu/wiki/RIE_Etching_Recipes#Photoresist_and_ARC_.28RIE_5.29 R] |
|||
| |
| |
||
|[https://wiki.nanotech.ucsb.edu/wiki/ICP_Etching_Recipes#Photoresist_.26_ARC_.28Fluorine_ICP_Etcher.29 R4] |
|||
|[https://wiki.nanotech.ucsb.edu/wiki/ICP_Etching_Recipes#Photoresist_and_ARC_Etching_.28Panasonic_1.29 R] |
|||
|[https://wiki.nanotech.ucsb.edu/wiki/ICP_Etching_Recipes#Photoresist_and_ARC_etching_.28Panasonic_2.29 R3] |
|||
| |
| |
||
| |
| |
||
|[[Oxygen Plasma System Recipes#O2 Ashing|R]] |
|||
|[[Oxygen Plasma System Recipes#Plasma Clean .28YES EcoClean.29|R]] |
|||
| |
| |
||
| |
| |
||
| |
| |
||
| |
| |
||
|A |
|||
|- bgcolor="#eeffff" |
|- bgcolor="#eeffff" |
||
! bgcolor="#d0e7ff" align="center" |SiC |
! bgcolor="#d0e7ff" align="center" |SiC |
||
| |
|||
| |
| |
||
| |
| |
||
| Line 624: | Line 627: | ||
| |
| |
||
| |
| |
||
| |
|R1 |
||
|A |
|||
|- bgcolor="#ffffff" |
|- bgcolor="#ffffff" |
||
! bgcolor="#d0e7ff" align="center" |SiN |
! bgcolor="#d0e7ff" align="center" |SiN |
||
| |
| |
||
|{{rl|RIE Etching Recipes|RIE 3 (MRC)|SiN<sub>x</sub> Etching (RIE 3)}} |
|||
| |
| |
||
| |
| |
||
|[[ICP Etching Recipes#Si3N4 Etching .28Fluorine ICP Etcher.29| |
|[[ICP Etching Recipes#Si3N4 Etching .28Fluorine ICP Etcher.29|R3]] |
||
|{{rl|ICP Etching Recipes|SiNx Etching (Panasonic 1)}} |
|{{rl|ICP Etching Recipes|SiNx Etching (Panasonic 1)}} |
||
|[[ICP Etching Recipes#SiNx Etching .28Panasonic 2.29|R3]] |
|||
|[https://wiki.nanofab.ucsb.edu/wiki/ICP_Etching_Recipes#SiNx_Etching_.28Panasonic_2.29 R3] |
|||
| |
| |
||
|[[Oxygen Plasma System Recipes#O2 Ashing|R3]] |
|||
| |
| |
||
|A |
|||
| |
| |
||
| |
| |
||
| |
| |
||
| |
| |
||
| |
|R1 |
||
|A |
|||
|- bgcolor="#eeffff" |
|- bgcolor="#eeffff" |
||
! bgcolor="#d0e7ff" align="center" |SiO<sub>2</sub> |
! bgcolor="#d0e7ff" align="center" |SiO<sub>2</sub> |
||
| |
| |
||
|{{rl|RIE Etching Recipes|RIE 3 (MRC)|SiO<sub>2</sub> Etching (RIE 3)}} |
|||
| |
| |
||
|[[ICP Etching Recipes#SiO2 Etch (DSEiii)|R3]] |
|||
| |
|||
|[[ICP Etching Recipes#SiO2 |
|[[ICP Etching Recipes#SiO2 Etch Recipes (Fluorine ICP Etcher)|R6]] |
||
|{{rl|ICP Etching Recipes|SiO2 Etching (Panasonic 1)}} |
|{{rl|ICP Etching Recipes|SiO2 Etching (Panasonic 1)}} |
||
|[[ICP Etching Recipes#SiO2 Etching .28Panasonic 2.29|R6]] |
|||
|[https://wiki.nanofab.ucsb.edu/wiki/ICP_Etching_Recipes#SiO2_Etching_.28Panasonic_2.29 R6] |
|||
| |
| |
||
| |
| |
||
| Line 659: | Line 658: | ||
| |
| |
||
| |
| |
||
|[[Other Dry Etching Recipes|R3]] |
|||
| |
|||
|R1 |
|||
|{{rl|Other Dry Etching Recipes|Other Dry Etch (Vapor HF Etcher)}} |
|||
|A |
|||
|- bgcolor="#ffffff" |
|- bgcolor="#ffffff" |
||
! bgcolor="#d0e7ff" align="center" |SiOxNy |
! bgcolor="#d0e7ff" align="center" |SiOxNy |
||
| |
|||
| |
| |
||
| |
| |
||
| Line 678: | Line 675: | ||
| |
| |
||
| |
| |
||
| |
|R1 |
||
|A |
|||
|- |
|- |
||
!SU8 |
!SU8 |
||
| |
|||
| |
| |
||
| |
| |
||
| Line 688: | Line 683: | ||
| |
| |
||
|A |
|A |
||
| |
|||
| |
| |
||
| |
| |
||
| Line 700: | Line 694: | ||
|- bgcolor="#eeffff" |
|- bgcolor="#eeffff" |
||
! bgcolor="#d0e7ff" align="center" |Ta<sub>2</sub>O<sub>5</sub> |
! bgcolor="#d0e7ff" align="center" |Ta<sub>2</sub>O<sub>5</sub> |
||
| |
|||
| |
| |
||
| |
| |
||
| Line 706: | Line 699: | ||
| |
| |
||
|A |
|A |
||
|R1 |
|||
|[https://www.osapublishing.org/optica/abstract.cfm?uri=optica-4-5-532 R1] |
|||
| |
| |
||
| |
| |
||
| Line 714: | Line 707: | ||
| |
| |
||
| |
| |
||
| |
|R1 |
||
|A |
|||
|- bgcolor="#ffffff" |
|- bgcolor="#ffffff" |
||
! bgcolor="#d0e7ff" align="center" |TiN |
! bgcolor="#d0e7ff" align="center" |TiN |
||
| Line 731: | Line 723: | ||
| |
| |
||
| |
| |
||
| |
|R1 |
||
| |
|||
|A |
|||
|- bgcolor="#eeffff" |
|- bgcolor="#eeffff" |
||
! bgcolor="#d0e7ff" align="center" |TiO<sub>2</sub> |
! bgcolor="#d0e7ff" align="center" |TiO<sub>2</sub> |
||
| Line 749: | Line 739: | ||
| |
| |
||
| |
| |
||
| |
|||
| |
|||
|A |
|||
|- bgcolor="#ffffff" |
|||
! bgcolor="#d0e7ff" align="center" |W-TiW |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|{{rl|ICP Etching Recipes|W-TiW Etch (Panasonic 1)}} |
|||
|R1 |
|R1 |
||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
| |
|||
|A |
|||
|- bgcolor="#eeffff" |
|- bgcolor="#eeffff" |
||
! bgcolor="#d0e7ff" align="center" |ZnO<sub>2</sub> |
! bgcolor="#d0e7ff" align="center" |ZnO<sub>2</sub> |
||
| Line 785: | Line 755: | ||
| |
| |
||
| |
| |
||
| |
|R1 |
||
| |
|||
|A |
|||
|- bgcolor="#ffffff" |
|- bgcolor="#ffffff" |
||
! bgcolor="#d0e7ff" align="center" |ZnS |
! bgcolor="#d0e7ff" align="center" |ZnS |
||
| |
|[[RIE Etching Recipes|R3]] |
||
| |
| |
||
| |
| |
||
| Line 803: | Line 771: | ||
| |
| |
||
| |
| |
||
| |
|R1 |
||
| |
|||
|A |
|||
|- bgcolor="#eeffff" |
|- bgcolor="#eeffff" |
||
! bgcolor="#d0e7ff" align="center" |ZnSe |
! bgcolor="#d0e7ff" align="center" |ZnSe |
||
| |
|[[RIE Etching Recipes|R2]] |
||
| |
| |
||
| |
| |
||
| Line 821: | Line 787: | ||
| |
| |
||
| |
| |
||
| |
|R1 |
||
| |
|||
|A |
|||
|- bgcolor="#ffffff" |
|- bgcolor="#ffffff" |
||
! bgcolor="#d0e7ff" align="center" |ZrO<sub>2</sub> |
! bgcolor="#d0e7ff" align="center" |ZrO<sub>2</sub> |
||
| Line 831: | Line 795: | ||
| |
| |
||
| |
| |
||
|R1 |
|||
| |
| |
||
| |
| |
||
| Line 838: | Line 803: | ||
| |
| |
||
| |
| |
||
| |
|R1 |
||
| |
|||
| |
|||
|A |
|||
|- bgcolor="#eeffff" |
|- bgcolor="#eeffff" |
||
! bgcolor="#d0e7ff" align="center" |'''Material''' |
! bgcolor="#d0e7ff" align="center" |'''Material''' |
||
| bgcolor="#daf1ff" |[[RIE_Etching_Recipes#RIE_2_.28MRC.29|RIE 2<br> <span style="font-size: 88%;">(MRC)</span>]] |
| bgcolor="#daf1ff" |[[RIE_Etching_Recipes#RIE_2_.28MRC.29|RIE 2<br> <span style="font-size: 88%;">(MRC)</span>]] |
||
| bgcolor="#daf1ff" |[[RIE_Etching_Recipes#RIE_3_.28MRC.29|RIE 3<br> <span style="font-size: 88%;">(MRC)</span>]] |
|||
| bgcolor="#daf1ff" |[[RIE_Etching_Recipes#RIE_5_.28PlasmaTherm.29|RIE 5<br><span style="font-size: 88%;">(PlasmaTherm)</span>]] |
| bgcolor="#daf1ff" |[[RIE_Etching_Recipes#RIE_5_.28PlasmaTherm.29|RIE 5<br><span style="font-size: 88%;">(PlasmaTherm)</span>]] |
||
| bgcolor="#daf1ff" |[[ICP_Etching_Recipes#DSEIII_.28PlasmaTherm.2FDeep_Silicon_Etcher.29|DSEIII<br><span style="font-size: 88%;">(PlasmaTherm)</span>]] |
| bgcolor="#daf1ff" |[[ICP_Etching_Recipes#DSEIII_.28PlasmaTherm.2FDeep_Silicon_Etcher.29|DSEIII<br><span style="font-size: 88%;">(PlasmaTherm)</span>]] |
||
| Line 852: | Line 813: | ||
| bgcolor="#daf1ff" |[[ICP Etching Recipes#ICP Etch 2 .28Panasonic E626I.29|ICP Etch 2<br><span style="font-size: 88%;">(Panasonic E640)</span>]] |
| bgcolor="#daf1ff" |[[ICP Etching Recipes#ICP Etch 2 .28Panasonic E626I.29|ICP Etch 2<br><span style="font-size: 88%;">(Panasonic E640)</span>]] |
||
| bgcolor="#daf1ff" |[[ICP Etching Recipes#Oxford ICP Etcher .28PlasmaPro 100 Cobra.29|Oxford ICP <span style="font-size: 88%;">(PlasmaPro 100)</span>]] |
| bgcolor="#daf1ff" |[[ICP Etching Recipes#Oxford ICP Etcher .28PlasmaPro 100 Cobra.29|Oxford ICP <span style="font-size: 88%;">(PlasmaPro 100)</span>]] |
||
| bgcolor="#daf1ff" |[[ICP_Etching_Recipes#ICP-Etch_.28Unaxis_VLR.29|ICP-Etch<br><span style="font-size: 88%;">(Unaxis VLR)</span>]] |
|||
| bgcolor="#daf1ff" |[[Oxygen_Plasma_System_Recipes#Ashers_.28Technics_PEII.29|Ashers<br><span style="font-size: 88%;">(Technics PEII)</span>]] |
| bgcolor="#daf1ff" |[[Oxygen_Plasma_System_Recipes#Ashers_.28Technics_PEII.29|Ashers<br><span style="font-size: 88%;">(Technics PEII)</span>]] |
||
| bgcolor="#daf1ff" |[[Oxygen Plasma System Recipes#Plasma Clean .28YES EcoClean.29|Plasma Clean <span style="font-size: 88%;">(YES EcoClean)</span>]] |
| bgcolor="#daf1ff" |[[Oxygen Plasma System Recipes#Plasma Clean .28YES EcoClean.29|Plasma Clean <span style="font-size: 88%;">(YES EcoClean)</span>]] |
||
| Line 862: | Line 822: | ||
|} |
|} |
||
=== |
===Process Ranking Table=== |
||
Processes in the table above are ranked by their "''Process Maturity Level''" as follows: |
Processes in the table above are ranked by their "''Process Maturity Level''" as follows: |
||
{| class="wikitable" |
{| class="wikitable" |
||
| Line 872: | Line 832: | ||
|- |
|- |
||
|R1 |
|R1 |
||
| colspan="11" |Process has been |
| colspan="11" |Process has been ran at least once |
||
|- |
|- |
||
|R2 |
|R2 |
||
| colspan="11" |Process has been |
| colspan="11" |Process has been ran and procedure is documented |
||
|- |
|- |
||
|R3 |
|R3 |
||
| colspan="11" |Process has been |
| colspan="11" |Process has been ran, procedure is documented, and data is available |
||
|- |
|- |
||
|R4 |
|R4 |
||
| colspan="11" |Process has a documented procedure with regular |
| colspan="11" |Process has a documented procedure with regular (≥4x per year) data '''no''' in-Situ control available |
||
|- |
|- |
||
|R5 |
|R5 |
||
| colspan="11" |Process has a documented procedure with regular |
| colspan="11" |Process has a documented procedure with regular (≥4x per year) data '''and''' in-Situ control available |
||
|- |
|- |
||
|R6 |
|R6 |
||
| colspan="11" |Process has a documented procedure |
| colspan="11" |Process has a documented procedure and control charts/limits available. Controlled process. |
||
|} |
|} |
||
[[Category:Processing]] |
[[Category:Processing]] |
||
Latest revision as of 22:16, 23 September 2026
Process Control Data
See above linked page for process control data (dep rate/stress etc. over time), for a selection of often-used dry etches
Dry Etching Tools/Materials Table
Process Maturity Ranking
R6- most mature process with regular calibrations recorded on SPC charts.- …
R1- least mature - only run once ever.
The Key/Legend for this table's A...R6 values is at the bottom of the page.
Process Ranking Table
Processes in the table above are ranked by their "Process Maturity Level" as follows:
| Process Level | Description of Process Level Ranking | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| A | Process Allowed and materials available but never done | ||||||||||
| R1 | Process has been ran at least once | ||||||||||
| R2 | Process has been ran and procedure is documented | ||||||||||
| R3 | Process has been ran, procedure is documented, and data is available | ||||||||||
| R4 | Process has a documented procedure with regular (≥4x per year) data no in-Situ control available | ||||||||||
| R5 | Process has a documented procedure with regular (≥4x per year) data and in-Situ control available | ||||||||||
| R6 | Process has a documented procedure and control charts/limits available. Controlled process. | ||||||||||